Transition Networks CRS4F3111-100, CRS4F3115-100, CRS4F3113-100, CRS4F3211-100, CRS4F3114-100 User Manual

...
USER’S GUIDE
CRS4Fxxxx-100
Slide-in-Module Media Converter
RS-485/422 Copper to Fiber
Transition Networks CRS4Fxxxx-100 series media converters are designed to be installed in the PointSystem™ chassis and connect RS-485/422 copper cable to fiber-optic cable at asynchronous data rates upto1.25 Mb/s
The CRS4F31xx-100 media converters use a male DB-9 port for the copper link:
The CRS4F32xx-100 media converters use a 6-position terminal block for the copper link:
* Maximum cable distance is 1200m
(4000’) @ <90 kb/s decreasing logarithmically to 92m (300’) @ 500 kb/s.
**Typical maximum cable distance.
Actual distance is dependent upon the physical characteristics of the network installation.
Installation . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .6
Cable Specifications . . . . . . . . . . .7
Technical Specifications . . . . . . . .9
Troubleshooting . . . . . . . . . . . . .10
Contact Us . . . . . . . . . . . . . . . . .11
Compliance Information . . . . . . .12
Part Number Port One - Copper
DB-9 port
Port Two - Fiber-Optic
CRS4F3111-100 RS-485/422
1200 m (4000 ft)*
ST, 1300 nm multimode 2 km (1.2 miles)**
CRS4F3113-100 RS-485/422
1200 m (4000 ft)*
SC, 1300 nm multimode 2 km (1.2 miles)**
CRS4F3114-100 RS-485/422
1200 m (4000 ft)*
SC, 1310 nm single mode 20 km (12.4 miles)**
CRS4F3115-100 RS-485/422
1200 m (4000 ft)*
SC, 1310 nm single mode 40 km (24.8 miles)**
Part Number Port One - Copper
6-position terminal block
Port Two - Fiber-Optic
CRS4F3211-100 RS-485/422
1200 m (4000 ft)*
ST, 1300 nm multimode 2 km (1.2 miles)**
CRS4F3213-100 RS-485/422
1200 m (4000 ft)*
SC, 1300 nm multimode 2 km (1.2 miles)**
CRS4F3214-100 RS-485/422
1200 m (4000 ft)*
SC, 1310 nm single mode 20 km (12.4 miles)**
CRS4F3215-100 RS-485/422
1200 m (4000 ft)*
SC, 1310 nm single mode 40 km (24.8 miles)**
CRS4F31xx-100
CRS4F32xx-100
2
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
CRS4Fxxxx-100
Installation
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when setting the switches. Failure to observe this caution could result in damage to, and subsequent failure of, the media converter.
Set the 6-Position Switch
The 6-position switch is located on the side of the media converter. Use a small flat-blade screwdriver or a similar device to set the recessed switches. Refer to the drawing for the locations of the six individual switches.
Switch 1 - 130 ohm resistor on “receive”
up = Disable. down = Enable. (Switch 5 must also be set to “4-wire” (down).)
When enabled, switch 1 inserts a 130 ohm resistor on the wire pair:
• Receive (-) (B) RS-485 4-wire, receive (-) RS-422 and
• Receive (+) (A) RS-485 4-wire, receive (+) RS-422.
Switch 2 - 130 ohm resistor on “transmit”
up = Disable. down = Enable. (Switch 5 must also be set to “2-wire” (up).)
When enabled, switch 2 inserts a 130 ohm resistor on the wire pair:
• Transmit/Receive (-) (B) RS-485 2-wire, transmit (-) RS-422 and
• Transmit/Receive (+) (A) RS-485 2-wire, transmit (+) RS-422.
Switch 3 - 1K ohm “pull-down”
up = Disable. down = Enable. (Switch 5 must also be set to “2-wire” (up).)
When enabled, switch 3 enables a 1K ohm pull-down on the wire:
• Transmit/Receive (-) (B) RS-485 2-wire, transmit (+) RS-422.
