HAA85 – MULTIPURPOSE SECURITY KEYPAD
0
123
456
789
RED
AMBER
GREEN
1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm
the environment.
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized
company for recycling.
This device should be returned to your distributor or to a local recycling service.
Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for buying the HAA85! Please read the manual thoroughly before bringing this device into service. If the
device was damaged in transit, don't install or use it and contact your dealer.
The HAA85 is a self-contained dual-output security keypad, designed for electric door strike and security control
applications. It employs EEPROM, the stored data is non-volatile in case of power failure. Over 100 million
combinations are possible for the user codes (code 1 & code 2) and the master code (it also acts as the super user
code). The user code 1 can be altered to act as a duress code to activate the duress output for reporting duress to an
alarm system or to a telephone dialler. The keypad can be configured to have different operation combinations by
using the two user code outputs, such as utilizing code 1 for door strike and code 2 for alarm ON-OFF control; or
making code 1 for alarm ON-OFF control and code 2 for reporting panic event to an alarm system.
2. Connections
*
* 12V DC POWER: Connect to 12VDC power supply. The (-) supply is the grounding point of the keypad.
* OUTPUT RELAY 1: 2 Amp dry relay contacts, with Normally Open (N.O.) and Normally Closed (N.C.) terminals.
#
This relay is prepared for door strike or alarm ON-OFF control connection. Use the N.O. contact for door
strike connection. If for alarm ON-OFF control, connect the appropriate pair of these terminals (N.C. or
N.O.) to the remote ARM/DISARM terminals on your alarm system; consult the manual for your system.
N.O. or N.C. loop is possible. Relay contact is programmable for momentary or start/stop operation.
HAA85VELLEMAN
4
* OUTPUT RELAY 2: 1 Amp dry relay contacts, with Normally Open (N.O.) and Normally Closed (N.C.) terminals.
This relay is prepared for alarm ON-OFF control or reporting panic event connection. Connect the
appropriate pair of these terminals to the remote ARM/DISARM terminals on your alarm system for
alarm ON-OFF control; or to the panic/24 hour emergency loop for panic triggering. N.O. or N.C. loop
connection is possible. Relay contact is programmable for momentary or start/stop operation.
* DURESS OUTPUT: An NPN transistor Open Collector output. It switches to (-) supply when the Duress Code is
* N.C. TAMPER: Normally Closed contact when the keypad is secured on the box. It is open when keypad is
separated from the box. Connect these terminals in series with the tamper/panic/24hour emergency
circuit loop on your alarm system if necessary.
* RED, AMBER & GREEN LED LAMPS: Three on-board LED lamps are available. They are prepared for free
connections. Suggest connecting these LED lamps to the remote indicator terminals on your alarm
control panel. Be sure to observe the polarity (+ & -). Each of the on-board LED lamps is equipped with
a 1.5K ohm current limiting resistor.
* EGRESS OUTPUT: A Normally Open (N.O.) input terminal refers to the (-) ground with the help of a Normally Open
button to activate the Relay Output 1. The egress button is usually put inside the house near the door.
Leave this terminal open if not used.
3. The Pacifier Tones
The built-in buzzer generates the following tones for operation status:
If the Personal Master Code is forgotten, use the DAP jumper to override the forgotten code permitting direct entry
into programming mode. You are required to apply the following procedure precisely:
1. Disconnect power supply
2. Displace the DAP jumper from OFF to ON.
3. Reconnect power supply (buzzer is activated).
4. Put the DAP jumper back to OFF position (this done, the buzzer is de-activated).
5. The Keypad is in programming mode and ready to receive your new programming data.
6. Enter the new programming data starting from Section (B) in the summary chart shown below.
5. Program the Keypad – Summary Chart
A) Use the factory set master code entry in programming -- When starting for first time only
Entry of Code Validation Comments
0000 * Enter in programming mode by factory set master code
B) Programming -- Recording of personal master code & user codes -- User programming
Access Keys Entry of Codes Validation Comments
0 From 1 to 8 Digits # Personal Master Code & Super User Code
1 From 1 to 8 Digits # User Code 1 & Duress Code (For door strike
or alarm ON-OFF)
2 From 1 to 8 Digits # User Code 2 (For alarm ON-OFF or panic
event reporting)
HAA85VELLEMAN
5
C) Programming -- Configuration of relay outputs -- Installer programming
Access Keys Code Duration
Validation Comments
(Seconds)
4 0 From 1 to 999 # Output 1 in MOMENTARY mode from 1 to 999
seconds
4 1 / # Output 1 in START/STOP mode without
accelerated code.
4 2 / # Output 1 in START/ STOP mode with
accelerated code.
