Ubiquiti TouchSwitch TS-5-POE, TouchSwitch TS-8-PRO, TouchSwitch TS-16-CARRIER User Manual

Page 1
5-Port Power over Ethernet Managed Switch 8-Port Power over Ethernet Managed Switch PRO Rackmount Power over Ethernet Managed Switches
Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER
Page 2
Table of Contents
Chapter 1: Overview ................................................1
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Package Contents ................................................................1
Configuration Interface System Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Hardware Overview ..............................................................1
Chapter 2: Installation ..............................................6
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Configuration ....................................................................6
Installation of the TOUGHSwitch PoE ..............................................6
Installation of the TOUGHSwitchPoEPRO .........................................8
Installation of the TOUGHSwitchPoECARRIER .....................................9
Chapter 3: Navigation .............................................11
Accessing the Configuration Interface ...........................................11
Configuring the TOUGHSwitch PoE CARRIER .....................................12
Product Verification .............................................................12
Interface Tabs ...................................................................12
Table of ContentsTOUGHSwitch™ PoE User Guide
Chapter 4: Status Tab ..............................................13
Status ...........................................................................14
Port Status ......................................................................14
Port Statistics ....................................................................14
Total Throughput ................................................................15
Data Distribution ................................................................15
Details for Port ..................................................................15
Chapter 5: Device Tab .............................................17
Management Network Settings ..................................................18
Basic Settings ...................................................................19
Management Connection Settings ...............................................19
Services .........................................................................20
Spanning Tree Protocol ..........................................................21
Jumbo Frames. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Device Discovery ................................................................21
System Accounts ................................................................21
Maintenance ....................................................................22
Ubiquiti Networks, Inc.
i
Page 3
Chapter 6: Ports Tab ..............................................23
Basic Settings for Port ...........................................................24
Ping Watchdog for Port ..........................................................24
Spanning Tree Settings for Port ..................................................25
Configure Alerts for Port .........................................................25
Chapter 7: VLANs Tab .............................................26
VLANs ...........................................................................26
Chapter 8: Alerts Tab ..............................................28
Alert Log ........................................................................28
System Log ......................................................................29
Chapter 9: Tools ...................................................30
Ping .............................................................................30
Traceroute ......................................................................31
Discovery .......................................................................31
Table of ContentsTOUGHSwitch™ PoE User Guide
Appendix A: Specifications ........................................32
Appendix B: Safety Notices ........................................34
Electrical Safety Information .....................................................34
Appendix C: Warranty .............................................35
General Warranty ................................................................35
Appendix D: Compliance Information .............................36
FCC .............................................................................36
Industry Canada .................................................................36
Australia and New Zealand ......................................................36
Japan VCCI-A ....................................................................36
CE Marking ......................................................................36
RoHS/WEEE Compliance Statement ..............................................36
Appendix E: Declaration of Conformity ............................38
Appendix F: Contact Information ..................................39
Ubiquiti Networks Support ......................................................39
Ubiquiti Networks, Inc.
ii
Page 4
Chapter 1: OverviewTOUGHSwitch™ PoE User Guide
Chapter 1: Overview
Introduction
Thank you for purchasing the Ubiquiti TOUGHSwitch™ PoE, which is part of the TOUGHSwitch series:
Name Model Description
TOUGHSwitch PoE TS-5-POE 5-port managed
switch featuring 24V PoE
TOUGHSwitch PoE PRO TS-8-PRO 8-port managed
switch featuring 24V
or48VPoE
TOUGHSwitch PoE CARRIER TS-16-CARRIER Two TOUGHSwitch
PoE PROs mounted
inarack
The TOUGHSwitch is a managed switch designed to deliver Power over Ethernet (PoE) on the
10/100/1000portsyouhaveconfiguredforPoE.Italso
features a variety of features, including port monitoring, system connection and management services, Virtual Local Area Network (VLAN) configuration, Spanning Tree Protocol (STP), Ping Watchdog, and alerts setup.
This User Guide is designed to provide instructions about installation of the TOUGHSwitch and to provide details about how to set up and use the Configuration Interface. This intuitive interface allows you to conveniently manage your TOUGHSwitch using your web browser.
Package Contents
TOUGHSwitch PoE
TOUGHSwitch PoE PRO
8-Port Power over Ethernet Managed Switch PRO
Carrier Class
Model: TS-8-PRO
TOUGHSwitch PoE PRO Quick Start Guide Power Cord
TOUGHSwitch PoE CARRIER
Rackmount Power over Ethernet Managed Switches
Carrier Class
Model: TS-16-CARRIER
TOUGHSwitch PoE CARRIER Quick Start Guide
10-32 x 5/8 Phillips
Screws (Qty. 4)
10-32 x 5/8
Cage Nuts
(Qty. 4)
M3x8 Flathead
Screws (Qty. 2)
Power Cords
(Qty. 2)
Configuration Interface System Requirements
• Microsoft Windows XP, Windows Vista, Windows 7, Linux, or Mac OS X
• Java Runtime Environment 1.6 (or above)
• Web Browser: Mozilla Firefox, Apple Safari, Google
Chrome, or Microsoft Internet Explorer 8 (or above)
TOUGHSwitch PoE M2.9x20 Screws
5-Port TOUGHSwitch PoE
Carrier Class
Model: TOUGHSwitch-5-POE
Quick Start Guide Power Adapter
(24V, 2.5A)
(Qty. 2)
Ubiquiti Networks, Inc.
M2.9 Anchors
(Qty. 2)
Power Cord
Hardware Overview
Proceed to the description for your TOUGHSwitch model:
• “TOUGHSwitch PoE” on page 2
• “TOUGHSwitch PoE PRO” on page 3
• “TOUGHSwitch PoE CARRIER” on page 4
1
Page 5
Chapter 1: OverviewTOUGHSwitch™ PoE User Guide
TOUGHSwitch PoE
Back Panel
Grounding
Slot
Front Panel Ports
Management
USB Reset
Interface Description
Management
USB Reserved for future use.
1-5
Reset
Ventilation Holes
10/100 Mbps port for management. Traffic between the Management port and numbered ports will be limited to 10/100 Mbps and, under heavy load, may cause performance degradation of the TOUGHSwitch.
10/100/1000 Mbps ports for switching and PoE (also available for management by default).
To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the unit is already powered on.
1-5
Power
Grounding
Slot
Front Panel LEDs
Power/Link
LED State Status
Off No Link
Power/
Management
1-5
Speed/
Link/Act
Amber
Link
Amber Flashing
Off No Power over Ethernet
PoE
Green 24V Power over Ethernet
Off No Link
Amber Link Established at 10/100 Mbps
Amber Flashing Link Activity at 10/100 Mbps
Green Link Established at 1000 Mbps
Speed/Link/Act
PoE
After bootup, the LED indicates power. After an initial link is established, the LED indicates a 10/100 Mbps connection. If the link terminates, the LED turns off until a link is re-established. If the unit reboots, the LED will again indicate power until a link is established.
After the Reset button is held for more than 10 seconds, the unit is reset to factory defaults.
Green Flashing Link Activity at 1000 Mbps
Ubiquiti Networks, Inc.
2
Page 6
Chapter 1: OverviewTOUGHSwitch™ PoE User Guide
TOUGHSwitch PoE PRO
Back Panel
Ventilation Holes
Note: There are additional ventilation holes on the
top and sides of the TOUGHSwitch.
Front Panel Ports
Management
USB Reset
Interface Description
10/100 Mbps port for management. Traffic between
Management
USB Reserved for future use.
1-8
Reset
the Management port and numbered ports will be limited to 10/100 Mbps and, under heavy load, may cause performance degradation of the TOUGHSwitch.
10/100/1000 Mbps ports for switching and PoE (also available for management by default).
To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the unit is already powered on.
1-8
Power
Front Panel LEDs
Power/Link
LED State Status
Off No power
Power/
Management
1-8
Speed/
Link/Act
Amber
Link
Amber Flashing
Off No Power over Ethernet
PoE
Green 24V Power over Ethernet
Amber 48V Power over Ethernet
Off No link
Amber Link established at 10/100 Mbps
Amber Flashing Link activity at 10/100 Mbps
Green Link established at 1000 Mbps
Green Flashing Link activity at 1000 Mbps
Speed/Link/Act
PoE
After bootup, the LED indicates power. After an initial link is established, the LED indicates a 10/100 Mbps connection. If the link terminates, the LED turns off until a link is re-established. If the unit reboots, the LED will again indicate power until a link is established.
After the Reset button is held for more than 10 seconds, the unit is reset to factory defaults.
Ubiquiti Networks, Inc.
