Rev. AD Date: February 24, 2010 Manual # 0-4975
Operating Features:
WE APPRECIATE YOUR BUSINESS!
Congratulations on your new Thermal Dynamics product. We are
proud to have you as our customer and will strive to provide you
with the best service and reliability in the industry. This product is
backed by our extensive warranty and world-wide service network.
To locate your nearest distributor or service agency call 1-800-4261888, or visit us on the web at www.thermal-dynamics.com.
This Operating Manual has been designed to instruct you on the
correct use and operation of your Thermal Dynamics product. Your
satisfaction with this product and its safe operation is our ultimate
concern. Therefore please take the time to read the entire manual,
especially the Safety Precautions. They will help you to avoid potential hazards that may exist when working with this product.
YOU ARE IN GOOD COMPANY!
The Brand of Choice for Contractors and Fabricators
Worldwide.
Thermal Dynamics is a Global Brand of manual and automation
Plasma Cutting Products for Thermadyne Industries Inc.
We distinguish ourselves from our competition through marketleading, dependable products that have stood the test of time.
We pride ourselves on technical innovation, competitive prices,
excellent delivery, superior customer service and technical support,
together with excellence in sales and marketing expertise.
Above all, we are committed to developing technologically advanced products to achieve a safer working environment within
the welding industry.
!
WARNINGS
Read and understand this entire Manual and your employer’s safety practices before installing, operating, or servicing the equipment.
While the information contained in this Manual represents the Manufacturer's best judgement, the
Manufacturer assumes no liability for its use.
Plasma Cutting Power Supply
CutMaster™ 39
SL60 1Torch™
Operating Manual Number 0-4975
Published by:
Thermal Dynamics Corporation
82 Benning Street
West Lebanon, New Hampshire, USA 03784
(603) 298-5711
www.thermal-dynamics.com
Copyright 2007, 2008, 2009 by
Thermadyne Corporation
All rights reserved.
Reproduction of this work, in whole or in part, without written permission of the
publisher is prohibited.
The publisher does not assume and hereby disclaims any liability to any party for any
loss or damage caused by any error or omission in this Manual, whether such error
results from negligence, accident, or any other cause.
Printed in the United States of America
Original Publication Date: September 4, 2007
Revision Date: February 24, 2010
Record the following information for Warranty purposes:
Where Purchased:_______________________________ ________________
APPENDIX 1: SEQUENCE OF OPERATION(BLOCK DIAGRAM) ........................................ A-1
APPENDIX 2: DATA TAG INFORMATION ............................................................................. A-2
APPENDIX 3: SYSTEM SCHEMATIC .................................................................................... A-4
GLOBAL CUSTOMER SERVICE CONTACT INFORMATION ......................... Inside Rear Cover
cutmaster 39
!
SECTION 1:
GENERAL INFORMATION
1.01 Notes, Cautions and Warnings
Throughout this manual, notes, cautions, and warnings are used to
highlight important information. These highlights are categorized as
follows:
NOTE
An operation, procedure, or background information
which requires additional emphasis or is helpful in efficient operation of the system.
CAUTION
A procedure which, if not properly followed, may cause
damage to the equipment.
WARNING
A procedure which, if not properly followed, may cause
injury to the operator or others in the operating area.
1.02 Important Safety Precautions
• The kinds of fumes and gases from the plasma arc depend on
the kind of metal being used, coatings on the metal, and the
different processes. You must be very careful when cutting
or welding any metals which may contain one or more of the
following:
• Always read the Material Safety Data Sheets (MSDS) that should
be supplied with the material you are using. These MSDSs
will give you the information regarding the kind and amount of
fumes and gases that may be dangerous to your health.
• For information on how to test for fumes and gases in your
workplace, refer to item 1 in Subsection 1.03, Publications in
this manual.
• Use special equipment, such as water or down draft cutting
tables, to capture fumes and gases.
• Do not use the plasma torch in an area where combustible or
explosive gases or materials are located.
• Phosgene, a toxic gas, is generated from the vapors of chlorinated solvents and cleansers. Remove all sources of these
vapors.
• This product, when used for welding or cutting, produces
fumes or gases which contain chemicals known to the State
of California to cause birth defects and, in some cases, cancer.
(California Health & Safety Code Sec. 25249.5 et seq.)
WARNINGS
OPERATION AND MAINTENANCE OF PLASMA ARC
EQUIPMENT CAN BE DANGEROUS AND HAZARDOUS
TO YOUR HEALTH.
Plasma arc cutting produces intense electric and
magnetic emissions that may interfere with the proper
function of cardiac pacemakers, hearing aids, or other
electronic health equipment. Persons who work near
plasma arc cutting applications should consult their
medical health professional and the manufacturer of
the health equipment to determine whether a hazard
exists.
To prevent possible injury, read, understand and follow
all warnings, safety precautions and instructions before
using the equipment. Call 1-603-298-5711 or your local
distributor if you have any questions.
GASES AND FUMES
Gases and fumes produced during the plasma cutting process can be
dangerous and hazardous to your health.
• Keep all fumes and gases from the breathing area. Keep your
head out of the welding fume plume.
• Use an air-supplied respirator if ventilation is not adequate to
remove all fumes and gases.
ELECTRIC SHOCK
Electric Shock can injure or kill. The plasma arc process uses and
produces high voltage electrical energy. This electric energy can cause
severe or fatal shock to the operator or others in the workplace.
