RIGHT PRODUCT. RIGHT PLACE. RIGHT TEMPERATU R E. SINCE 1 962.
USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Modular 3000 Series • 3018WC • 18" Wine Captain ® Model
USER GUID E
u - l i n e. c o m
Contents
SAFETY • INSTALLATION & INTEGRATION • OPERATI N G INSTRUCTIONS • MAINTENANCE • SERVICE
Intro
Safety
Safety and Warning
Disposal and Recycling
Installation
Environmental Requirements
Electrical
Cutout Dimensions
Product Dimensions
Side by Side Installation
Anti-Tip Bracket
General Installation
Integrated Panel Dimensions
Integrated Grille / Plinth Dimensions
Cleaning
Cleaning Condenser
Wine Rack Installation
Extended Non-Use
Service
Troubleshooting
Warranty
Integrated Panel Installation
Grille / Plinth Installation
Door Swing
Door Stop
Door Adjust
Operating Instructions
First Use
Control Operation
Sabbath Mode
Airflow and Product Loading
U-Line Wine Guide
Recommended Wine Storage
Maintenance
USER GUIDE
u- li n e . c om
WEL C OME T O U-LINE
C o ngr a tulati ons on y o ur U-Lin e pu rch a s e . Y o u r p r oduc t com e s fr om a c o mpa n y wi th ov er fiv e deca des a n d thr ee genera ti ons
o f p r e m i u m mo d u lar i c e ma ki n g , r e f r i g e r a t io n , an d wi ne pre s erv a tion exp e rience . U-Line co nt in ues t o b e th e Am er ic an
lea d er , del i v e r i n g v e r s a t i l it y an d f l exi b il ity f o r mul t i p l e a p pl ic ati on s in cl udi n g resi den t i a l , ligh t commerc ia l, ou tdoor a n d m arine
use . U-Li ne’ s c o mpl e te produc t coll ec ti on in clud es modu lar Wi ne C a pt ai n
Crescent I c e Mak e rs , Glass & Solid Door R e fr igerators , Drawer Models , F r eezers , and Combo ® Models .
U-Li ne has ca pt iv a t ed those wi th a n a p prec i ati on f o r t h e fi ner things wi th ex c e pti o na l func ti ona l i t y , st yle, i n s p ir ed inno v a tio ns
and a ttenti o n to e v en the s m all e st det a il s . W e ar e known a n d r e s p ected for ou r un wa v e r i n g dedication to prod uct design ,
qua l i ty and s e lect ion. U-Line i s hea d quar ter e d in Milwauk e e , Wis c ons i n and h a s s h ipped produ c t to fiv e con t inen ts for o v er
two decades and is prou d to ha v e the opportun ity to s h ip to y o u.
PR ODU C T INFORMA T ION
L o oking for ad dition al information on y o ur product? User Guides , Qu ick R e f e r e nce Guides , CAD D r awings , Compliance
Docum e nt ation, and Product W a rr anty in formation ar e all a v ailable for r e f e r e nce and download at u-l i ne . c om.
®
Models , Be v e rage Centers , Clear I c e Machines ,
PR OPER TY D A MA GE / INJUR Y CONCERNS
In the unlik e l y e v ent property dam a ge or pers onal injury is s u s p ected r e la ted to a U-Line produc t, plea se t a k e the fol l owi n g
st eps :
1. U-Li ne Cust omer C a r e mus t be c o n tac ted i mmedi a t el y a t +1 .8 0 0 . 7 7 9 . 2 54 7.
2 . Serv i c e or r e p a i r s per f orm e d on th e u n i t w i t h ou t pri o r w r it t e n app r o v a l f r om U - L i n e is n o t perm it ted . If th e u n i t ha s been
alter e d or r e pair ed in th e field withou t pr ior written a p prov a l from U-Line , c l ai ms w i ll not be eligibl e .
SER V ICE IN FORMA T ION
Answers to Custom er F r equently Ask e d Qu estions ar e a v a i l able at u-li ne . c om un der Cu stomer C a r e or y o u ma y c o nt act our
Cu s t omer Care grou p di r e ct ly , c o nt a c t in for m at ion below.