3
Page 7
Chapter 1: OverviewTOUGHSwitch™ PoE User Guide
TOUGHSwitch PoE CARRIER
A and B designate the two 8-Port TOUGHSwitch PoE PROs housed in the rack. This may be useful for the Location setting on the Device tab in the Configuration Interface.
Back Panel
TOUGHSwitch B TOUGHSwitch A
Mounting
Screws
Ventilation Holes
Power
Ventilation Holes
Power
Mounting
Screws
Note: There are additional ventilation holes on the top and sides of each TOUGHSwitch.
Front Panel Ports
TOUGHSwitch A TOUGHSwitch B
Management
Ports 1-8
ResetUSB
Management
Ports 1-8
ResetUSB
Interface Description
Management
USB Reserved for future use.
1-8 10/100/1000 Mbps ports for switching and PoE (also available for management by default).
Reset To reset to factory defaults, press and hold the Reset button for more than five seconds while the unit is already powered on.
10/100 Mbps port for management. Traffic between the Management port and numbered ports will be limited to 10/100 Mbps and, under heavy load, may cause performance degradation of the TOUGHSwitch.
Ubiquiti Networks, Inc.
4
Page 8
Front Panel LEDs
Chapter 1: OverviewTOUGHSwitch™ PoE User Guide
Power/Link/Act
LED State Status
Off No power
Power/
Link/Act
Management
Amber
Amber Flashing Link activity at 10/100 Mbps
Off No Power over Ethernet
PoE
Green 24V Power over Ethernet
Speed/Link/Act
PoE
After bootup, the LED indicates power. After an initial link is established, the LED indicates a 10/100 Mbps connection. If the link terminates, the LED turns off until a link is re-established. If the unit reboots, the LED will again indicate power until a link is established.
1-8
Speed/
Link/Act
Amber 48V Power over Ethernet
Off No link
Amber Link established at 10/100 Mbps
Amber Flashing Link activity at 10/100 Mbps
Green Link established at 1000 Mbps
Green Flashing Link activity at 1000 Mbps
Ubiquiti Networks, Inc.
5
Page 9
Chapter 2: InstallationTOUGHSwitch™ PoE User Guide
Chapter 2: Installation
Introduction
Proceed to the instructions for your TOUGHSwitch model:
• TOUGHSwitch PoE The instructions are below.
• TOUGHSwitch PoE PRO Go to “Installation of the
TOUGHSwitchPoEPRO” on page 8 for instructions.
• TOUGHSwitch PoE CARRIER Go to “Installation of
the TOUGHSwitchPoECARRIER” on page 9 for instructions.
Configuration
After you install the TOUGHSwitch, refer to the instructions in “Navigation” on page 11, which explain how to access the Configuration Interface.
Installation of the TOUGHSwitch PoE
Mount the TOUGHSwitch on a wall, or place it on a
benchtop.
Note: Keep 20 mm of clearance next to the
ventilation holes for adequate airflow.
Installation Requirements
• Drill, 6 mm drill bit, and Phillips screwdriver (wall‑mounting)
• For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use.
• For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply. We recommend that you protect your outdoor networks from the most brutal environments and devastating ESD attacks with industrial‑grade shielded Ethernet cable from Ubiquiti Networks™. For more details, visit:
www.ubnt.com/toughcable
Wall-Mounting (Optional)
To mount the TOUGHSwitch on a wall:
1. Use a 6 mm drill bit to drill two holes 60 mm apart.
2. Insert the M2.9 Anchors into the holes.
3. Use a Phillips screwdriver to secure a M2.9x20 Screw to each anchor. Leave a clearance of approximately 3 mm between each screw head and its anchor.
60 mm
3 mm
Note: You can also mount the TOUGHSwitch in a
horizontal orientation.
4. Position the Wall-Mount Slots of the TOUGHSwitch over the screw heads on the wall. Then slide the TOUGHSwitch to the left to lock it into place.
Note: Although the cabling can be located
outdoors, the TOUGHSwitch itself should be housed inside a protective enclosure.
Ubiquiti Networks, Inc.
6
Page 10
Chapter 2: InstallationTOUGHSwitch™ PoE User Guide
Grounding the TOUGHSwitch (Optional)
The TOUGHSwitch is grounded through the Power Adapter; however, you can add optional ESD grounding for
enhanced ESD protection.
1. Insert a ground wire (not included) through a corner slot.
2. Twist tie to secure the ground wire to the TOUGHSwitch.
3. Secure the other end of the ground wire to a grounding block.
Connecting Power
1. Connect the power connector of the Power Adapter to the Power port of the TOUGHSwitch.
Connecting Ethernet
1. Connect an Ethernet cable from the Ethernet port of your computer to the Management port of the TOUGHSwitch.
2. Connect Ethernet cables from the Ethernet ports of your devices to the numbered ports of the TOUGHSwitch.
2. Connect the Power Cord to the power port on the
Power Adapter. Connect the other end of the Power Cord to a power outlet.
Ubiquiti Networks, Inc.
Note: PoE is disabled by default on all numbered
ports and is not available on the Management port. To enable PoE on the appropriate ports, use the Ports tab in the Configuration Interface (see “PoE” on page 24).
7
Page 11
Chapter 2: InstallationTOUGHSwitch™ PoE User Guide
Installation of the
TOUGHSwitchPoEPRO
Place the TOUGHSwitch on a bench top or other flat surface.
Note: Keep 20 mm of clearance next to the
ventilation holes for adequate airflow.
Installation Requirements
• For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use.
• For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply. We recommend that you protect your outdoor networks from the most brutal environments and devastating ESD attacks with industrial‑grade shielded Ethernet cable from Ubiquiti Networks™. For more details, visit:
www.ubnt.com/toughcable
Note: Although the cabling can be located
outdoors, the TOUGHSwitch itself should be housed inside a protective enclosure.
Connecting Power
1. Connect the Power Cord to the Power port of the
TOUGHSwitch.
Connecting Ethernet
1. Connect an Ethernet cable from the Ethernet port of your computer to the Management port of the TOUGHSwitch.
2. Connect Ethernet cables from the Ethernet ports of your devices to the numbered ports of the TOUGHSwitch.
2. Connect the other end of the Power Cord to a power outlet.
Note: PoE is disabled by default on all numbered
ports and is not available on the Management port. To enable PoE on the appropriate ports, use the Ports tab in the Configuration Interface (see “PoE” on page 24).
Ubiquiti Networks, Inc.
8
Page 12
Chapter 2: InstallationTOUGHSwitch™ PoE User Guide
Installation of the
TOUGHSwitchPoECARRIER
Installation Requirements
• Phillips and flathead screwdrivers
• Standard‑sized, 19‑inch wide rack with a minimum
heightof1Uavailable
• For indoor applications, use Category 5 (or above) UTP
cabling approved for indoor use.
• For outdoor applications, shielded Category 5 (or
above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply. We recommend that you protect your outdoor networks from the most brutal environments and devastating ESD attacks with industrial‑grade shielded Ethernet cable from Ubiquiti Networks™. For more details, visit:
www.ubnt.com/toughcable
Note: Although the cabling can be located
outdoors, the TOUGHSwitch itself should be housed inside a protective enclosure.
Connecting the Power Cords
1. Connect the Power Cord to the Power port of each TOUGHSwitch.
Mounting in a Rack
1. Attach the TOUGHSwitch PoE CARRIER to the rack using the four 10-32 x 5/8 Phillips Screws. (If the rack has square slots, then use the 10-32 x 5/8 Cage Nuts with the Phillips Screws.)
Note: Keep 20 mm of clearance next to the
ventilation holes for adequate airflow.
2. Attach the top portion of the faceplate at a slight angle, and then snap on the bottom portion. Secure the faceplate to the TOUGHSwitch PoE CARRIER using the two M3x8 FlatheadScrews.
Ubiquiti Networks, Inc.
Connecting Power
1. Connect the other end of each Power Cord to a power outlet.
9
Page 13
Chapter 2: InstallationTOUGHSwitch™ PoE User Guide
Connecting Ethernet
1. Connect an Ethernet cable from your computer or host system to the Management port of TOUGHSwitch A.
Note: By default, you can configure the
TOUGHSwitch via any port; however, we recommend the Management port. (Access to the Configuration Interface can be limited to the Management port only. You can configure this setting on the Device tab.)
2. Connect Ethernet cables from the Ethernet ports of your devices to the numbered ports of each TOUGHSwitch.
Uplink Options
The TOUGHSwitch PoE CARRIER functions as two separate switches. All data ports are available as uplink ports, so you have the following two options:
Daisy-Chain Option
If you want to daisy‑chain TOUGHSwitch A and B, we recommend that you connect an Ethernet cable from port
8ofTOUGHSwitchAtoport1ofTOUGHSwitchB.(For
clarity, the other cables are not shown in the illustration.)