• Never touch any parts that are electrically “live” or “hot.”
• Wear dry gloves and clothing. Insulate yourself from the work
piece or other parts of the welding circuit.
• Repair or replace all worn or damaged parts.
• Extra care must be taken when the workplace is moist or
damp.
• Install and maintain equipment according to NEC code, refer
to item 9 in Subsection 1.03, Publications.
• Disconnect power source before performing any service or
repairs.
• Read and follow all the instructions in the Operating Manual.
FIRE AND EXPLOSION
Fire and explosion can be caused by hot slag, sparks, or the plasma
arc.
• Be sure there is no combustible or flammable material in the
workplace. Any material that cannot be removed must be
protected.
• Ventilate all flammable or explosive vapors from the workplace.
Manual 0-4975 1-1 GENERAL INFORMATION
cutmaster 39
• Do not cut or weld on containers that may have held combustibles.
• Provide a fire watch when working in an area where fire hazards
may exist.
• Hydrogen gas may be formed and trapped under aluminum
workpieces when they are cut underwater or while using a water
table. DO NOT cut aluminum alloys underwater or on a water
table unless the hydrogen gas can be eliminated or dissipated.
Trapped hydrogen gas that is ignited will cause an explosion.
1.03 Publications
Refer to the following standards or their latest revisions for more
information:
1. OSHA, SAFETY AND HEALTH STANDARDS, 29CFR 1910,
obtainable from the Superintendent of Documents, U.S.
Government Printing Office, Washington, D.C. 20402
2. ANSI Standard Z49.1, SAFETY IN WELDING AND CUTTING,
obtainable from the American Welding Society, 550 N.W.
LeJeune Rd, Miami, FL 33126
NOISE
Noise can cause permanent hearing loss. Plasma arc processes can
cause noise levels to exceed safe limits. You must protect your ears
from loud noise to prevent permanent loss of hearing.
• To protect your hearing from loud noise, wear protective ear
plugs and/or ear muffs. Protect others in the workplace.
• Noise levels should be measured to be sure the decibels (sound)
do not exceed safe levels.
• For information on how to test for noise, see item 1 in Subsection 1.03, Publications, in this manual.
PLASMA ARC RAYS
Plasma Arc Rays can injure your eyes and burn your skin. The plasma
arc process produces very bright ultra violet and infra red light. These
arc rays will damage your eyes and burn your skin if you are not
properly protected.
• To protect your eyes, always wear a welding helmet or shield.
Also always wear safety glasses with side shields, goggles or
other protective eye wear.
• Wear welding gloves and suitable clothing to protect your skin
from the arc rays and sparks.
• Keep helmet and safety glasses in good condition. Replace
lenses when cracked, chipped or dirty.
• Protect others in the work area from the arc rays. Use protective
booths, screens or shields.
• Use the shade of lens as suggested in the following per ANSI/
ASC Z49.1:
Minimum Protective Suggested
Arc Current Shade No. Shade No.
Less Than 300* 8 9
300 - 400* 9 12
400 - 800* 10 14
* These values apply where the actual arc is clearly seen.
Experience has shown that lighter filters may be used
when the arc is hidden by the workpiece.
LEAD WARNING
This product contains chemicals, including lead, or otherwise produces
chemicals known to the State of California to cause cancer, birth defects
and other reproductive harm. Wash hands after handling. (California
Health & Safety Code § 25249.5 et seq.)
3. NIOSH, SAFETY AND HEALTH IN ARC WELDING AND GAS
WELDING AND CUTTING, obtainable from the Superintendent
of Documents, U.S. Government Printing Office, Washington,
D.C. 20402
4. ANSI Standard Z87.1, SAFE PRACTICES FOR OCCUPATION
AND EDUCATIONAL EYE AND FACE PROTECTION, obtainable
from American National Standards Institute, 1430 Broadway,
New York, NY 10018
5. ANSI Standard Z41.1, STANDARD FOR MEN’S SAFETY-TOE
FOOTWEAR, obtainable from the American National Standards
Institute, 1430 Broadway, New York, NY 10018
6. ANSI Standard Z49.2, FIRE PREVENTION IN THE USE OF CUT-TING AND WELDING PROCESSES, obtainable from American
National Standards Institute, 1430 Broadway, New York, NY
10018
7. AWS Standard A6.0, WELDING AND CUTTING CONTAIN-ERS WHICH HAVE HELD COMBUSTIBLES, obtainable from
American Welding Society, 550 N.W. LeJeune Rd, Miami, FL
33126
8. NFPA Standard 51, OXYGEN-FUEL GAS SYSTEMS FOR
WELDING, CUTTING AND ALLIED PROCESSES, obtainable
from the National Fire Protection Association, Batterymarch
Park, Quincy, MA 02269
9. NFPA Standard 70, NATIONAL ELECTRICAL CODE, obtainable
from the National Fire Protection Association, Batterymarch
Park, Quincy, MA 02269
10. NFPA Standard 51B, CUTTING AND WELDING PROCESSES,
obtainable from the National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269
11. CGA Pamphlet P-1, SAFE HANDLING OF COMPRESSED
GASES IN CYLINDERS, obtainable from the Compressed
Gas Association, 1235 Jefferson Davis Highway, Suite 501,
Arlington, VA 22202
12. CSA Standard W117.2, CODE FOR SAFETY IN WELDING
AND CUTTING, obtainable from the Canadian Standards Association, Standards Sales, 178 Rexdale Boulevard, Rexdale,
Ontario, Canada M9W 1R3
13. NWSA booklet, WELDING SAFETY BIBLIOGRAPHY obtainable
from the National Welding Supply Association, 1900 Arch
Street, Philadelphia, PA 19103
14. American Welding Society Standard AWSF4.1, RECOMMENDED SAFE PRACTICES FOR THE PREPARATION FOR
WELDING AND CUTTING OF CONTAINERS AND PIPING THAT
HAVE HELD HAZARDOUS SUBSTANCES, obtainable from the
American Welding Society, 550 N.W. LeJeune Rd, Miami, FL
33126
15. ANSI Standard Z88.2, PRACTICE FOR RESPIRATORY PROTECTION, obtainable from American National Standards
Institute, 1430 Broadway, New York, NY 10018
GENERAL INFORMATION 1-2 Manual 0-4975
1.04 Note, Attention et Avertissement
!
