Transition Networks CRMFE1014-200, CRMFE1016-200, CRMFE1018-200, CRMFE1015-200, CRMFE1019-200 User Manual

...
* Typical maximum cable distance.
Actual distance is dependent upon the physical characteristics of the network.
Installation . . . . . . . . . . . . . . . . . .3
Operation . . . . . . . . . . . . . . . . . . .7
Cable Specifications . . . . . . . . . .11
Technical Specifications . . . . . . .13
Troubleshooting . . . . . . . . . . . . .14
User’s Guide
CRMFE10xx-20x - Chassis SRMFE10xx-20x - Stand-Alone
Fast Ethernet
100Base-TX to 100Base-FX
Remote Converter Management
SRMFE10xx-20x
(remote)
Part Number Port One - Copper
100Base-TX
Port Two - Duplex Fiber-Optic 100Base-FX
CRMFE1011-200 SRMFE1011-200
RJ-45 100 m (328 ft)*
ST, 1300 nm multimode 2 km (1.2 miles)*
CRMFE1013-200 SRMFE1013-200
RJ-45 100 m (328 ft)*
SC, 1300 nm multimode 2 km (1.2 miles)*
CRMFE1014-200 SRMFE1014-200
RJ-45 100 m (328 ft)*
SC, 1310 nm single mode 20 km (12.4 miles)*
CRMFE1015-200 SRMFE1015-200
RJ-45 100 m (328 ft)*
SC, 1310 nm single mode 40 km (24.8 miles)*
CRMFE1016-200 SRMFE1016-200
RJ-45 100 m (328 ft)*
SC, 1310 nm single mode 60 km (32.3 miles)*
CRMFE1017-200 SRMFE1017-200
RJ-45 100 m (328 ft)*
SC, 1550 nm single mode 80 km (49.7 miles)*
CRMFE1018-200 SRMFE1018-200
RJ-45 100 m (328 ft)*
MT-RJ, 1300 nm multimode 2 km (1.2 miles)*
CRMFE1019-200 SRMFE1019-200
RJ-45 100 m (328 ft)*
LC, 1310 nm single mode 20 km (12.4 miles)
CRMFE1025-200 SRMFE1025-200
RJ-45 100 m (328 ft)*
MT-RJ, 1310 nm single mode 20 km (12.4 miles)*
(local)
CRMFE10xx-20x
Transition Networks CRMFE10xx-20x and SRMFE10xx-20x series fast Ethernet media converters connect 100Base-TX shielded or unshielded twisted-pair copper cable to 100Base­FX fiber-optic cable.
The media converters are designed to be installed in pairs where the CRMFE10xx-20x is the local media converter and the SRMFE10xx-20x is the remote media converter.
CRMFE10xx-20x / SRMFE10xx-20x
2
24-hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Optional Accessories for the SRMFE10xx-20x (sold separately).
*Typical maximum cable distance. Actual distance is dependent upon the physical
characteristics of the network. (TX = transmit, RX = receive)
Part Number Description SPS-1872-SA Optional External Power Supply; 18-72VDC Stand-Alone
Output: 12.6VDC, 1.0 A
SPS-1872-PS Optional External Power Supply; 18-72VDC Piggy-back;
Output: 12.6VDC, 1.0 A
E-MCR-04 12-Slot Media Converter Rack (includes universal internal power
supply) 17 x 15 x 5 in. (432 x 381 x 127 mm)
WMBL Optional Wall Mount Brackets; Length: 4.0 in. (102 mm) WMBV Optional Vertical Mount Bracket; Length: 5.0 in. (127 mm) WMBD Optional DIN Rail Mount Bracket; Length: 5.0 in. (127 mm) WMBD-F Optional DIN Rail Mount Bracket (flat); Length: 3.3in. (84 mm)
Part Number Port One - Copper
100Base-TX
Port Two - Fiber-Optic - 100Base-FX single fiber single mode
CRMFE1029-200 SRMFE1029-200
RJ-45 100 m (328 ft)*
SC, 1310 nm TX / 1550 nm RX 20 km (12.4 miles)*
CRMFE1029-201 SRMFE1029-201
RJ-45 100 m (328 ft)*
SC, 1550 nm TX / 1310 nm RX 20 km (12.4 miles)*
A CRMFE1029-200 or a SRMFE1029-200 is to be installed with either a CRMFE1029-201 or a SRMFE1029-201; where one is the local converter and the other is the remote converter.
CRMFE1029-202 SRMFE1029-202
RJ-45 100 m (328 ft)*
SC, 1310 nm TX / 1550 nm RX 40 km (24.8 miles)*
CRMFE1029-203 SRMFE1029-203
RJ-45 100 m (328 ft)*
SC, 1550 nm TX / 1310 nm RX 40 km (24.8 miles)*
A CRMFE1029-202 or a SRMFE1029-202 is to be installed with either a CRMFE1029-203 or a SRMFE1029-203; where one is the local converter and the other is the remote converter.