Switch 4 - 1K ohm “pull-up”
up = Disable. down = Enable. (Switch 5 must also be set to “2-wire” (up).)
When enabled, switch 4 enables a 1K ohm pull-up on the wire:
• Transmit/Receive (+) (A) RS-485 2-wire, transmit (+) RS-422.
130 ohm resistor on "transmit"
1K ohm "pull-down"
1K ohm "pull-up"
2-wire / 4-wire
130 ohm resistor on "receive"
RS-485 / RS-422
123456
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
3
Installation -- Continued
Switch 5 - 2-wire / 4-wire
up = 2-wire. down = 4-wire.
Set switch 5 to 2-wire (up) to enable the wire pair:
• Transmit/Receive (-) (B) RS-485 2-wire, transmit (-) RS-422 and
• Transmit/Receive (+) (A) RS-485 2-wire, transmit (+) RS-422. for RS-422 2-wire, half-duplex operation.
Set switch 5 to 4-wire (down) to enable the wire pair:
• Receive (-) (B) RS-485 4-wire, transmit (-) RS-422 and
• Receive (+) (A) RS-485 4-wire, transmit (+) RS-422. for RS-422 4-wire, full-duplex operation.
Switch 6 - RS-485 / RS-422
up = RS-485. down = RS-422.
Set switch 6 to RS-485 (up) to prevent echo in the 2-wire mode.
Set switch 6 to RS-422 (down) to allow “transmit only” for the wire pair:
• Transmit/Receive (-) (B) RS-485 2-wire, transmit (-) RS-422 and
• Transmit/Receive (+) (A) RS-485 2-wire, transmit (+) RS-422.
4
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
CRS4Fxxxx-100
Installation -- Continued
Install the Slide-In-Module
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing the media converter. Failure to observe this caution could result in damage to, and subsequent failure of, the media converter.
To install the CRS4Fxxxx-100 media converter slide-in-module:
1. Locate an empty installation slot on the PointSystem™ Chassis.
2. Carefully slide the slide-in-module into the installation slot, aligning the module with the installation guides.
3. Ensure that the module is firmly seated inside the chassis.
4. Push in and rotate the attached panel fastener screw to secure the module to the chassis front.
Install the Fiber Cable
1. Locate or build fiber cable with male, two-stranded TX to RX connectors installed at both ends.
2. Connect the fiber cables to the CRS4Fxxxx-100 media converter as described:
• Connect the male TX cable connector the female TX port.
• Connect the male RX cable connector to the female RX port.
3. Connect the fiber cables to the other device (another media converter, hub, etc.) as described:
• Connect the male TX cable connector the female RX port.
• Connect the male RX cable connector to the female TX port.
CFMFF100
CFMFF100
CETCF100
CFETF100
CFMFF100
SPD
PWR
FRX
CRX
FLNK
CLNK
10/100TX
RX
TX
10/100SX
100BASE-TX
RX
TX 100BASE-FX
Link Alert
E
D
0
50½
LA
PWR
RXF
RXC
LNK
COL
LKS
PWR
LKM
10BASE-2
10BASE-FL
LKS
PWR
LKM
LKS
PWR
LKM
Multimode
Singlemode
TX
RX
TX
RX
Multimode
Singlemode
TX
RX
TX
RX
Multimode
Singlemode
TX
RX
TX
RX
I
0
TERM
INIT
RX
TX
LNK
PWR
CPSMM120
SERIAL
10BASE-T
R E S E T
I
0
Fiber
RS-232
RX
TX
P
CRS2F
Panel Fastener Screw
Connect the fiber cable to the media converter as shown.
Connect the fiber cable
to the other device
(media converter,
hub, etc.) as shown
RX
TX
RX
TX
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
5
Installation -- Continued
Install the Copper Cable (DB-9 port)
Install the copper cable as instructed if the media converter has a DB-9 copper port (CRS4F31xx-100 models).
