SmartPro 120V 750VA 500W Line-Interactive Sine
Wave UPS, Tower, Network Card Options, USB, DB9
Serial
MODEL NUMBER: SMART750SLT
Description
Highlights
750VA line interactive tower UPS; Sine wave output
100/110/120V nominal output during brownouts and overvoltages
USB, RS232 and slot for Network Management Card options
Detailed status LEDs; Single line TEL / DSL surge suppression
NEMA 5-15P input; 8 NEMA 5-15R outlets
Package Includes
SMART750SLT UPS System
PowerAlert Software CD-Rom
USB and serial cabling
User manual with warranty information
Tripp Lite's SMART750SLT intelligent, line-interactive sine wave UPS system protects servers, networking accessories and telecommunications equipment from blackouts, voltage fluctuations and transient surges. Large internal batteries offer 15 minutes half load runtime and 5 minutes fully loaded. 750VA/500 watt power handling capability and full-time sine wave output offers guaranteed compatibility with networking, telecom and other sensitive electronic applications. Includes 8 protected NEMA 5-15R output receptacles total, 4 of which offer surge suppression-only for less critical desktop accessories. Supports simultaneous remote monitoring of UPS and site power conditions via built-in network accessory card slot, USB and DB9 serial monitoring ports. Slot for Network Management Card options, such as Tripp Lite'sSNMPWEBCARD network interface. Communications interfaces support messaging of UPS and line power status, plus output power control for delayed or immediate reboot of all connected devices at once. Includes PowerAlert UPS monitoring and unattended shutdown software with management support for an unlimited number of network UPS systems. Built-in audible alarm and LEDs offer status notification for line power, battery power, battery charge level, load level, plus AVR boost and trim operational status information. Network grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges. Also includes single line TEL/DSL or Ethernet line surge suppression. Attractive, all-black tower housing.
Features
SMART750SLT line-interactive UPS offers battery derived sine wave AC output during power outages, voltage regulation during brownouts and overvoltages, plus network-grade AC surge suppression
750VA/500 watt power handling capability with full-time sine wave output offers guaranteed compatibility with networking, telecom and other sensitive electronic devices
Large internal batteries offer runtimes of 17.8 minutes at half load(375VA/250 watts) and 6.5 minutes at full load(750VA/500 watts)
Intelligent battery management system extends battery life
Automatic Voltage Regulation(AVR) circuits maintain user-selectable 100, 110 or 120V nominal output over an input voltage range of 83 to 145V
Includes 8 NEMA 5-15R output receptacles total, 4 with UPS and surge suppression for critical devices and 4 with surge-only protection for less critical accessories
PowerAlert UPS monitoring and unattended shutdown software enables configurable network broadcast messaging, email notification, event logging and running user-defined script commands
Network management interfaces include USB, DB9 serial and slot for Network Management Card options, such as Tripp Lite's SNMPWEBCARD network interface
Communications ports support messaging of UPS and line power status, including on-battery, low-battery, power restored, AC line voltage, DC battery voltage and remaining battery capacity
Supports timed inverter shutoff after unattended shutdown, activate self-test and UPS output power control for delayed or immediate reboot of connected equipment
Supports Tripp Lite's WatchDog software application to restore unresponsive programs by systematically restarting applications, operating systems and ultimately rebooting completely locked computers by momentarily switching UPS power off and back on again(requires optionalWATCHDOGSW)
Status LEDs offer continuous status information of UPS operating parameters and site power quality
Hot-swappable batteries allow on-site battery replacement without powering off connected equipment
Single line TEL/DSL and network Ethernet line surge suppression
Specifications
OUTPUT
Output Volt Amp Capacity (VA)
Output Watt Capacity (Watts)
Power Factor
Nominal Output Voltage(s)
Supported
Nominal Voltage Details
Frequency Compatibility
Output Voltage Regulation (Line
Mode)
Output Voltage Regulation (Battery
Mode)
Output Receptacles
UPS Output Receptacles (Surge
Suppression Only)
750
500
0.7
100V; 110V; 120V
120V default (voltage selection via back panel switches)
50 / 60 Hz
-13%, +15%
+/- 5%
(8) 5-15R
4 UPS outlets, 4 surge-only outlets
Output AC Waveform (AC Mode) |
|
Sine wave |
|
|
|
Output AC Waveform (Battery Mode) |
|
Pure Sine wave |
|
|
|
INPUT |
|
|
|
|
|
Rated input current (Maximum Load) |
|
12A |
|
|
|
Nominal Input Voltage(s) Supported |
|
100V AC; 110V AC; 120V AC |
|
|
|
UPS Input Connection Type |
|
5-15P |
|
|
|
UPS Input Cord Length (ft.) |
|
6 |
|
|
|
UPS Input Cord Length (m) |
|
1.8 |
|
|
|
Recommended Electrical Service |
|
15A 120V |
|
|
|