Uplink to Core Switch Option
If you want to uplink TOUGHSwitch A and B to an independent core switch, follow these instructions:
1. Connect an Ethernet cable from any numbered port of TOUGHSwitch A to a port on the core switch.
2. Connect another Ethernet cable from any numbered port of TOUGHSwitch B to a port on the core switch.
Note: PoE is disabled by default on all numbered
ports and is not available on the Management port. To enable PoE on the appropriate ports, use the Ports tab in the Configuration Interface (see “PoE” on page 24).
3. Uplink options are described in the following section. After you have finished the installation, proceed to
“Configuring the TOUGHSwitch PoE CARRIER” on page 12.
Note: For clarity, the other cables connected to the
switches are not shown, except for a cable from the EdgeRouter to the core switch.
TOUGHSwitch CARRIER
Core Switch
EdgeRouter
Ubiquiti Networks, Inc.
10
Page 14
Chapter 3: NavigationTOUGHSwitch™ PoE User Guide
Chapter 3: Navigation
The Configuration Interface is an advanced operating system accessed through a simple and intuitive user interface. The TOUGHSwitch uses the Configuration Interface for convenient configuration and management via a web browser.
If your TOUGHSwitch model is the TOUGHSwitch PoE or TOUGHSwitch PoE PRO, proceed to the next section, Accessing the Configuration Interface.
If your TOUGHSwitch model is the TOUGHSwitch PoE CARRIER, proceed to “Configuring the TOUGHSwitch
PoE CARRIER” on page 12.
Accessing the Configuration Interface
Connect to the Configuration Interface by performing the following steps:
1. Ensure that your computer (or other host machine) is connected to the Management port on the TOUGHSwitch.
Note: By default, you can configure the
TOUGHSwitch via any port; however, we recommend the Management port. (Access to the Configuration Interface can be limited to the Management port only. You can configure this setting on the Device tab; see “Management Network Settings” on page 18.)
2. Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet (for example, 192.168.1.100).
3. Launch your web browser. Type https://192.168.1.20 in the address field. Press enter (PC) or return (Mac).
4. The login screen will appear. Enter ubnt in the Username and Password fields. Click Login.
5. The Configuration Interface will appear, allowing you to customize your settings as needed. You can enable PoE on the Ports tab; see “PoE” on page 24.
Ubiquiti Networks, Inc.
11
Page 15
Chapter 3: NavigationTOUGHSwitch™ PoE User Guide
Configuring the TOUGHSwitch PoE CARRIER
ToughSwitch A and B have the same default IP address,
192.168.1.20, so you will need to change the IP address of at least one TOUGHSwitch. Follow the instructions in this section to configure one TOUGHSwitch at a time, starting
with TOUGHSwitchA.
1. Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet (e.g.,
192.168.1.100).
2. Launch your web browser. Type https://192.168.1.20 in the address field. Press enter (PC) or return (Mac).
3. The login screen will appear. Enter ubnt in the Username and Password fields. Click Login.
4. Change the Static Management IP Address to a unique IP address on the Device tab. Click Save Changes.
Product Verification
The Configuration Interface will verify whether a product is genuine or counterfeit.
For a genuine TOUGHSwitch, the Configuration Interface will display a Genuine Product logo in the lower left corner of the screen.
For any product that is not an official Ubiquiti product, the Configuration Interface will display a counterfeit warning. Please contact Ubiquiti at support@ubnt.com regarding this product.
Interface Tabs
The Configuration Interface contains five main tabs, each of which provides a web-based management page to configure a specific aspect of the TOUGHSwitch. This User Guide covers each tab with a chapter. For details on a specific tab, refer to the appropriate chapter.
Status The “Status Tab” on page 13 displays status information and statistics for each port.
Device The “Device Tab” on page 17 configures system settings and services for the TOUGHSwitch.
Ports The “Ports Tab” on page 23 configures settings and services for each port.
VLANs The “VLANs Tab” on page 26 configures Virtual Local Area Networks (VLANs) for the various ports.
Alerts The “Alerts Tab” on page 28 displays alerts if alert logging is configured and system log messages if system logging is enabled.
Each page also contains network administration and monitoring tools:
“Ping” on page 30
“Traceroute” on page 31
“Discovery” on page 31
5. You can enable PoE on the Ports tab and customize additional settings as needed.
6. Disconnect the Ethernet cable from the Management port of TOUGHSwitch A and connect it to the Management port of TOUGHSwitch B. Then repeat steps 1-5 on TOUGHSwitch B.
Ubiquiti Networks, Inc.
12
Page 16
Chapter 4: Status TabTOUGHSwitch™ PoE User Guide
Chapter 4: Status Tab
The Main tab displays a summary of the link status information, current values of the basic configuration settings, network settings and information, and traffic statistics.
Ubiquiti Networks, Inc.
The TOUGHSwitch image displays the active LEDs and connections. See “Hardware Overview” on page 1 for more information.
13
Page 17
Chapter 4: Status TabTOUGHSwitch™ PoE User Guide
Total Throughput for TX and RX are also displayed.
Place your mouse over a port to view its PoE status, Speed setting, duplex mode, and statistics for TX and RX throughput.
Status
Device Name Displays the customizable name or
identifier of the device. The Device Name (also known as host name) is displayed in registration screens and discovery tools.
Device Location Displays the description of the device’s
location.
Firmware Displays the firmware version of the
Configuration Interface.
Date Displays the current system date and time. The
date and time are displayed in YEAR-MONTH-DAY HOURS:MINUTES:SECONDS format. The system date and time is retrieved from the Internet using NTP (Network Time Protocol). The NTP Client is disabled by default on the Device tab. The device doesn’t have an internal clock, and the date and time may be inaccurate if the NTP Client is disabled or the device isn’t connected to the Internet.
Uptime This is the total time the device has been running
since the latest reboot (when the device was powered up) or software upgrade. The time is displayed in days, hours, minutes, and seconds.
Device MAC Displays the Media Access Control (MAC)
address of the device.
STP State Displays the Spanning Tree Protocol (STP)
state if STP is enabled on the Device tab. Displayed STP states include Blocking, Learning, and Forwarding. (See “Spanning Tree Protocol” on page 21 for more information.)
MTU Displays the Maximum Transmission Unit (MTU),
which is the maximum packet size (in bytes) that a network can transmit.
Alerts Displays whether alerts are set on this port.
Port Statistics
Raw/Human Readable The statistics are available in two
formats. Click the format you prefer.
• Raw Displays data in bytes. Raw format is more detailed because some bytes are not displayed in Human Readable format, which displays up to three decimal places. For example, if data is displayed in GB, bytes
arenotcounteduntiltheyreachatotalof1MB.If1GB
is displayed, the next number that will be displayed is
1.001 GB (1 GB + 1 MB = 1.001 GB).
- RX/TX Packets For the 5-Port TOUGHSwitch PoE only, you can hold your mouse over the statistic to display a popup with packet size details.
- RX/TX Errors If there are errors, you can hold your mouse over the statistic to display a popup with error details.
Port Status
Port Displays the number of the port. Name Displays the name of the port. Port Status Displays the activity status of the link
connection.
Link Status Displays the speed and duplex mode of the
port. If the port is inactive, “Down” is displayed.
PoE Displays the status and voltage of the PoE feature.
24V is displayed in green. 48V* is displayed in orange
(*available only on the TOUGHSwitch PoE PRO).
Ubiquiti Networks, Inc.
• Human Readable Displays data in megabytes (MB), kilobytes (kB), gigabytes (GB), or terabytes (TB).
Port Displays the number of the port. Name Displays the name of the port.
14
Page 18
Chapter 4: Status TabTOUGHSwitch™ PoE User Guide
RX Bytes/Data Displays the amount of data received. RX
Bytes displays the amount in Raw format (actual number
of bytes). RX Data displays the amount in Human Readable format – up to three decimal places in one of these units of measurement: megabytes (MB), kilobytes (kB), gigabytes (GB), or terabytes (TB).
RX Packets Displays the number of packets received
without errors.
RX Errors Displays the number of packets received with
errors.
TX Bytes/Data Displays the amount of data transmitted.
TX Bytes displays the amount in Raw format (actual number of bytes). TX Data displays the amount in Human Readable format – up to three decimal places in one of these units of measurement: megabytes (MB),
kilobytes(kB),gigabytes(GB),orterabytes(TB).
TX Packets Displays the number of packets transmitted
without errors.
TX Errors Displays the number of packets transmitted
with errors.
Reset Statistics Click this button to clear the displayed
statistics and reset them to zero.
All/Last 20 sec By default, the pie charts are displayed in
All format, which is cumulative over time. To display data distribution for the last 20 seconds, click Last 20 sec.
