Velleman HAA85WP User Manual

HAA85WP
MULTI-PURPOSE SECURITY KEYPAD MULTIFUNCTIONEEL VEILIGHEIDSTOETSENBORD CLAVIER DE SECURITE A DIVERS USAGES TECLADO DE SEGURIDAD MULTIFUNCIÓN MULTIFUNKTIONSCODESCHLOSS
GEBRUIKERSHANDLEIDING NOTICE D’EMPLOI MANUAL DEL USUARIO BEDIENUNGSANLEITUNG
HAA85WP - MULTI-PURPOSE SECURITY KEYPAD
1. Introduction
To all residents of the European Union Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialised company for recycling. This device should be returned to your distributor or to a local recycling
service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for buying the HAA85WP! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, don't install or use it and contact your dealer.
HAA85WP digital access keypad is a self-contained, three-output system, designed for door strike and security control applications. It employs EEPROM, the system's programmed data is non-volatile in case of power failure. Over 100 million combinations are possible for the three independent user codes (code 1, code 2 & code 3) and the master code (it also acts as the super user code). The user code 1 can be altered to act as a duress code for reporting duress to an alarm system or to a telephone dialler. Other security features include door sensing for door auto re-lock function and a built-in tamper switch. For convenience, the keypad also provides the facility for connecting an egress button inside the protected area for easy exit. The plastic case of the keypad unit is precisely engineered, in which, the front panel and the mounting box is sealed with a water resistant gasket making the keypad suitable for both in-door and out-door installations.
Outputs of the HAA85WP: OUTPUT 1 OUTPUT 2 OUTPUT 3 5 Amp relay 1 Amp relay 1 Amp relay
2. Connection Terminals
HAA85WP VELLEMAN
2
* 12V AC/DC: Power supply input, 12V AC or DC is possible, no polarity discrimination for the terminals.
* OUTPUT 1: 5 Amp dry relay contacts, with Normally Open (N.O.) and Normally Closed (N.C.) terminals. This relay
is primarily prepared for door strike application or for alarm ON-OFF control. Use the N.O. contact for door strike connection. If for alarm ON-OFF control, connect the appropriate pair of these terminals (N.C. or N.O.) to the remote ARM/DISARM terminals on your alarm system; consult the manual for your system. N.O. or N.C. loop is possible. Relay contact is programmable for momentary or start/stop operation.
* OUTPUT 2: Output 2 is prepared for alarm ON-OFF control or for reporting panic event to an alarm system or to a
telephone dialler. The output is programmable for momentary or start/stop operation. 1 Amp dry relay contacts, with Normally Open (N.O.) and Normally Closed (N.C.) terminals.
* OUTPUT 3: Output 3 has identical function as output 2. It is recommended for alarm ON-OFF control or for the
auxiliary functional control in your system. 1 Amp dry relay contacts, with Normally Open (N.O.) and Normally Closed (N.C.) terminals.
* TAMPER N.C.: Tamper switch Normally Close contact. It is open when the keypad is separated from the mounting
box.
* GROUND (-): The grounding point of the keypad.
* DOOR N.C.: This terminal is prepared for connecting a Normally Closed optional door sensing switch to the door
which is controlled by output 1, for initiating the auto re-lock function.
With the help of the door sensing switch, the keypad releases the door latch immediately to re-lock the
door automatically after the door is re-closed even the pre-set operation time is not expired in momentary mode ; or you do not require to enter Code 1 again to re-lock the door when the keypad is in Start/Stop mode.
In normal operation without the door sensing switch, an opened door is re-locked after time-out in
momentary mode; or by entering Code 1 again in Start/Stop mode.
NOTE: If the door sensing switch is not used, connect the terminal to Ground (-).
* DURESS OUTPUT: NPN transistor Open Collector output, switch of the (-) supply when the Duress Code is
entered. Use this output to trigger remote alarm, dialler, indicator, etc., in case of duress. Transistor rating -- Ic max.: 150mA. Vce max.: 12VDC
* EGRESS N.O.: A Normally Open (N.O.) input terminal refers to (-) ground with the help of a normally open button to
activate the Relay Output 1. Egress button is usually put inside the house near the door. Leave this terminal open if it is not used.
