T100e thermostatic care & care plus
PLEASE READ THIS IMPORTANT SAFETY INFORMATION
Products manufactured by Triton are safe and without risk provided they are installed, used and
maintained in good working order in accordance with our instructions and recommendations.
WARNING:DO NOT operate shower if frozen, or suspected of being frozen. It must thaw out
before using.
DO NOT operate the unit if the showerhead or spray hose becomes damaged.
DO NOT restrict flow out of shower by placing showerhead in direct contact with your body.
DO NOT operate the shower if water ceases to flow during use or if water has entered inside
the unit because of an incorrectly fitted cover.
1 GENERAL
1.1 Isolate the electrical and water supplies before
removing the cover.
1.2 Read all of these instructions and retain them
for later use.
1.3 DO NOT take risks with plumbing or electrical
equipment.
1.4 Isolate electrical and water supplies before
proceeding with the installation.
1.5 The unit must be mounted onto the finished
wall surface (on top of the tiles). DO NOT tile
up to or seal around ANY PART of the unit
using silicone sealer after fixing to the wall.
Special care must be taken NOT TO BLOCK OR SEAL ANY PRD VENTS ON THE UNIT.
1.6 Contact Customer Service (see back page), if
any of the following occur:
a) If it is intended to operate the shower at
pressures above the maximum or below the
minimum stated.
b) If the unit shows a distinct change in
performance.
c) If the shower is frozen.
1.7 If it is intended to operate the shower in areas
of hard water (above 200 ppm temporary
hardness), a scale inhibitor may have to be
fitted. For advice on the Scale Inhibitor,
contact Customer Service.
1.8 The showerhead must be cleaned regularly
with descalent to remove scale and debris,
otherwise restrictions to the flow on the outlet
of the unit will result in higher temperatures
and could also cause the (PRD) Pressure Relief
Device in the unit to operate.
1.9 This product is not suitable for mounting into
steam rooms or steam cubicles.
2 PLUMBING
2.1 The plumbing installation must comply with
Water Regulations, Building Regulations or any
particular regulations as specified by Local
Water Company or Water Undertakers and
should be in accordance with BS 6700.
2.2 The supply pipe must be flushed to clear debris
before connecting to the shower unit.
2.3 DO NOT solder pipes or fittings within 300mm
of the shower unit, as heat can transfer along
the pipework and damage components.
2.4 DO NOT fit any form of outlet flow control as
the outlet acts as a vent for the heater can.
2.5 DO NOT use excessive force when making
connections to the flexible hose or
showerhead, finger tight is sufficient.
2.6 All plumbing connections must be completed
before making the electrical connections.
3 ELECTRICAL
3.1 The installation must comply with BS 7671
‘Requirements for electrical installations’ (IEE
wiring regulations), building regulations or any
particular regulations as specified by the local
Electrical Supply Company.
3.2 This appliance MUST be earthed.
3.3 In accordance with ‘The Plugs and Sockets etc.
(Safety) Regulations 1994’, this appliance is
intended to be permanently connected to the
fixed wiring of the electrical mains system.
3.4 Make sure all electrical connections are tight to
prevent overheating.
3.5 A 30mA residual current device (RCD) MUST
be installed in all UK electric and pumped
shower circuits. This may be part of the
consumer unit or a separate unit.
3.6 Switch off immediately at isolating switch if
water ceases to flow during use.
3.7 Other electrical equipment i.e. extractor fans,
pumps must not be connected to the circuits
within the unit.
3.8 Switch off at isolating switch when not in use.
This is a safety procedure recommended with
all electrical appliances.
3.9 As with all electrical appliances it is
recommended to have the shower and
installation checked at least every two years by
a competent electrician to ensure there is no
deterioration due to age and usage.
1
Page 4
T100e thermostatic care & care plus
SPECIFICATIONS
INTRODUCTION
UNDERSTANDING YOUR SHOWER
Introduction
This book contains all the necessary installation
and operating instructions for your Triton T100e
Thermostatic Care or Care Plus electric shower.
Take time to read this book thoroughly and
familiarise yourself with all instructions BEFORE
starting installation. Please keep it for future
reference.
The shower installation must be carried out by a
suitably qualified person and in the sequence of
this instruction book.
Care taken during the installation will provide a
long, trouble-free life from your shower.
Specifications
Electrical
Nominal power Nominal power
rating at 240V rating at 230V
8.5kW – (40A MCB rating) 7.8kW – (40A MCB rating)
Water
Inlet connection – 15 mm diameter.
Outlet connection – ½” BSP male thread.
Entry Points
Water – Right: back, bottom, top.
Cable – Right: back, bottom, top.
Materials
Backplate, cover, controls, showerhead – ABS.
Sprayplate – Acetal.
Elements – Minerally insulated corrosion resistant
metal sheathing.
Complies with the requirements of current British
and European safety standards for household
and similar electrical appliances.
Complies with requirements of the British
Electrotechnical Approvals Board (BEAB).
Meets with Compliance with European
Community Directives (CE).
Understanding your shower
IMPORTANT: When first installed the unit
will be empty. It is essential the unit should
contain water before the elements are
switched on. It is vital that the
commissioning procedure is followed.
Failure to carry out this operation will result
in damage to the unit and will invalidate the
guarantee.
I-001-A
Temperature/flow rate
The temperature control on the unit can be
adjusted to provide shower temperatures to
meet individual needs.
Note: The maximum flow rate for the given
temperature will be greater in the summer
than in winter because of ambient temperature
variance of the mains water supply.