Dans ce manuel, les mots “note,” “attention,” et “avertissement” sont
utilisés pour mettre en relief des informations à caractère important.
Ces mises en relief sont classifiées comme suit :
cutmaster 39
• Les sortes de gaz et de fumée provenant de l’arc de plasma dépendent du genre de métal utilisé, des revêtements se trouvant sur le
métal et des différents procédés. Vous devez prendre soin lorsque
vous coupez ou soudez tout métal pouvant contenir un ou plusieurs
des éléments suivants:
NOTE
Toute opération, procédure ou renseignement général
sur lequel il importe d’insister davantage ou qui contribue
à l’efficacité de fonctionnement du système.
ATTENTION
Toute procédure pouvant résulter l’endommagement
du matériel en cas de non-respect de la procédure en
question.
AVERTISSEMENT
Toute procédure pouvant provoquer des blessures de
l’opérateur ou des autres personnes se trouvant dans
la zone de travail en cas de non-respect de la procédure
en question.
1.05 Precautions De Securite Importantes
AVERTISSEMENTS
L’OPÉRATION ET LA MAINTENANCE DU MATÉRIEL
DE SOUDAGE À L’ARC AU JET DE PLASMA PEUVENT
PRÉSENTER DES RISQUES ET DES DANGERS DE
SANTÉ.
Coupant à l’arc au jet de plasma produit de l’énergie
électrique haute tension et des émissions magnétique qui
peuvent interférer la fonction propre d’un “pacemaker”
cardiaque, les appareils auditif, ou autre matériel de santé
electronique. Ceux qui travail près d’une application à
l’arc au jet de plasma devrait consulter leur membre professionel de médication et le manufacturier de matériel de
santé pour déterminer s’il existe des risques de santé.
Il faut communiquer aux opérateurs et au personnel
TOUS les dangers possibles. Afin d’éviter les blessures
possibles, lisez, comprenez et suivez tous les avertissements, toutes les précautions de sécurité et toutes les
consignes avant d’utiliser le matériel. Composez le +
603-298-5711 ou votre distributeur local si vous avez
des questions.
FUMÉE et GAZ
La fumée et les gaz produits par le procédé de jet de plasma peuvent
présenter des risques et des dangers de santé.
• Lisez toujours les fiches de données sur la sécurité des matières
(sigle américain “MSDS”); celles-ci devraient être fournies avec le
matériel que vous utilisez. Les MSDS contiennent des renseignements quant à la quantité et la nature de la fumée et des gaz pouvant
poser des dangers de santé.
• Pour des informations sur la manière de tester la fumée et les gaz
de votre lieu de travail, consultez l’article 1 et les documents cités
à la page 5.
• Utilisez un équipement spécial tel que des tables de coupe à débit
d’eau ou à courant descendant pour capter la fumée et les gaz.
• N’utilisez pas le chalumeau au jet de plasma dans une zone où se
trouvent des matières ou des gaz combustibles ou explosifs.
• Le phosgène, un gaz toxique, est généré par la fumée provenant
des solvants et des produits de nettoyage chlorés. Eliminez toute
source de telle fumée.
• Ce produit, dans le procéder de soudage et de coupe, produit de
la fumée ou des gaz pouvant contenir des éléments reconnu dans
L’état de la Californie, qui peuvent causer des défauts de naissance
et le cancer. (La sécurité de santé en Californie et la code sécurité
Sec. 25249.5 et seq.)
CHOC ELECTRIQUE
Les chocs électriques peuvent blesser ou même tuer. Le procédé au jet
de plasma requiert et produit de l’énergie électrique haute tension. Cette
énergie électrique peut produire des chocs graves, voire mortels, pour
l’opérateur et les autres personnes sur le lieu de travail.
• Ne touchez jamais une pièce “sous tension” ou “vive”; portez des
gants et des vêtements secs. Isolez-vous de la pièce de travail ou
des autres parties du circuit de soudage.
• Réparez ou remplacez toute pièce usée ou endommagée.
• Prenez des soins particuliers lorsque la zone de travail est humide
ou moite.
• Montez et maintenez le matériel conformément au Code électrique
national des Etats-Unis. (Voir la page 5, article 9.)
• Débranchez l’alimentation électrique avant tout travail d’entretien
ou de réparation.
• Lisez et respectez toutes les consignes du Manuel de consignes.