* GREEN & RED LEDS: Two 12 de-energised LED lamps are available for free connections, to indicate alarm or
door operation status. They are built-in with 1.5k Ohm current limiting resistors.
3. Pacifier Tones & LED Indicating Signals
The built-in buzzer and the amber LED indicator give the following tones and signals for operation status:
STATUS TONES LED SIGNALS
1. In programming mode --- ON
2. Successful key entry 1 Beep 1 Flash
3. Successful code entry 2 Beeps 2 Flashes
4. Unsuccessful code entry 5 Beeps 5 Flashes
5. DAP jumper not replaced Continuous beep Continuous Flashes
6. In standby mode --- 1 Flash in 2 seconds interval
HAA85WP VELLEMAN
3
4. DAP Jumper (Direct Access to Programming)
If the Personal Master Code is forgotten, use the DAP jumper to override the forgotten code permitting direct entry into programming mode. You are required to apply the following procedure precisely:
1. Disconnect power supply
2. Displace the DAP jumper from OFF to ON position.
3. Reconnect power supply (buzzer is activated).
4. Put the DAP jumper back to OFF position (this done, the buzzer is de-activated).
5. The Keypad is in programming mode and ready to receive your new programming data.
6. Enter the new programming data starting from Section (B) in the summary chart shown below.
5. Programming the Keypad – Summary Chart
A) Use the factory set Master Code entry in programming -- When starting for first time only
Entry of Code Validation Comments
0000 * Enter in programming mode by factory set master code
B) Programming -- Recording of personal master code & user codes -- User programming
Access Keys Entry of Codes Validation Comments
0 From 1 to 8 Digits # Personal Master Code & Super User Code 1 From 1 to 8 Digits # User Code 1 & Duress Code
( Suggest for door strike ) 2 From 1 to 8 Digits # User Code 2 ( Suggest for alarm control ) 3 From 1 to 8 Digits # User Code 3 (Suggest for alarm or auxiliary
control)
C) Programming -- Configuration of relay outputs -- Installer programming
Access Keys Code Duration
(Seconds) 4 0 From 1 to 999 # Output 1 in MOMENTARY mode from 1 to 999 seconds (*) 4 1 / # Output 1 in START/STOP mode without accelerated code
4 2 / # Output 1 in START/ STOP mode with accelerated code (*). 5 0 From 1 to 999 # Output 2 in MOMENTARY mode from 1 to 999 seconds 5 1 / # Output 2 in START/STOP mode without accelerated code. 5 2 / # Output 2 in START/ STOP mode with accelerated code. 6 0 From 1 to 999 # Output 3 in MOMENTARY mode from 1 to 999 seconds 6 1 / # Output 3 in START/STOP mode without accelerated code. 6 2 / # Output 3 in START/ STOP mode with accelerated code.
(*) Auto re-lock is possible, see "DOOR N.C." for details.
D) Programming -- Safety -- Installer Programming
Access Keys Validation Comments
7 0 # After 10 successive false codes, the keypad locks during 30 seconds. 7 1 # After 10 successive false codes, the DURESS output is switching to
7 2 # Disappearance of the 2 above securities.
E) Leave programming mode
Validation Comments
* The keypad leaves programming mode, and is in OPERATION mode, ready for daily use.
Validation Comments
(*).
ground.
HAA85WP VELLEMAN
4
6. Keyboard Illumination LED
2 0 3 9 # 8
0 0 0 0
8 2 6 4 # 5
3 1 8 1 # 2
0 4 5 #
1 5 #
0 7 #
3289
has been stored as the new Personal Master code &
Relay output 2 has been set in Start/stop Mode without
Keypad has been set to lock during 30 seconds after 10
Programming is finished. All the data above have been
2 3 9 0 # 7
2 6 #
Relay output 3 has been set in Start/stop Mode with
The keyboard illumination LED lights up for 10 seconds when a key button is pressed, which indicates the duration of the allowable time for each digit of continuous code entry. The digit of code entry is invalid beyond the allowable time when the LED lamp is off.
