INTRODUCTION
Vaisala model SPH10 Pressure Head provides an effective
elimination of pressure variations in the barometer due to the
wind. The SPH10 is easy to clean and maintain. It can be
integrated directly with the Vaisala PTB210 barometer. To other
barometers the SPH10 can be connected with pressure tubing.
ASSEMBLING
1. Screw the lower bar to the threaded sleeve of the lower
plates (with 6 holes).
2. Screw the upper bar (with mounting plate) to the threaded
sleeve of the upper plates.
MOUNTING
Select an open location, prefereably a place higher than the
surroundings, with no buildings or trees nearby. Attach the
SPH10 to a horizontal pole using a mounting plate. A suitable
pole is Vaisala sensor mast, type DKP12. However, any other
horizontal pole with two screws (M6) in a distance of 41 mm can
be used.
NOTE The recommended distance of the SPH10
from the vertical pole is at least 1.5 m.
1. Loosen the two fixing screws of the pole and fix the SPH10
into the pole as indicated in Figure 1.
2. Attach
the SPH10 by tightening the screws. (The pressure
Head is removed by loosening the two screws).
CONNECTION TO THE VAISALA PTB210
Visualization in Figure 2.
1. Detach the threaded nipple and the gasket (see figure 1).
2. Place the O-ring into the barometer groove.
3. Attach the PTB210 to the SPH10 with two fixing screws.
CONNECTION TO OTHER BAROMETERS
Connect the barometer to the threaded nipple (Figure 1) by using
a flexible, airtight tube with an inner diameter of 4 mm. To
prevent condence water accumulation in the tube, make sure the
entire length of the tube goes downwards from the barometer to
SPH10.
Figure 1 SPH10 Static Pressure Head
Figure 2 PTB210 Barometer Connection
For warranty information, visit our Internet pages at:
www.vaisala.com/warranty.html
TECHNICAL DATA
Property Description / Value
Materials
Plates Polycarbonate
Bars Offshore Aluminium
Mounting with 2 bolts
Weight 800 g
Hose connection barbed fitting for 4 mm I.D.
(M6 x minimum 20 mm)
hose or Rp1/4 thread
(parallel)
MAINTENANCE
WARRANTY
Visit our Internet pages for standard warranty terms and
conditions: www.vaisala.com/warranty.
lease observe that any such warranty may not be valid in case
P
of damage due to normal wear and tear, exceptional operating
conditions, negligent handling or installation, or unauthorized
modifications. Please see the applicable supply contract or
Conditions of Sale for details of the warranty for each product.
TECHNICAL SUPPORT AND PRODUCT
RETURNS
For technical questions, contact the Vaisala technical support by
e-mail at helpdesk@vaisala.com.
If the product must be returned for service, see
www.vaisala.com/returns.
F
or contact information of Vaisala Service Centers, see
www.vaisala.com/servicecenters.
Figure 3 Detaching the Lower Plate for Cleaning
Cleaning the SPH10 is done by detaching the lower bar and the
lower plate. The barometer can be in place while cleaning the
plates. Follow the instructions below:
1. Unscrew the lower bar and detach it.
2. Open the self-locking nut with a 13 mm spanner.
3. Remove the threaded sleeve and take out the lower plate
4. Clean the plates.
5. Replace the lower plate, the protective wire net and the
Keep the holes of the lower plate open to allow the water run
out.
DIMENSIONS
All dimensions in mm.
and the protective wire net.
threaded sleeve, screw back the nut and the lower bar.