Vaddio Image Controller CeilingVIEW HD-18 DocCAM User Manual

C
C
C
C
U
U
I
I
M
M
A
A
GEE
G
C
C
O
O
NTT
N
R
OLLLLEE
R
O
R
R
*
FFO
*
O
R
R
C
EEIILLIINNG
C
Part Number: 999-1105-023 Worldwide
(Includes North American, Euro and UK Power Cables)
Front Panel
Rear Panel
*Also compatible with Vaddio HD-18 and HD-20 PTZ cameras using the CeilingVIEW HD HideAway motorized lift system and enclosure.
G
VII
V
E
E
W
W
CeilingVIEW HD-18 DocCAM - Sold Separately
H
H
D--1188
D
D
D
OCC
O
C
C
A
A
M
M
©2011 Vaddio - All Rights Reserved. CCU Image Controller for CeilingVIEW HD-18 DocCAM - Document 342-0197 Rev. A
CCU Image Controller for CeilingVIEW HD-18 DocCAM
Inside Front Cover - Blank
CCU Image Controller for CeilingVIEW HD-18 DocCAM - Document 342-0197 Rev. A Page 2 of 12
CCU Image Controller for CeilingVIEW HD-18 DocCAM
p
CCU Image Controller for CeilingVIEW HD-18 DocCAM
Front Panel View:
Rear Panel View:
Overview:
The CCU Image Controller was designed to provide color/image control to the CeilingVIEW HD-18 DocCAM packages. It is also can be used as an image controller for the HD-18 or HD-20 PTZ cameras used in the CeilingVIEW HD HideAway motorized lift system. This CCU Image Controller differs from the original Quick-Connect CCU in that it does not provide power to the camera, nor does it have the HSDS™ differential video I/O. The power and video are handled by the HD-18 Quick­Connect - SR Interface or the Quick-Connect DVI/HDMI - SR Interface packaged with the CeilingVIEW HD-18 DocCAM. The CCU Image Controller works in conjunction with the Control I/O of each of the Quick­Connect SR Interfaces allowing image control including Detail (sharpness), Color (red and blue gain), White Balance (auto/manual), Iris (auto/manual), Gain, Pedestal, Chroma, Gamma, Knee and allows for three (3) preset scenes
Intended Use:
Before operating the device, please read the entire manual thoroughly. The system was designed, built and tested for use indoors, and with the provided power supply and cabling. The use of a power supply other than the one provided or outdoor operation has not been tested and could damage the camera and/or create a potentially unsafe operating condition.
Important Safeguards:
Read and understand all instructions before using. Do not operate any device if it has been dropped or damaged. In this case, a Vaddio technician must examine the product before operating. To reduce the risk of electric shock, do not immerse in water or other liquids and avoid extremely humid conditions.
Save These Instructions:
The information contained in this manual will help you install and operate your product. If these instructions are misplaced, Vaddio keeps copies of Specifications, Installation and User Guides and product drawings for the product line on the Vaddio website. These documents can be downloaded from www.vaddio.com free of charge.
.
CeilingVIEW HD-18 DocCAM - Sold Separately
Use only the power supply provided with the system. Use of any unauthorized power supply will void any and all warranties.
Please do not use “pass-thru” type RJ-45 connectors. These pass-thru type connectors do not work well for professional installations and can be the cause of intermitten t connections which can result in the RS-232 control line failing and locking up, and/ or compromising the HSDS™ signals. For best results please use standard RJ-45 connectors and test all cables for proper
in-outs prior to use and connection to Vaddio product.
CCU Image Controller for CeilingVIEW HD-18 DocCAM - Document 342-0197 Rev. A Page 3 of 12
CCU Image Controller for CeilingVIEW HD-18 DocCAM
Unpacking:
The 999-1105-022 System is Packaged as a Worldwide* Product and Includes:
One (1) 998-1105-022 CCU Image Controller for CeilingVIEW HD-18 DocCAM  One (1) 12 VDC, 1.0 Amp Switching Power Supply  One (1) North American AC Cord Set  One (1) Euro AC Cord Set  One (1) UK AC Cord Set  One (1) Manual
*Worldwide Packages contain North American and International Power Cords
CCU Image Controller Front Panel Controls (left to right):
Tally Light:
The blue LED tally light on the front panel is tied to the tally contacts on the rear panel allowing the user to easily track which CCU is being used in a multi-camera system by supplying a simple contact closure (i.e. from ProductionVIEW Precision Camera Controller or ProductionVIEW HD).
LCD Display:
Backlit (blue) display indicates which parameter (iris, detail, etc.) is being adjusted. When a rotary encoder is moved, the name of the control being adjusted and the value of that assigned parameter will be displayed.
Scenes A, B & C:
Three camera adjustment scenes (A, B & C) can be stored into microprocessor memory. When lit (backlit blue SPDT button), the scene is activated. To store a scene, the user adjusts the controls and touches and holds the scene button down until the button blinks.
Detail:
The Detail control sharpens or softens objects in the frame.
Red & Blue Gain Controls:
The Red and Blue Gain encoders adjust the red and blue gain of the signal when AWB is disengaged.
AWB:
The Automatic White Balance controls/adjusts the color levels automatically when engaged. Turn off AWB to manually adjust the Red and Blue levels, as well as Red, Green and Blue Enhance.
SHIFT:
Pressing Shift illuminates the button and changes the Pedestal adjustment knob to Knee adjustment. Knee adjustment allows bright objects that are easily overexposed to be reproduced more accurately. Pressing the Shift button a second time turns the light off, and the knob reverts to Pedestal adjustment.
Pedestal / Knee, Chroma & Gamma:
The Pedestal adjustment controls the absolute black level of an image. Chroma controls the overall color of the image being captured. Gamma adjusts the overall brightness of an image. See SHIFT for information on Knee.
Auto Iris:
The Auto Iris mode automatically adjusts the iris and gain of the camera. To manually adjust the iris or gain, turn off this control.
Manual Iris:
The Manual Iris control allows the user to set the iris manual to one of the 18 settings available.
Gain:
The Gain control boosts the signal level when the iris is open all the way, and there is not enough lighting available. To manually adjust the Gain, Auto Iris must be off.
CCU Image Controller for CeilingVIEW HD-18 DocCAM - Document 342-0197 Rev. A Page 4 of 12