7. Factory Set Data
For the owner's convenience in programming at the first time, the factory has put a MASTER CODE 0000 into the keypad. Except that code, no other useful code or data has been put into the keypad. The owner has to put his own UNIQUE CODES and DATA into the keypad before use.
8. Important Note to Owner
To compromise security, in all cases, the owner should program a PERSONAL MASTER CODE for his keypad in order to invalidate the factory set 0000 Master Code.
9. Programming the Keypad - Example
1) REQUIREMENT -- The following data are required to be stored:
a) Change the factory set Master Code 0000 to a Personal Master Code 3289 b) Set User Code 1 in 8321 c) Set User Code 2 in 6854 d) Set User Code 3 in 9270 e) Set Output 1 in Momentary Mode, 5 seconds f) Set Output 2 in Start/Stop Mode without accelerated code g) Set Output 3 in Start/Stop Mode with accelerated code h) Set the keypad to lock itself during 30 seconds after 10 successive false codes
2) PROGRAMMING -- Put the required data above into the keypad
Note: In case of wrong entry during programming, cancel it with key #, or wait 10 seconds, then re-enter.
Enter in programming mode by the Factory Set Master Code.
8321 has been stored as User Code 1 & Duress Code.
6854 has been stored as User Code 2.
9270 has been stored as User Code 3.
Relay output 1 has been set in Momentary Mode, 5 seconds
accelerated code.
accelerated code.
successive false codes.
stored and ready for use.
HAA85WP VELLEMAN
5
10. Use the Keypad – Taking the Stored Data Above as Reference
0 3 2 1 #
Duress output activates, and relay output 1 activates for 5
8 3 2 # 2 9
8 3 2 # 1 9
8 3 2 # 3 9
9 2 7 0 #
9 2 #
8 3 2 1 #
9 2 7 0 #
6 8 5 4 #
1) To command the outputs 1, 2 & 3, enter the corresponding codes into the keypad and validate via #.
2) The Personal Master Code is also the SUPER USER CODE for output 1, 2 and 3. It allows the owner to use ONLY ONE code to operate the 3 outputs. To command outputs 1, 2 & 3, enter the Personal Master Code into the keypad and validate via # PLUS and the corresponding output numbers.
3) The DURESS CODE does not need to be programmed. The keypad determines it automatically by increasing the first digit of the User Code 1 by TWO units.
e.g. If we have the User Code 1 is 1234, then the keypad will determine the Duress Code as 3234. In the above programming example, we have made User Code 1 as 8321, the Duress Code has been determined
as 0321 automatically by the keypad.
To command the DURESS OUTPUT, enter the Duress Code by increasing the first digit of Code 1 of TWO units
and validate via #.
The Duress Code has a double action. It controls the Relay Output 1 at the same time as the User Code 1 and
activates the Duress Output. The Duress Code can always activate and deactivate the Relay Output 1, but can not deactivate the Duress Output. ONLY the composition of the User Code 1 can deactivate (reset) the Duress Output.
4) To command the outputs using ACCELERATED CODE, if the one output from 1 to 3, has been programmed in Start/Stop with the Accelerated Code, it is possible to activate with only the FIRST TWO digits, from Code 1 to Code 3, of the corresponding code. Deactivating of this output always requires the composition of the Complete Code.
In this example, the Output 3 has been programmed in Start/Stop Mode with Accelerated Code. The Complete Code 3 : 9270 The Accelerated Code: 92
Relay output 1 activates for 5 seconds
Output 2 starts (or stops)
Output 3 starts (or stops)
Output 1 activates for 5 seconds.
Output 2 starts.
Output 3 starts.
seconds.
Output 3 starts
Output 3 stops
HAA85WP VELLEMAN
6
5) Try to put 1 to 8 digit random false codes to the keypad to test its safety. The keypad generates 5 beeps for each
8 3 2 1 #
3 2 8 9
4 1
#
Output 1 has been changed from Momentary to Start/Stop
7 1
#
The keypad has been changed from locks 30 seconds to
The keypad is back to operation mode.
unsuccessful code entry after the # button is pressed. The keypad locks during 30 seconds after 10 successive false codes are entered. Normal operation will be resumed after the 30 seconds are expired.