5 0 From 1 to 999 # Output 2 in MOMENTARY mode from 1 to 999
seconds
5 1 / # Output 2 in START/STOP mode without
accelerated code.
5 2 / # Output 2 in START/ STOP mode with
accelerated code.
D) Programming -- Safety -- Installer Programming
Access Keys Validation Comments
7 0 # After 10 successive false codes, the keypad locks during 30
seconds.
7 1 # After 10 successive false codes, the DURESS output is switching to
ground.
7 2 # Disappearance of the 2 above securities.
E) Leave programming mode
Validation Comments
* The keypad leaves programming mode, and is in OPERATION mode, ready for daily
use.
6. The Factory Set Data
For the owner's convenience in programming at the first time, the factory has put a MASTER CODE 0000 into the
keypad. Except that code, no other useful code or data has been put into the keypad. The owner has to put his own
UNIQUE CODES and DATA into the keypad before use.
IMPORTANT NOTE TO OWNER
To compromise security, in all cases, the owner should program a PERSONAL MASTER CODE for his keypad in
order to invalidate the factory set 0000 master code.
PROGRAM THE KEYPAD -- EXAMPLE
1) REQUIREMENTS -- The following data are required to be stored:
a) Change the factory set Master Code 0000 to a Personal Master Code 3289
b) Set User Code 1 in 8321
c) Set User Code 2 in 6854
d) Set relay output 1 in Momentary Mode, 5 seconds
e) Set relay output 2 in Start/Stop Mode without accelerated code
f) Set keypad to lock during 30 seconds after 10 successive false code
HAA85VELLEMAN
6
2) PROGRAMMING -- Put the required data above into the keypad
0 3 2 1 #
Duress output activates, and relay output 1 activates for 5
8 3 2 # 2 9
8 3 2 # 1 9
2
0
0
0
0 0 0
4 5
3 9 # 8
8 2 6 4 # 5
3 1 8 1 # 2
#
1 5 #
0 7 #
3289
has been stored a
s the new Personal Master code &
Relay output 2 has been set in Start/stop Mode without
The keypad has been set to lock during 30 seconds after 10
Programming is finished. All the required data above have
8 3 2 1 #
6 8 5 4 #
Note: In case of wrong entry during programming, cancel it with key #, or wait 10 seconds, then re-enter.
Enter in programming mode by the factory set master code.
Super User code.
8321 has been stored as User Code 1 & Duress Code.
6854 has been stored as User Code 2.
Relay output 1 has been set in Momentary Mode, 5 seconds
accelerated code.
successive false codes.
been stored.
7. Use the Keypad – Taking the Stored Data Above as Reference
1) To command relay output 1, enter the user code 1 and validate via #.
2) To command relay output 2, enter the user code 2 and validate via #.
3) The Personal Master Code is also the SUPER USER CODE for relay output 1 and 2. The owner can use only
ONE code to operate the two outputs. To command outputs 1 and 2, enter the Personal Master Code into the
keypad and validate via # and the corresponding output number.
Relay output 1 activates for 5 seconds.
Relay output 2 starts.
Relay output 1 activates for 5 seconds.
Relay output 2 starts.
4) The DURESS CODE does not need to be programmed. The keypad determines it automatically by increasing the
first digit of the User Code 1 by TWO units.
e.g. If we have the User Code 1 is 1234, then the keypad will determine the Duress Code as 3234.
In the above programming example, we have made User Code 1 as 8321, the Duress Code has been determined
as 0321 automatically by the keypad. To command the DURESS OUTPUT, enter the Duress Code and validate
via #.
The Duress Code has a double action; it controls the relay output 1 at the same time as the User Code and
activates the Duress Output. Only the composition of the User Code 1 can deactivate the Duress Output. The
Duress Code can always activate and deactivate the relay output 1, but can not deactivate the Duress Output.
HAA85VELLEMAN
seconds.
7
5) Try to put 1 to 8 digit random false codes to the keypad. The keypad generates 5 beeps for each unsuccessful
3 2 8 9
The keypad is in programming mode & ready t
o receive new
4 2
#
Relay output 1 has been changed from Momentary to
7 1
#
The keypad has been changed from locks 30 seconds to
8 3 #
8 3 2 1 #
The keypad is back to operation mode. The re
-
progra
mmed
code entry after the # button is pressed. The keypad locks during 30 seconds after 10 successive false codes are
entered. Normal operation will be resumed after the 30 seconds are expired.
Re-program the keypad for other operation modes
6) To access to programming mode, enter your Personal Master Code and validate via *.
7) Set relay output 1 in Start/Stop Mode with Accelerated Code.
8) Set keypad to activate Duress Output after 10 successive false codes.
9) To leave programming mode, press *.