• Eloignez toute fumée et gaz de votre zone de respiration. Gardez
votre tête hors de la plume de fumée provenant du chalumeau.
• Utilisez un appareil respiratoire à alimentation en air si l’aération
fournie ne permet pas d’éliminer la fumée et les gaz.
Manual 0-4975 1-3 GENERAL INFORMATION
Les incendies et les explosions peuvent résulter des scories chaudes,
des étincelles ou de l’arc de plasma. Le procédé à l’arc de plasma
INCENDIE ET EXPLOSION
cutmaster 39
produit du métal, des étincelles, des scories chaudes pouvant mettre
le feu aux matières combustibles ou provoquer l’explosion de fumées
inflammables.
• Soyez certain qu’aucune matière combustible ou inflammable ne
se trouve sur le lieu de travail. Protégez toute telle matière qu’il
est impossible de retirer de la zone de travail.
• Procurez une bonne aération de toutes les fumées inflammables
ou explosives.
• Ne coupez pas et ne soudez pas les conteneurs ayant pu renfermer
des matières combustibles.
• Prévoyez une veille d’incendie lors de tout travail dans une zone
présentant des dangers d’incendie.
• Le gas hydrogène peut se former ou s’accumuler sous les pièces
de travail en aluminium lorsqu’elles sont coupées sous l’eau ou
sur une table d’eau. NE PAS couper les alliages en aluminium sous
l’eau ou sur une table d’eau à moins que le gas hydrogène peut
s’échapper ou se dissiper. Le gas hydrogène accumulé explosera
si enflammé.
RAYONS D’ARC DE PLASMA
Les rayons provenant de l’arc de plasma peuvent blesser vos yeux et
brûler votre peau. Le procédé à l’arc de plasma produit une lumière
infra-rouge et des rayons ultra-violets très forts. Ces rayons d’arc
nuiront à vos yeux et brûleront votre peau si vous ne vous protégez
pas correctement.
BRUIT
Le bruit peut provoquer une perte permanente de l’ouïe. Les procédés
de soudage à l’arc de plasma peuvent provoquer des niveaux sonores
supérieurs aux limites normalement acceptables. Vous dú4ez vous
protéger les oreilles contre les bruits forts afin d’éviter une perte
permanente de l’ouïe.
• Pour protéger votre ouïe contre les bruits forts, portez des tampons
protecteurs et/ou des protections auriculaires. Protégez également
les autres personnes se trouvant sur le lieu de travail.
• Il faut mesurer les niveaux sonores afin d’assurer que les décibels
(le bruit) ne dépassent pas les niveaux sûrs.
• Pour des renseignements sur la manière de tester le bruit, consultez
l’article 1, page 5.
PLOMB AVERTISSEMENT
Ce produit contient des produits chimiques, comme le plomb,
ou engendre des produits chimiques, reconnus par l’état de
Californie comme pouvant être à l’origine de cancer, de malformations fœtales ou d’autres problèmes de reproduction.
Il fau t s e l a v er les main s a p rès tout e m a n ipula t i on.
(Code de Californie de la sécurité et santé, paragraphe 25249.5 et
suivants)
• Pour protéger vos yeux, portez toujours un casque ou un écran
de soudeur. Portez toujours des lunettes de sécurité munies de
parois latérales ou des lunettes de protection ou une autre sorte
de protection oculaire.
• Portez des gants de soudeur et un vêtement protecteur approprié
pour protéger votre peau contre les étincelles et les rayons de
l’arc.
• Maintenez votre casque et vos lunettes de protection en bon état.
Remplacez toute lentille sale ou comportant fissure ou rognure.
• Protégez les autres personnes se trouvant sur la zone de travail
contre les rayons de l’arc en fournissant des cabines ou des écrans
de protection.
• Utilisez la nuance de lentille qui est suggèrée dans le recommendation qui suivent ANSI/ASC Z49.1:
* Ces valeurs s’appliquent ou l’arc actuel est observé
clairement. L’experience a démontrer que les filtres
moins foncés peuvent être utilisés quand l’arc est caché
par moiceau de travail.