NOTE: The maximum allowable time for SUCCESSIVE DIGIT and CODE entry are 10 seconds and 30
seconds respectively. The keypad refreshes itself automatically after 30 seconds of silence even some false codes were entered.
11. Reprogram the Keypad for other Operation Modes
6) To access to PROGRAMMING MODE, enter your Personal Master Code and validate via *.
7) Set Relay Output 1 in Start/Stop Mode.
8) Set keypad to activate DURESS OUTPUT after 10 successive false codes.
9) Re-program is finish. To leave programming mode, validate via *.
The keypad is in Programming Mode & ready to receive new data.
with Accelerated code.
activates Duress Output
The re-programmed data have been stored.
12. Use the Keypad with the Reprogrammed Data
10) To command Relay Output 1, enter the User Code 1 and validate via #.
In Start/Stop operation mode, it is necessary to enter Code 1 again to STOP Output 1. If Output 1 is for door
strike application, it is suggested to work with a door sensing switch to initiate the auto re-lock (STOP) function, in which, enter code 1 for re-locking is not necessary.
11) Try to put 1 to 8 digits false codes to the keypad to test its safety. The keypad will activate the DURESS OUTPUT after 10 successive false codes are entered. To reset (deactivate) the Duress Output, you are required to enter the composition of the User Code 1 and validate via #.
12) In case of wrong data entry in operation, press # to cancel, then re-try; or wait 10 seconds, then re-try.
13. Specifications
* Operation Voltage : 12V DC (10-14VDC) * Current Drain : 15 - 150mA * Operation Codes : User Code 1, 2 & 3, Super User Code, Master Code, Duress Code, & Accelerated
Code * Code Combinations : 111111100 * Relay Outputs : Output 1 -- 5 Amp, Other outputs -- 1 Amp
Relay output 1 starts
HAA85WP VELLEMAN
7
* Duress Output : 150mA sink / 12V DC Open Collector switch to ground * Digit Entry Time : 10 Seconds, auto refresh * Code Entry Time : 30 Seconds, auto refresh * Dimensions : 129 (H) mm x 84 (W) x 41 (D) mm * Weight : 220g net Specifications are subject to change for modification without notice.
14. Typical Application
* OUTPUT 1 ----------------- DOOR STRIKE * OUTPUT 2 ----------------- MAIN ALARM CONTROL * OUTPUT 3 ----------------- AUXILIARY ALARM CONTROL
* Please consult your alarm control panel manual for the selection of N.C. or N.O. for alarm ON-OFF control.
15. Appendix
1. DRY CONTACT -------- A dry contact means no electricity was connected to it. It is prepared for free
connections. Usually the relay contacts provided in a keypad are dry contacts.
2. N.C. ------------------------ Normally Closed, the contact is closed circuit at normal status. It is open circuit when
activated.
3. N.O. ------------------------ Normally Open, the contact is open circuit at normal status. It is closed circuit when
activated.
4. TRANSISTOR OPEN COLLECTOR OUTPUT --- An open collector output is equivalent to a Normally Open (N.O.)
contact referring to ground similar to a relay contact referring to ground. The transistor is normally OFF, and its output is switched to ground (-) when activated. The open collector can only provide switching function for small power but it is usually good enough for controlling an alarm system.
The Duress Output is Open Collector Output.
The information in this manual is subject to change without prior notice. HAA85WP VELLEMAN
8
HAA85WP - MULTIFUNCTIONEEL VEILIGHEIDSTOETSENBORD
1. Inleiding
Aan alle ingezetenen van de Europese Unie Belangrijke milieu-informatie betreffende dit product
Dit symbool op het toestel of de verpakking geeft aan dat, als het na zijn levenscyclus wordt weggeworpen, dit toestel schade kan toebrengen aan het milieu. Gooi dit toestel (en eventuele batterijen) niet bij het gewone huishoudelijke afval; het moet bij een gespecialiseerd bedrijf terechtkomen voor recyclage. U moet dit toestel
naar uw verdeler of naar een lokaal recyclagepunt brengen. Respecteer de plaatselijke milieuwetgeving.
Heeft u vragen, contacteer dan de plaatselijke autoriteiten inzake verwijdering.