Use the keypad with the re-programmed data
10) The relay output 1 has been programmed in Start/Stop mode with Accelerated Code. It is possible to activate the
output 1 with ONLY the First Two Digits of the user code 1. Deactivation of the output always require the
composition of the complete code.
e.g. Complete User Code 1 : 8321 Accelerated Code: 83
11) Try to put 1 to 8 digits false codes to the keypad. The keypad will activate the Duress Output after 10 successive
false codes are entered. To reset (deactivate) the Duress Output, you are required to enter the composition of the
User Code 1 and validate via #.
data.
Start/Stop with Accelerated code.
activates Duress Output
data have been stored.
Relay output 1 starts (activates)
Relay output 1 stops (deactivates)
8. Specifications
* Operation Voltage 12V DC (10-14VDC)
* Current Drain 10 - 100mA
* Duress Output NPN transistor open collector switches to ground (-) when activated,
100mA/25V DC max
* Codes available User 1 & 2, Super User, Master, Duress and Accelerated Codes
* Code Combinations 111111100
* Relay Outputs Output 1 -- 2 Amp, Output 2 -- 1 Amp, N.C. & N.O. dry contacts, 30V
DC max
* Dimensions 117(H)mm X 74(W)mm X 48(D)mm
* Weight 180g (net), 230g (gross) approx.
The information in this manual is subject to change without prior notice.
HAA85 VELLEMAN
8
9. Typical Applications
* OUTPUT 1 ----------------- DOOR STRIKE
* OUTPUT 2 ----------------- ALARM CONTROL
* DURESS OUTPUT ------- DIALLER / PANIC
* AMBER/RED LED ------- ALARM STATUS INDICATIONS
* GREEN LED -------------- DOOR OPEN
HAA85 – MULTIFUNCTIONEEL TOETSENBORD
1. Inleiding
Aan alle ingezetenen van de Europese Unie
Belangrijke milieu-informatie betreffende dit product
Dit symbool op het toestel of de verpakking geeft aan dat, als het na zijn levenscyclus wordt weggeworpen,
dit toestel schade kan toebrengen aan het milieu.
Gooi dit toestel (en eventuele batterijen) niet bij het gewone huishoudelijke afval; het moet bij een
gespecialiseerd bedrijf terechtkomen voor recyclage.
U moet dit toestel naar uw verdeler of naar een lokaal recyclagepunt brengen.
Respecteer de plaatselijke milieuwetgeving.
Hebt u vragen, contacteer dan de plaatselijke autoriteiten inzake verwijdering.
De HAA85 is een onafhankelijk beveiligingstoetsenbord met dubbele uitgang. Het werd ontworpen om elektrische
deuren te sturen en voor beveiligingstoepassingen. De HAA85 maakt gebruik van een EEPROM, d.w.z. dat de
opgeslagen gegevens niet verloren gaan wanneer de voedingsspanning uitvalt. Er zijn meer dan 100 miljoen
combinaties mogelijk voor de Gebruikerscodes (code 1 & code 2) en de Meestercode (die ook als
Supergebruikerscode kan fungeren). De Gebruikerscode 1 kan veranderd worden om gebruikt te worden als
Gedwongen Code om de Gedwongen Uitgang te activeren. Deze kan worden toegepast om een alarmsysteem of
een automatisch telefoonoproeper te activeren. Het toetsenbord kan ingesteld worden om verschillende
werkcombinaties te hebben. En dit d.m.v. de twee gebruikerscode-uitgangen, zoals code 1 om de deur te bedienen
en code 2 om het alarm te activeren, of bijvoorbeeld code 1 die het alarm activeert en code 2 die een paniek-signaal
naar een alarmsysteem stuurt.
HAA85VELLEMAN
9
2. Bedrading
*
123
456
789
0
* 12V DC VOEDING: Sluit een 12VDC voeding aan. De (-) klem is het aardingspunt van het toetsenbord.
* UITGANG RELAIS 1: 2 Amp droog relais-contacten, met Normaal Open (N.O.) en Normaal Gesloten (= Normally
Closed) (N.C.) klemmen. Het relais is voorbereid om een deurschakelaar of een alarm aan-uit
controle aansluiting op aan te sluiten. Gebruik het N.O. contact voor de deurschakelaar-aansluiting.
Indien u er een aan-uit alarm wenst op aan te sluiten, sluit dan de draden van de uitgang (N.C. of N.O.)
aan de ARM/DISARM-aansluitingen van uw alarmsysteem;
raadpleeg daarvoor de handleiding van uw alarmsysteem. Een N.O. of N.C. schakeling is mogelijk. Het
relais-contact is programmeerbaar voor een moment (momentary) of een start/stop werking.