GENERAL INFORMATION 1-4 Manual 0-4975
1.06 Documents De Reference
Consultez les normes suivantes ou les révisions les plus récentes ayant
été faites à celles-ci pour de plus amples renseignements :
1. OSHA, NORMES DE SÉCURITÉ DU TRAVAIL ET DE PROTECTION
DE LA SANTÉ, 29CFR 1910, disponible auprès du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402
2. Norme ANSI Z49.1, LA SÉCURITÉ DES OPÉRATIONS DE COUPE
ET DE SOUDAGE, disponible auprès de la Société Américaine de
Soudage (American Welding Society), 550 N.W. LeJeune Rd.,
Miami, FL 33126
3. NIOSH, LA SÉCURITÉ ET LA SANTÉ LORS DES OPÉRATIONS DE
COUPE ET DE SOUDAGE À L’ARC ET AU GAZ, disponible auprès
du Superintendent of Documents, U.S. Government Printing Office,
Washington, D.C. 20402
4. Norme ANSI Z87.1, PRATIQUES SURES POUR LA PROTECTION
DES YEUX ET DU VISAGE AU TRAVAIL ET DANS LES ECOLES,
disponible de l’Institut Américain des Normes Nationales (American National Standards Institute), 1430 Broadway, New York, NY
10018
5. Norme ANSI Z41.1, NORMES POUR LES CHAUSSURES PROTECTRICES, disponible auprès de l’American National Standards
Institute, 1430 Broadway, New York, NY 10018
cutmaster 39
14. Norme AWSF4.1 de l’Association Américaine de Soudage, RECOMMANDATIONS DE PRATIQUES SURES POUR LA PRÉPARATION À
LA COUPE ET AU SOUDAGE DE CONTENEURS ET TUYAUX AYANT
RENFERMÉ DES PRODUITS DANGEREUX , disponible auprès de
la American Welding Society, 550 N.W. LeJeune Rd., Miami, FL
33126
15. Norme ANSI Z88.2, PRATIQUES DE PROTECTION RESPIRATOIRE,
disponible auprès de l’American National Standards Institute, 1430
Broadway, New York, NY 10018
6. Norme ANSI Z49.2, PRÉVENTION DES INCENDIES LORS DE
L’EMPLOI DE PROCÉDÉS DE COUPE ET DE SOUDAGE, disponible
auprès de l’American National Standards Institute, 1430 Broadway,
New York, NY 10018
7. Norme A6.0 de l’Association Américaine du Soudage (AWS), LE
SOUDAGE ET LA COUPE DE CONTENEURS AYANT RENFERMÉ
DES PRODUITS COMBUSTIBLES, disponible auprès de la American
Welding Society, 550 N.W. LeJeune Rd., Miami, FL 33126
8. Norme 51 de l’Association Américaine pour la Protection contre les
Incendies (NFPA), LES SYSTEMES À GAZ AVEC ALIMENTATION
EN OXYGENE POUR LE SOUDAGE, LA COUPE ET LES PROCÉDÉS
ASSOCIÉS, disponible auprès de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269
9. Norme 70 de la NFPA, CODE ELECTRIQUE NATIONAL, disponible
auprès de la National Fire Protection Association, Batterymarch
Park, Quincy, MA 02269
10. Norme 51B de la NFPA, LES PROCÉDÉS DE COUPE ET DE SOUDAGE, disponible auprès de la National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269
11. Brochure GCA P-1, LA MANIPULATION SANS RISQUE DES GAZ
COMPRIMÉS EN CYLINDRES, disponible auprès de l’Association
des Gaz Comprimés (Compressed Gas Association), 1235 Jefferson
Davis Highway, Suite 501, Arlington, VA 22202
12. Norme CSA W117.2, CODE DE SÉCURITÉ POUR LE SOUDAGE
ET LA COUPE, disponible auprès de l’Association des Normes
Canadiennes, Standards Sales, 178 Rexdale Boulevard, Rexdale,
Ontario, Canada, M9W 1R3
13. Livret NWSA, BIBLIOGRAPHIE SUR LA SÉCURITÉ DU SOUDAGE,
disponible auprès de l’Association Nationale de Fournitures de
Soudage (National Welding Supply Association), 1900 Arch Street,
Philadelphia, PA 19103
Manual 0-4975 1-5 GENERAL INFORMATION
cutmaster 39
1.07 Declaration of Conformity
Manufacturer: Thermal Dynamics Corporation
Address: 82 Benning Street
West Lebanon, New Hampshire 03784
USA
age Directive’ (European Council Directive 73/23/EEC as amended by Council Directive 93/68/EEC) and to the National legislation for the enforcement
of this Directive.
The equipment described in this manual conforms to all applicable aspects and regulations of the "EMC Directive" (European Council Directive 89/336/
EEC) and to the National legislation for the enforcement of this Directive.
Serial numbers are unique with each individual piece of equipment and details description, parts used to manufacture a unit and date of manufacture.
National Standard and Technical Specifications
The product is designed and manufactured to a number of standards and technical requirements. Among them are:
* UL (Underwriters Laboratory) rating 94VO flammability testing for all printed-circuit boards used.
* For environments with increased hazard of electrical shock, Power Supplies bearing the mark conform to EN50192 when used in
conjunction with hand torches with exposed cutting tips, if equipped with properly installed standoff guides.
* Extensive product design verification is conducted at the manufacturing facility as part of the routine design and manufacturing process.
This is to ensure the product is safe, when used according to instructions in this manual and related industry standards, and performs
as specified. Rigorous testing is incorporated into the manufacturing process to ensure the manufactured product meets or exceeds all
design specifications.
Thermal Dynamics has been manufacturing products for more than 30 years, and will continue to achieve excellence in our area of manufacture.
Manufacturers responsible representative: Steve Ward
Thermadyne Europe
Europa Building
Chorley N Industrial Park
Chorley, Lancashire,
England PR6 7BX
Operations Director
GENERAL INFORMATION 1-6 Manual 0-4975
cutmaster 39
1.08 Statement of Warranty
LIMITED WARRANTY: Subject to the terms and conditions established below, Thermal Dynamics® Corporation warrants to the original retail purchaser
that new Thermal Dynamics CUTMASTER™ plasma cutting systems sold after the effective date of this warranty are free of defects in material and
workmanship. Should any failure to conform to this warranty appear within the applicable period stated below, Thermal Dynamics Corporation shall, upon
notification thereof and substantiation that the product has been stored operated and maintained in accordance with Thermal Dynamics’ specifications,
instructions, recommendations and recognized industry practice, correct such defects by suitable repair or replacement.