CRMFE1039-200 SRMFE1039-200
RJ-45 100 m (328 ft)*
LC,1300 nm multimode, 2 km (1.2miles)*
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
3
Installation
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when setting the 4-position switch and the jumpers and when installing the CRMFE10xx-20x slide-in-module into the PointSystem™ chassis.
Failure to observe this caution could result in damage to, and subsequent failure of, the media converter.
Set the 4-Position Switch
SRMFE10xx-200: The switch is on the side of the media converter housing.
CRMFE10xx-20x: The switch is on the media converter ciruit board.
Use a small flatblade screwdriver or a similar device to set the recessed switches. Refer to the drawing (above) for the locations of the four individual switches.
1. Twisted-Pair Auto-Negotiation
up Enable Auto-Negotiation for the copper connection (see page 8). down Disable Auto-Negotiation for the copper connection.
2. Twisted-Pair Pause Feature
up Enable Pause feature for the copper connection (see page 9). down Disable Pause feature for the copper connection
3. Link Pass-Through
up Enable Link Pass-Through (see page 8). down Disable Link Pass-Through.
4. Far-End Fault
up Enable Far-End Fault (see page 9). down Disable Far-End Fault.
Link Pass-Through (up = enable)
Pause (up = enable)
A
uto-Negotiation (up = enable)
Far End Fault (up = enable)
1234
CRMFE10xx-20x / SRMFE10xx-20x
4
24-hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Installation -- Continued
Set the Jumpers
Both jumpers are located on the media converter circuit board.
Enable/Disable AutoCross™
The AutoCross jumper is labeled “J2”. The drawing illustrates the two settings:
Disable Either straight-through or crossover twisted-
pair copper cable must be installed, according to the site requirements
Enable The media converter connects automatically
to either straight-through or crossover twisted-pair copper cable (see page 9).
NOTE: Factory default is “enable AutoCross.” Transition networks recommends leaving the deivce in the “enable” mode.
Hardware/Software Mode
The Hardware/Software mode jumper is labeled “J6”. The drawing illustrates the two settings:
Hardware The media converter mode is determined by
the 4-position switch settings (see the “4­Position switch” section on page 3).
Software The media converter mode is determined by
the most-recently saved, on-board microprocessor settings.
Setting the Jumpers
To set the jumpers on the CRMFE10xx-20x, use small needle-nosed pliers or similar device to move the jumper to the desired position.
To set the jumpers on the SRMFE10xx-20x:
1. Using a small screwdriver, remove the four (4) screws that secure the cover to the media converter.
2. Carefully remove the cover from the media converter and locate the jumper on the circuit board.
3. Using small needle-nosed pliers or similar device, move the jumper to the desired position.
4. Carefully replace the cover on the media converter and replace the four (4) screws that secure the cover to the media converter.
Software Mode
Hardware Mode
H
S
H
S
Disable Autocross
Enable Autocross
DE
DE
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
5
Installation -- Continued
Install the CRMFE10xx-20x Slide-In-Module
CAUTION: Slots in the PointSystem™ chassis without a slide-in-module installed MUST have a protective plate covering the empty slot for Class A and/or Class B compliance.
To install the CRMFE10xx-20x media converter slide-in-module:
1. Locate an empty installation slot on the PointSystem™ chassis.
2. Carefully slide the slide-in-module into the installation slot, aligning the module with the installation guides.
3. Ensure that the module is firmly seated inside the chassis.
4. Push in and rotate the attached panel fastener screw clockwise to secure the module to the chassis front.
CFMFF100
CFMFF100
CETCF100
CFETF100
CFMFF100
SPD
PWR
FRX
CRX
FLNK
CLNK
10/100TX
RX
TX
10/100SX
100BASE-TX
RX
TX 100BASE-FX
Link Alert
E
D
0
50½
LA
PWR
RXF
RXC
LNK
COL
LKS
PWR
LKM
10BASE-2
10BASE-FL
LKS
PWR
LKM
LKS
PWR
LKM
Multimode
Singlemode
TX
RX
TX
RX
Multimode
Singlemode
TX
RX
TX
RX
Multimode
Singlemode
TX
RX
TX
RX
I
0
TERM
INIT
RX
TX
LNK
PWR
CPSMM120
SERIAL
10BASE-T
R E S E T
I
0
panel fastener screw
PWR
Install the Copper Cable
1. Locate or build 100Base-TX compliant copper cables with male, RJ-45 connectors installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the CRMFE10xx-20x (local) media converter.
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on the other (local) device (switch, workstation, etc.).
4. Repeat steps 2 and 3 for the SRMFE10xx-20x (remote) media converter.
5. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on the other (remote) device (switch, workstation, etc.).
RJ-45 port
on the other device
(switch, work station, etc.)
RJ-45 port
on the media
converter
Loading...