It is strongly advised to select economy power
during periods of hot weather, otherwise at all
other times, leave the power setting at full to
provide the maximum flow rate.
Safety cut-out
The unit is fitted with a non-resettable overtemperature safety device. In the event of
abnormal operation which could cause unsafe
temperatures within the unit, the device will
disconnect the heating elements. It will require a
visit from a qualified engineer to determine the
nature of the fault and replace the safety device,
once the unit has been repaired.
Replacement parts can be ordered from Customer
Service. See ‘spare parts’ for details and part numbers.
Y-003-A
2
Page 5
T100e thermostatic care & care plus
MAIN COMPONENTS
L
L
N
N
17
1
2
17
3
3
3
4
5
6
10
12
8
7
9
11
14
13
15
16
17
20
20
20
19
21
18
Main components
Inside unit (fig.1)
1. Top cable / pipe entry
2. Bottom cable / pipe entry
3. Wall screw fixings
4. Power Printed Circuit Board
5. Thermal cut-out
6. Can and element assembly
7. Ribbon cable connector
8. Terminal block
9. Earth connection
10. PRD
11. Solenoid valve
12. Trim plate
13. Thermostatic valve
14. Scale trap
15. Pressure switch
16. Shower outlet
17. Guide pockets
Inside cover (fig.2)
18. Control Printed Circuit Board
19. Start/stop Printed Circuit Board
20. Cover tags
21. Ribbon cable
Fig.1
1717
3
4
1
3
5
9
6
7
8
10
11
12
13
16
3
15
2
14
17
Note: Not all wires have been depicted for reason of clarity.
Fig.2
3
2020
18
21
20
19
Page 6
T100e thermostatic care & care plus
Meter
Incoming
supply
fuse
Meter
tails
Consumer
unit
Pull cord
isolating switch
Shower
unit
Fuse or
MCB
RCD
(can be part of
consumer unit)
80A or 100A
main switch
Shepperton Park,
Triton Road, Nuneaton,
Warwickshire, CV11 4NR
MCB
30/32A
32A
40A
40A
40A
40/45A
45A
cartridge
fuse
30A
35A
35A
45A
45A
45A
45A
unit
rating
7.0kW
7.5kW
8.0kW
8.5kW
9.0kW
9.5kW
10.5kW
CIRCUIT PROTECTION
W-006-A
WARNING!
THIS APPLIANCE MUST BE EARTHED
ELECTRICAL REQUIREMENTS
The installation, supply cable and circuit
protection must conform with BS 7671 (IEE
wiring regulations) and be sufficient for the
amperage required.
The following notes are for guidance only:
1 The shower must only be connected to a
230-240V ac supply. If you are installing a
shower with a kilowatt rating above 9kW, it
is advisable to contact the local electricity
supply company.
1.1 The electrical rating of the shower is shown
on the rating label (Fig.3) within the unit.
2 Before making any sort of electrical
connection within the installation make sure
that no terminal is live. If in any doubt,
switch off the whole installation at the mains
supply and remove the correct fuse.
3 The shower must be connected to its own
independent electrical circuit. IT MUST NOT
be connected to a ring main, spur, socket
outlet, lighting circuit or cooker circuit.
3.1 The electrical supply must be adequate for
the loading of the unit and existing circuits.
4 Check your consumer unit (main fuse box)
has a main switch rating of 80A or above
and that it has a spare fuse way which will
take the fuse or Miniature Circuit Breaker
(MCB) necessary for the shower (Fig.4).
4.1 If your consumer unit has a rating below
80A or if there is no spare fuse way, then the
installation will not be straightforward and
may require a new consumer unit serving
the house or just the shower.
4.2 You will need to contact the local electricity
company. They will check the supply and
carry out what is necessary.
5 For close circuit protection DO NOT use a
rewireable fuse. Instead use a suitably rated
Miniature Circuit Breaker (MCB) or cartridge
fuse (see Table A).
Fig.3
Fig.4 Schematic of installation circuit
Table A
4
Page 7
Note: Cable selection is dependent on
derating factors
Twin and earth PVC insulated cable
Current carrying capacity
In conduit
trunking
6 mm²
38A
10 mm²
52A
16 mm²
69A
Installed in an
insulated wall
6 mm²
35A
10 mm²
47A
16 mm²
63A
Clipped direct
or buried in a
non-insulated
wall
6 mm²
47A
10 mm²
64A
16 mm²
85A
installation will not be straightforward and may require a new consumer unit serving the house or just the shower.
4.2You will need to contact the local electricity
company. They will check the supply and carry out what is necessary.
5For close circuit protection DO NOT use a
rewireable fuse. Instead use a suitably rated Miniature Circuit Breaker (MCB) or cartridge fuse (see Table A).
E-002-A
5.1A 30mA residual current device (RCD) must
be installed in all UK electric and pumped shower circuits. This may be part of the consumer unit or a separate unit.
6A 45 amp double pole isolating switch with
a minimum contact gap of 3 mm in both poles must be incorporated in the circuit.
6.1It must have a mechanical indicator showing
when the switch is in the OFF position, and the wiring must be connected to the switch without the use of a plug or socket outlet.
6.2The switch must be accessible and clearly
identifiable, but out of reach of a person using a fixed bath or shower, except for the cord of a cord operated switch, and should be placed so that it is not possible to touch the switch body while standing in a bath or shower cubicle. It should be readily accessible to switch off after using the shower.
7Where shower cubicles are located in any
rooms other than bathrooms, all socket outlets in those rooms must be protected by a 30mA RCD.