This warranty is exclusive and in lieu of any warranty of merchantability or fitness for a particular purpose.
Thermal Dynamics will repair or replace, at its discretion, any warranted parts or components that fail due to defects in material or workmanship within the
time periods set out below. Thermal Dynamics Corporation must be notified within 30 days of any failure, at which time Thermal Dynamics Corporation
will provide instructions on the warranty procedures to be implemented.
Thermal Dynamics Corporation will honor warranty claims submitted within the warranty periods listed below. All warranty periods begin on the date of
sale of the product to the original retail customer or 1 year after sale to an authorized Thermal Dynamics Distributor.
LIMITED WARRANTY PERIOD
Product
Power Supply Components
(Parts and Labor)
Torch and Leads
(Parts and Labor)
CUTMASTER™ 394 Years1 Year
CUTMASTER™ 524 Years1 Year
CUTMASTER™ 824 Years1 Year
CUTMASTER™ 1024 Years1 Year
CUTMASTER™ 1524 Years1 Year
This warranty does not apply to:
1. Consumable Parts, such as tips, electrodes, shield cups, o - rings, starter cartridges, gas distributors, fuses, filters.
2. Equipment that has been modified by an unauthorized party, improperly installed, improperly operated or misused based upon industry
standards.
In the event of a claim under this warranty, the remedies shall be, at the discretion of Thermal Dynamics Corporation:
1. Repair of the defective product.
2. Replacement of the defective product.
3. Reimbursement of reasonable costs of repair when authorized in advance by Thermal Dynamics.
4. Payment of credit up to the purchase price less reasonable depreciation based on actual use.
These remedies may be authorized by Thermal Dynamics and are FOB West Lebanon, NH or an authorized Thermadyne service station. Product returned
for service is at the owner’s expense and no reimbursement of travel or transportation is authorized.
LIMITATION OF LIABILITY: Thermal Dynamics Corporation shall not under any circumstances be liable for special or consequential damages such
as, but not limited to, damage or loss of purchased or replacement goods or claims of customer of distributors (hereinafter “Purchaser”) for service
interruption. The remedies of the Purchaser set forth herein are exclusive and the liability of Thermal Dynamics with respect to any contract, or anything
done in connection therewith such as the performance or breach thereof, or from the manufacture, sale, delivery, resale, or use of the goods covered
by or furnished by Thermal Dynamics whether arising out of contract, negligence, strict tort, or under any warranty, or otherwise, shall not, except as
expressly provided herein, exceed the price of the goods upon which liability is based.
This warranty becomes invalid if replacement parts or accessories are used which may impair the safety or performance of any Thermal Dynamics
product.
This warranty is invalid if the Thermal Dynamics product is sold by non - authorized persons.
Effective September 4, 2007
Manual 0-4975 1-7 GENERAL INFORMATION
cutmaster 39
GENERAL INFORMATION 1-8 Manual 0-4975
cutmaster 39
!
SECTION 2 SYSTEM:
INTRODUCTION
2.01 How To Use This Manual
This Operating Manual applies to just
specication or part numbers listed on page i.
To ensure safe operation, read the entire manual,
including the chapter on safety instructions and
warnings.
Throughout this manual, the words WARNING, CAUTION, and NOTE may appear. Pay
particular attention to the information provided
under these headings. These special annotations
are easily recognized as
follows:
WARNING
A WARNING gives information regarding
possible personal injury.
CAUTION
A CAUTION refers to possible equipment damage.
NOTE
2.02 Equipment Identification
The unit’s identication number (specication or
part number), model, and serial number usually
appear on a data tag attached to the rear panel.
Equipment which does not have a data tag such
as torch and cable assemblies are identied
only by the specication or part number
printed on loosely attached card or the shipping
container. Record these numbers on the bottom of
page 1 for future reference.
2.03 Receipt Of Equipment
When you receive the equipment, check it against
the invoice to make sure it is complete and inspect the equipment for possible damage due to
shipping. If there is any damage, notify the carrier immediately to le a claim. Furnish complete
information concerning damage claims or shipping errors to the location in your area listed in
the inside back cover of this manual.
Include all equipment identication numbers as
described above along with a full description of
the parts in error.
Move the equipment to the installation site before
un-crating the unit. Use care to avoid damaging
the equipment when using bars, hammers, etc., to
un-crate the unit.
A NOTE offers helpful information concerning
certain operating procedures.
Additional copies of this manual may be
purchased by contacting Thermal Dynamics at
the address and phone number in your area listed
in the inside back cover of this manual. Include
the Operating Manual number and equipment
identication numbers.
Electronic copies of this manual can also be
downloaded at no charge in Acrobat PDF format
by going to the
Thermal Dynamics web site listed below and
clicking on Thermal Dynamics and then on the
Literature link:
http://www.thermal-dynamics.com
Manual 0-4975 2-1 INSTALLATION
cutmaster 39
2.04 Power Supply Specifications
CutMaster 39 Power Supply Specications
Input Power (See Note 1)120 VAC (± 10%), Single-Phase, 50/60 Hz
208 - 230 VAC (± 10%), Single-Phase, 50/60 Hz
Power SensingAutomatic Voltage Selection. See Note 1.