Details for Port
To display Packet Distribution, Packet Rate, and Throughput for a specific port, click the port on the image. The selected port is highlighted in blue.
To return to the default view displaying Total Throughput and Data Distribution, click Show Device Details.
Total Throughput
By default, Total Throughput and Data Distribution are displayed.
Total Throughput displays the current data traffic on the TOUGHSwitch in both graphical and numerical form. The chart scale and throughput dimension (bps, kbps, Mbps) change dynamically depending on the mean throughput value. The statistics are updated automatically.
Data Distribution
Packet Distribution
A pie chart, Packet Distribution, displays the current packet sizes going through the port. The pie chart is updated automatically.
Note: The TOUGHSwitch PoE PRO does not display
Packet Distribution.
All/Last 20 sec By default, the pie chart is displayed in All
format, which is cumulative over time. To display packet distribution for the last 20 seconds, click Last 20sec.
Two pie charts, RX and TX, display the data traffic allocated among the ports of the TOUGHSwitch. The pie charts are updated automatically.
Ubiquiti Networks, Inc.
15
Page 19
Packet Rate
Packet Rate displays the current packets per second rate on the port in both graphical and numerical form. The chart scale and packet rate dimension change dynamically depending on the mean packet rate value. The statistics are updated automatically.
Throughput
Chapter 4: Status TabTOUGHSwitch™ PoE User Guide
Throughput displays the current data traffic on the port in both graphical and numerical form. The chart scale and throughput dimension (bps, kbps, Mbps) change dynamically depending on the mean throughput value. The statistics are updated automatically.
Ubiquiti Networks, Inc.
16
Page 20
Chapter 5: Device Tab TOUGHSwitch™ PoE User Guide
Chapter 5: Device Tab
The Device tab allows you to configure and use the Management Network Settings, Basic Settings, Management Connection Settings, Services, Spanning Tree Protocol, Jumbo Frames, Device Discovery, System Account, and Maintenance options for the TOUGHSwitch.
Ubiquiti Networks, Inc.
The TOUGHSwitch image displays the active LEDs and connections. See “Hardware Overview” on page 1 for more information.
Total Throughput for TX and RX are also displayed.
17
Page 21
Chapter 5: Device Tab TOUGHSwitch™ PoE User Guide
Place your mouse over a port to view its PoE status, Speed setting, duplex mode, and statistics for TX and RX throughput.
Save Changes To immediately save your changes, click
Save Changes.
Revert Changes To cancel your changes, click Revert
Changes.
Management Network Settings
The Management Network Settings configure the IP settings and management access of the TOUGHSwitch.
Because the TOUGHSwitch is a Layer 2 device, the IP Address and Netmask are not mandatory; however, if you want to manage the TOUGHSwitch, then you will need to configure the IP Address and Netmask unless you select DHCP.
Management IP Address The TOUGHSwitch can use a
static IP address or obtain an IP address from its DHCP server.
• Static Assign static IP settings to the TOUGHSwitch.
- Gateway IP Typically, this is the IP address of the host router, which provides the point of connection to the Internet. This can be a DSL modem, cable modem, or WISP gateway router. The TOUGHSwitch directs packets to the gateway if the destination host is not within the local network. The default is 192.168.1.1.
- Primary DNS IP Specify the IP address of the primary DNS (Domain Name System) server.
- Secondary DNS IP Specify the IP address of the secondary DNS server. This entry is optional and used only if the primary DNS server is not responding.
• DHCP The local DHCP server assigns a dynamic IP address, netmask, gateway IP address, and DNS address to the TOUGHSwitch.
Note: We do not recommend the DHCP option.
The IP address may change, and you will need to use the Discovery tool from another Ubiquiti device or computer to discover the IP address of the TOUGHSwitch. You can also reset the TOUGHSwitch to its factory default settings. (Press and hold the Reset button for more than 10 seconds.) Its default IP Address is reset to
192.168.1.20.
Note: IP settings should be consistent with the
address space of the TOUGHSwitch’s network segment.
- IP Address Specify the IP address of the TOUGHSwitch. This IP will be used for device management purposes. The default is 192.168.1.20.
- Netmask When the netmask is expanded into its binary form, it provides a mapping to define which portions of the IP address range are used for the network devices and which portions are used for host devices. The netmask defines the address space of the TOUGHSwitch’s network segment. The default
255.255.255.0 (or “/24”) netmask is commonly used on many Class C IP networks.
- Management Port Only By default, this option is disabled and you can manage the TOUGHSwitch through any port. To restrict management access to only the Management port, check this box.
Note: The Management Port Only option must be
disabled if you want traffic to flow between the Management port and numbered ports. Traffic will be limited to 10/100 Mbps and, under heavy load, may cause performance degradation of the TOUGHSwitch.
- DHCP Fallback IP Specify the IP address the TOUGHSwitch should use if a DHCP server is not found. The default is 192.168.1.20.
- DHCP Fallback Netmask Specify the netmask the TOUGHSwitch should use if a DHCP server is not found. The default is 255.255.255.0.
- Management Port Only By default, this option is disabled and you can manage the TOUGHSwitch through any port. To restrict management access to only the Management port, check this box.
Note: The Management Port Only option must be
disabled if you want traffic to flow between the Management port and numbered ports. Traffic will be limited to 10/100 Mbps and, under heavy load, may cause performance degradation of the TOUGHSwitch.
Ubiquiti Networks, Inc.
18
Page 22
Chapter 5: Device Tab TOUGHSwitch™ PoE User Guide
Basic Settings
The Basic Settings configure the device, date, and location settings of the TOUGHSwitch.
Device Name Specify the Device Name (host name),
which is the system-wide device identifier. The SNMP agent reports it to authorized management stations. The Device Name will be used in popular router operating systems, registration screens, and discovery tools.
Time Zone Specify the time zone in relation to Greenwich
Mean Time (GMT). The default is (GMT) Western Europe.
Location Enter a description of the device’s location. Latitude Enter the latitude of the device’s location in
decimal format, if available. Use a minus sign (-) to indicate a latitude south of the equator.
Longitude Enter the latitude of the device’s location in
decimal format, if available. Use a minus sign (-) to indicate a longitude west of the Prime Meridian.
SSH Server
The following SSH Server parameters can be set:
SSH Server SSH access to the device is enabled by
default.
• Server Port Specify the TCP/IP port of the SSH server. The default is 22.
• Password Authentication By default, this option is
enabled and you must authenticate using administrator credentials to grant SSH access to the device. If you disable this option, then an authorized key is required.
• Authorized Keys Click Edit to import a public key file
for SSH access to the device instead of using an admin password.
Management Connection Settings
The Management Connection Settings section configures system connection services: Web Server, Telnet Server, and SSH Server.
Web Server
The following Web Server parameters can be set:
Secure Connection (HTTPS) By default, the web server
uses secure HTTPS mode.
• Secure Server Port If secure HTTPS mode is used, specify the TCP/IP port of the web server. The default is
443.
Server Port If HTTP mode is used, specify the TCP/IP port
of the web server. The default is 80.
Session Timeout Specify the maximum timeout before
the session expires. Once a session expires, you must log in again using the username and password. The default is 15 minutes.
- Choose File Click Choose File to locate the new key file. Select the file and click Open.
- Import Imports the file for SSH access.
- Enabled Enables the specific key. All the added keys are saved in the system configuration file; however, only the enabled keys are active on the device.
- Type Displays the type of key.
- Key Displays the key.
- Comment You can enter a brief description of the key.
- Action You have the following options:
• Add Adds a public key file.
• Edit Makes changes to a public key file. Click Save
to save your changes.
• Del Deletes a public key file.
- Save Saves your changes.
- Close Discards your changes.
Ubiquiti Networks, Inc.
19
Page 23
Chapter 5: Device Tab TOUGHSwitch™ PoE User Guide
Telnet Server
The following Telnet Server parameters can be set:
Telnet Server This option activates Telnet access to the
device.
• Server Port Specify the TCP/IP port of the Telnet server. The default is 23.
Services
The Services section configures system management services: SNMP Agent, System Log, Dynamic DNS, and NTP Client.
SNMP Agent
Simple Network Monitor Protocol (SNMP) is an application layer protocol that facilitates the exchange of management information between network devices. Network administrators use SNMP to monitor network-attached devices for issues that warrant attention.
The device contains an SNMP agent, which does the following:
• Provides an interface for device monitoring using SNMP
• Communicates with SNMP management applications
for network provisioning
• Allows network administrators to monitor network performance and troubleshoot network problems
Dynamic DNS
Domain Name System (DNS) translates domain names to IP addresses; Each DNS server on the Internet holds these mappings in its respective DNS database. Dynamic Domain Name System (DDNS) is a network service that notifies the DNS server in real time of any changes in the device’s IP settings. Even if the device’s IP address changes, you can still access the device through its domain name.