* UITGANG RELAIS 2: 1 Amp droog relais-contacten, met Normaal Open (N.O.) en Normaal Gesloten (= Closed)
(N.C.) aansluitingen. Dit relais werd voorbereid om een aan-uit alarm-controle of om een
paniektoestand-signaal op aan te sluiten.
Sluit de uitgangsdraden aan de ARM/DISARM-bevestigingen van het alarmsysteem om een aan-uit
alarmcontrole te verkrijgen; of aan de paniek/24 uur noodschakeling voor de paniekfunctie.
Een N.O. of N.C. schakeling is mogelijk. Het relais-contact is programmeerbaar voor een kortstondige
(momentary) of een start/stop werking.
* GEDWONGEN UITGANG: Deze uitgang is een NPN transistor Open Collector uitgang. Wanneer de Gedwongen
code ingetoetst wordt schakelt deze uitgang naar de massa (-). Specificaties uitgangstransistor -- Ic
max : 100mA sink. Vce max : 25VDC
* N.C. TAMPER: Normaal Gesloten (= Closed) contact wanneer het toetsenbord aan de doos bevestigd is. Het wordt
geopend wanneer het frontpaneel van de doos verwijderd wordt. Sluit deze uitgang in serie aan de
tamper/paniek/24uur noodschakeling op uw alarmsysteem indien u dit wenst.
* RODE, AMBER & GROENE LED's: Er zijn 3 LED's op het paneel voorhanden. Ze werden voorbereid om er om het
even welke functie op aan te sluiten. Wij stellen voor om deze LED's aan de indicatie-aansluitingen van
uw alarmcontrole paneel aan te sluiten. Houd de juiste polariteit (+ & -) in het oog. Elk paneel-LED is
voorzien van 1.5K ohm stroombeperkende weerstand.
* AANSLUITING UITGANG: Een Normaal Open (N.O.) ingangsaansluiting wordt aangesloten op (-) door middel van
een Normaal Open knop om de relaisuitgang 1 te activeren. De knop wordt doorgaans binnenshuis
naast de deur geplaatst. Laat de aansluiting open wanneer u deze niet gebruikt.
ROOD
AMBER
GROEN
#
HAA85VELLEMAN
10
3. Geluidssignalen
De ingebouwde buzzer geeft de volgende signalen weer:
STATUS SIGNAAL
Toets is goed ingedrukt 1 biep
Code is juist ingetoetst 2 bieps
Code is fout ingetoetst 5 bieps
DAP jumper werd niet opnieuw geplaatst Continue biep
4. De DAP jumper (Direct Access to Programming)
Indien de eigen meestercode vergeten werd, kunt u de DAP jumper gebruiken om de vergeten code te overbruggen,
dit om een directe toegang tot de programmeermode te verkrijgen. U moet wel de volgende procedure nauwkeurig
toepassen:
1. Koppel de voedingsspanning los.
2. Verander de DAP jumper van OFF naar ON.
3. Koppel de voedingsspanning terug aan. (de buzzer weerklinkt).
4. Plaats de DAP jumper terug in de OFF positie (wanneer dit gebeurd is, zal de buzzer niet meer weerklinken).
5. Het toetsenbord is nu in programmeermode en is klaar om het nieuwe programmaatje te ontvangen.
6. Toets het nieuwe programma in, startend vanaf punt B) in het hieropvolgend deel "PROGRAMMEREN VAN HET
TOETSENBORD"
5. Programmeren van het toetsenbord - Hoofdtabel
A) Gebruik de meestercode van de fabrikant om in de programmeermode te komen.
Intoetsen van de
code
0000 * Toegang in de programmeermode d.m.v. de meester code van de
B) Programmeren -- Opnemen van de persoonlijke meestercode en de gebruikerscode --
2 1 tot 8 digits # Gebruikerscode 2 (Voor aan-uit van het alarm of
C) Programmeren -- Configuratie van de relais uitgangen -- Installatie programmering
Toegangs-
toetsen
4 0 1 tot 999 # Uitgang 1 in MOMENT mode van 1 tot 999 seconden
4 1 / # Uitgang 1 in START/STOP mode zonder verkorte code.
4 2 / # Uitgang 1 in START/ STOP mode met verkorte code.
5 0 1 tot 999 # Uitgang 2 in MOMENT mode van 1 tot 999 seconden
5 1 / # Uitgang 2 in START/STOP mode zonder verkorte code.
5 2 / # Uitgang 2 in START/STOP mode met verkorte code.
HAA85VELLEMAN
Bevestiging Commentaar
fabrikant
Intoetsen van
Bevestiging Commentaar
de codes
Tijdsduur
Bevestiging Commentaar
(sec)
Supergebruikerscode
deurschakelaar of aan-uit van het alarm)
een paniek signaal)