G E N E RAL I N QU IR IE S
U-Li ne Corpora t i o n
89 00 N. 5 5th St r eet
Mil w auk e e, Wi sc ons i n 5 3 2 23 USA
Monda y - F r i d a y 8 : 0 0 am to 4:30 pm CST
T : +1. 4 1 4 .3 54 .0 300
F : +1. 4 14 .3 54 . 7 9 0 5
Ema i l: s a l e s@ u- li ne . c om
u- li ne . c om
SER V ICE & P A R T S A SSIST ANCE
Monda y - F r i d a y 8:0 0 a m to 5:30 pm CST
T : +1.8 00 .7 79 .25 4 7
F : +1. 4 1 4 . 354 .5 69 6
Ser v i c e Emai l: on li nes e rvic e@u - line . c om
P a rt s Ema i l: onli nep a rt s@ u- li ne . c om
CONNEC T WITH US
Designed, engineer ed an d ass e mbled in WI, US A
Intr od uc ti on 1
USER GUIDE
u- li n e . c om
SA FETY • I NSTALLATION & INTE GRATION • OPER ATI NG INS TRUCTIONS • MAINTENANCE • SE RVICE
Safety and Warning
Please read all inst ructi o ns bef o re inst alling,
operating, or serv icing the appliance.
U s e th is a ppl ia nc e f o r it s in ten d ed purp ose onl y an d f o l l ow
these g e neral p r ecaution s with thos e li sted th roug hout th is
gu ide:
SA FETY ALERT DEFINITIONS
Throughout this gui d e are s a f e ty it ems la beled wi th a
Dan g er, Warni ng or C a u t i o n based on the ris k type:
DANGER
!
Danger means that fai l ure to fol l ow this safet y
stat ement will result in se ve re per son al inj u ry o r
death .
DANGER
!
This uni t contains R600a (Isobut ane) which is a
flam mab l e hydro c arbon . I t is safe for regular
use. Do n o t us e sharp objects to expedite
defr osting. D o not ser v ice wi thout consul ting the
“R 6 0 0 a sp ec i f ic a t i o ns” s e c t io n in c l u d e d in th e
U s er Guide. D o not damage the r e f r iger ant
circuit.
WARNING
!
Serv ice must be done b y factory auth orized
service person nel. Any pa rts shall be rep l aced
with li ke components. Fa ilure to compl y could
increase th e risk of p ossible ignition du e to
incorrect parts or imp r oper service.
WARNING
!
Warning means that fa ilure to fol l ow this safet y
statement cou l d resu lt in seriou s pers onal injury
or d e ath.
CAUTION
!
Ca ut io n mea n s t h at fail ur e t o follow this saf e ty
statement may result in minor or mod e rate
pe rs onal in ju ry , p r ope r ty or eq uipm en t dam a ge.
Safet y and Warnin g 1
USER GUIDE
u- li n e . c om
SA FETY • I NSTALLATION & INTE GRATION • OPER ATI NG INS TRUCTIONS • MAINTENANCE • SE RVICE
Disposal and Recycling
DANGER
!
RISK OF CH ILD ENTRAPMENT. Bef o r e you throw
away your old ref r igerator or freezer, take off
the d oors an d leave shelves in place so children
may not easily cli m b inside.
If the unit is being remov e d from s e rv ic e for di spos al,
check and obey a ll federal, sta t e a n d l o ca l regul ati ons
reg a rd in g the di sp os al an d recy cl i n g of r e fr ig erat i o n
appliances, and follow these steps com p letely:
1. Remove a ll consumable contents from the unit.
2. Unplug the elec tric al c o rd f r o m its s o cket.
3 . Remov e th e d o or (s )/ dra w er (s ).
Dis p osal and Re c y cli n g 1
USER GUIDE
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Environmental Requirements
Th is m o del is in ten d ed f o r in door/i nt eri o r ap pl ic at ion s onl y
and i s not to be us ed i n inst all ati ons t h a t are open/
exposed to natural elements.