8The current carrying capacity of the cable
must be at least that of the shower circuit protection (see Table B).
8.1To obtain full advantage of the power
provided by the shower, use the shortest cable route possible from the consumer unit to the shower.
8.2It is also necessary to satisfy the
disconnection time and thermal constraints which means that for any given combination of current demand, voltage drop and cable size, there is a maximum permissible circuit length.
9The shower circuit should be separated from
other circuits by at least twice the diameter of the cable or conduit.
9.1The current rating will be reduced if the
cabling is bunched with others, surrounded by thermal loft or wall insulation or placed in areas where the ambient temperature is above 30°C. Under these conditions, derating factors apply and it is necessary to select a larger cable size.
9.2In the majority of installations, the cable
5.1 A 30mA residual current device (RCD) must
be installed in all UK electric and pumped
shower circuits. This may be part of the
consumer unit or a separate unit.
6 A 45 amp double pole isolating switch with
a minimum contact gap of 3 mm in both
poles must be incorporated in the circuit.
6.1 It must have a mechanical indicator showing
when the switch is in the OFF position, and
the wiring must be connected to the switch
without the use of a plug or socket outlet.
6.2 The switch must be accessible and clearly
7 Where shower cubicles are located in any
8 The current carrying capacity of the cable
8.1 To obtain full advantage of the power
8.2 It is also necessary to satisfy the
9 The shower circuit should be separated from
9.1 The current rating will be reduced if the
identifiable, but out of reach of a person
using a fixed bath or shower, except for the
cord of a cord operated switch, and should
be placed so that it is not possible to touch
the switch body while standing in a bath or
shower cubicle. It should be readily
accessible to switch off after using the
shower.
rooms other than bathrooms, all socket
outlets in those rooms must be protected by
a 30mA RCD.
must be at least that of the shower circuit
protection (see Table B).
provided by the shower, use the shortest
cable route possible from the consumer unit
to the shower.
disconnection time and thermal constraints
which means that for any given combination
of current demand, voltage drop and cable
size, there is a maximum permissible circuit
length.
other circuits by at least twice the diameter
of the cable or conduit.
cabling is bunched with others, surrounded
by thermal loft or wall insulation or placed in
areas where the ambient temperature is
above 30°C. Under these conditions,
derating factors apply and it is necessary to
select a larger cable size.
T100e thermostatic care & care plus
E-002-A
will unavoidably be placed in one or more
of the above conditions. This being so, it
is strongly recommended to use a
minimum of 10mm cabling throughout
the shower installation.
9.3 In any event, it is essential that individual
site conditions are assessed by a competent
electrician in order to determine the correct
cable size and permissible circuit length.
Table B
5
Page 8
T100e thermostatic care & care plus
Isolating
stopvalve
Mains
water
supply
Shower
unit
Switch may
be wall
mounted
in accordance
with IEE regs.
Mains electric supply (via double pole switch)
Double
pole
isolating
switch
Separate
permanently
connected
supply from
consumer unit
WATER REQUIREMENTS
Fig.5 Diagrammatic view (not to scale)
WARNING!
If planning to use a silicon seal
around the backplate edge, do not
place sealant in the area of the PRD
exit channel.
Water requirements
The installation must be in accordance with
Water Regulations/Bylaws.
To guarantee activating the heating elements,
the shower must be connected to a mains water
supply with a minimum running pressure of
100kPa (1.0 bar) at a minimum flow rate of nine
litres per minute with a maximum static pressure
of 1 000kPa (10 bar).
Note: If the stated flow rates are not available,
it may not be possible to achieve optimum
performance from the unit throughout the year.
Under site conditions where the power supply is
below 220 volts and the mains water pressure is
above 5 bar, it is recommended to fit a pressure
reducing valve set at 3.5 bar.
Fig.5 shows a typical system layout.
DO NOT use jointing compounds on any pipe
fittings for the installation.
During periods of high ambient temperatures it
may be necessary to select a low power setting
to achieve your preferred shower temperature.
The water supply can be taken from a cold
water storage cistern provided there is a
minimum head of ten metres above the
showerhead. It must be an independent supply
to the shower only.
If it is intended to operate the shower at
pressures above the maximum or below the
minimum stated, contact Customer Service.
6
Page 9
T100e thermostatic care & care plus
Outline of shower tray
Mains cold
water supply
(either top,
side, bottom
or rear entry)
Shower unit
can be mounted
either side
of riser rail
Height of
shower
should
be a
minimum
of 1 metre
from base
Spillover level
Height of
sprayhead
and shower
to suit user's
requirement
Area to keep clear
PRD outlet
SITING OF THE SHOWER
Siting of the shower
IMPORTANT: If installing onto a tiled wall
always mount the unit on the surface of the
tiles. NEVER tile up to the unit.
Refer to fig.6 for correct siting of the shower.
Position the unit where it will NOT be in direct
contact with water from the showerhead.
Position the shower unit vertically.
Allow enough room between the ceiling and the
shower to access the cover top screws.
Note: Water regulations require the showerhead
be ‘constrained by a fixed or sliding attachment
so that it can only discharge water at a point
not less than 25mm above the spill-over level
of the relevant bath, shower tray or other fixed
appliance’. The use of the supplied soap dish will
in most cases meet this requirement, but if the
showerhead can be placed within a bath, basin
or shower tray, then a double check valve, or
similar, must be fitted in the supply pipework to
prevent back-flow.
Pressure relief safety device
A pressure relief device (PRD) is designed into
the shower unit which complies with European
standards. The PRD provides a level of appliance
protection should an excessive build up of
pressure occur within the shower.
DO NOT operate the shower with a damaged or
kinked shower hose, or a blocked showerhead.
This can cause the PRD to operate.
Make sure the PRD outlet at the bottom of the
unit is not blocked (fig.7).
When commissioning, the showerhead must be
removed from the flexible hose. Failure to follow
this procedure may cause the PRD to operate.
Make sure the shower is positioned over a bath
or shower tray because if the PRD operates, then
water will eject from the bottom of the unit.
Should this happen, turn off the electricity and
water supplies to the shower at the isolating
switch and stopvalve. Contact Customer Service
for advice on replacing the PRD.
WARNING!
The shower must not be positioned
where it will be subjected to freezing
W-008-A
conditions.
Fig.6 Diagrammatic view (not to scale)
Fig.7
IMPORTANT: The unit must be mounted on
a flat surface which covers the full width
and length of the backplate. It is important
that the wall surface is flat otherwise
I-002-A
difficulty may be encountered when fitting
the cover and subsequent operation of the
unit may be impaired.
7
Page 10
T100e thermostatic care & care plus
21
mm
INLET
L
L
N
N
INLET
N
N
Olive
Nut
FITTING THE SHOWER TO THE WALL
Fig.8
Fig.11
Fig.12
Fitting the shower to the wall
WARNING!
Check there are no hidden cables or
pipes before drilling holes for wall
plugs. Use great care when using power
W-005-A
tools near water. The use of a residual
current device (RCD) is recommended.
Note: The control lever is an integral part of the
cover — DO NOT attempt to remove it.
Unscrew the two top and one bottom retaining
Fig.10Fig.9
screws. There is no need to completely remove
the screws, just enough to lift the cover from the
backplate. To allow access for the pipe and cable
connections, remove the trimplate by lifting it
away from the backplate.
Entry positions for the mains water are from the
top, bottom or back. Cable entry is via the top,
bottom or back.
Note: Deviations from the designated entry
points will invalidate product approvals.
If bottom surface entry is required, then the
necessary hole will need to be cut out in the
thinned section of the trimplate using a junior
hacksaw and file (fig.8).
If bottom or rear entry is chosen, the pipe trim
will need to be fitted in the top entry position on
the backplate (fig.9). The pipe trim is packaged
separately.
If installing a supply pipe from the bottom, the
centre of the inlet valve to the wall surface is
21mm.
If entry is from the back, the nut of the
compression fitting will be partially behind the
surface of the wall. This area MUST be left clear
when plastering over the pipework to make the
nut accessible for future adjustments.
Note: the distance between the centre of the
inlet valve and the wall is 21mm (fig.10).
To ease the installation of the unit remove the
shaded area shown in fig.11.
8
Page 11
T100e thermostatic care & care plus
. . . . . .
. . . . ..
. . .. ..
. . . .. .
L
L
N
N
. . . . . .
. . . . . .
. . . . ..
. . . . . .
NL
NL
.. . . . .
.. . .. .
.. . .. .
.. . .. .
L
L
N
N
. . . . . .
. . . . . .
. . . . . .
. . . . . .
NL
NL
L
L
N
N
Slide the compression nut and olive onto the
unit inlet pipe. Make sure the inlet filter is in
place before attempting to fit onto the elbow
connector (fig.12).
Turn the unit at an angle similar to that shown in
fig.13. This will allow easier access for fitting the
inlet pipe onto the elbow connector.
Fit the unit, taking care to make sure that the
inlet pipe is connected to the elbow. Once the
inlet pipe is located, carefully turn the unit anticlockwise until it is level and push gently into
place onto the elbow (fig,14).
After choosing the site for the shower, use the
backplate as a template (fig.15) and mark the
three fixing holes.
Drill and plug the wall.
(An appropriate drill bit should be used. If the
wall is brick, plasterboard or a soft building block,
appropriate wall plugs and screws should be fitted).
Secure the unit in place. Do not fully tighten
the screws at this stage, as the fixing holes are
elongated for out of square adjustment after the
plumbing connections has been completed.
Fig.13
Fig.14
Fig.15
9
Page 12
T100e thermostatic care & care plus
Inlet filte
r
PLUMBING CONNECTIONS
Fig.16
WARNING!
The outlet of the shower acts as a
vent and MUST NOT be connected to
anything other than the hose and
IMPORTANT: Using a suitable sealant,
always seal around the incoming pipework
to prevent water entering the wall.
W-004-A
showerhead supplied.
Plumbing connections
Plumbing to be carried out before wiring
DO NOT use jointing compounds on any pipe
fittings for the installation.
DO NOT solder fittings near the shower unit
as heat can transfer along the pipework and
damage components.
Compression fittings MUST be used to connect
to the inlet of the shower.
Note: An additional stopvalve (complying with
Water Regulations) MUST be fitted in the mains
water supply to the shower as an independent
means of isolating the water supply should
maintenance or servicing be necessary.
Procedure
Turn off the water supply either at the mains
stopvalve or the isolating stopvalve. Connect the
mains water supply to the inlet of the shower
via 15mm copper, stainless steel or plastic pipe
using a 15mm x 15mm brass elbow compression
fitting. The plastic filter protrudes from the
inlet (fig.16) so make sure it is in place before
connection.
The compression fitting must be pushed fully
home onto the inlet to ensure full engagement.
Note: The inlet fitting is designed to enter a
compression fitting only. DO NOT use pushfit connectors as full engagement cannot be
guaranteed. DO NOT use excessive force when
making these connections.
IMPORTANT: Before completing the
connection of the water supply to the inlet
of the shower, and in compliance with Water
Regulations, flush out the pipework to remove
all swarf and system debris. This can be
achieved by connecting a hose to the pipework
and turning on the mains water supply long
enough to clear the debris to waste.
Make sure the backplate is square on the wall
and tighten the three retaining screws which
hold it to the wall. Check the backplate is not
distorted when screws are fully tightened.
Turn on the mains water supply and check for
leaks in the pipework connection to the shower.
Note: At this stage no water can flow through
the unit.
10
Page 13
T100e thermostatic care & care plus
L
N
E
Start/stop
switch
Control
PCB
Power
PCB
Connector
socket
Terminal
block
Thermal
cut-out
Pressure
switch
Thermistor
Earth
post
inlet
Solenoid
valve
outlet
Elements
Care Plus only
ELECTRICAL CONNECTIONS
Electrical connectionsFig.17 shows a schematic wiring diagram.
The cable entry points are top, bottom or back.
The cable can be surface clipped, hidden or via
20mm conduit.
Note: Conduit entry can only be from rear.
SWITCH OFF THE ELECTRICITY SUPPLY AT
THE MAINS.
Route the cable into the shower unit and
connect to the terminal block as follows:
Earth cable to terminal marked
Neutral cable to terminal marked N
Live cable to terminal marked L
IMPORTANT: Fully tighten the terminal
block screws and make sure that no cable
insulation is trapped under the screws. Loose
connections can result in cable overheating.
Note: The supply cable earth conductor must
be sleeved. The outer sheath of the supply cable
must be stripped back to the minimum.
The supply cable must be secured either by
routing through conduit or in trunking or by
embedding in the wall, in accordance with
current IEE regulations.
The use of connections within the unit to supply
power to other equipment i.e. extractor fans,
pumps etc. will invalidate the guarantee.
DO NOT switch on the electricity supply until
the cover has been fitted.
Note: The elements on UK models are to 240V
specifications and will give a lower kW rating if
the v oltage supply is below 240V.
Fig.17
11
Page 14
T100e thermostatic care & care plus
Valve
spindle
COMMISSIONING
Fig.18
Fig.19
Commissioning
WARNING!
Before normal operation of the
shower, it is essential the following
commissioning procedure is completed
The first operation of the shower is intended to
flush out any remaining system debris, to make
sure that water is purged through the unit and
that the heater unit contains water before the
elements are switched on.
Refit the trimplate by carefully guiding into the
locating slots in the backplate.
Temporarily fit the cover in order to carry out
the commissioning procedure.
a. Offer the cover to the unit. DO NOT connect
the 14-way ribbon cable at this stage.
b. Make sure the valve spindle has the ‘flat’
and keyway slot uppermost (12 o’clock
position) as shown in fig.18.
c. Make sure the temperature control lever
is positioned correctly — the lever ‘flat’
inside the cover should be uppermost
(fig.19).
d. Carefully locate the cover tags into the
guide pockets on the backplate and make
sure the wires are not trapped.
e. Guide into position so that the control
spindle locates correctly (the ‘flats’ will only
allow the spindle and lever to fit one way).
Should any difficulty arise, recheck the points
above.
While applying slight pressure to the front cover,
secure in position with the three retaining screws.
Fit the flexible hose (but without the
showerhead) to the shower outlet making sure
the outlet of the hose is directed to waste. Check
the supplied sealing washer is in place.
Turn on the water supply to the shower at the
isolating stopvalve. Switch on the electricity
supply to the shower at the isolating switch.
Water will start to flow through the unit and
discharge from the flexible hose.
W-001-A
correctly.
12
Page 15
T100e thermostatic care & care plus
L
L
N
N
It will take about thirty seconds for a smooth
flow of water to be obtained while air and any
debris is being flushed from the shower. When a
smooth flow of water is obtained, disconnect the
electricity supply to the shower at the isolating
switch. This will stop the water flow. Unscrew
the cover retaining screws again and lift the
cover from the backplate.
Attached to the control PCB inside the cover
is a 14-way ribbon cable. The ribbon cable
connector must be plugged into the socket
located on the power PCB inside the unit
(fig.20). The connector can only be correctly
plugged in one way because of a location lug on
the plug. The ribbon cable also has a coloured
edge which is on the right-hand side when
correctly fitted to the socket.
Fig.20
13
Page 16
T100e thermostatic care & care plus
REPLACING THE COVER
IMPORTANT: Before finally fitting the
cover, the following steps must be taken:
a. Check all plumbing connections are
watertight.
b. Check terminal block screws are fully
tightened.
c. Make sure the pipe and cable entering
the unit do not prevent the cover
locating correctly to the backplate.
d. Make sure the valve spindle has the
‘flat’ and keyway slot uppermost (12
o’clock position) as shown in fig.18.
e. Make sure the temperature control
lever has the ‘flat’ inside the cover
uppermost (fig.19).
Replacing the cover
Offer the cover to the unit. Carefully locate
the cover tags into the guide pockets on the
backplate and make sure wires are not trapped.
Guide into position so that the control spindle
locates correctly (the ‘flats’ will only allow the
spindle and knob to fit one way). While applying
slight pressure to the front cover, secure in
position with the three retaining screws.
The flexible hose can be left attached to the
shower outlet. Make sure the supplied sealing
washer is fitted.
Once the riser rail kit is installed, the shower is
ready for normal operation.
14
Page 17
T100e thermostatic care & care plus
Cold button
Power button
Temperature
control lever
Start/Stop
button
Cold setting
indicator
Power
indicators
OPERATING THE SHOWER
Operating the shower
The shower controls are shown in fig.21.
Make sure the water supply is turned fully on.
Switch the electric supply back on at the
isolating switch.
Immediately the start up routine commences
and the four LED’s flash simultaneously three
times (the Care Plus will also emit a single
‘bleep’).
Starting the shower
Press the START/STOP button and water will
begin to flow (the Care Plus will emit a single
‘bleep’). The two power indicators light, to show
the shower is running at full power.
Stopping the shower
Press the START/STOP button (the Care Plus will
emit a single ‘bleep’) and the phased shutdown
will begin. Water continues to flow for a few
seconds, flushing out any remaining hot water.
This guarantees that the next immediate user
does not receive a slug of hot water if standing
under the showerhead when starting the shower.
Using the control buttons
The shower has two control buttons — POWER
and COLD, as shown.
This symbol is for COLD water only.
When pressed, the LED above the button
lights up (the Care Plus will ‘bleep’
once). It will remain in this state until the
power button is pressed.
Note: Adjustment of the temperature control at
this setting has no effect on the force of water
from the showerhead.
This symbol is the POWER button, which
is a toggle switch between full power
and economy power.
WARNING!
Before normal operation of the
shower, it is essential the following
W-001-A
commissioning procedure is completed
correctly.
Fig.21
Note: The shower automatically starts up on the
full power setting.
Economy is for using less power when the
ambient mains temperature is high during hot
months.
15
Page 18
T100e thermostatic care & care plus
Fig.22
Fig.23
If the shower is on full power and the POWER
button is pressed, one of the LED’s below the
button goes out (the Care Plus will also emit a
single ‘bleep’). During this time, the flow rate
decreases to try to achieve the same temperature
as before.
Note: If the temperature setting was high at full
power, then it will not be possible to obtain the
same temperature as before on the economy
setting. The shower will attempt to provide the
highest temperature at the best flow rate.
Adjust the temperature via the temperature
control.
Note: If the stated flow rate required for the unit
cannot be met due to low water pressure, it will
be necessary to operate the shower on economy
power during hot months because of flow rate
limitations entering the unit.
If the shower is on economy power or the cold
setting and the power button is pressed, both
LED’s will light up (and the Care Plus will emit
a single ‘bleep’). During this time, the flow
rate increases to achieve the same temperature
as before or to correspond to the current
temperature control position.
It is advisable to select full power at all times,
except during periods of hot weather.
Adjusting the shower temperature
The showering temperature is varied by turning
the temperature control which changes the mix
of hot water coming from the heater can and
the incoming cold water.
On the display circumference are ten marked
outer segments which represent the total
angular movement of the temperature control.
To increase the shower temperature turn the
temperature control clockwise (fig.22). (The
Care Plus will ‘bleep’ three times when an
outlet temperature of 41°C or above has been
reached).
To decrease the shower temperature turn the
temperature control anti-clockwise (fig.23).
After obtaining your preferred showering
temperature the control can be left as the
normal setting.
16
Page 19
T100e thermostatic care & care plus
Adjustable
stop
Centre
screw
A
WARNING
This appliance is not intended for use
by persons (including children) with
reduced physical, sensory or mental
capabilities, or lack of experience
and knowledge, unless they have
been given supervision or instruction
concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to
ensure that they do not play
with the appliance.
Setting the adjustable temperature stop
This shower unit is fitted with a temperature
stop. This is factory set to allow the full range
of temperatures to be selected. If required,
the temperature stop can be adjusted by the
installer to lock at a selected temperature setting,
according to individual needs.
Procedure
With the cover in place, start the shower as
normal. Set the temperature control to the
maximum required temperature. This can
be with the pointer positioned at any point
between 1 and 10 on the front cover markings.
Make a note of your chosen maximum position.
Turn off the shower and isolate the electricity
supply at the mains.
With a suitable screwdriver, unscrew the three
cover retaining screws and lift the cover from the
backplate.
Inside the cover is the temperature control
(fig.24). With a suitable screwdriver, remove
the centre screw from the adjustable stop.
IMPORTANT: Take care not to disturb the
temperature lever on the front cover from the
position selected.
Lift out the adjustable stop and reposition it at
position ‘A’ (fig.25). Screw the stop back into
position.
IMPORTANT: DO NOT rotate the valve
spindle when the cover is removed as this will
alter your selected temperature.
Offer the cover to the unit and carefully locate
the cover tags into the guide pockets, and the
control spindle into the cover correctly. While
applying slight pressure to the cover, secure in
place with the three retaining screws.
Switch on the electricity supply and start the
shower.
Check that the temperature control lever locks
at a position which provides a satisfactory
showering temperature for all users.
Note: It is advisable to be certain that the
showering temperature is satisfactory by testing
with your hand before stepping under the
showerhead.
Fig.24
Fig.25
CAUTION!
It is recommended that persons who may
have difficulty understanding or operating
the shower controls should not be left
unattended while using the shower. Special
consideration should be given to young
children and the less able bodied.
17
Page 20
T100e thermostatic care & care plus
Low pressure
indicator
OPERATING FUNCTIONS
Fig.26
Operating functions
There will always be a time delay of a few
seconds between selecting a temperature
and the water reaching the stable selected
temperature.
Low pressure
When the low pressure indicator (fig.26)
flashes steadily (the Care Plus will also ‘bleep’
intermittently) it means the water pressure has
fallen below the minimum pressure required
for correct operation of the shower, resulting in
the low pressure switch operating. This switches
off power to the heating elements preventing
any maintained temperature rises. Water will no
longer flow until the unit has been reset.
Press the START/STOP button once to reset the
shower. The low pressure light will go out and
the unit will now be ready for normal operation.
Once normal water pressure is restored, the unit
can be restarted by pressing the START/STOP
button.
Phased shutdown
In use, when the START/STOP button is pressed,
power is switched off to the elements and the
power indicator will extinguish. Water continues
to flow for a few seconds, flushing out any
remaining hot water. This makes sure that the
next immediate user will not receive a slug of
hot water if standing under the showerhead
when starting the shower.
Safety cut-out
The shower is fitted with a thermal cut-out safety
device. In the event of abnormal operation
which could cause unsafe temperatures within
the unit, the device will disconnect the heating
elements.
It will require a visit from a qualified engineer to
find out the nature of the fault and replace the
safety device, once the unit has been repaired.
Note: In normal use, it is normal to leave the
water supply permanently on to the shower unit,
but as with most electrical appliances, the unit
should be switched off at the isolating switch
when not in use.
18
Page 21
T100e thermostatic care & care plus
CLEANING THE INLET FILTER
Inlet filte
r
Instructions for installers and service engineers only
It is recommended that the filter is periodically
cleaned in order to maintain the performance of
the shower.
It is essential that this operation is carried out by
a competent person.
SWITCH OFF THE ELECTRICITY SUPPLY AT
THE MAINS.
Remove the cover. The inlet filter is situated in
the solenoid inlet (fig.27) and can be removed
to clean.
Remove the trimplate to gain access to the filter
and disconnect and remove the compression
fitting. Also, depending on the incoming
pipework arrangements, if there is not enough
slack in the pipework, it could mean the
removing the unit from the wall.
When cleaning the plastic filter, DO NOT use
a sharp object, as it will cause damage. It is
preferable to use an old toothbrush or similar.
INSTRUCTIONS FOR INSTALLERS AND SERVICE ENGINEERS ONLY
Cleaning the inlet filter
Fig.27
19
Page 22
T100e thermostatic care & care plus
CLEANING THE SCALE TRAP
INSTRUCTIONS FOR INSTALLERS AND SERVICE ENGINEERS ONLY
Fig.28
Cleaning the scale trap
It is recommended in hard water areas, the
scale trap is periodically cleaned to maintain the
performance of the shower.
It is essential that this operation is carried out by
a competent person.
SWITCH OFF THE ELECTRICITY SUPPLY AT
THE MAINS.
Remove the cover and unplug the ribbon cable.
The scale trap is located at the lower left-hand
side of the unit. Unscrew the single central
screw (fig.28) then pull off the cap complete
with ‘O’ rings. Be aware of water discharging as
the heater can empties Clean out the trap and
remove all sediment. Flush the can through by
leaving the cap off and switching on the power
at the isolating switch.
Note: Make sure the water that flows out of the
scale trap will safely flow to waste.
Switch off the power at the isolating switch.
Replace the cap making sure the ‘O’ rings are
in place and free from debris. Secure with the
central screw.
Switch the power back on again at the isolating
switch to enable the can to fill with water. Check
for water leakage at the scale trap. When water
flows smoothly from the showerhead, stop the
flow by switching the power off at the isolating
switch.
Reconnect the connection cable, replace the
cover and secure with the three screws.
4.3 Unit malfunction.4.3.1 Contact Customer Service.
incorrect setting.
5.2 Unit malfunction.5.2.1 Contact Customer Service.
5.3 Safety cut-out operated.5.3.1 The thermal safety cut-out device
1.1.1 Blown fuse or circuit breaker.
Check supply. Renew or reset fuse
or circuit breaker. If it fails again,
consult a qualified electrician.
1.1.2 Power cut? Check other appliances
and if necessary, contact local
Electric Supply Co.
qualified electrician or contact
Customer Service.
2.1.1 Switch off the electric supply,
remove the shower cover and plug
in ribbon cable.
3.1.1 Turn anti-clockwise.
4.2.1 Check connections on PCB.
5.1.1 Turn clockwise.
has operated. Have unit checked
by suitably qualified electrician or
contact Customer Service.
6 Low pressure indicator
flashing.
6.1 Water pressure has
dropped below minimum
required.
6.2 Blockage in outlet.6.2.1 Check and clean outlet and/or
6.3 Loose connection on PCB. 6.3.1 Check connection on PCB from
6.1.1 Wait until water pressure has
returned to normal.
showerhead.
pressure switch.
22
Page 25
T100e thermostatic care & care plus
FAULT FINDING
Problem/Symptom Cause Action/Cure
6 Low pressure indicator
flashing.
7 Water continues to flow
when unit is isolated at
isolating switch.
8 Pressure relief device
has operated (water
ejected from PRD tube).
6.4 Blocked connecting tube
to pressure switch.
7.1 Debris in solenoid.7.1.1 Contact Customer Service for
8.1 Blocked showerhead. 8.1.1 Clean or replace blocked
8.2 Twisted/blocked flexible
shower hose.
8.3 Showerhead not removed
whilst commissioning.
6.4.1 Make sure the tube from solenoid
valve to pressure switch is not
kinked or blocked.
advice.
showerhead cartridge and then fit
a new PRD.
8.2.1 Check for free passage through
hose. Replace the hose if necessary,
then fit new PRD.
8.3.1 Fit new PRD. Commission unit with
showerhead removed.
Note: Identify cause of operation before fitting new PRD unit.
When fitting a new PRD, follow the commissioning procedure.
It is advised all electrical maintenance/repairs to the shower
N-003-A
should be carried out by a suitably qualified person.
In the unlikely event of unit failure other than detailed in the fault finding page,
please contact Customer Service for advice.
Y-001-A
23
Page 26
T100e thermostatic care & care plus
Entry Points
Diagram Key:
L
Water Entry Points
Cable Entry Points
L
N
N
24
Page 27
T100e thermostatic care & care plus
As a producer and a supplier of electric showers, Triton Showers is committed to the protection of the environment
WEEE Directive – Policy Statement
via our own environmental policy and the compliance with the WEEE directive.
Triton Showers is fully registered with the Environment Agency under the following schemes:
Repic: Producers take-back scheme (PTS), registration number WEE/EJ3466QV
Valpak: Distributor take-back scheme (DTS), registration number 9659
All our electric products are labelled accordingly with the crossed out wheeled bin symbol. This indicates, for
disposal purposes at end of life, that these products must be taken to a recognised collection points, such as
local authority sites/local recycling centres; this will be free of any charges. Do not return to Triton Showers.
25
Page 28
UK SERVICE POLICY
In the event of a product fault or complaint occurring, the following
procedure should be followed:
1. Telephone Customer Service on 0844 980 0750 having available,
your details including post code, the model number and power
rating of the product, together with the date of purchase and, where
applicable, details of the particular fault.
2. If required, the Customer Service Advisor will arrange
for a qualified engineer to call.
3. All products attended to by a Triton service engineer must be
installed in full accordance with the Triton installation guide
applicable to the product. (Every product pack contains an installation
guide, however, they can also be bought via our Customer Service Spares
Department).
4. Our engineer will require local parking and if a permit is required this
must be available to the engineer on arrival at the call.
5. It is essential that you or an appointed representative (who must
be over 18 years of age) is present for the duration of the service
engineer's visit. If the product is in guarantee you must produce
proof of purchase.
6. Where a call under the terms of guarantee has been booked and
the failure is not product related (i.e. scaling and furring, incorrect
water pressure, pressure relief device operation or electrical/plumbing
installation fault) a charge will be made. A charge will also be issued
if nobody is at home when the service engineer calls or adequate
parking/permit is not available.
7. If the product is no longer covered by the guarantee an up front
fixed fee will be charged before the site visit.
8. Should proof of purchase not be available on an “in-guarantee” call,
or should the service engineer find that the product is no longer
under guarantee, the engineer will charge the same fixed price and
the customer will be expected to pay the engineer before he leaves.
If payment is not made on the day an administration charge will be
added to the fixed charge.
9. If a debt is outstanding from a previous visit, or from any other Triton
purchase. Triton reserves the right to withhold service until the debt
has been settled.
10. Triton takes the health, safety and wellbeing of its employees very
seriously and expects customers to treat all staff members with respect.
Should any employee feel threatened or receive abuse, either verbally
or physically, Triton reserves the right to withhold service and will
support the employee with a legal prosecution.
Replacement Parts Policy
It is the policy of Triton Showers to maintain parts availability for the
duration of production and a period of 5 years thereafter in accordance
with industry standards. In the event of a spare part not being available a
substitute part will be supplied.
Spare parts can be ordered via our online spare parts store, or by
telephoning Triton Spares Department. Payment should be made by
credit/debit card (excluding American Express or Diners Card). Payment
can also be made by pre-payment of a pro-forma invoice, by cheque or
postal order.
Telephone orders are based on information given during of the call.
Before contacting Triton, please verify your requirements using the
information contained in the user guide. Triton cannot accept liability for
incorrect part identification.
TRITON STANDARD GUARANTEE
Triton guarantee this product against all mechanical and
electrical defects arising from faulty workmanship or
materials for a period of two years for domestic use only,
from the date of purchase, provided that it has been
installed by a competent person in full accordance with the
fitting instructions.
Any part found to be defective during this guarantee period
we undertake to repair or replace at our option without
charge so long as it has been properly maintained and
operated in accordance with the operating instructions, and
has not been subject to misuse or damage.
This product must not be taken apart, modified or repaired
except by a person authorised by Triton. This guarantee
applies only to products installed within the United Kingdom
and does not apply to products used commercially. This
guarantee does not affect your statutory rights.
What is not covered:
1. Breakdown due to: a) use other than domestic use by
you or your resident family; b) wilful act or neglect; c) any
malfunction resulting from the incorrect use or quality of
electricity, gas or water or incorrect setting of controls; d)
failure to install in accordance with this installation guide.
2. Claims for missing parts once the product has been
installed.
3. Repair costs for damage caused by foreign objects
or substances.
4. Total loss of the product due to non-availability
of parts.
5. Compensation for loss of use of the product or
consequential loss of any kind.
6. Call out charges where no fault has been found with the
appliance.
7. Call out charges where the water supply cannot be
isolated, this includes consequential losses arising from
unserviceable supply valves.
8. The cost of repair or replacement of pressure relief
devices, showerheads, hoses, riser rails and/or wall
brackets, isolating switches, electrical cable, fuses and/or
circuit breakers or any other accessories installed at the
same time.
9. The cost of routine maintenance, adjustments, overhaul
modifications or loss or damage arising therefrom,
including the cost of repairing damage, breakdown,
malfunction caused by corrosion, furring, pipe scaling,
limescale, system debris or frost.