QUICK START GUIDE

Nugget Ice Machine • ADA, 1 & 3 Class

30635 Rev_C

QUICK START GUIDE

u-line.com

WELCOME TO U-LINE

Congratulations on your U-Line purchase. Your product comes from a company with over five decades of premium modular ice making, refrigeration, and wine preservation experience. U-Line creates products focused on functionality, style, and inspired innovations — paying close attention to even the smallest details. Applications include residential, outdoor, ADA height compliant, marine, and commercial. Complete product categories include Beverage Centers, Wine Refrigerators, Ice Machines, Refrigerators, Freezers, and Dispensers.

Our advanced refrigeration systems, large and flexible capacities, and Built-In to Stand Out® clean integrated look allow you to preserve the right product, in the right place, at the right temperature. Since 2014, U-Line has been part of the Middleby family of brands. All products are designed, engineered, and assembled in Milwaukee, Wisconsin, USA, and select products are available worldwide.

PRODUCT INFORMATION

Looking for additional information on your product? User Guides, Spec Sheets, CAD Drawings, Compliance Documentation, and Product Warranty information are all available for reference and download at u-line.com.

PROPERTY DAMAGE / INJURY CONCERNS

In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following steps:

1.U-Line Customer Care must be contacted immediately at +1.414.354.0300.

2.Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit ha been altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.

GENERAL INQUIRIES

U-Line Corporation

8900 N. 55th Street

Milwaukee, Wisconsin 53223 USA Monday - Friday 8:00 am to 4:30 pm CST T: +1.414.354.0300

Email: sales@u-line.com u-line.com

CONNECT WITH US

SERVICE & PARTS ASSISTANCE

Monday - Friday 8:00 am to 4:30 pm CST T: +1.414.354.0300

Service Email: onlineservice@u-line.com

Parts Email: onlineparts@u-line.com

Designed, engineered and assembled in WI, USA

2

QUICK START GUIDE

u-line.com

This Quick Start Guide covers the basics of installation and general use of your product.

CONTENTS

Safety and Warning

4

Environmental Requirements

5

Electrical

5

Water Hookup

6

Drain

8

Door Swing

9

Door Adjustments

10

General Installation

13

Integrated Panel Installation

14

Control Operation

15

First Use

16

Ice

17

Cleaning

17

Warranty

19

For more details, see the complete User Guide & Service Manual on u-line.com.

D

e

 

 

 

s

 

 

d,

and as embl

ed

in

re

 

 

 

 

 

 

b

 

 

 

 

oved y end co

 

 

rem

 

nsu

 

be

 

 

 

me

 

to

 

 

 

 

ro

 

 

 

 

 

nly

21 year + 1 with registration*

*

tails

visit

 

u-line.com forde

U

S

A

This product is eligible for an additional one-year warranty at no charge when you register your product on u-line.com. See complete warranty for details.

3

QUICK START GUIDE

u-line.com

Safety and Warning

NOTICE

Please read all instructions before installing, operating, or servicing the appliance.

Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide:

SAFETY ALERT DEFINITIONS

! DANGER

This unit contains R600a (Isobutane) which is a flammable hydrocarbon. It is safe for regular use. Do not use sharp objects to expedite defrosting. Do not service without consulting the

“R600a specifications” section included in the

User Guide. Do not damage the refrigerant circuit.

Throughout this guide are safety items labeled with a Danger, Warning, or Caution based on the risk type:

! DANGER

Danger means that failure to follow this safety statement will result in severe personal injury or death.

! WARNING

Service must be done by factory authorized service personnel. Any parts shall be replaced with like components. Failure to comply could increase the risk of possible ignition due to incorrect parts or improper service.

! WARNING

Warning means that failure to follow this safety statement could result in serious personal injury or death.

CALIFORNIA PROPOSITION 65

This product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm.

www.P65warnings.CA.gov

! CAUTION

Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property, or equipment damage.

4

QUICK START GUIDE

u-line.com

Environmental Requirements

This model is intended for indoor/interior applications only and is not to be used in installations that are open/ exposed to natural elements.

This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models.

For best performance, keep the unit out of direct sunlight and away from heat generating equipment.

In climates where high humidity and dew points are present, condensation may appear on outside surfaces. This is considered normal. The condensation will evaporate when the humidity drops.

NOTICE

Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three-prong), polarized receptacle that has been placed by a qualified electrician.

The unit requires a grounded and polarized 115 VAC,

60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. A GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because it could be prone to nuisance tripping. However, be sure to consult your local codes.

! CAUTION

Damages caused by ambient temperatures of 40°F (4°C) or below are not covered by the warranty.

Electrical

SHOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected.

Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.

Altering, cutting or removing power cord, removing power plug, or direct wiring can cause serious injury, fire, loss of property and/or life, and will void the warranty.

Never use an extension cord to connect power to the unit.

Always keep your working area dry.

5

QUICK START GUIDE

u-line.com

Water Hookup

PREPARE PLUMBING

The water valve uses a standard 1/4” (6.35 mm) compression fitting. U-Line recommends using accessory water hook up kit – part # 80-54674-00. The kit includes a 10’ (3 m) braided flexible water supply line and a brass hose fitting.

! CAUTION

Plumbing installation must observe all state and local codes. All water and drain connections

MUST BE made by a licensed/qualified plumbing contractor. Failure to follow recommendations and instructions may result in damage and/or harm.

Water Supply Connection

! CAUTION

Do not use any plastic water supply line. The line is under pressure at all times. Plastic may crack or rupture with age and cause damage to your home.

Do not use tape or joint compound when attaching a braided flexible water supply line that includes a rubber gasket. The gasket provides an adequate seal – other materials could cause blockage of the valve.

Failure to follow recommendations and instructions may result in damage and/or harm, flooding or void the product warranty.

Use new hose set. Do not reuse old hose set.

When connecting the water supply, please note the following:

Before installing the unit and connecting to the cold water supply, review the local plumbing codes.

The water pressure should be between 20 and 120 psi

(138 and 827 kPa).

Water has less than 400 mg/L (ppm) total dissolved solids and hardness level below 200 mg/L (ppm) — i.e., below 12 grains per gallon. Check by using TDS meter or consulting with local water company.

TDS and/or water hardness above these limits should be treated with a reverse osmosis system or other filtration system.

Softened water is not recommended as it may result in softer ice than desired.

The water line MUST have a shut-off valve in the supply line.

The water line should be looped into 2 coils. This will allow the unit to be removed for cleaning and

servicing. Make certain that the tubing is not pinched or damaged during installation.

! CAUTION

Turn off water supply and disconnect electrical supply to unit prior to installation.

Use caution when handling back panel. The edges could be sharp.