Dank u voor uw aankoop! Lees deze handleiding grondig voor u het toestel in gebruik neemt. Werd het toestel beschadigd tijdens het transport, installeer het dan niet en raadpleeg uw dealer.
De HAA85WP is een onafhankelijk beveiligingstoetsenbord met 3 uitgangen. Het werd ontworpen om elektrische deuren te sturen en voor beveiligingstoepassingen. De HAA85WP maakt gebruik van een EEPROM, d.w.z. dat de opgeslagen gegevens niet verloren gaan wanneer de voedingsspanning uitvalt. Er zijn meer dan 100 miljoen combinaties mogelijk voor de Gebruikerscodes (code 1, code 2 en code 3 ) en de Meestercode (die ook als Supergebruikerscode kan fungeren). De Gebruikerscode 1 kan veranderd worden om gebruikt te worden als Gedwongen Code om de Gedwongen uitgang te activeren. Deze kan worden toegepast om een alarmsysteem of een automatische telefoonoproeper te activeren. Andere beveiligingseigenschappen zijn onder meer een deur-"voeler" voor een automatische deursluitfunctie en een ingebouwde tamper schakelaar. Voor het gemak heeft het toetsenbord de mogelijkheid om een "uitgangs"-knop aan te sluiten. Deze knop dient om de beveiligde zone gemakkelijk te verlaten. De plastieken behuizing is speciaal ontworpen met een waterbestendige afdichting. Dit om het zowel binnenhuis en buitenhuis te kunnen gebruiken.
Uitgangen van de HAA85WP: UITGANG 1 UITGANG 2 UITGANG 3 5 Amp relais 1 Amp relais 1 Amp relais
2. Aansluitingen
HAA85WP VELLEMAN
9
* 12V AC/DC: Voeding, 12V AC of DC. Beide zijn mogelijk.
* UITGANG 1: 5 Amp droog relais-contacten, met Normaal Open (N.O.) en Normaal Gesloten (N.C. = Normally
Closed) klemmen. Het relais is voorbereid om een deurschakelaar of een alarm aan-uit controle aansluiting op aan te sluiten. Gebruik het N.O. contact voor de deurschakelaar-aansluiting. Indien u er een AAN-UIT alarm wenst op aan te sluiten, sluit dan de draden van de uitgang (N.C. of N.O.) aan de ARM/DISARM aansluiting van uw alarmsysteem; raadpleeg daarvoor de handleiding van uw alarmsysteem. Een N.O. of N.C. lus is mogelijk. Het relais-contact is programmeerbaar voor een momentane (momentary) of een start/stop werking.
* UITGANG 2: Uitgang 2 is voorbereid om bijvoorbeeld een AAN-UIT alarmcontrole of voor een panieksituatie aan
een alarmsysteem of aan een telefoonoproeper te melden. De uitgang is programmeerbaar voor een momentane of een start/stop werking. 1 Amp droog relais-contacten, met Normaal Open (N.O.) en Normaal Gesloten (Normally Closed = N.C.) aansluitingen.
* UITGANG 3: Uitgang 3 heeft dezelfde functie als uitgang 2. Het is voorbereid om een AAN/UIT alarm te controleren
of een bijkomende functionele controle in uw systeem. 1 Amp droog relais-contacten, met Normaal Open (N.O.) en Normaal Gesloten (Normally Closed = N.C.) aansluitingen.
* TAMPER N.C.: Tamper schakelaar Normaal Gesloten contact. Wanneer het toetsen los is van de plastieken
behuizing is deze schakelaar open.
* MASSA (-): Het aardingspunt van het toetsenbord.
* DEUR N.C.: Deze aansluiting werd voorbereid om een optionele deur-"voeler" aan te sluiten, waarvan de deur
gecontroleerd wordt door uitgang 1, for initiating the auto re-lock function.
With the help of the door sensing switch, the keypad releases the door latch immediately to re-lock the
door automatically after the door is re-closed even the pre-set operation time is not expired in momentary mode ; or you do not require to enter Code 1 again to re-lock the door when the keypad is in Start/Stop mode.
In normal operation without the door sensing switch, an opened door is re-locked after time-out in
momentary mode; or by entering Code 1 again in Start/Stop mode.