NOTE: Shielded RS-485/422 cables are required for EMC compliance.
1. Locate or build RS-485/422 cables with a female DB-9 connector on one end and a DB-9 connector that is compatible with the other device on the other end of the cable.
2. Connect the female DB-9 connector at one end of cable to the male DB­9 port on the CRS4F31xx-100 media converter.
3. Connect the DB-9 connector at the other end of the cable to the DB-9 port on the other device.
Power the Media Converter
The media converter is powered through the PointSystem™ chassis.
Install the Copper Cable (6-position terminal block)
Install the copper cable as instructed if the media converter has a 6-position terminal block (CRS4F32xx-100 models).
NOTE: Shielded RS-485/422 cables are required for EMC compliance.
1. Locate or build RS-485/422 cables with the six individual wires stripped at both ends.
2. Insert the individual wires at one end of cable into the six terminal block ports on the CRS4F32xx-100 media converter.
3. Insert the individual wires at the other end of the cable into the six terminal block ports on the other device, matching the same color of cable with the number of the port.
DB-9
X
2
6
3
4
5
1
6
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
CRS4Fxxxx-100
Operation
After installation, the media converter should function without operator intervention. Use the status LEDs to monitor the media converter operation in the network.
PWR On The media converter is connected to external power.
RXF On A link has been established with the fiber link.
RXC On Data has been received on the copper link.
Flashing Data is transferring on the copper link.
CRS4F31xx-100 CRS4F32xx-100
Fiber
DB-9
RX
TX
PWRRXC
CRS4F
RXF
Fiber
RX
TX
CRS4F
2
6
3
4
5
1
PWRRXC
RXF
SNMP
Use SNMP at an attached terminal or at a remote location to monitor the media converter by monitoring:
• Local fiber link status
• Receive data activity on the copper link
• Local switch settings
(Network commands cannot be entered via SNMP.)
See the on-line documentation that comes with Transition Networks FocalPoint™ software for applicable commands and usage on-line at: www.transition.com
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
7
Cable Specifications
RS-485/422 Copper Cable
Maximum Data Rate: 1.25 Mb/s Gauge: 24 to 22 AWG Maximum Cable Distance: 1200m (4000 ft) @ <90 kb/s
decreasing logarithmically to: 92m (300 ft) @ 500 kb/s
DB-9 port:
6-position terminal block:
Signal Ground
Not Used
Receive (-) (B) RS-485 4-wire, (-) RS-422
Not Used
Receive (+) (A) RS-485 4-wire, (+) RS-422
Not Used
Transmit/Receive (+) (A) RS-485 2 or 4-wire, (+) RS-422
Not Used
Transmit/Receive (-) (B) RS-485 2 or 4-wire, (-) RS-422
Protective Ground
5
1
2
3
4
6
7
8
9
Ground
2
Transmit/Receive (-) (B) RS-485 2 or 4-wire, (-) RS-422
6
Receive (-) (B) RS-485 4-wire, (-) RS-422
3
Receive (+) (A) RS-485 4-wire, (+) RS-422
4
Transmit/Receive (+) (A) RS-485 2 or 4-wire, (+) RS-422
5
Ground
1
8
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
CRS4Fxxxx-100
Cable Specifications -- Continued
Fiber Cable
Bit Error Rate: <10-9 Single mode fiber (recommended): 9 µm Multimode fiber (recommended): 62.5/125 µm Multimode fiber (optional): 100/140, 85/140, 50/125 µm
CRS4F3111-100 1300 nm multimode Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
CRS4F3113-100 1300 nm multimode Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
CRS4F3114-100 1310 nm single mode Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -31.0 dBm max: -8.0 dBm Link Budget: 16.0 dB
CRS4F3115-100 1310 nm single mode Fiber-optic Transmitter Power: min: -8.0 dBm max: -2.0 dBm Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm Link Budget: 26.0 dB
CRS4F3211-100 1300 nm multimode Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
CRS4F3213-100 1300 nm multimode Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
CRS4F3214-100 1310 nm single mode Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -31.0 dBm max: -8.0 dBm Link Budget: 16.0 dB
CRS4F3215-100 1310 nm single mode Fiber-optic Transmitter Power: min: -8.0 dBm max: -2.0 dBm Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm Link Budget: 26.0 dB
