Vaisala SPH10, SPH20 Technical data

SPH10/20 Static Pressure Heads for Minimizing Wind Induced Error
www.vaisala.com
Wind induced effects are one of the main sources of error when measuring barometric pressure. Variations due to strong and gusty wind can be overcome by using a static pressure head to ‘lter out’ the effect of dynamic pressure.
The Vaisala Static Pressure Head Series SPH10/20 are designed to minimize the errors caused by wind. The wind tunnel tested structure is both horizontally and vertically symmetrical. This design ensures reliable barometric pressure measurements in all weather.
Ideal for outdoor installations
Vaisala’s static pressure heads are available in two models: the Vaisala Static Pressure Head SPH10 is a basic version, and the Vaisala Static Pressure Head SPH20 is a heated version for reliable operation in snowy and icy conditions. The warmed SPH20 contains a thermostat that switches on the warming power at temperatures, where the risk of icing may occur.
Composed of ultraviolet stabilized PC plastics and offshore aluminium, the
SPH10/20 static pressure heads are durable and weather resistant.
The SPH10/20 protects against rain and condensed water, thus preventing capillary condensation of a water column in the pressure channel which results in pressure error. The drain holes in the lower plate allow rain and water to ow out. The static pressure heads have internal netting which prevents insects and debris from blocking the pressure channel.
Carefree maintenance
The SPH10/20 static pressure heads are easy to install and disassemble, service and clean – even at the installation site. Vaisala BAROCAP Digital Barometer PTB210 can be installed directly on top of the SPH10/20 static pressure heads. Other barometers can be connected to the heads with pressure tubing.
SPH10 and SPH20 are a perfect pair for all Vaisala barometers. They ensure an accurate and reliable measurement in all weather conditions.
®
The SPH10/20 is easy to install and connect. In the picture, a SPH10 is connected to a PTB210 barometer.
Features/Benefits
Minimizes wind induced error
Reliable barometric pressure
measurement in all weather
Wind tunnel tested structure
Easy-to-clean
Easy-to-install
Technical data
General
Operating temperature -60 ... +80 °C (-76 ... +176 °F) Weight
SPH10 800 g
SPH20 1360 g Material PC plastic, offshore aluminium Mounting with 2 bolts (M6 X 20 mm min) Hose connection barbed fitting for 4 mm I.D. hose
or Rp1/4 thread (parallel)
Dimensions
Dimensions in mm
SPH10
SPH20
Electrical connections M12 connector Power supply factory setting 12 V
changed connection 24 V
Thermostat switching temperature
On +4 °C (±3 °C)
+39.2 °F (±4.4 °F)
Off +13 °C (±3 °C)
+55.4 °F (±4.4 °F)
Power consumption during heating 70 W
SPH20
For more information, visit www.vaisala.com or contact us at sales@vaisala.com
Ref. B210907EN-A ©Vaisala 2009
This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice.