Transition Networks CRS4F3111-100, CRS4F3115-100, CRS4F3113-100, CRS4F3211-100, CRS4F3114-100 User Manual

...
USER’S GUIDE
CRS4Fxxxx-100
Slide-in-Module Media Converter
RS-485/422 Copper to Fiber
Transition Networks CRS4Fxxxx-100 series media converters are designed to be installed in the PointSystem™ chassis and connect RS-485/422 copper cable to fiber-optic cable at asynchronous data rates upto1.25 Mb/s
The CRS4F31xx-100 media converters use a male DB-9 port for the copper link:
The CRS4F32xx-100 media converters use a 6-position terminal block for the copper link:
* Maximum cable distance is 1200m
(4000’) @ <90 kb/s decreasing logarithmically to 92m (300’) @ 500 kb/s.
**Typical maximum cable distance.
Actual distance is dependent upon the physical characteristics of the network installation.
Installation . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .6
Cable Specifications . . . . . . . . . . .7
Technical Specifications . . . . . . . .9
Troubleshooting . . . . . . . . . . . . .10
Contact Us . . . . . . . . . . . . . . . . .11
Compliance Information . . . . . . .12
Part Number Port One - Copper
DB-9 port
Port Two - Fiber-Optic
CRS4F3111-100 RS-485/422
1200 m (4000 ft)*
ST, 1300 nm multimode 2 km (1.2 miles)**
CRS4F3113-100 RS-485/422
1200 m (4000 ft)*
SC, 1300 nm multimode 2 km (1.2 miles)**
CRS4F3114-100 RS-485/422
1200 m (4000 ft)*
SC, 1310 nm single mode 20 km (12.4 miles)**
CRS4F3115-100 RS-485/422
1200 m (4000 ft)*
SC, 1310 nm single mode 40 km (24.8 miles)**
Part Number Port One - Copper
6-position terminal block
Port Two - Fiber-Optic
CRS4F3211-100 RS-485/422
1200 m (4000 ft)*
ST, 1300 nm multimode 2 km (1.2 miles)**
CRS4F3213-100 RS-485/422
1200 m (4000 ft)*
SC, 1300 nm multimode 2 km (1.2 miles)**
CRS4F3214-100 RS-485/422
1200 m (4000 ft)*
SC, 1310 nm single mode 20 km (12.4 miles)**
CRS4F3215-100 RS-485/422
1200 m (4000 ft)*
SC, 1310 nm single mode 40 km (24.8 miles)**
CRS4F31xx-100
CRS4F32xx-100
2
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
CRS4Fxxxx-100
Installation
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting the switches. Failure to observe this caution could result in damage to, and subsequent failure of, the media converter.
Set the 6-Position Switch
The 6-position switch is located on the side of the media converter. Use a small flat-blade screwdriver or a similar device to set the recessed switches. Refer to the drawing for the locations of the six individual switches.
Switch 1 - 130 ohm resistor on “receive”
up = Disable. down = Enable. (Switch 5 must also be set to “4-wire” (down).)
When enabled, switch 1 inserts a 130 ohm resistor on the wire pair:
• Receive (-) (B) RS-485 4-wire, receive (-) RS-422 and
• Receive (+) (A) RS-485 4-wire, receive (+) RS-422.
Switch 2 - 130 ohm resistor on “transmit”
up = Disable. down = Enable. (Switch 5 must also be set to “2-wire” (up).)
When enabled, switch 2 inserts a 130 ohm resistor on the wire pair:
• Transmit/Receive (-) (B) RS-485 2-wire, transmit (-) RS-422 and
• Transmit/Receive (+) (A) RS-485 2-wire, transmit (+) RS-422.
Switch 3 - 1K ohm “pull-down”
up = Disable. down = Enable. (Switch 5 must also be set to “2-wire” (up).)
When enabled, switch 3 enables a 1K ohm pull-down on the wire:
• Transmit/Receive (-) (B) RS-485 2-wire, transmit (+) RS-422.
Switch 4 - 1K ohm “pull-up”
up = Disable. down = Enable. (Switch 5 must also be set to “2-wire” (up).)
When enabled, switch 4 enables a 1K ohm pull-up on the wire:
• Transmit/Receive (+) (A) RS-485 2-wire, transmit (+) RS-422.
130 ohm resistor on "transmit"
1K ohm "pull-down"
1K ohm "pull-up"
2-wire / 4-wire
130 ohm resistor on "receive"
RS-485 / RS-422
123456
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
3
Installation -- Continued
Switch 5 - 2-wire / 4-wire
up = 2-wire. down = 4-wire.
