All manuals and user guides at all-guides.com
________________________________________________________________________________
VAISALA________________________________________________________________________ 1
Table of Contents
CHAPTER 1
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Contents of This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Version Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Documentation Conventions . . . . . . . . . . . . . . . . . . . . . . . .9
Product-Related Safety Precautions . . . . . . . . . . . . . . . . . . . 9
Recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Regulatory Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
License Agreement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
CHAPTER 2
PRODUCT OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Introduction to Vaisala RS92-SGP . . . . . . . . . . . . . . . . . . . . 13
CHAPTER 3
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Preparing the Balloon and Optional Sounding
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Balloon Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Optional Sounding Accessories . . . . . . . . . . . . . . . . . . . . . 20
Totex Parachute 5710-5 . . . . . . . . . . . . . . . . . . . . . . . 20
Radar Reflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Non-Totex Parachute. . . . . . . . . . . . . . . . . . . . . . . . . . 21
Unpacking the Radiosonde . . . . . . . . . . . . . . . . . . . . . . . . .23
Preparing the Sounding . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Connecting the Battery Set . . . . . . . . . . . . . . . . . . . . . . . . . 28
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Connecting the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Connecting the Dry-cell Battery Set with Switch . . . . . . . . 31
Checking the Connection. . . . . . . . . . . . . . . . . . . . . . . 35
Connecting the Water-activated Battery . . . . . . . . . . . . . . 36
Removing the Battery Case . . . . . . . . . . . . . . . . . . . . . . . . 39
Launching the Radiosonde . . . . . . . . . . . . . . . . . . . . . . . . . 39
Attaching the Unwinder . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Attaching the Unwinder to the Balloon. . . . . . . . . . . . . 40
Totex Parachute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Radar Reflector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Non-Totex Parachute. . . . . . . . . . . . . . . . . . . . . . . . . . 41
All manuals and user guides at all-guides.com
User's Guide ______________________________________________________________________
2 ___________________________________________________________________ M210295EN-H
Releasing the Balloon . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Checking the Reception . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Monitoring the Sounding with the Sounding System . . . .42
CHAPTER 4
STORAGE AND TRANSPORTATION . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Transportation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Transporting Lithium Batteries and RS92 Radiosondes . .44
CHAPTER 5
FAILURE REPORT AND WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Product Returns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Radiosonde Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Vaisala Radiosonde Warranty Statement . . . . . . . . . . . . .48
Storage Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Transportation and Handling . . . . . . . . . . . . . . . . . . . . 49
Criteria for Radiosonde Failures . . . . . . . . . . . . . . . . . 49
Making Warranty Claims . . . . . . . . . . . . . . . . . . . . . . . 50
APPENDIX A
SAFETY INSTRUCTIONS FOR BALLOON OPERATORS . . . . . . . . . . . .51
All manuals and user guides at all-guides.com
________________________________________________________________________________
VAISALA________________________________________________________________________ 3
List of Figures
Figure 1 Vaisala Radiosonde RS92-SGP . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 2 Loading Weights onto the Gas Nozzle. . . . . . . . . . . . . . . . . . . 16
Figure 3 Attaching the Balloon to the Gas Nozzle . . . . . . . . . . . . . . . . . 17
Figure 4 Inflating the Balloon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 5 Balloon Raises the Gas Nozzle . . . . . . . . . . . . . . . . . . . . . . . .18
Figure 6 Securing the Neck of the Balloon. . . . . . . . . . . . . . . . . . . . . . . 18
Figure 7 Removing the Balloon from the Gas Nozzle . . . . . . . . . . . . . .19
Figure 8 Folding the Neck of the Balloon . . . . . . . . . . . . . . . . . . . . . . . .19
Figure 9 Vaisala Radiosonde Sounding Accessories. . . . . . . . . . . . . . .22
Figure 10 Opening the Foil Bag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 11 Contents of the Radiosonde Package . . . . . . . . . . . . . . . . . . .24
Figure 12 Unwinder Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 13 Vaisala Ground Check Set GC25 . . . . . . . . . . . . . . . . . . . . . . 25
Figure 14 Radiosonde in the GC25 with the Communication Cable
Connected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Figure 15 Placing the Sensor Boom into Flight Position . . . . . . . . . . . . . 27
Figure 16 RSB511 Dry-cell Battery Set (Number 1) and
RSB611 Lithium Battery (Number 2) . . . . . . . . . . . . . . . . . . . .28
Figure 17 RSB912P Water-activated Battery. . . . . . . . . . . . . . . . . . . . . .29
Figure 18 Battery Package. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Figure 19 Battery Connector Shown with RSB611 . . . . . . . . . . . . . . . . . 30
