Shunts
Based Mounted Shunts
828 Series
Model 828 is a compact shunt of commercial quality and is designed for chassis mounting in electronic equipment.
Specification
Model 828-92N
Installation
Shunts can be mounted horizontally or vertically. For maximum heat dissipation, mount horizontally with the element in free air and ensure that the equipment housing permits adequate ventilation.
Warning
Shunts are uninsulated and protection against accidental contact may be necessary in order to comply with Health & Safety regulations.
Accuracy class: 1.0
When calibrated together with an indicator, the overall system accuracy is within the instrument class.
Ratings: 100mA to 10A Outputs: Standard output is 75mV
50, 60, 100 or 150mV are available on request
Overload 1.2 x rated current withstand: continuously 10 x rated
current for 5 seconds at 75mV
Temperature 0.002% per °C overall. Coefficient:
Ambient Calibrated for 20°C, they temperature: can be used in an ambient
range of -20°C to +60°C
Temperature rise: When mounted as
recommended in freely circulating air, the temperature rise should not exceed 90°C at 75mV.
Dimensions
2002
Shunts
Based Mounted Shunts
829 Series
Model 829 provides an alternative to the 880 series at ratings below 100A. Its black moulded base gives the additional mechanical strength required for many applications as well as providing a means of mounting.
It is equally suitable for laboratory work or for use as a component in electronic equipment.
Specification
Model 829-92M
Construction
The manganin resistance element is silver soldered into conservatively rated brass end blocks. These are mounted on to an insulating, moulded base, drilled to provide fixing holes.
The current terminals are substantial M8 studs fitted with locknuts and washers. Connection of the potential leads is made by M5 slotted hexagon screws.
Installation
Shunts can be mounted horizontally or vertically. For maximum heat dissipation, mount horizontally with the element in free air and ensure that the equipment housing permits adequate ventilation.
Warning
Shunts are uninsulated and protection against accidental contact may be necessary in order to comply with Health & Safety regulations.
Accuracy class: 0.5
0.2 available on request When calibrated together with an indicator, the overall system accuracy is within the instrument class.
Ratings: 1 to 100 amps
Standard output is 75mV 50, 60, 100 or 150mV available on request
Overload 1.2 x rated current Withstand: continuously 10 x rated current
for 5 seconds at 75mV
Ambient Calibrated for 20°C, they can Temperature: be used in an ambient range
of -20°C to +60°C.
Temperature When mounted as rise: recommended in freely
circulating air, the temperature rise should not exceed 90°C at 75mV.
Dimensions