Thi s un it is des i gn ed to op era t e betw een 5 0 ° F ( 1 0°C ) and
10 0°F (3 8°C) . H i gher ambien t t e mperat ures may reduce
th e un it ’s abil ity to rea c h lo w temperatures and/or redu ce
ice produ c tion on applicable mod e ls .
Fo r best perform a nce, keep the unit out of direct sunlig ht
and a w ay from heat generat i ng equi pment.
I n cl im at es w h ere h i gh h u m i di ty an d d e w poi n t s ar e
pres ent , c o nden sa ti on ma y ap pear on ou ts ide s urf ac es.
Thi s is c o ns ider ed n o rmal . T h e condensation wil l
evaporate when th e h u midity d r ops.
CAUTION
!
Damages caused by am bi en t tem p e r atur es of
40 °F (4 °C) or below are not co vered by the
warran ty.
E n v i ronmental Requirements 1
USER GUIDE
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Electrical
WARNING
!
S H O C K HA ZA RD — E l ectr ical Gr oun d ing
Required. Never att e mpt to repair or perform
maint e nance on the unit unt il t h e el ectricit y has
be en d i sconne cted.
Never rem o ve th e round g r ou ndin g pro n g from
the p l u g and never u s e a two-p r on g gro und in g
adapter.
A l te ring , cu tt ing or re mov i ng pow e r cord ,
re mov i ng power pl ug, or di rect wiri ng can cause
serious injury, fire, los s of property and/or lif e,
and wi ll v o id the warranty.
Nev e r use an extension cor d to connect power to
the unit .
A l ways k e e p you r wo rk in g are a d r y .
El ectrical inst allat i on must observe all sta t e and
local codes. This uni t requires connection to a
gr oun d ed ( t hr ee -pr o ng) , polarized receptacle
that h a s been placed by a qua lified el ectrician.
Th e u n it requ ires a grou nd ed and polar i zed 115 VA C,
60 Hz, 15A p o wer s u pply (nor mal hou s ehold cu rren t ). An
i n di vi dual, proper ly grou nded branc h ci rc ui t or ci rc ui t
breaker is recommen d ed. A G F CI (grou n d fault cir c u i t
i n terrup ter ) is u s u a lly not r e qui r ed for fi xed location
appliances and is not recommen d ed fo r you r un it becaus e
i t cou l d be pron e to nu is anc e tr ippi ng . H o wever, b e s ure
to c o ns ult you r loc a l codes .
See CUTOUT DIM E NS IONS for recomm ended re ceptacle
locat i on.
Electri c al 1
USER GUIDE
4"
(102 mm)
7"
(178 mm)
17-7/8"
(455 mm)
33-7/8"
Preferred location
for electrical outlet
is in adjacent
cabinet.
24"
(610 mm)
5/8"
(16 mm)
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
Cutout Dimensions
PREP AR E SITE
Y o ur U - Lin e p r od uc t h a s b een designed ex clusiv ely for a
bu il t - i n in st a l la ti on. Whe n bui l t - in , y o ur u n i t does n o t
r e quir e addit i onal ai r spa c e f o r top , si des , or r e a r .
How e v e r , th e f r on t gr il le mu st NO T be obs t r u c t ed.
Th e pr oduct is designed and manu factur ed for seamless
in tegr at ion i n th e spec if ied c u t o ut openi n g sh own , w h i c h
r e quir es pr ecise measurem en ts . T h e opening must be
sq uar e and plumb front to back . Alth ough n o t r e quir ed,
y o u ma y ch oos e to in cr ea se the o v erall cutout width for
eas e of ins t all ati on.
The Modula r 30 00 Seri es un its ar e engineer ed w i th a
v a ri ety of a d jus t ment f e a t ur es to hel p ens u r e a sea m l e ss
ins t all ati on. Adjus t able doors , le v e ling legs and gri lle wi ll
assi st in fi ne tu ni ng th e ins t allati on.
CUT O UT DI MENSIONS
Me t r ic mea s ur e m en t s r o un d e d a n d op t i mized .