NOTE: If the door sensing switch is not used, connect the terminal to Ground (-).
* GEDWONGEN UITGANG: NPN transistor Open Collector uitgang, schakelt naar de (-) voedingsspanning wanneer
de Gedwongen Code ingegeven wordt. Gebruik deze uitgang om alarmen, telefoonoproepers, indicatoren op aan te sluiten. Transistor -- Ic max.: 150mA. Vce max.: 12VDC
* UITGANG N.O. EGRESS: Een Normaal Open ( N.O. ) ingang die aan de ( - ) massa kan geschakeld worden met
de EGRESS knop; dit om Relais uitgang 1 te activeren. De egress knop wordt meestal in het huis zelf geplaatst bij de deur. Laat deze aansluiting open indien u deze niet gebruikt.
* GROENE & RODE LEDs: Twee 12V LEDs zijn beschikbaar voor vrije aansluiting, om er om het even welke functie
op aan te sluiten. Elke LED is voorzien van een 1.5k Ohm stroombeperkende weerstand.
3. Geluidssignalen & LED-signalen
De ingebouwde buzzer en de amber LED geven de volgende tonen en signalen:
STATUS SIGNAAL LED SIGNAAL
1. In programmeer mode --- ON
2. Toets is goed ingedrukt 1 Bib 1 Flash
3. Code is goed ingetoetst 2 Bibs 2 Flashes
4. Code is fout ingetoetst 5 Bibs 5 Flashes
5. DAP jumper werd niet geplaatst Continue bib Knippert continu
6. Standby mode --- 1 Knippering per 2 seconden
HAA85WP VELLEMAN
10
4. DAP-jumper (Direct Acces to Programming – Directe Toegang tot de programmeermode)
Indien de eigen meestercode vergeten werd, kunt u de DAP jumper gebruiken om de vergeten code te overbruggen, dit om een directe toegang tot de programmeermode te verkrijgen. U moet wel de volgende procedure nauwkeurig toepassen:
1. Koppel de voedingsspanning los.
2. Verander de DAP jumper van de OFF naar de ON positie.
3. Koppel de voedingsspanning terug aan. (U hoort de buzzer)
4. Plaats de DAP jumper terug in de OFF positie (wanneer dit gebeurt, zal de buzzer niet meer weerklinken).
5. Het toetsenbord is nu in programmeermode en is klaar om het nieuwe programma te ontvangen.
6. Toets het nieuwe programma in, startend vanaf punt (B) in het hieropvolgend deel "PROGRAMMEREN VAN HET
TOETSENBORD"
5. Programmeren van het toetsenbord - Hoofdtabel
A) Gebruik de meestercode van de fabrikant om in de programmeermode te komen -- Wanneer u voor de allereerste
keer programmeert
Intoetsen van de code Bevestiging Commentaar
0000 * Toegang in de programmeermode d.m.v. de meestercode van de
fabrikant
B) Programmeren -- Opnemen van de persoonlijke meestercode en de gebruikerscodes -
Gebruikersprogrammering
Toegangs-
toetsen
0 1 tot 8 digits # Persoonlijke Meestercode & Supergebruikerscode 1 1 tot 8 digits # Gebruikerscode 1 & Gedwongen code
2 1 tot 8 digits # Gebruikerscode 2 (Voor b.v. alarm controle) 3 1 tot 8 digits # Gebruikerscode 3 (Voor b.v. alarm of bijkomende controle)
C) Programmeren -- Configuratie van de relaisuitgangen -- Installatie programmering
Toegangs-
toetsen
4 0 1 tot 999 # Uitgang 1 in MOMENTANE mode van 1 tot 999 secondes (*) 4 1 / # Uitgang 1 in START/STOP mode zonder verkorte code (*). 4 2 / # Uitgang 1 in START/ STOP mode met verkorte code (*). 5 0 1 tot 999 # Uitgang 2 in MOMENTANE mode van 1 tot 999 secondes 5 1 / # Uitgang 2 in START/STOP mode zonder verkorte code. 5 2 / # Uitgang 2 in START/ STOP mode met verkorte code. 6 0 1 tot 999 # Uitgang 3 in MOMENTANE mode van 1 tot 999 secondes 6 1 / # Uitgang 3 in START/STOP mode zonder verkorte code. 6 2 / # Uitgang 3 in START/ STOP mode met verkorte code.
