features a variety of features, including port monitoring,
system connection and management services, Virtual
Local Area Network (VLAN) configuration, Spanning Tree
Protocol (STP), Ping Watchdog, and alerts setup.
This User Guide is designed to provide instructions about
installation of the TOUGHSwitch and to provide details
about how to set up and use the Configuration Interface.
This intuitive interface allows you to conveniently manage
your TOUGHSwitch using your web browser.
switch featuring
24V PoE
switch featuring 24V
or48VPoE
PoE PROs mounted
inarack
TOUGHSwitch PoE PRO
8-Port Power over Ethernet
Managed Switch PRO
Carrier Class
Model: TS-8-PRO
TOUGHSwitch PoE PROQuick Start GuidePower Cord
Configuration Interface System
Requirements
• Microsoft Windows XP, Windows Vista, Windows 7,
Linux, or Mac OS X
• Java Runtime Environment 1.6 (or above)
• Web Browser: Mozilla Firefox, Apple Safari, Google
Chrome, or Microsoft Internet Explorer 8 (or above)
Hardware Overview
Proceed to the description for your TOUGHSwitch model:
• TOUGHSwitch PoE Go to “TOUGHSwitch PoE” on
page 2 for the description.
• TOUGHSwitch PoE PRO Go to “TOUGHSwitch PoE
PRO” on page 3 for the description.
Package Contents
TOUGHSwitch PoE
TOUGHSwitch PoEM2.9x20 Screws
5-Port TOUGHSwitch PoE
Carrier Class
Model: TOUGHSwitch-5-POE
Quick Start GuidePower Adapter
(24V, 2.5A)
(Qty. 2)
M2.9 Anchors
(Qty. 2)
Power Cord
Ubiquiti Networks, Inc.
1
Chapter 1: OverviewTOUGHSwitch™ PoE User Guide
TOUGHSwitch PoE
Back Panel
Grounding
Slot
Front Panel Ports
Management
USBReset
InterfaceDescription
Management
USBReserved for future use.
1-5
Reset
Ventilation Holes
10/100 Mbps port for management. Traffic between
the Management port and numbered ports will
be limited to 10/100 Mbps and, under heavy
load, may cause performance degradation of the
TOUGHSwitch.
10/100/1000 Mbps ports for switching and PoE (also
available for management by default).
To reset to factory defaults, press and hold the Reset
button for more than 10 seconds while the unit is
already powered on.
1-5
Power
Grounding
Slot
Front Panel LEDs
Power/Link
LEDStateStatus
OffNo Link
Power/
Management
1-5
Speed/
Link/Act
Amber
Link
Amber Flashing
OffNo Power over Ethernet
PoE
Green24V Power over Ethernet
OffNo Link
AmberLink Established at 10/100 Mbps
Amber FlashingLink Activity at 10/100 Mbps
GreenLink Established at 1000 Mbps
Speed/Link/Act
PoE
After bootup, the LED indicates
power. After an initial link is
established, the LED indicates a
10/100 Mbps connection. If the
link terminates, the LED turns
off until a link is re-established.
If the unit reboots, the LED will
again indicate power until a link is
established.
After the Reset button is held for
more than 10 seconds, the unit is
reset to factory defaults.
Green FlashingLink Activity at 1000 Mbps
Ubiquiti Networks, Inc.
2
Chapter 1: OverviewTOUGHSwitch™ PoE User Guide
TOUGHSwitch PoE PRO
Back Panel
Ventilation Holes
Note: There are additional ventilation holes on the
top and sides of the TOUGHSwitch.
Front Panel Ports
Management
USBReset
InterfaceDescription
10/100 Mbps port for management. Traffic between
Management
USBReserved for future use.
1-8
Reset
the Management port and numbered ports will
be limited to 10/100 Mbps and, under heavy
load, may cause performance degradation of the
TOUGHSwitch.
10/100/1000 Mbps ports for switching and PoE (also
available for management by default).
To reset to factory defaults, press and hold the Reset
button for more than 10 seconds while the unit is
already powered on.