Cable with NEMA L6-20P plug, for use with one of two adapters provided,
Input Power Cable
Output Current20-30 Amps, continuously variable
Power Supply Gas Filtering Ability Particulates to 20 Microns
CutMaster 39 Power Supply Duty Cycle (Note 2)
Ambient Temperature104° F (40° C)
Duty Cycle35%60%
DC Voltage78 vdc89 vdc
Current30 Amps22 Amps
Gas TypeCompressed Air
Gas specicationsClean, dry, oil-free (Note 3)
Maximum Input Gas Pressure125 psi / 8.6 bar
Operating Gas Pressure65 psi / 4.5 bar
Gas Flow Requirements300 scfh / 141.5 lpm
120V/15A with NEMA 5-15P plug or 240V/20A with NEMA 6-50P plug
SL 60 Torch Gas Requirements
Notes
1. Power supply accepts 120-230 VAC input power. No manual switching is required.
2. Duty Cycle is the percentage of time the system can be operated without overheating. Duty cycle is
reduced if primary input voltage (AC) is low or the DC voltage is higher than shown in this chart.
3. Air supply must be free of oil, moisture, and other contaminants. Excessive oil and moisture may
cause double-arcing, rapid tip wear, or even complete torch failure. Contaminants may cause poor cutting
performance and rapid electrode wear. Optional lters provide increased ltering capabilities.
NOTE
IEC Rating is determined as specified by the International Electro-Technical Commission. These specifications
include calculating an output voltage based upon power supply rated current. To facilitate comparison between
power supplies, all manufacturers use this output voltage to determine duty cycle.
TDC Rating is determined using an output voltage representative of actual output voltage during cutting with
a TDC torch. This voltage may be more or less than IEC voltage, depending upon choice of torch, consumables,
and actual cutting operation.
INSTALLATION 2-2 Manual 0-4975
cutmaster 39
15"
381 mm
12"
305 mm
24"
610 mm
45 lb / 20.4 kg
Art # A-07924_AB
6"
150 mm
24"
610 mm
6"
150 mm
6"
150 mm
Art # A-07925_AB
Power Supply Dimensions & Weight Ventilation Clearance Requirements
NOTE
Weight includes torch & leads, input power cord, and work cable with clamp.
CAUTION
Provide clearance for proper air flow through the power supply. Operation without proper air flow will inhibit
proper cooling and reduce duty cycle.
2.05 Input Wiring Specifications
CutMaster 39 Input Power Requirements
Input
VoltageFreq.(kVA)
(Volts)(Hz)1-Ph1-Ph1-Ph1-Ph1-Ph
12050 / 60
20850 / 60
23050 / 60
Power Input Current InputSuggested Sizes (See Notes)
(Amps)Fuse (Amps) Wire (AWG) Wire (Canada)
3.629351212
3.516201212
3.414201212
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTES
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations.
Cable conductor temperature used is 167° F (75° C).
An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should
be used to minimize damage to Plasma Cutting, Welding or power distribution equipment.
NEVER use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.
Extension Cords
Extension cords must meet National Electric Code Guidelines (and OSHA Guidelines, where applicable). Extension cords must have the same rating as the service and must have a three-pronged plug.
Manual 0-4975 2-3 INSTALLATION
cutmaster 39
10.125" (257 mm)
3.75"
(95 mm)
1.17" (29 mm)
Art # A-03322_AB
2.06 Power Supply Options and Accessories
The following options and accessories are available for this Power Supply. Section 6 provides catalog
numbers and ordering information.
A. Single-Stage Air Filter Kit
A single-stage air filter for use on compressed air shop systems. Highly effective at removing moisture and
particulate matter from the air stream to at least 0.85 microns.
B. Multi-Purpose Cart
Rugged steel cart on easy-rolling rear wheels and front-mounted swivel casters. Provides maximum mobility for the power supply and can also serve as a display cart. Top shelf is 12 " (305 mm) x 20 (508 mm). Steel
handle is 30" (762 mm) high.
C. Cutting Guide Kit
Easy add-on attachments for straight line, circle, or bevel cutting.
2.07 Torch Specifications
A. Torch Configuration and Dimensions
The torch head is at 75° to the torch handle. The torch includes a torch handle and torch trigger assembly.
Torch Configuration and Dimensions
B. Torch Leads Lengths
Leads are available in 20 ft (6.1 m) lengths.
C. Parts-In-Place (PIP)
Torch has built-in switch.
12 vdc circuit rating
D. Type of Cooling
Combination of ambient air and gas stream through torch
E. SL60 Torch Ratings (Refer to Note)
NOTE
Ratings shown apply to the SL60 Torch only. Refer to the Specifications chart on page 2T-1 for CutMaster 39
data.
F. Plasma Power Supply Used With
• Thermal Dynamics CutMaster 39
INSTALLATION 2-4 Manual 0-4975
cutmaster 39
10.125" (257 mm)
3.75"
(95 mm)
1.17" (29 mm)
Art # A-03322_AB
SECTION 2 TORCH:
INTRODUCTION
2T.01 Scope of Manual
This manual contains descriptions, operating
instructions and maintenance procedures for
the 1Torch Model SL60 Plasma Cutting Torch.
Service of this equipment is restricted to properly trained personnel; unqualied personnel are
strictly cautioned against attempting repairs or
adjustments not covered in this manual, at the risk
of voiding the Warranty.
Read this manual thoroughly. A complete understanding of the characteristics and capabilities of
this equipment will assure the dependable operation for which it was designed.