(*) Auto re-lock is mogelijk, zie "DEUR N.C." voor meer details.
D) Programmeren -- Veiligheid -- Installatie Programmering
Toegangstoetsen Bevestiging Commentaar
Intoetsen van
Bevestiging Commentaar
de codes
( Voor deurschakelaar of aan-uit van het alarm)
Tijdsduur
Bevestiging Commentaar
(Secondes)
7 0 # Na 10 opeenvolgende slecht ingetikte codes, zal het toetsenbord
blokkeren gedurende 30 seconden.
7 1 # Na 10 opeenvolgende slecht ingetikte codes, zal de Gedwongen
uitgang naar massa geschakeld worden.
7 2 # Verdwijnen van de 2 bovenstaande veiligheid.
HAA85WP VELLEMAN
11
E) De programmeermode verlaten
2 0 3 9 # 8
0 0 0 0
8 2 6 4 # 5
3 1 8 1 # 2
0 4 5 #
1 5 #
0 7 #
De progra
mmeermode betreden door de Meestercode van
3289
wordt opgeslagen als de nieuwe persoonlijke
8321
wordt opgeslagen als Gebruikerscode 1 en Gedwongen
Relais
-
uitgang 1 wordt gezet op Momentane mode, 5
Relais
-
uitgang 2 wordt gezet op Start/stop Mode zonder
Het toetsenbord wordt, na 10 valse codes, gedurende 30
Het programmeren is gedaan. Alle nodig
e informatie wordt
2 3 9 0 # 7
2 6 #
Relais
-
uitgang 3 wordt gezet op Start/stop Mode met
Bevestiging Commentaar
* Het toetsenbord verlaat de programmeermode, en in meteen operationeel, klaar voor het dagelijks
gebruik.
6. Oplichting van het toetsenbord
Telkens wanneer er een knop op het toetsenbord ingedrukt wordt, zal het toetsenbord gedurende 10 seconden oplichten. Gedurende die oplichting heeft de gebruiker de tijd om een nieuwe toets in te tikken. Elke ingave na de toegestane tijd dat de LED lamp aan is, is ongeldig.
7. Code van de fabrikant
Voor het gemak van de gebruiker bij de eerste keer, heeft de fabrikant een Meestercode 0000 in het toetsenbord geprogrammeerd. Buiten deze code is er geen enkel andere code of andere data in het toetsenbord gezet. De gebruiker moet zijn eigen UNIEKE CODES en GEGEVENS in het toetsenbord programmeren vooraleer te gebruiken.
8. Belangrijke opmerking voor de gebruiker
Om een totale veiligheid te bekomen, moet de gebruiker een EIGEN PERSOONLIJKE MEESTER CODE voor zijn toetsenbord intikken, en dit om de door de fabrikant ingestelde Meestercode 0000 te verwijderen.
9. Programmeren van het toetsenbord - Voorbeeld
1) VEREISTEN -- Stel dat de volgende gegevens geprogrammeerd moeten worden:
a) Verander de Meester Code 0000 naar een Persoonlijke Meester Code 3289 b) Stel de Gebruikerscode 1 op 8321 c) Stel de Gebruikerscode 2 op 6854 d) Stel de Gebruikerscode 3 op 9270 e) Stel relais uitgang 1 in Momentane Mode, 5 seconden f) Stel relais uitgang 2 in Start/Stop Mode zonder verkorte code g) Stel relais uitgang 3 in Start/Stop Mode met verkorte code h) Stel het toetsenbord in om, na 10 valse codes, gedurende 30 seconden te blokkeren.
2) PROGRAMMERING -- Tik de gewenste gegevens van hierboven in het toetsenbord
de fabrikant in te tikken.
Meestercode & Supergebruikerscode.
code. 6854 wordt opgeslagen als Gebruikerscode 2.
9270 wordt opgeslagen als Gebruikerscode 3.
seconden
versnelde code.
versnelde code.
seconden geblokkeerd.
HAA85WP VELLEMAN