1-8
Power
Front Panel LEDs
Power/Link
LEDStateStatus
OffNo power
Power/
Management
1-8
Speed/
Link/Act
Amber
Link
Amber Flashing
OffNo Power over Ethernet
PoE
Green24V Power over Ethernet
Amber48V Power over Ethernet
OffNo link
AmberLink established at 10/100 Mbps
Amber FlashingLink activity at 10/100 Mbps
GreenLink established at 1000 Mbps
Green FlashingLink activity at 1000 Mbps
Speed/Link/Act
PoE
After bootup, the LED indicates
power. After an initial link is
established, the LED indicates a
10/100 Mbps connection. If the
link terminates, the LED turns
off until a link is re-established.
If the unit reboots, the LED will
again indicate power until a link is
established.
After the Reset button is held for
more than 10 seconds, the unit is
reset to factory defaults.
Ubiquiti Networks, Inc.
3
Chapter 2: InstallationTOUGHSwitch™ PoE User Guide
Chapter 2: Installation
Introduction
Proceed to the instructions for your TOUGHSwitch model:
• TOUGHSwitch PoE The instructions are below.
• TOUGHSwitch PoE PRO Go to “Installation of the
TOUGHSwitchPoEPRO” on page 6 for instructions.
Configuration
After you install the TOUGHSwitch, refer to the
instructions in “Navigation” on page 7, which explain
how to access the Configuration Interface.
Installation of the TOUGHSwitch PoE
Mount the TOUGHSwitch on a wall, or place it on a
benchtop.
Note: Keep 20 mm of clearance next to the
ventilation holes for adequate airflow.
Installation Requirements
• Drill, 6 mm drill bit, and Phillips screwdriver
(wall‑mounting)
• For indoor applications, use Category 5 (or above) UTP
cabling approved for indoor use.
• For outdoor applications, shielded Category 5 (or
above) cabling should be used for all wired Ethernet
connections and should be grounded through the
AC ground of the power supply. We recommend that
you protect your outdoor networks from the most
brutal environments and devastating ESD attacks with
industrial‑grade shielded Ethernet cable from Ubiquiti
Networks
www.ubnt.com/toughcable
™
. For more details, visit:
Wall-Mounting (Optional)
To mount the TOUGHSwitch on a wall:
1. Use a 6 mm drill bit to drill two holes 60 mm apart.
2. Insert the M2.9 Anchors into the holes.
3. Use a Phillips screwdriver to secure a M2.9x20 Screw to
each anchor. Leave a clearance of approximately 3 mm
between each screw head and its anchor.
60 mm
3 mm
Note: You can also mount the TOUGHSwitch in a
horizontal orientation.
4. Position the Wall-Mount Slots of the TOUGHSwitch
over the screw heads on the wall. Then slide the
TOUGHSwitch to the left to lock it into place.
Note: Although the cabling can be located
outdoors, the TOUGHSwitch itself should be
housed inside a protective enclosure.
Ubiquiti Networks, Inc.
4
Chapter 2: InstallationTOUGHSwitch™ PoE User Guide
Grounding the TOUGHSwitch (Optional)
The TOUGHSwitch is grounded through the Power
Adapter; however, you can add optional ESD grounding for
enhanced ESD protection.
1. Insert a ground wire (not included) through a corner
slot.
2. Twist tie to secure the ground wire to the
TOUGHSwitch.
3. Secure the other end of the ground wire to a
grounding block.
Connecting Power
1. Connect the power connector of the Power Adapter to
the Power port of the TOUGHSwitch.
Connecting Ethernet
1. Connect an Ethernet cable from the Ethernet port
of your computer to the Management port of the
TOUGHSwitch.
2. Connect Ethernet cables from the Ethernet ports
of your devices to the numbered ports of the
TOUGHSwitch.
2. Connect the Power Cord to the power port on the
Power Adapter. Connect the other end of the Power
Cord to a power outlet.
Ubiquiti Networks, Inc.
Note:PoE is disabled by default on all numbered
ports and is not available on the Management port.
To enable PoE on the appropriate ports, use the Ports
tab in the Configuration Interface (see “PoE” on page 20).
5
Chapter 2: InstallationTOUGHSwitch™ PoE User Guide
Installation of the
TOUGHSwitchPoEPRO
Place the TOUGHSwitch on a bench top or other flat
surface.
Note: Keep 20 mm of clearance next to the
ventilation holes for adequate airflow.