Dynamic DNS If enabled, the device allows
communications with the DDNS server.
• Host Name Enter the host name of the DDNS server.
• Username Enter the username of the DDNS account.
• Password Enter the password of the DDNS account.
• Show Check the box to display the password
characters.
System Log
If you enable the System Log, the messages display on the Alerts tab; see “System Log” on page 29.
For the purpose of equipment identification, configure the SNMP agent with contact and location information:
SNMP Agent Enables the SNMP agent.
• SNMP Community Specify the SNMP community string. It is required to authenticate access to Management Information Base (MIB) objects and functions as an embedded password. The device supports a read-only community string; authorized management stations have read access to all the objects in the MIB except the community strings, but do not have write access. The device supports SNMP v1. The default SNMP Community is public.
• Contact Specify the contact who should be notified in case of emergency.
• Location Specify the physical location of the device.
Ubiquiti Networks, Inc.
System Log This option enables the registration routine
of system log (syslog) messages. By default it is disabled.
• Remote Log Enables the syslog remote sending function. System log messages are sent to a remote server, which is specified in the following fields:
- Remote Log IP Address The host IP address that receives syslog messages. Properly configure the remote host to receive syslog protocol messages.
- Remote Log Port The TCP/IP port that receives syslog messages. 514 is the default port for the commonly used system message logging utilities.
Every logged message contains at least a system time and host name. Usually a specific service name that generates the system event is also specified within the message. Messages from different services have different contexts and different levels of detail. Usually error, warning, or informational system service messages are reported; however, more detailed debug level messages can also be reported. The more detailed the system messages reported, the greater the volume of log messages generated.
20
Page 24
Chapter 5: Device Tab TOUGHSwitch™ PoE User Guide
NTP Client
Network Time Protocol (NTP) is a protocol for synchronizing the clocks of computer systems over packet-switched, variable-latency data networks. You can use it to set the system time on the device. If the System Log option is enabled, then the system time is reported next to every log entry that registers a system event.
NTP Client If enabled, the device obtains the system time
from a time server on the Internet.
• NTP Server Specify the IP address or domain name of the NTP server. The default is 0.ubnt.pool.ntp.org.
Spanning Tree Protocol
For optimal performance, there should be a single active path between two networking devices in an Ethernet network. Spanning Tree Protocol (STP) provides redundant paths and prevents network loops that can create excessive traffic and slow down performance. STP calculates the best path for network traffic; if the best path fails, STP recalculates and finds the next best path.
Jumbo Frames
The Maximum Transmission Unit (MTU) is the maximum packet size (in bytes) that a network interface can transmit. A jumbo frame is a frame that is larger than the standard Ethernet frame with an MTU of 1500. Jumbo frames are typically used for Gigabit Ethernet connections.
Jumbo Frames By default, this option is disabled; the
TOUGHSwitch does not handle jumbo frames and drops them. If you enable this option, the TOUGHSwitch handles jumbo frames and forwards them. The maximum MTU of the TOUGHSwitch PoE is 9216, and the maximum MTU of the TOUGHSwitch PoE PRO is 9720.
Device Discovery
Discovery This option is enabled by default, so the device
can be discovered by other Ubiquiti devices through the Device Discovery tool. See “Discovery” on page 31 for more information.
Status Enabled by default, STP provides redundancy
without network loops.
Version Select the version of STP to use. STP and Rapid
STP (RSTP) display the following states: Blocking, Learning, and Forwarding. RSTP is recommended because ports can more quickly progress to the forwarding state. When STP is selected, the TOUGHSwitch sends STP packets. The default is RSTP.
Max Age Specify how long the TOUGHSwitch saves
a configuration message received on a port. If the TOUGHSwitch does not hear any new configuration messages after the Max Age time interval, then the TOUGHSwitch adapts and starts to reconfigure. The default is 20 seconds.
Hello Time Specify the time interval between
configuration messages transmitted by the TOUGHSwitch to other switches. The default is 2 seconds.
Forward Delay Specify how long the listening and
learning states last before the TOUGHSwitch forwards traffic. The default is 15 seconds.
Priority STP uses priority values to select a switch as the
root switch of the spanning tree. Specify the Priority value of the TOUGHSwitch. The default is 32768.
System Accounts
You can change the administrator password to protect your device from unauthorized changes. We recommend that you change the default administrator password during the very first system setup:
Administrator Username Specify the name of the
administrator.
Key button Click this button to change the password.
• Current Password Enter the current password for
the administrator account. It is required to change the Password or Administrator Username.
• New Password Enter the new password for the administrator account.
• Verify New Password Re-enter the new password for
the administrator account.
Note: The password length is 8 characters
maximum; passwords exceeding 8 characters will be truncated.
Ubiquiti Networks, Inc.
21
Page 25
Chapter 5: Device Tab TOUGHSwitch™ PoE User Guide
Maintenance
The controls in this section manage the device maintenance routines: firmware, configuration, reboot, reset to factory defaults, and support information reports.
Firmware Version Displays the current firmware version. Build Number Displays the build number of the firmware
version.
Update Firmware To update the TOUGHSwitch with new
firmware, click Update. The TOUGHSwitch firmware update is compatible with
all configuration settings. The system configuration is preserved while the TOUGHSwitch is updated with a new firmware version. However, we recommend that you click Download to back up your current system configuration before updating the firmware.
Updating the firmware is a three-step procedure:
1. Click Choose File to locate the new firmware file. Select the file and click Open.
2. Click Upload to upload the new firmware to the TOUGHSwitch.
3. The Uploaded Firmware Version is displayed. Click Update to confirm.
If the firmware update is in process, you can close the firmware update window, but this does not cancel the firmware update. Please be patient, as the firmware update routine can take three to seven minutes. You cannot access the TOUGHSwitch until the firmware update routine is completed.
Upload Configuration Click Choose File to locate the
new configuration file. Select the file and click Open. We recommend that you back up your current system configuration before uploading the new configuration.
• Upload Click this button to upload the new configuration file to the TOUGHSwitch. Click Apply to confirm.
After the TOUGHSwitch reboots, the settings of the new configuration are displayed in the Configuration Interface.
Reboot Device Initiates a full reboot cycle of the device.
Reboot is the same as the hardware reboot, which is similar to the power-off and power-on cycle. The system configuration stays the same after the reboot cycle completes. Any changes that have not been applied are lost.
Reset to Factory Defaults Resets the TOUGHSwitch to
the factory default settings. This option will reboot the TOUGHSwitch, and all factory default settings will be restored. We recommend that you back up your current system configuration before resetting the TOUGHSwitch to its defaults.
Support Info This generates a support information
file that the Ubiquiti support engineers can use when providing customer support. This file only needs to be generated at their request.
WARNING: Do not power off, do not reboot, and do
not disconnect the TOUGHSwitch from the power supply during the firmware update process as these actions will damage the TOUGHSwitch!
Back Up Configuration The TOUGHSwitch configuration
is stored in a plain text file (.cfg file). Click Download to download the current system configuration file.
Note: We strongly recommend that you save
the configuration file in a secure location. The configuration file includes confidential information, such as hashed passwords.
Ubiquiti Networks, Inc.
22
Page 26
Chapter 6: Ports Tab TOUGHSwitch™ PoE User Guide
Chapter 6: Ports Tab
The Ports tab allows you to configure the Basic Settings, Ping Watchdog settings, and alerts for each port of the
TOUGHSwitch. The TOUGHSwitch image displays the active LEDs and
connections. See “Hardware Overview” on page 1 for more information. To change a port’s settings, click the port on the image. Then the port is highlighted in blue.
Total Throughput for TX and RX are also displayed.
Place your mouse over a port to view its PoE status, Speed setting, duplex mode, and statistics for TX and RX throughput.
For each port, the Ports tab displays its Port number, Name, Status, PoE status, Link Speed, Ping Watchdog, STP status (if enabled on the Device tab), and Alerts status. To sort the ports in a specific order, click the appropriate column head.
Save Changes To immediately save your changes, click
Save Changes.
Clone Settings for All Ports After you have made
changes for the selected port, click this button to apply the same changes to all ports. Then click Save Changes.
WARNING: The PoE setting is also cloned. Ensure that
the same PoE setting suits all ports before you clone the settings of the selected port.
Ubiquiti Networks, Inc.
23
Page 27
Chapter 6: Ports Tab TOUGHSwitch™ PoE User Guide
Basic Settings for Port
Name Enter a name for the port. Port Status To use this port, check the box.
Note: If you disable a port, its PoE functionality
remains.
PoE PoE is disabled by default on all ports. To output PoE
to the connected device, select 24V or 48V (48V available only on the TOUGHSwitch PoE PRO). To disable PoE, select Off.