Al l 3 0 0 0 Se r i e s m o de ls fu ll y integrate into o v erla y/f a ce
fra m e, i n s e t or European/frameles s c a bi net s tyl es and
inst all s e amles s ly into s t an dar d 24" (610 mm ) depth
ca bi net b a s e .
CAUTION
!
Un it c a n N O T be i n s t a l le d beh i nd a closed cab i net
door .
Cuto ut Dimensio ns 1
USER GUIDE
(856 mm to 881 mm)
17-3/4"
(450 mm)
3-5/8" to 4-5/8"
Not Including Handle
23-7/16" (590 mm)
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Product Dimensions
(92 mm to 118 mm)
33-11/16" to 34-11/16"
Product Dimensio ns 1
USER GUIDE
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Side-by-Side Installation
OT HER SITE R E QUIREMENTS
Si de -by - Side Instal lati on
Unit s mus t operat e from s e p a rate, properly grounded
elec tric al recepta c l e s pl aced ac cording to ea ch unit’ s
electrical sp ecifications requirem ents.
Cutout widt h for a si de-by - s i de i n s t a lla ti on is the t o ta l of
the wi dths lis t ed u n der C u tout Di men s i o ns i n eac h un it’s
Ins tal lat i on G u i d e. Ea ch door can be opened individually
( o ne at a ti me) w i th out i n t e rf eren ce.
Hi nge-by-Hinge Inst allat i on (Mullion)
Wh en i n s t alli ng two uni ts hi nge-by-hinge, 13 /16" (2 2 m m)
is req u ired for integr ated mod e ls . Additional space may be
need ed for any kn obs, pulls or handles i n stalled.
Stainless steel models which in clude the s t andard s t ai nless
handle will req u i r e 4-9/16" (1 16 mm) to allow both doors
t o open t o 90 ° at th e s a m e t i m e .
H o wever, to ens ure un obstruc ted d oor s w in g (open i n g
both doors at the s a me t i me), 1/4" ( 6 .4 mm) of s p a c e
need s to be main tain ed between the units.
Si de-by - Side Insta llat i on 1
USER GUIDE
Left Hinged C abinet
Right Hinged C abinet
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Anti-Tip Bracket
CAUTION
!
The ant i -tip brac ket must be in s t all e d to pr ev en t
the unit from ti pping w h en doors are fully
opened or excess w e igh t is placed on the front of
the unit .
The anti -t ip brac ket has mu lt ip le mou n t i n g opti ons .
Mou n ting will depen d on your partic ular cabin e t
c o nf igurat ion. L o ca te 3 #8x 5 /8 " sc rew s inc l uded wi th your
un it.
TOP MOUN T
SID E MOU N T
Si de moun t pos i tion i s us ed wh en you are un ab le to m o unt
the brac ket t o the unders i de of your c o untertop.
Fo r ea se of i n s t a lla tion, the an ti- t ip brack e t is pre- in stalled
in th e top moun t pos i tion .
1. Completely slide the unit in t o i t s posi ti on i n th e
cabi net. Be c e rtai n uni t h e igh t i s proper ly adju sted.
(See GENERAL INSTALLATIO N ).
2. Open door completel y. Ma ke c e rtai n door clear s
su rrou n di ng c a bi netry.
3. Us ing a 3 / 32" (2. 5 0 mm) dri ll bit , dri ll 3 pil o t hol e s 5/8"
(1 6 mm) deep into bot t om of counter top. Use the
anti -tip bra c ket a s a t e mpl ate.
4. Ins tal l 3 #8x 5 /8" s c rews into the pla t e usi n g a
#2 Phi l li ps h e ad sc rewdri ver.
1. Remove the pre-i n s t a lled an t i - t i p bra c k e t f r om th e top
mount posi tion a n d ali g n t h e bra c ket to t h e hi nge s i de
of the unit as shown above.
2. Reinst al l t h e 2 #8x 5 /8" s c rews i n t o the pla t e us ing a
#2 P h i l li ps h e ad sc rewdri ver.
3. Completely sl ide the unit in t o i t s posi ti on in th e
cabi net. Be c e rtai n uni t h e igh t i s proper ly adju sted.