Figure 20 Connecting the Battery Connector to the Radiosonde. . . . . . .30
Figure 21 Battery Package for Dry-cell Battery Set with Switch. . . . . . . .31
Figure 22 Battery Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Figure 23 Placing Battery Connector into Connector Holder, Part 1 . . . . 32
Figure 24 Placing Battery Connector into Connector Holder, Part 2 . . . . 33
Figure 25 Connecting the Radiosonde to the Battery Case. . . . . . . . . . . 34
Figure 26 Pressing Battery Case and Radiosonde Together. . . . . . . . . . 34
Figure 27 Green LED Light is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 28 Battery Package for Water-Activated Battery. . . . . . . . . . . . . .36
Figure 29 Battery Immersed in Water . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Figure 30 Battery in the Case, Waxed End Circled . . . . . . . . . . . . . . . . . 37
Figure 31 Connecting the Battery Connector to the Radiosonde. . . . . . .38
Figure 32 Removing the Battery Case . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Figure 33 Attaching the Unwinder to the Balloon. . . . . . . . . . . . . . . . . . .40
Figure 34 Lithium Battery Handling Label . . . . . . . . . . . . . . . . . . . . . . . .45
All manuals and user guides at all-guides.com
User's Guide ______________________________________________________________________
4 ___________________________________________________________________ M210295EN-H
All manuals and user guides at all-guides.com
all-guides.com
________________________________________________________________________________
VAISALA________________________________________________________________________ 5
List of Tables
Table 1 Manual Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Table 2 Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 3 Ordering Codes for Optional Sounding Accessories . . . . . . . . . .20
Table 4 RS92-SGP Battery Sets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
All manuals and user guides at all-guides.com
User's Guide ______________________________________________________________________
6 ___________________________________________________________________ M210295EN-H
All manuals and user guides at all-guides.com
Chapter 1 ________________________________________________________ General Information
VAISALA________________________________________________________________________ 7
CHAPTER 1
GENERAL INFORMATION
This chapter provides general notes for the manual and the product.
About This Manual
This manual provides information for operating Vaisala Radiosonde
RS92-SGP.
Contents of This Manual
This manual consists of the following chapters:
- Chapter 1, General Information: This chapter provides general notes for the manual and the product.
- Chapter 2, Product Overview: This chapter introduces the features and advantages of the radiosonde.
- Chapter 3, Operation: This chapter contains information that is needed to operate this product.
- Chapter 4, Storage and Transportation: This chapter provides information for the transport and storage of the product.
- Chapter 5, Failure Report and Warranty: This chapter presents information about the failure report and radiosonde warranty.
- Appendix A, Safety Instructions for Balloon Operators: This appendix contains details of safe and proper balloon preparation.
All manuals and user guides at all-guides.com
User's Guide ______________________________________________________________________
8 ___________________________________________________________________ M210295EN-H
Version Information
Related Manuals
Table 1 Manual Versions
Manual Code Description
M210295EN-H October 2012. This version. Updated for MW41. M210295EN-G May 2010. Previous version. Contains RS92-
SGPL. M210295EN-F October 2009. M210295EN-E Previous version
Table 2 Related Manuals
Manual Code Manual Name
DOC219110 Vaisala Radiosonde RS92 Quick Guide M210507EN AUTOSONDE AS14 Users Guide M210329EN Ground Check Set GC25 User's Guide M210488EN Vaisala DigiCORA® User's Guide M210547EN Digital Ozonesonde RS92 User's Guide M210616EN Radioactivity Sounding with Digital Vaisala
Radiosonde RS92 User's Guide M010024EN DigiCORA II MW15 User's Guide M210811EN Configuring and Operating MW11/15 Systems,
RS92 Radiosonde, and GC25 Using Cable
Connection
All manuals and user guides at all-guides.com
Chapter 1 ________________________________________________________ General Information
VAISALA________________________________________________________________________ 9
Documentation Conventions
Throughout the manual, important safety considerations are highlighted as follows:
Product-Related Safety Precautions
WARNING
Warning alerts you to a serious hazard. If you do not read and follow instructions very carefully at this point, there is a risk of injury or even death.
CAUTION
Caution warns you of a potential hazard. If you do not read and follow instructions carefully at this point, the product could be damaged or important data could be lost.
NOTE
Note highlights important information on using the product.
WARNING
Conduct soundings in a safe environment and in accordance with all applicable restrictions and regulations.
WARNING
Do not use the radiosonde in an area with power lines or other obstructions overhead. Make sure that you check the area for such obstructions before using the radiosonde.
WARNING
Do not use the radiosonde without consultation and cooperation with local and other applicable aviation authorities.
CAUTION
Do not modify the unit. Improper modification can damage the product or lead to malfunction.
CAUTION
Do not use the radiosonde for any purpose other than for soundings.