Note: Before enabling PoE, check the specifications
of your airMAX, UniFi, legacy, or third-party devices to ensure they support passive PoE and require the available amount of voltage. The TOUGHSwitch PoE offers 24V passive PoE, and the TOUGHSwitch PoE PRO offers 24V or 48V passive PoE.
Autonegotiation By default, Autonegotiation is
enabled. The TOUGHSwitch automatically negotiates transmission parameters, such as speed and duplex, with its counterpart. In this process, the networked devices first share their capabilities and then choose the fastest transmission mode they both support.
Note: Autonegotiation applies only to speed and
duplex, not POE.
Link Speed, Mbps This is the speed of the port. To
manually specify the maximum transmission link speed, select 100 or 10. To achieve full performance with extra-long Ethernet cables, ensure that you use CAT6-qualified cables and interconnects.
Full Duplex By default, Full Duplex is enabled. Full-duplex
mode allows communication in both directions simultaneously. Half-duplex mode allows communication in one direction at a time, alternating between transmission and reception.
Ping Watchdog for Port
Ping Watchdog is only for PoE-enabled ports. It configures the device to continuously ping a user-defined IP address (it can be the Internet gateway, for example). If it is unable to ping under the user-defined constraints, then the device will automatically turn off PoE on the port, and then turn it back on. This option creates a kind of “fail-proof” mechanism.
Ping Watchdog is dedicated to continuous monitoring of the specific connection to the remote host using the Ping tool. The Ping tool works by sending ICMP echo request packets to the target host and listening for ICMP echo response replies. If the specified number of replies is not received, the tool reboots the device.
Port Ping Watchdog Enables use of Ping Watchdog.
• IP Address To Ping Specify the IP address of the target
host to be monitored by Ping Watchdog.
• Ping Interval Specify the time interval (in seconds) between the ICMP echo requests that are sent by Ping Watchdog. The default value is 300 seconds.
• Startup Delay Specify the initial time delay (in seconds) until the first ICMP echo requests are sent by Ping Watchdog. The default value is 300 seconds.
The Startup Delay value should be at least 60 seconds as the network interface and wireless connection initialization takes a considerable amount of time if the device is rebooted.
• Failure Count Specify the number of ICMP echo
response replies. If the specified number of ICMP echo response packets is not received continuously, Ping Watchdog will reboot the device. The default value is 3.
• Cut Power for Specify the number of seconds this port
should pause PoE (if applicable).
WARNING: Cutting power during a firmware
upgrade can damage your device. Ensure that you specify a safe Ping Interval.
Ubiquiti Networks, Inc.
24
Page 28
Chapter 6: Ports Tab TOUGHSwitch™ PoE User Guide
Spanning Tree Settings for Port
STP settings are available per port if STP is enabled on the
Device tab (see “Spanning Tree Protocol” on page 21).
Edge Port If enabled, designates this port as a port that
connects to only a host device. The host device must not be connected to another switch or router. The Edge Port is always in the forwarding state and never undergoes the learning or blocking state.
Note: Ensure that the Edge Port is connected to
only a host device. If the Edge Port is connected to a switch or router (even indirectly through a host device), then this may cause a network loop.
Path Cost The lower the value, the better. STP uses the
Path Cost to determine the best path between devices. In most cases, specify lower values for ports with higher bandwidths, such as gigabit speeds, and specify higher values for ports with lower bandwidth. You can also specify lower values for ports you prefer to use. (Path Cost supersedes Priority.) The default is 0.
Priority The lower the value, the better. STP uses the
Priority as a tiebreaker. If the Path Cost of multiple ports are the same, then STP chooses the port with the highest Priority (lowest value) as the active port (the others are blocked). If STP detects a network loop, then a port with higher Priority is less likely to be blocked. If multiple ports share the highest Priority, then STP enables the port with the lowest port ID. The Priority range is 0 (highest priority) to 255 (lowest priority).The default is 128.
Configure Alerts for Port
If you configure alerts, the alerts display on the Alerts tab; see “Alert Log” on page 28.
For each port, you can configure the following alerts:
Link Goes Up/Down Generates an alert when the link
goes up or down.
RX Bandwidth Goes Above Generates an alert when the
RX bandwidth exceeds the specified maximum. Enter the maximum in Mbps.
RX Bandwidth Goes Below Generates an alert when the
RX bandwidth drops below the specified minimum. Enter the minimum in Mbps.
TX Bandwidth Goes Above Generates an alert when the
TX bandwidth exceeds the specified maximum. Enter the maximum in Mbps.
TX Bandwidth Goes Below Generates an alert when the
RX bandwidth drops below the specified minimum. Enter the minimum in Mbps.
Ubiquiti Networks, Inc.
25
Page 29
Chapter 7: VLANs Tab TOUGHSwitch™ PoE User Guide
Chapter 7: VLANs Tab
The VLANs tab configures Virtual Local Area Networks (VLANs), so you can assign ports to various VLANs for more convenient switching.
The TOUGHSwitch image displays the active LEDs and connections. See “Hardware Overview” on page 1 for more information.
Total Throughput for TX and RX are also displayed.
Place your mouse over a port to view its PoE status, Speed setting, duplex mode, and statistics for TX and RX throughput.
Save Changes To immediately save your changes, click
Save Changes.
Revert Changes To cancel your changes, click Revert
Changes.
VLANs
All ports belong to VLAN1, which is enabled as a management VLAN by default. A port can belong to more than one VLAN.
Add Create a new Virtual Local Area Network (VLAN).
• Enabled Check the box to enable the VLAN.
• Management Create the VLAN before you select this
option. Ensure that you have access via the new VLAN before you choose to manage through this VLAN.
Note: If you configure a new VLAN as Management,
then VLAN 1 is no longer the management VLAN. If you cannot access the new management VLAN, then you are locked out of the Configuration Interface. (If you are locked out, you can reset the TOUGHSwitch to its factory defaults.)
• VLAN ID Enter a unique VLAN ID from 2 to 4095.
• Comment Enter a description of this VLAN.
Ubiquiti Networks, Inc.
26
Page 30
• Port _ For each port, assign its membership status as a tagged or untagged member of this VLAN. You can also exclude a port from this VLAN.
- T (tag) The port belongs to this VLAN, and VLAN tags are included on outgoing frames. Click the letter until it becomes a “T”.
- U (untag) The port belongs to this VLAN, and VLAN tags are excluded from outgoing frames. Click the letter until it becomes a “U”.
- E (exclude) The port does not belong to this VLAN. Click the letter until it becomes a “E”.
• Delete Permanently removes the VLAN. If you want to temporarily disable the VLAN, remove the check from the Enabled box.
Chapter 7: VLANs Tab TOUGHSwitch™ PoE User Guide
Ubiquiti Networks, Inc.
27
Page 31
Chapter 8: Alerts Tab TOUGHSwitch™ PoE User Guide
Chapter 8: Alerts Tab
The Alerts tab displays logs registering alerts or system events.
The TOUGHSwitch image displays the active LEDs and connections. See “Hardware Overview” on page 1 for more information.
Total Throughput for TX and RX are also displayed.
Place your mouse over a port to view its PoE status, Speed setting, duplex mode, and statistics for TX and RX throughput.
Alert Log
When alerts logging is configured on the Ports tab (see “Configure Alerts for Port” on page 25), the Alert Log lists all alerts. By default, alert logging is disabled.
Port To display entries for all ports, select All. To display
entries for a specific port, select the port number from the drop-down list.
When alerts logging is enabled, the Select All and Clear Selected buttons are available:
Select All To select all entries in the Alert Log, click Select
All.
Clear Selected To delete specific entries in the Alert Log,
select those entries and then click Clear.
Refresh To update the log content, click Refresh. Search Allows you to search for specific text. Begin
typing; there is no need to press enter. The results are filtered in real time as soon as you type two or more characters.
Entries in the Alert Log include the Port number, Date, and Message.
Ubiquiti Networks, Inc.
28
Page 32
System Log
When system logging is enabled on the Device tab (see “System Log” on page 20), the System Log lists all system events. By default, system logging is disabled.
When system logging is enabled, there are two buttons available:
Clear To delete all entries in the System Log, click Clear. Refresh To update the log content, click Refresh.
Chapter 8: Alerts Tab TOUGHSwitch™ PoE User Guide
Ubiquiti Networks, Inc.
29
Page 33
Chapter 9: ToolsTOUGHSwitch™ PoE User Guide
Chapter 9: Tools
Each tab of the Configuration Interface contains network administration and monitoring tools. Click the Tools drop‑down list at the top right corner of the page.
Ping
You can ping other devices on the network directly from the TOUGHSwitch. The Ping tool uses ICMP packets to check the preliminary link quality and packet latency estimation between two network devices.