(See GENERAL INSTALLATIO N ).
4. Open door completel y. Ma ke c e rtai n door clear s
su rrou n di ng c a bi netry.
5. Us ing a 3 / 32" (2. 5 0 mm) dri ll bit , dri ll 3 pil o t hol e s 5/8"
( 1 6 m m ) deep i n t o c a bin e tr y fr am e u s i n g t h e an ti -t ip
brac ket as a templa t e.
6. Ins tal l 3 #8x 5 /8" s c rews into the pla t e usi n g a #2
P h illip s head s c r e wd river.
Anti -T ip Bra c k e t 1
USER GUIDE
R o t ate Clockwise to raise r ear leg.
R o t ate Counter -Clockwise to lower leg.
R o t ate F ront Legs to Adjust
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
General Installation
LE VE LING INFO RMATION
1 . U s e a l e vel to con f i r m
the unit is lev e l. Lev e l
sh ould be placed alon g
top ed ge an d s i d e
edge as show n.
2. If the uni t i s not lev e l,
rem o ve gri l le and
adjust legs as
nec e ss ar y. U s e
includ ed tool to adj u st
the hei g ht of th e rear legs .
INSTALLATI ON
1. P l u g in the power/elec t ri cal c o rd.
2. G e nt ly pus h the uni t i n t o pos i ti on. Be c a reful not to
entangle the cord.
3. Re-check the l e veli ng, from front to back and side to
s i de. Ma ke any nec e ss ary adjus t ments . The uni t ’ s top
su rf ac e s h ou ld be a pprox im at ely 1/ 8" ( 3 m m ) bel o w
the c o unt e rt op.
4. Ins tal l t h e anti -t ip brac ket .
5. Remove the i n t e ri or packi n g materi al a n d w i pe out t h e
i n s i de of the unit wit h a clea n, wa ter-da mpened c l oth.
3 . C o nf irm t h e un it is l e v e l af ter ea ch adjust ment and
repeat the previous s t eps unti l t h e unit i s l e vel.
INSTALLA TION TIP
If the room floor is higher than the f l oor i n the cutout
opening, adjust the rear legs t o a c hiev e a tota l unit rear
height of 1 / 8" (3 mm) les s th an the opening’ s rear hei g ht.
Sh or ten the un it hei g ht in th e front by a d just ing the f r ont
legs. This a llows t h e unit to be gen t ly tipped in to the
opening . Adjust the front leg s t o l e vel th e uni t a f t e r it is
cor r ec tl y pos i t i on ed in the opening.
General Insta llat i on 1
USER GUIDE
BACK SURFACE MUST HAVE AMPLE FLAT SURFACE
TO MOUNT OVERLAY PANEL FLAT AND WITHOUT
INTERFERENCE
3/4"
(20 mm)
Integrated P anel
17-5/8"
(445 mm)
30"
(762 mm)
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
Integrated P a nel Di mensi o ns
Metric measu r em ents roun ded an d optimized.
INTEGRA T ED P A NEL
Due to diff eren ces in su rroun d ing cabinetr y the
pan e l ma y not per f ect l y alig n with door . The
procedure below is designed to pro v ide a
finished integrated panel that seamlessly
integrates wi th surrounding cabinetr y .
P a nel Prep aratio n
A f u l l i n t e grat ed door panel c o mpl e tely c o v e rs the door
f r am e and pr o v ides a bui l t - i n app e ara n c e .
The door panel must no t weigh more than 20 lb s
(1 0 k g).
Int e grat ed P a nel Dimensions
It i s impor t ant t o ensure that a ll dri lled holes are
drilled to the correct de pth in order to a v oid
split s i n the wood when hardware is instal led.
1. Cut the pa nels to the dimens ions listed in the d i agram
below .
2. Opti ona l : St ain or f i nis h pa nel to des i red st a i n or col o r .
Be sur e to closely fol l ow the instructions pro v ided b y
the manufac tur e r .
3. Opti ona l : Ins t a ll ha ndl e s a n d ha rdw a r e .
When appl ying an integr ated panel to a unit ,
ensure th at both sid e s are finished in order to
pre v ent warping. In some panel instal lati ons ,
the panel ma y be vis i b l e through th e g l as s while
the d oor is open.
