HMP155 with an additional temperature probe and optional Stevenson screen installation kit.
Features
•Vaisala HUMICAPâ180R sensor: superior long-term stability
•Optional warmed humidity probe and chemical purge
•Plug-and-play
•USB connection for service use
•Use with DTR13 and DTR503 radiation shields and a Stevenson screen
•Weather-proof housing IP66
•Optional, fast temperature probe
•Different output possibilities: voltage, RS-485, resistive Pt100
•Applications: meteorology, aviation and road weather, instrumentation
HUMICAPâ Humidity and
Temperature Probe HMP155
Vaisala HUMICAPâ Humidity and Temperature Probe HMP155 provides reliable humidity and temperature measurement. It is designed especially for demanding outdoor applications.
Long-term stability
HMP155 uses the proven Vaisala HUMICAPâ180R sensor that has excellent stability and withstands well harsh environments. The probe structure is solid and the sensor is protected by default with a sintered teflon filter, which gives maximum protection against water, dust, and dirt.
Warmed probe and highhumidity environment
Measuring humidity reliably is challenging in environments where humidity is near saturation. Measurements may be corrupted by fog, mist, rain, and heavy dew. A wet probe may not give an accurate measurement in the ambient air.
This is an environment to which Vaisala has designed this patented, warmed probe for reliable measurements. As the sensor head is warmed continuously, the humidity level inside it stays below the ambient level. Thus, it also reduces the risk of condensation forming on
the probe.
Fast measurements
With its fast response time,
the additional temperature probe for HMP155 is ideal for measuring in environments with changing temperatures. The membrane filter speeds up the relative humidity measurement.
Long lifetime
Protecting the sensor from precipitation, and scattered and direct solar radiation increases its lifetime. Thus, Vaisala recommends installing HMP155 in one of the following radiation shields: DTR503, DTR13, or Stevenson screen. For
the additional temperature probe,
an installation kit is available for Vaisala DTR502 Radiation Shield.
Calibration
The probe can be calibrated using a computer with a USB cable, with the push buttons, or with the MI70 indicator.
Technical Data
HMP155 humidity measurement performance
Sensor |
HUMICAPâ180R and 180R2 for typical |
|
applications |
|
HUMICAPâ180C and 180R2C for |
|
applications with chemical purge |
|
and/or warmed probe |
|
|
Observation range |
0 … 100 %RH |
Response time at +20 °C (+68 °F) in |
63 %: 20 s |
still air with sintered Teflon filter |
90 %: 60 s |
|
|
Factory calibration uncertainty at |
±0.6 %RH (0 … 40 %RH) |
+20 °C (+68 °F)1) |
±1.0 %RH (40 … 95 %RH) |
Accuracy (including non-linearity, hysteresis, and repeatability)
At +15 … +25 °C (+59 … +77 °F) |
±1 %RH (0 … 90 %RH) |
|
±1.7 %RH (90 … 100 %RH) |
At −20 … +40 °C (−4 … +104 °F) |
±(1.0 + 0.008 × reading) %RH |
|
|
At −40 … −20 °C (−40 … −4 °F) |
±(1.2 + 0.012 × reading) %RH |
At +40 … +60 °C (+104 … +140 °F) |
±(1.2 + 0.012 × reading) %RH |
|
|
At −60 … −40 °C (−76 … −40 °F) |
±(1.4 + 0.032 × reading) %RH |
|
|
1)Defined as ±2 standard deviation limits. Small variations possible (see also the calibration certificate).
HMP155 temperature measurement performance
Sensor |
Pt100 RTD element, Class F 0.1 |
|
IEC 60751 |
|
|
Observation range |
−80 … +60 °C (−112 … +140 °F) |
Response time for additional |
63 %: < 20 s |
temperature probe in 3 m/s (7 mph) air |
90 %: < 35 s |
flow |
|
|
|
Other measured variables |
Dew point / frost point temperature, |
|
wet bulb temperature, mixing ratio |
Accuracy with voltage output |
|
|
|
At −80 … +20 °C (−112 … +68 °F) |
±(0.226 - 0.0028 × temperature) °C |
At +20 … +60 °C (+68 … +140 °F) |
±(0.055 + 0.0057 × temperature) °C |
|
|
Accuracy with passive (resistive) output |
|
According to Tolerance Class AA |
±(0.1 + 0.0017 × |temperature|) °C |
IEC 607511) |
|
Accuracy with RS 485 output |
|
At −80 … +20 °C (−112 … +68 °F) |
±(0.176 - 0.0028 × temperature) °C |
|
|
At +20 … +60 °C (+68 … +140 °F) |
±(0.07 + 0.0025 × temperature) °C |
|
|
1)Tolerance Class AA IEC 60751 corresponds to IEC 751 1/3 Class B
HMP155 accuracy over temperature range: voltage and RS 485
HMP155 operating environment
Operating temperature for humidity |
−80 … +60 °C (−112 … +140 °F) |
measurement |
|
|
|
Storage temperature |
−80 … +60 °C (−112 … +140 °F) |
Operating humidity |
0 … 100 %RH |
|
|
EMC (industrial environment) |
EN/IEC 61326-1, EN 55022 |
IP rating |
IP66 |
HMP155 inputs and outputs
Operating voltage |
7 … 28 VDC |
|
|
|
|
Minimum operating voltage |
0 |
… 1 V output or RS 485: 7 V |
|
0 |
… 5 V output, or warmed probe: |
|
12 V |
|
|
0 |
… 10 V output, chemical purge, or |
|
XHEAT: 16 V |
|
Outputs |
Voltage output: 0 … 1 V, 0 … 5 V, |
|
|
0 |
… 10 V |
|
Resistive Pt100 4 wire connection |
|
|
RS 485 |
|
|
|
|
Average power consumption (+15 VDC, |
0 |
… 1 V output: < 3 mA |
load 100 kΩ) |
0 |
… 10 V output: +0.5 mA |
|
RS-485: < 4 mA |
|
|
During chemical purge: Maximum |
|
|
110 mA |
|
|
With warmed probe: Maximum |
|
|
150 mA |
|
Settling time at startup |
Voltage output: 2 s |
|
|
RS-485: 3 s |
HMP155 mechanical specifications
Dimensions (H × W) |
|
279 × 40 mm (10.9 × 1.6 in) |
Weight |
|
86 g (3.0 oz) |
Length of additional T probe cable |
2 m (6 ft 7 in) |
|
Connection |
|
8-pin male M12 connector |
Connection cables |
|
3.5 m (11 ft 6 in), 10 m (32 ft 10 in), |
|
|
30 m (98 ft 5 in) |
Maximum wire size |
|
0.129 mm2 (26 AWG) |
Service cables |
|
USB connection cable |
|
|
MI70 connection cable |
Materials |
|
|
Filter |
|
Sintered Teflon or membrane |
Housing |
|
Polycarbonate (PC) |
Additional temperature probe |
Stainless steel AISI 316L |
|
Cable |
|
PUR |
|
279 [10.98] |
|
|
|
266 [10.47] |
<![if ! IE]> <![endif]>[1.57] |
|
|
<![if ! IE]> <![endif]>40 |
<![if ! IE]> <![endif]>24 [0.94] |
86 [3.39] |
|
Dimensions in mm (inches)
Published by Vaisala | B210752EN-H © Vaisala Oyj 2020
All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. www.vaisala.com Any reproduction, transfer, distribution or storage of information contained in this document is strictly
prohibited. All specifications — technical included — are subject to change without notice.