Network Ping
Select Destination IP You have two options:
• Select a remote system IP from the drop‑down list, which is generated automatically.
• Select or specify manually and enter the IP address in the field displayed below.
Packet Count Specify the number of packets to send for
the ping test. The default is 5.
Packet Size Specify the size of the packet in bytes. The
defaultis56.
Start Click this button to start the test.
Packet loss statistics and latency time evaluation are displayed after the test is completed.
Ubiquiti Networks, Inc.
30
Page 34
Chapter 9: ToolsTOUGHSwitch™ PoE User Guide
Traceroute
The Traceroute tool traces the hops from the TOUGHSwitch to a specified outgoing IP address. Use this tool to find the route taken by ICMP packets across the network to the destination host.
Destination Host Enter the IP address of the destination
host.
Resolve IP Addresses Select this option to resolve the IP
addresses symbolically rather than numerically.
Start Click this button to start the test.
Responses are displayed after the test is completed.
Discovery
The Device Discovery tool searches for all Ubiquiti devices on your network, specifically the subnet that the TOUGHSwitch belongs to. The Search field automatically filters devices containing specified names or numbers as you enter them.
The Device Discovery tool reports the MAC Address, Device Name, wireless Mode (if applicable), SSID, Product type, Firmware version, and IP Address for each Ubiquiti device. To access a device configuration through its web management interface, click the device’s IP address.
To refresh the window, click Scan.
Ubiquiti Networks, Inc.
31
Page 35
Appendix A: SpecificationsTOUGHSwitch™ PoE User Guide
Appendix A: Specifications
5-Port TOUGHSwitch PoE
Dimensions 197 x 87.5 x 27.3 mm Weight 250 g Power Input 24VDC, 2.5A Power Adapter (Included) Max. Power Consumption 60 W PoE Out Voltage Range 22-24VDC Max. PoE Wattage Per Data Port 11.5 W ESD Rating 24 kV Air / 24 kV Contact PoE Method Passive Button Reset USB Port 2.0 Type A (Reserved for Future Use) Processor MIPS 24K, 400 MHz System Memory 64 MB Code Storage 8 MB Certications CE, FCC, IC Wall-Mount Yes Operating Temperature -25 to 55°C (-13 to 131° F) Operating Humidity 90% Non-Condensing
PoE Congurable Per Port
Management N/A Data Ports Off/24V LEDs Per Port Management Power/Link Data Ports PoE, Speed/Link/Activity Networking Interfaces Management Port (1) 10/100 Ethernet Port Data Ports (5) 10/100/1000 Ethernet Ports
Ubiquiti Networks, Inc.
32
Page 36
Appendix A: SpecificationsTOUGHSwitch™ PoE User Guide
8-Port TOUGHSwitch PoE PRO*
Dimensions 210 x 185 x 41 mm Weight 1.24 kg Power Input 110-120VAC / 210-230VAC Max. Power Consumption 150 W PoE Out Voltage Range 45-48VDC / 22-24VDC Max. PoE Wattage Per Data Port 11.5 W (24 V), 23 W (48V) ESD Rating 24 kV Air / 24 kV Contact PoE Method Passive Button Reset USB Port 2.0 Type A (Reserved for Future Use) Processor MIPS 24K, 400 MHz System Memory 64 MB Code Storage 8 MB Certications CE, FCC, IC Operating Temperature -25 to 55°C (-13 to 131° F) Operating Humidity 90% Non-Condensing
PoE Congurable Per Port
Management N/A Data Ports Off/24V/48V LEDs Per Port Management Power/Link Data Ports PoE, Speed/Link/Activity Networking Interfaces Management Port (1) 10/100 Ethernet Port Data Ports (8) 10/100/1000 Ethernet Ports
TOUGHSwitch PoE CARRIER
Dimensions 480 x 44.5 x 186 mm Weight 3.95 kg Hardware Conguration (2) 8-Port TOUGHSwitch PoE PROs Mounting Integrated 1U Rack-Mount
* Specifications apply to each 8-Port TOUGHSwitch PoE PRO unit of the TOUGHSwitch PoE CARRIER.
Ubiquiti Networks, Inc.
33
Page 37
Appendix B: Safety Notices
1. Read, follow, and keep these instructions.
2. Heed all warnings.
3. Only use attachments/accessories specified by the manufacturer.
WARNING: Do not use this product in location that
can be submerged by water.
WARNING: Avoid using this product during an
electrical storm. There may be a remote risk of electric shock from lightning.
Electrical Safety Information
1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
a. Do not substitute the power cord with one that
is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
b. The equipment requires the use of the ground wire
as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
c. Contact a qualified electrician or the manufacturer
if there are questions about the installation prior to connecting the equipment.
d. Protective earthing is provided by Listed AC
adapter. Building installation shall provide appropriate short-circuit backup protection.
e. Protective bonding must be installed in accordance
with local national wiring rules and regulations.
Appendix B: Safety NoticesTOUGHSwitch™ PoE User Guide
Ubiquiti Networks, Inc.
34
Page 38
Appendix C: WarrantyTOUGHSwitch™ PoE User Guide
Appendix C: Warranty
General Warranty
UBIQUITI NETWORKS, Inc (“UBIQUITI NETWORKS”) represents and warrants that the Products furnished hereunder shall be free from defects in material and workmanship for a period of one (1) year from the date of shipment by UBIQUITI NETWORKS under normal use and operation. UBIQUITI NETWORKS sole and exclusive obligation under the foregoing warranty shall be to repair or replace, at its option, any defective Product that fails during the warranty period. The expense of removal and reinstallation of any item is not included in this warranty.
The foregoing warranty is exclusive and in lieu of all other warranties, express or implied, including the implied warranties of merchantability and fitness for a particular purpose and any warranties arising from a course of dealing, usage or trade practice with respect to the products. Repair or replacement in the manner provided herein shall be the sole and exclusive remedy of Buyer for breach of warranty and shall constitute fulfillment of all liabilities of UBIQUITI NETWORKS with respect to the quality and performance of the Products. UBIQUITI NETWORKS reserves the right to inspect all defective Products (which must be returned by Buyer to UBIQUITI NETWORKS factory freight prepaid).
No Products will be accepted for replacement or repair without obtaining a Return Materials Authorization (RMA) number from UBIQUITI NETWORKS. Products returned without an RMA number will not be processed and will be returned to Buyer freight collect. UBIQUITI NETWORKS shall have no obligation to make repairs or replacement necessitated by catastrophe, fault, negligence, misuse, abuse, or accident by Buyer, Buyer’s customers or any other parties. The warranty period of any repaired or replaced. Product shall not extend beyond its original term.
Disclaimer
UBIQUITI NETWORKS does not warrant that the operation of the products is error-free or that operation will be uninterrupted. In no event shall UBIQUITI NETWORKS be responsible for damages or claims of any nature or description relating to system performance, including coverage, buyer’s selection of products for buyer’s application and/or failure of products to meet government or regulatory requirements.
Returns
In the unlikely event a defect occurs, please work through the dealer or distributor from which this product was purchased.
Warranty Conditions
The foregoing warranty shall apply only if: (I) The Product has not been subjected to misuse,
neglect or unusual physical, electrical or electromagnetic stress, or some other type of accident.
(II) No modification, alteration or addition has been
made to the Product by persons other than UBIQUITI NETWORKS or UBIQUITI NETWORK’S authorized representatives or otherwise approved by UBIQUITI NETWORKS.
(III) The Product has been properly installed and used at
all times in accordance, and in all material respects, with the applicable Product documentation.
(IV) All Ethernet cabling runs use CAT5 (or above) shielded
cabling.
Ubiquiti Networks, Inc.
35
Page 39
Appendix D: Compliance InformationTOUGHSwitch™ PoE User Guide
Appendix D: Compliance Information
FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Industry Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est confrome à la norme NMB-003 Canada.
Australia and New Zealand
Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
RoHS/WEEE Compliance Statement
English
European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/ or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product.
Deutsch
Die Europäische Richtlinie 2002/96/EC verlangt, dass technische Ausrüstung, die direkt am Gerät und/oder an der Verpackung mit diesem Symbol versehen ist , nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf. Das Symbol weist darauf hin, dass das Produkt von regulärem Haushaltmüll getrennt entsorgt werden sollte. Es liegt in Ihrer Verantwortung, dieses Gerät und andere elektrische und elektronische Geräte über die dafür zuständigen und von der Regierung oder örtlichen Behörden dazu bestimmten Sammelstellen zu entsorgen. Ordnungsgemäßes Entsorgen und Recyceln trägt dazu bei, potentielle negative Folgen für Umwelt und die menschliche Gesundheit zu vermeiden. Wenn Sie weitere Informationen zur Entsorgung Ihrer Altgeräte benötigen, wenden Sie sich bitte an die örtlichen Behörden oder städtischen Entsorgungsdienste oder an den Händler, bei dem Sie das Produkt erworben haben.