2T.02 General Description
Plasma torches are similar in design to the automotive spark plug. They consist of negative and
positive sections separated by a center insulator.
Inside the torch, the pilot arc starts in the gap
between the negatively charged electrode and
the positively charged tip. Once the pilot arc has
ionized the plasma gas, the superheated column of
gas ows through the small orice in the torch tip,
which is focused on the metal to be cut.
A single torch lead provides gas from a single
source to be used as both the plasma and secondary gas. The air ow is divided inside the torch
head. Single - gas operation provides a smaller
sized torch and inexpensive operation.
NOTE
Refer to Section 2T.05, Introduction To Plasma,
for a more detailed description of plasma torch
operation.
Refer to the Appendix Pages for additional specifications as related to the Power Supply used.
2T.03 Specifications
A. Torch Configurations
1. Hand Torch, Model SL60
The hand torch head is at 75° to the torch handle.
The hand torches include a torch handle and torch
trigger assembly.
B. Torch Leads Lengths
Hand Torches are available as follows:
• 20 ft / 6.1 m.
C. Torch Parts
Starter Cartridge, Electrode, Tip, Shield Cup
D. Parts - In - Place (PIP)
Torch Head has built - in switch
12 vdc circuit rating
E. Type Cooling
Combination of ambient air and gas stream through
torch.
F. Torch Ratings
SL60 Torch Ratings
Ambient
Temperature
Duty Cycle
Maximum Current
Voltage (V
Arc Striking Voltage
G. Current Ratings
peak
)
100% @ 60 Amps @ 400 scfh
104° F
40° C
60 Amps
500V
7kV
SL60 Current Ratings
SL60 Torch & Leads
Power Supply characteristics will determine material thickness range.
Manual 0-4975 2T-1 INTRODUCTION
Up to 60 Amps, DC,
Straight Polarity
NOTE
cutmaster 39
!
A-00002
Workpiece
Power
Supply
+
_
C
B
A
H. Gas Requirements
SL60 Torch Gas Specications
Gas (Plasma and Secondary)Compressed Air
Operating Pressure
Refer to NOTE
Maximum Input Pressure125 psi / 8.6 bar
Gas Flow (Cutting and Gouging)
WARNING
This torch is not to be used with oxygen (O2).
NOTE
Operating pressure varies with torch model, operating amperage, and torch leads length. Refer to
gas pressure settings charts for each model.
I. Direct Contact Hazard
For exposed tip the recommended standoff is 3/16
inches / 4.7 mm.
60 - 75 psi
4.1 - 5.2 bar
300 - 500 scfh
142 - 235 lpm
2T.05 Introduction to Plasma
A. Plasma Gas Flow
Plasma is a gas which has been heated to an extremely high temperature and ionized so that it
becomes electrically conductive. The plasma arc
cutting and gouging processes use this plasma to
transfer an electrical arc to the workpiece. The metal
to be cut or removed is melted by the heat of the arc
and then blown away.
While the goal of plasma arc cutting is separation of
the material, plasma arc gouging is used to remove
metals to a controlled depth and width.
In a Plasma Cutting Torch a cool gas enters Zone B,
where a pilot arc between the electrode and the torch
tip heats and ionizes the gas. The main cutting arc
then transfers to the workpiece through the column
of plasma gas in Zone C.
2T.04 Options And Accessories
These items can adapt a standard system to a
particular application or further enhance performance.
• Deluxe Cutting Guide Kit - Easy add - on
attachments for precise straight line, circle
cutting, and beveling. Includes carrying
case.
• Trigger Guard Kits - These offer additional
protection from accidental activation of the
torch switch.
• Leads Extensions for torches with ATC con-
nectors
• Leather Leads Covers
Typical Torch Head Detail
By forcing the plasma gas and electric arc through a
small orifice, the torch delivers a high concentration
of heat to a small area. The stiff, constricted plasma
arc is shown in Zone C. Direct current (DC) straight
polarity is used for plasma cutting, as shown in the
illustration.
Zone A channels a secondary gas that cools the torch.
This gas also assists the high velocity plasma gas in
blowing the molten metal out of the cut allowing for
a fast, slag - free cut.
INTRODUCTION 2T-2 Manual 0-4975
B. Gas Distribution
A-02997
Torch Trigger
PIP Switch
Shield Cup
To Control
Cable Wiring
Torch Switch
The single gas used is internally split into plasma
and secondary gases.
The plasma gas flows into the torch through the
negative lead, through the starter cartridge, around
the electrode, and out through the tip orifice.
The secondary gas flows down around the outside
of the torch starter cartridge, and out between the
tip and shield cup around the plasma arc.
C. Pilot Arc
When the torch is started a pilot arc is established
between the electrode and cutting tip. This pilot
arc creates a path for the main arc to transfer to the
work.
D. Main Cutting Arc
DC power is also used for the main cutting arc. The
negative output is connected to the torch electrode
through the torch lead. The positive output is connected to the workpiece via the work cable and to
the torch through a pilot wire.
cutmaster 39
E. Parts - In - Place (PIP)
The torch includes a 'Parts - In - Place' (PIP) circuit.
When the shield cup is properly installed, it closes
a switch. The torch will not operate if this switch
is open.
Parts - In - Place Circuit Diagram for Hand Torch
Manual 0-4975 2T-3 INTRODUCTION
Loading...
+ 47 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.