Set switch 5 to 2-wire (up) to enable the wire pair:
• Transmit/Receive (-) (B) RS-485 2-wire, transmit (-) RS-422 and
• Transmit/Receive (+) (A) RS-485 2-wire, transmit (+) RS-422. for RS-422 2-wire, half-duplex operation.
Set switch 5 to 4-wire (down) to enable the wire pair:
• Receive (-) (B) RS-485 4-wire, transmit (-) RS-422 and
• Receive (+) (A) RS-485 4-wire, transmit (+) RS-422. for RS-422 4-wire, full-duplex operation.
Switch 6 - RS-485 / RS-422
up = RS-485. down = RS-422.
Set switch 6 to RS-485 (up) to prevent echo in the 2-wire mode.
Set switch 6 to RS-422 (down) to allow “transmit only” for the wire pair:
• Transmit/Receive (-) (B) RS-485 2-wire, transmit (-) RS-422 and
• Transmit/Receive (+) (A) RS-485 2-wire, transmit (+) RS-422.
4
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
CRS4Fxxxx-100
Installation -- Continued
Install the Slide-In-Module
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing the media converter. Failure to observe this caution could result in damage to, and subsequent failure of, the media converter.
To install the CRS4Fxxxx-100 media converter slide-in-module:
1. Locate an empty installation slot on the PointSystem™ Chassis.
2. Carefully slide the slide-in-module into the installation slot, aligning the module with the installation guides.
3. Ensure that the module is firmly seated inside the chassis.
4. Push in and rotate the attached panel fastener screw to secure the module to the chassis front.
Install the Fiber Cable
1. Locate or build fiber cable with male, two-stranded TX to RX connectors installed at both ends.
2. Connect the fiber cables to the CRS4Fxxxx-100 media converter as described:
• Connect the male TX cable connector the female TX port.
• Connect the male RX cable connector to the female RX port.
3. Connect the fiber cables to the other device (another media converter, hub, etc.) as described:
• Connect the male TX cable connector the female RX port.
• Connect the male RX cable connector to the female TX port.
CFMFF100
CFMFF100
CETCF100
CFETF100
CFMFF100
SPD
PWR
FRX
CRX
FLNK
CLNK
10/100TX
RX
TX
10/100SX
100BASE-TX
RX
TX 100BASE-FX
Link Alert
E
D
0
50½
LA
PWR
RXF
RXC
LNK
COL
LKS
PWR
LKM
10BASE-2
10BASE-FL
LKS
PWR
LKM
LKS
PWR
LKM
Multimode
Singlemode
TX
RX
TX
RX
Multimode
Singlemode
TX
RX
TX
RX
Multimode
Singlemode
TX
RX
TX
RX
I
0
TERM
INIT
RX
TX
LNK
PWR
CPSMM120
SERIAL
10BASE-T
R E S E T
I
0
Fiber
RS-232
RX
TX
P
CRS2F
Panel Fastener Screw
Connect the fiber cable to the media converter as shown.
Connect the fiber cable
to the other device
(media converter,
hub, etc.) as shown
RX
TX
RX
TX
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
5
Installation -- Continued
Install the Copper Cable (DB-9 port)
Install the copper cable as instructed if the media converter has a DB-9 copper port (CRS4F31xx-100 models).
NOTE: Shielded RS-485/422 cables are required for EMC compliance.
1. Locate or build RS-485/422 cables with a female DB-9 connector on one end and a DB-9 connector that is compatible with the other device on the other end of the cable.
2. Connect the female DB-9 connector at one end of cable to the male DB­9 port on the CRS4F31xx-100 media converter.
3. Connect the DB-9 connector at the other end of the cable to the DB-9 port on the other device.
Power the Media Converter
The media converter is powered through the PointSystem™ chassis.
Install the Copper Cable (6-position terminal block)
Install the copper cable as instructed if the media converter has a 6-position terminal block (CRS4F32xx-100 models).
NOTE: Shielded RS-485/422 cables are required for EMC compliance.
1. Locate or build RS-485/422 cables with the six individual wires stripped at both ends.
2. Insert the individual wires at one end of cable into the six terminal block ports on the CRS4F32xx-100 media converter.
3. Insert the individual wires at the other end of the cable into the six terminal block ports on the other device, matching the same color of cable with the number of the port.
DB-9
X
2
6
3
4
5
1
Loading...