Integr ated Pa ne l Dimensio ns 1
USER GUIDE
Top Design
and Insert Notch
Wooden Insert
Main Panel
Integrated Panel
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
HA NDLE LESS INT E GR A T ED DO OR P A NE L
The foll owing procedur e is d e si gned to p r o v id e a finishe d ,
handleless soli d panel for an 1 8 " (4 50 mm) door tha t
sea m less ly in teg r a t es wi th i t s sur r oun d in g ca bi net r y .
NO TE: Ma n y ca bi net manufac tur e rs provi d e a r e ady
s o lution f o r a ha ndlel e ss , in tegrated des i gn that c a n be
eas i l y applied to y o ur U-Li ne 300 0 Seri es model. Cons ul t
y o ur c a b i net manufactur e r for appli c able des i g n an d
ins t all ati on det a il s . The c a bine t ma nufa ct ur er ’ s s o lutio n to
this des i gn and i n t e grat ion det a i l w i ll oft e n r e sult i n a n
integrat ed panel s o luti on wh er ein the siz e of the panel
ma y r e s u lt in a heigh t dime nsi o n t a l l e r than what we
s p ec if y . T h i s ca n b e ac hi e v ed pro v ided the additional
height i s pos i t i oned ab o v e the app l iance door .
The integrated panel aligns with th e surround in g
cabinetr y an d, due to diff erences in cabin e tr y ,
ma y n o t align pe r f e c t l y with the d oor .
3. Prepar e the insert (s ) t h a t w i ll bac k up the handl e les s
des i gn . W ood en In ser t – Cu t 1/ 8" (3 m m ) t h i c k
wooden i n s e rt (s ) to t h e di mens ions below .
W o ode n i n ser t w i d t h W o o de n i n ser t h e ig ht
17-5/8" (44 5 mm) 3 -1/2 " (89 m m)
The appliance will need up to 3 4 -1 /2" (8 76 m m )
to the under s ide of the co unter to lea v e room for
le v e ling adj u st ment s .
A si ngle prepared panel wit h inser t must not
weigh more than 20 lbs (10 k g).
Int e grat ed P a nel Preparati o n
1. Cut the mai n pa nel to the dimensi o ns below . F o r
det a il s , see th e d r aw i n gs on th e n e xt p a g e .
Main p a n e l wi dth M ain panel hei g ht
17- 5/8" (44 5 m m ) 2 8 - 13/16" (732 mm )
2. Create the top des i gn for the ha ndl e less f e at ur e and
the 1 / 8" (3 mm) notch f o r the i n s e rt(s ) indica ted on
the T o p Det a il dr awing, on the n e xt p a ge .
4. Opti ona l : St ai n or finis h panel and wooden insert to
desi r e d s t ai n or color . Be s u re to clo s ely fo llow the
i n s t r u c t i o ns p r o v id ed by t h e ma nu fa ct urer .
If fin i s h ing pan e l or wo oden in ser t , all sides
m u s t be fin i s h ed to preve n t wa rp in g.
5. Att a ch the i n s e rt to the panel. W ood glue or equiv a l e nt
a d hes i v e sh oul d b e u s ed t o a ttac h in sert to pa nel .
Integr ated Pa ne l Dimensio ns 2
USER GUIDE
3/4" (20 mm)
28-13/16"
(732 mm)
2-3/4"
(70 mm)
2-3/4"
70 mm
R 5/8"
(R 16 mm)
1/8" (3 mm)
1/4" (6 mm)
Wooden Insert
Notch Depth: 1/8" (3 mm)
2-3/8"
(60 mm)
7/8" (22 mm)
Ref.
Top Detail
Insert Notch
Top Design
1/8" (3 mm)
3-1/2"
(89 mm)
17-5/8" (445 mm)
Wooden Insert Dimensions
17-5/8"
(445 mm)
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
Handleless Integra t ed P a nel Dimensions
Integr ated Pa ne l Dimensio ns 3