Installation Requirements
• For indoor applications, use Category 5 (or above) UTP
cabling approved for indoor use.
• For outdoor applications, shielded Category 5 (or
above) cabling should be used for all wired Ethernet
connections and should be grounded through the
AC ground of the power supply. We recommend that
you protect your outdoor networks from the most
brutal environments and devastating ESD attacks with
industrial‑grade shielded Ethernet cable from Ubiquiti
Networks™. For more details, visit:
www.ubnt.com/toughcable
Note: Although the cabling can be located
outdoors, the TOUGHSwitch itself should be
housed inside a protective enclosure.
Connecting Power
1. Connect the Power Cord to the Power port of the
TOUGHSwitch.
Connecting Ethernet
1. Connect an Ethernet cable from the Ethernet port
of your computer to the Management port of the
TOUGHSwitch.
2. Connect Ethernet cables from the Ethernet ports
of your devices to the numbered ports of the
TOUGHSwitch.
2. Connect the other end of the Power Cord to a power
outlet.
Note:PoE is disabled by default on all numbered
ports and is not available on the Management port.
To enable PoE on the appropriate ports, use the Ports
tab in the Configuration Interface (see “PoE” on page 20).
Ubiquiti Networks, Inc.
6
Chapter 3: NavigationTOUGHSwitch™ PoE User Guide
Chapter 3: Navigation
The Configuration Interface is an advanced operating
system accessed through a simple and intuitive user
interface. The TOUGHSwitch uses the Configuration
Interface for convenient configuration and management
via a web browser.
Accessing the Configuration
Interface
Connect to the Configuration Interface by performing the
following steps:
1. Ensure that your computer (or other host machine)
is connected to the Management port on the
TOUGHSwitch.
Note: By default, you can configure the
TOUGHSwitch via any port; however, we
recommend the Management port. (Access to
the Configuration Interface can be limited to the
Management port only. You can configure this
setting on the Device tab; see “Management Network Settings” on page 14.)
2. Configure the Ethernet adapter on your host system
with a static IP address on the 192.168.1.x subnet (for
example, 192.168.1.100).
3. Launch your web browser. Type https://192.168.1.20
in the address field. Press enter (PC) or return (Mac).
4. The login screen will appear. Enter ubnt in the
Username and Password fields. Click Login.
5. The Configuration Interface will appear, allowing you to
customize your settings as needed. You can enable PoE
on the Ports tab; see “PoE” on page 20.
Ubiquiti Networks, Inc.
7
Product Verification
The Configuration Interface will verify whether a product
is genuine or counterfeit.
For a genuine TOUGHSwitch, the Configuration Interface
will display a Genuine Product logo in the lower left corner
of the screen.
For any product that is not an official Ubiquiti product, the
Configuration Interface will display a counterfeit warning.
Please contact Ubiquiti at support@ubnt.com regarding
this product.
Interface Tabs
The Configuration Interface contains five main tabs, each
of which provides a web-based management page to
configure a specific aspect of the TOUGHSwitch. This User
Guide covers each tab with a chapter. For details on a
specific tab, refer to the appropriate chapter.
• Status The “Status Tab” on page 9 displays status
information and statistics for each port.
• Device The “Device Tab” on page 13 configures
system settings and services for the TOUGHSwitch.
• Ports The “Ports Tab” on page 19 configures
settings and services for each port.
• VLANs The “VLANs Tab” on page 22 configures
Virtual Local Area Networks (VLANs) for the various
ports.
• Alerts The “Alerts Tab” on page 24 displays alerts if
alert logging is configured and system log messages if
system logging is enabled.
Each page also contains network administration and
monitoring tools:
• “Ping” on page 26
• “Traceroute” on page 27
• “Discovery” on page 27
Chapter 3: NavigationTOUGHSwitch™ PoE User Guide
Ubiquiti Networks, Inc.
8
Chapter 4: Status TabTOUGHSwitch™ PoE User Guide
Chapter 4: Status Tab
The Main tab displays a summary of the link status
information, current values of the basic configuration
settings, network settings and information, and traffic
statistics.
Ubiquiti Networks, Inc.
The TOUGHSwitch image displays the active LEDs and
connections. See “Hardware Overview” on page 1
for more information.
9
Loading...
+ 26 hidden pages