The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
9
Technical Specifications
For use with Transition Networks Model CRS4Fxxxx-100 or equivalent
Data Rate 0 to 1.25 Mb/s
Dimensions 3.4" x 5.0" x 0.86" (86 mm x 127 mm x 22 mm)
Shipping Weight 3 oz. (91 g) (approximately)
Power Consumption 5 Watts
MTBF 671,957 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
2,731,072 hours (Bellcore7 V5.0)
Environment Tmra*: 0 to 50°C (32° to 122° F )
Storage Temp: -40° to 85°C (-40° to 185°F) Humidity: 5 to 95%, non condensing Altitude: 0 to 10,000 feet
Warranty Lifetime
*Manufacturer’s rated ambient temperature. Tmra range for this slide-in-module depends on the physical characteristics and the installation configuration of the Transition Networks PointSystem chassis in which this slide-in-module will be installed.
The information in this user’s guide is subject to change. For the most up-to-date information on the CRS4Fxxxx-100 media converter, view the user’s guide on­line at: www.transition.com
NOTE: The stand-alone version of the media converter is SRS4Fxxxx-100. For more information, see the SRS4Fxxxx-100 user guide on-line at: www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
CAUTION: Visible and invisible laser radiation when open. Do not stare into the beam or view directly with optical instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.
10
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
CRS4Fxxxx-100
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:
1. Is the PWR (Power) LED on the media converter illuminated? NO
• Is the media converter inserted properly into the chassis?
• Is the power cord properly installed in the chassis and in the
grounded AC outlet?
• Does the grounded AC outlet provide power?
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
• Proceed to step 2.
2. Is the RXC LED illuminated when data is sent across the RS-485/422 copper link? NO
• Check the RS-485/422 copper cable for proper connection.
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
• Proceed to step 3.
3. Is the RXF (fiber link) LED illuminated? NO
• Disconnect and reconnect the fiber cables to restart the initialization
process.
• Verify that the TX and RX cables on the media converter are
connected to the RX and TX ports, respectively, on the other media converter.
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
• Proceed to step 4.
4. Does the data fail to move across the link, even though both RXC and RXF LEDs are illuminated? YES
• Check switches 5 and 6 (page 3) for proper configuration and check
the the RS-485/422 cables for proper connection.
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
NO
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
11
Contact Us
Technical Support
Technical support is available 24 hours a day. US and Canada: 1-800-260-1312 International: 00-1-952-941-7600
Transition Now
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
techsupport@transition.com
Address
Transition Networks 6475 City West Parkway Minneapolis, MN 55344, USA telephone: 952-941-7600 toll free: 800-526-9267 fax: 952-941-2322
Declaration of Conformity
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: CRS4Fxxxx-100 Series Media Converter Part Number: CRS4F3111-100, CRS4F3113-100, CRS4F3114-100,
CRS4F3115-100, CRS4F3211-100, CRS4F3213-100, CRS4F3214-100, CRS4F3215-100
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the CRS4Fxxxx-100 to which this declaration refers is in
conformity with the following standards.
CISPR 22:1993; EN 55022:1998+A1:2000 Class A; EN 55024:1998; FCC Part 15 Subpart B; 21 CFR subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
_November 3, 2003_____
Stephen Anderson, Vice-President of Engineering Date
Compliance Information
CISPR22/EN55022 Class A + EN55024 CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für Gegenmaßnahmen verantwortlich.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées.
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2004-2005 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic, or mechanical - without written permission from Transition Networks.
Printed in the U.S.A.
33280.B
Loading...