Japan VCCI-A
CE Marking
CE marking on this product represents the product is in compliance with all directives that are applicable to it.
Ubiquiti Networks, Inc.
36
Page 40
Español
La Directiva 2002/96/CE de la UE exige que los equipos que lleven este símbolo en el propio aparato y/o en su embalaje no deben eliminarse junto con otros residuos urbanos no seleccionados. El símbolo indica que el producto en cuestión debe separarse de los residuos domésticos convencionales con vistas a su eliminación. Es responsabilidad suya desechar este y cualesquiera otros aparatos eléctricos y electrónicos a través de los puntos de recogida que ponen a su disposición el gobierno y las autoridades locales. Al desechar y reciclar correctamente estos aparatos estará contribuyendo a evitar posibles consecuencias negativas para el medio ambiente y la salud de las personas. Si desea obtener información más detallada sobre la eliminación segura de su aparato usado, consulte a las autoridades locales, al servicio de recogida y eliminación de residuos de su zona o pregunte en la tienda donde adquirió el producto.
Français
La directive européenne 2002/96/CE exige que l’équipement sur lequel est apposé ce symbole sur le produit et/ou son emballage ne soit pas jeté avec les autres ordures ménagères. Ce symbole indique que le produit doit être éliminé dans un circuit distinct de celui pour les déchets des ménages. Il est de votre responsabilité de jeter ce matériel ainsi que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales. L’élimination et le recyclage en bonne et due forme ont pour but de lutter contre l’impact néfaste potentiel de ce type de produits sur l’environnement et la santé publique. Pour plus d’informations sur le mode d’élimination de votre ancien équipement, veuillez prendre contact avec les pouvoirs publics locaux, le service de traitement des déchets, ou l’endroit où vous avez acheté le produit.
Appendix D: Compliance InformationTOUGHSwitch™ PoE User Guide
Italiano
La direttiva europea 2002/96/EC richiede che le apparecchiature contrassegnate con questo simbolo sul prodotto e/o sull’imballaggio non siano smaltite insieme ai rifiuti urbani non differenziati. Il simbolo indica che questo prodotto non deve essere smaltito insieme ai normali rifiuti domestici. È responsabilità del proprietario smaltire sia questi prodotti sia le altre apparecchiature elettriche ed elettroniche mediante le specifiche strutture di raccolta indicate dal governo o dagli enti pubblici locali. Il corretto smaltimento ed il riciclaggio aiuteranno a prevenire conseguenze potenzialmente negative per l’ambiente e per la salute dell’essere umano. Per ricevere informazioni più dettagliate circa lo smaltimento delle vecchie apparecchiature in Vostro possesso, Vi invitiamo a contattare gli enti pubblici di competenza, il servizio di smaltimento rifiuti o il negozio nel quale avete acquistato il prodotto.
Ubiquiti Networks, Inc.
37
Page 41
Appendix E: Declaration of ConformityTOUGHSwitch™ PoE User Guide
Appendix E: Declaration of Conformity
Česky [Czech]
Dansk [Danish]
Nederlands [Dutch]
English
Eesti [Estonian]
Suomi [Finnish]
Français [French]
Deutsch [German]
Ελληνική [Greek]
Magyar [Hungarian]
UBIQUITI NETWORKS tímto prohla uje, e tento UBIQUITI NETWORKS device, je ve shod se základními po adavky a dal ími p íslu n mi ustanoveními sm rnice 1999/5/ES.
Undertegnede UBIQUITI NETWORKS erklærer herved, at følgende udstyr UBIQUITI NETWORKS device, overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF.
Hierbij verklaart UBIQUITI NETWORKS dat het toestel UBIQUITI NETWORKS device, in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG.
Bij deze verklaart UBIQUITI NETWORKS dat deze UBIQUITI NETWORKS device, voldoet aan de essentiële eisen en aan de overige relevante bepalingen van Richtlijn 1999/5/EC.
Hereby, UBIQUITI NETWORKS, declares that this UBIQUITI NETWORKS device, is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/ EC.
Käesolevaga kinnitab UBIQUITI NETWORKS seadme UBIQUITI NETWORKS device, vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele.
UBIQUITI NETWORKS vakuuttaa täten että UBIQUITI NETWORKS device, tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.
Par la présente UBIQUITI NETWORKS déclare que l’appareil UBIQUITI NETWORKS, device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE.
Par la présente, UBIQUITI NETWORKS déclare que ce UBIQUITI NETWORKS device, est conforme aux exigences essentielles et aux autres dispositions de la directive 1999/5/CE qui lui sont applicables.
Hiermit erklärt UBIQUITI NETWORKS, dass sich diese UBIQUITI NETWORKS device, in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet”. (BMWi)
Hiermit erklärt UBIQUITI NETWORKS die Übereinstimmung des Gerätes UBIQUITI NETWORKS device, mit den grundlegenden Anforderungen und den anderen relevanten Festlegungen der Richtlinie 1999/5/EG. (Wien)
ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ UBIQUITI NETWORKS ΔΗΛΩΝΕΙ ΟΤΙ UBIQUITI NETWORKS device, ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1995/5/ΕΚ.
Alulírott, UBIQUITI NETWORKS nyilatkozom, hogy a UBIQUITI NETWORKS device, megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.
Malti [Maltese]
Norsk [Norwegian]
Slovensky [Slovak]
Svenska [Swedish]
Español [Spanish]
Polski [Polish]
Português [Portuguese]
Română [Romanian]
Hawnhekk, UBIQUITI NETWORKS, jiddikjara li dan UBIQUITI NETWORKS device, jikkonforma mal- ti ijiet essenzjali u ma provvedimenti o rajn relevanti li hemm fid-Dirrettiva 1999/5/EC.
UBIQUITI NETWORKS erklærer herved at utstyret UBIQUITI NETWORKS device, er i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF.
UBIQUITI NETWORKS t mto vyhlasuje, e UBIQUITI NETWORKS device, sp a základné po iadavky a v etky príslu né ustanovenia Smernice 1999/5/ES.
Härmed intygar UBIQUITI NETWORKS att denna UBIQUITI NETWORKS device, står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999/5/EG.
Por medio de la presente UBIQUITI NETWORKS declara que el UBIQUITI NETWORKS device, cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE.
Niniejszym, firma UBIQUITI NETWORKS o wiadcza, e produkt serii UBIQUITI NETWORKS device, spełnia zasadnicze wymagania i inne istotne postanowienia Dyrektywy 1999/5/EC.
UBIQUITI NETWORKS declara que este UBIQUITI NETWORKS device, está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE.
Prin prezenta, UBIQUITI NETWORKS declară că acest dispozitiv UBIQUITI NETWORKS este în conformitate cu cerințele esențiale și alte prevederi relevante ale Directivei 1999/5/CE.
Íslenska [Icelandic]
Italiano [Italian]
Latviski [Latvian]
Lietuviškai [Lithuanian]
Hér me l sir UBIQUITI NETWORKS yfir ví a UBIQUITI NETWORKS device, er í samræmi vi grunnkröfur og a rar kröfur, sem ger ar eru í tilskipun 1999/5/EC.
Con la presente UBIQUITI NETWORKS dichiara che questo UBIQUITI NETWORKS device, è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/ CE.
Ar o UBIQUITI NETWORKS deklar , ka UBIQUITI NETWORKS device, atbilst Direkt vas 1999/5/EK b tiskaj m pras b m un citiem ar to saist tajiem noteikumiem.
UBIQUITI NETWORKS deklaruoja, kad šis UBIQUITI NETWORKS įrenginys atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas.
Ubiquiti Networks, Inc.
38
Page 42
Appendix F: Contact Information
Ubiquiti Networks Support
Ubiquiti Support Engineers are located around the world and are dedicated to helping customers resolve software, hardware compatibility, or field issues as quickly as possible. We strive to respond to support inquiries within a 24-hour period.
Email: support@ubnt.com Phone: 408-942-1153 (9 a.m. - 5 p.m. PST)
Online Resources
Wiki Page: wiki.ubnt.com Support Forum: forum.ubnt.com Downloads: downloads.ubnt.com
Appendix F: Contact InformationTOUGHSwitch™ PoE User Guide
2580 Orchard Parkway San Jose, CA 95131
www.ubnt.com
© 2012 Ubiquiti Networks, Inc. All rights reserved. TOUGHSwitch™ and Ubiquiti Networks™ are trademarks of Ubiquiti Networks, Inc.
Ubiquiti Networks, Inc.
RRJL103012
39