All manuals and user guides at all-guides.com
all-guides.com
User's Guide ______________________________________________________________________
10 __________________________________________________________________ M210295EN-H
Recycling
Regulatory Compliances
Vaisala Radiosondes RS92-SGP and RS92-D are in conformity with the following EU directive and with national legislation implementing this directive:
- 1995/EEC (Radio and Telecommunications Terminal Equipment) The conformity is shown by compliance with the following standards:
ERM:
- ETSI EN 302 054-1 V1.1.1. and
- ETSI EN 302-054-2 V1.1.1
EMC:
- ETSI EN 301 489-1 V1.8.1 and
- ETSI EN 301 489-3 V1.4.1
[EN 61000-4-2 and EN61000-4-3]
Recycle all applicable material.
Dispose of batteries and the unit according to statutory regulations. Do not dispose of with regular household refuse.
All manuals and user guides at all-guides.com
Chapter 1 ________________________________________________________ General Information
VAISALA_______________________________________________________________________ 11
License Agreement
All rights to any software are held by Vaisala or third parties. The customer is allowed to use the software only to the extent that is provided by the applicable supply contract or Software License Agreement.
All manuals and user guides at all-guides.com
User's Guide ______________________________________________________________________
12 __________________________________________________________________ M210295EN-H
All manuals and user guides at all-guides.com
Chapter 2 __________________________________________________________ Product Overview
VAISALA_______________________________________________________________________ 13
CHAPTER 2
PRODUCT OVERVIEW
This chapter introduces the features and advantages of the radiosonde.
Introduction to Vaisala RS92-SGP
The digital Vaisala Radiosonde RS92-SGP offers excellent data availability, accuracy of humidity, pressure, temperature, and wind measurement.
This radiosonde type features a GPS receiver for wind finding. The RS92-SGP has a silicon pressure sensor, heated twin humidity sensor and a small, fast temperature sensor. The RS92-SGP features easy additional sensor capability. The synthesizer-based transmitter is stable and uses a narrow bandwidth. The RS92-SGP is compliant with the European ETSI standard for digital radiosondes operating in the 400 MHz band, EN 302 054.
In addition to regular soundings, the RS92-SGP radiosondes can be used to conduct ozone and radioactivity soundings. When conducting an ozone sounding, an ozone sensor with an interface unit is connected to the radiosonde. When conducting a radioactivity sounding, an integrated interface and radioactivity sensor unit is connected to the radiosonde. Follow the procedures and guidelines in the relevant User’s Guides to conduct additional sensor soundings.
All manuals and user guides at all-guides.com
User's Guide ______________________________________________________________________
14 __________________________________________________________________ M210295EN-H
0705-015
Figure 1 Vaisala Radiosonde RS92-SGP
Vaisala Radiosonde RS92-SGP can be used with Vaisala Sounding Systems MW41, MW32, MW31 and MW21, and with MW11, MW12, and MW15.
1 = GPS antenna 2 = Battery case 3 = Additional sensor interface connector 4 = Antenna 5 = Temperature sensor 6 = Humidity sensors 7 = Sensor boom 8 = GC25 interface
All manuals and user guides at all-guides.com
all-guides.com
Chapter 3 ________________________________________________________________ Operation
VAISALA_______________________________________________________________________ 15
CHAPTER 3
OPERATION
This chapter contains information that is needed to operate this product.
General
It is essential that you carry out the pre-launch steps as instructed and always in the same way. Follow the instructions in the sections below and refer to Appendix A on page 51 for proper and safe balloon preparation.
The workorder for a sounding is as follows:
1. Prepare the balloon and optional sounding accessories.
2. Unpack the radiosonde.
3. Prepare the sounding.
4. Connect the battery.
5. Launch the radiosonde.
6. Monitor the sounding with the sounding system.
When conducting additional sensor soundings (ozone or radioactivity soundings), follow the procedures and guidelines in the relevant User’s Guides.
All manuals and user guides at all-guides.com
User's Guide ______________________________________________________________________
16 __________________________________________________________________ M210295EN-H
Preparing the Balloon and Optional Sounding Accessories
The balloon and the optional sounding accessories must be prepared before connecting the radiosonde battery and thereby activating the radiosonde. This is necessary because the radiosonde should be launched within 15 minutes of battery connection.
Balloon Preparation
Follow these steps to prepare the balloon:
1. Load weights that are needed to obtain the required lift onto the gas nozzle.
0705-020
Figure 2 Loading Weights onto the Gas Nozzle
WARNING
Read the safety instructions in Appendix A before proceeding. Normally the balloon-lifting gas (hydrogen or helium) is supplied in gas bottles, but hydrogen can also be produced with a hydrogen generator. Carefully study the operation and safety instructions for the gas bottle facilities or the hydrogen generator.
Take extreme caution when handling the inflated balloon.
WARNING
It is recommended that the balloon be prepared in a balloon-filling shed. The balloon-filling shed must be well ventilated so that possible gas leaks do not remain inside the shed, even in situations when there is no electricity.
All manuals and user guides at all-guides.com
Loading...