Vaisala MW41 Datasheet

Vaisala MW41 Datasheet

DigiCORAâ Sounding System MW41

Features

• Consistent, high quality data

• Easy integration to existing soundings network

• Increased flexibility through advanced networking options

• Easy and simple operation

• Quick configuration and modification of station parameters, also remotely

Vaisala MW41 System supports the world-class performance of Vaisala RS41 radiosonde family. This makes MW41 an excellent choice for both synoptical and research applications.

Vaisala DigiCORAâ Sounding System MW41 processes, analyses, archives, and relays sounding data. The system consists of a computer that runs Vaisala MW41 software and is connected to a sounding processing subsystem via a network adapter. MW41 software includes the sounding processing software running as services on a computer and an optional remote client for remote access/use.

Easy to integrate

Upgrading to MW41 from earlier Vaisala sounding systems is smooth and cost effective. The software is compatible with commonly used Windows operating systems and hardware, making it easy to integrate to most IT bases and helping to minimize maintenance costs. Connectivity with Vaisala Automatic Weather Stations allows using highly accurate surface weather information as reference, which makes operation simpler and less sensitive to human error.

Flexible to use

As MW41 user interface is separated from other software functionalities, it can be operated from anywhere within your network. This allows, for example, managing sounding operations remotely, away from the sounding station. Additionally, all network users can access sounding data, remotely.

The standard MW41 software package includes all features needed to perform synoptic soundings. For more advanced sounding needs, like ozone sounding capability or extended graphics, optional modules are available. The system can be tailored for specific needs of a sounding station.

Intuitive to operate

MW41 follows the radiosonde preparation process, minimizing the need for user input and interaction. When the user needs to act, using the system is made easier with clear status indicators and animations, and

a software help is available for additional

assistance. As operating the system is highly intuitive, training users is faster. Access to specific functionalities can be defined by utilizing user groups and their related privileges.

Quick to configure

Configuring MW41 for operation is easy. The user interface supports quick configuration of station parameters, message creation, and parameter sending. The system can also be configured remotely.

MW41 validates sounding data to make sure it is of high quality. The system can create WMO messages and special text reports using the validated data, and the data is also available in XML format.

Technical data

Compatibility

Radiosonde

RS41-SG

 

RS41-SGP

 

RS41-SGM

 

RS41-D

 

 

Special sensor

Ozone sensors:

 

ECC 6A ECC

 

Z ECC

 

 

 

Telemetry

Frequency band

400.15 … 406 MHz

 

 

Tuning step (user-adjustable)

10 kHz

Error detection and correction

Reed-Solomon

 

 

Telemetry range (using directional

Up to 350 km (217.5 mi)

antenna)

 

 

 

Minimum system requirements for sounding workstation

Computer

PC delivered by Vaisala includes:

 

• Pre installed DigiCORA Sounding

 

Software

 

• System recovery tools, including

 

USB drive with recovery image

 

• Optional Edgeport serial extension

 

Optionally, any PC that fulfills the

 

requirements below can be used.

 

 

Operating system

• Windows 10 Pro 64-bit (English)

Web browser

• Microsoft Edge latest version

 

(English)

 

• Mozilla Firefox latest version

 

(English)

 

• Google Chrome latest version

 

(English)

 

 

Processor

Intel Pentium Dual Core or equivalent

 

(Quad Core recommended)

Memory

8 GB RAM

 

 

Hard disk space

160 GB

Display resolution

1366 × 768 (minimum)

 

 

DVD-ROM drive

 

USB port for Ground Check Device RI41

 

 

 

Optional serial ports

Either integrated or via USB/RS 232

 

converter.

 

1 for possible Automatic Weather

 

Station

Ethernet adapter

 

 

Speakers integrated either into computer or display

Remote client PC

Using devices that fulfill the same

 

requirements as for Sounding

 

Workstations is recommended.1)

1)It is likely that devices with lower hardware specifications, other operating systems, or other browsers can be used.

Vaisala Sounding Processing Subsystem

Software defined radio technology

Code correlating GPS

Meteorological messages

TEMP messages

TEMP FM35-XI, TEMP SHIP FM36-XI,

 

TEMP MOBIL FM38-XI

 

 

PILOT messages

PILOT FM32-XI, PILOT SHIP FM33-XI,

 

PILOT MOBIL FM34-XI

BUFR messages

BUFR 3’09’050 and BUFR 3’09’051

 

(for PILOT and High resolution data)

 

BUFR 3’09’052 and BUFR 3’09’057

 

(for TEMP and High resolution data)

 

BUFR 3’09’056 (for descending

 

sounding after balloon burst)

 

 

Advanced option

CLIMAT TEMP FM 75-X

 

BUFR 3’09’053 (DROP BUFR)

Special sensor option

NILU, WOUDC

 

 

Defense messages option

METCM STANAG 4082, METB2/

 

METB3 STANAG 4061, METFM

 

STANAG 2103, METSR/METSRX,

 

METTA STANAG 4140, METEO 11

 

 

Antennas

Directional UHF antenna (automatic direction control)

Omnidirectional UHF antenna

Portable antenna for UHF and GPS

GPS antenna

Advanced Multipath Rejection GPS antenna

Ground check set

RI41 and RI41 B. See separate datasheets for details.

Operating environment

Indoor equipment

 

 

 

 

Operating temperature

+10 … +35 °C (+50 … +95 °F)

Storage temperature

−40 … +65 °C (−40 … +149 °F)

 

 

Operating humidity

10 … 90 %RH

Storage humidity

5 … 95 %RH

 

 

 

Outdoor equipment

 

 

Operating temperature

−40 … +55 °C (−40 … +131 °F)

 

 

Storage temperature

−50 … +71 °C (−58 … +160 °F)

Operating humidity

0

… 100 %RH

 

 

 

Storage humidity

0

… 100 %RH

Operating wind speed

0

… 65 m/s (0 … 145 mph)

 

 

Operating precipitation

Unlimited

 

 

 

 

Published by Vaisala | B211221EN-J © Vaisala Oyj 2020

www.vaisala.com

All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners.

Any reproduction, transfer, distribution or storage of information contained in this document is strictly

 

prohibited. All specifications — technical included — are subject to change without notice.

Loading...