Installation
Single Chassis Option
The CPSMM-200 management module is designed be installed into a
Transition Networks PointSystem™ chassis to enables network management
of any media converter slide-in-modules installed in the chassis. The
following chassis are available:
• CPSMC0800-100, 8-slot PointSystem™ chassis
• CPSMC13xx-100, 13-slot PointSystem™ chassis
• CPSMC18xx-xxx, 18-slot PointSystem™ chassis
• CPSMC19xx-100, 19-slot PointSystem™ chassis
10BASE-T
INPORT
OUTPORT
12C
12C-1TERM
INIT
RX
TX
LNK
PWR
RESET
The CPSMM-200 management module is installed
in one of the Transition Network PointSystemTM chassis.
(Configuration for the 13-slot, 18-slot, or 19-slot chassis is shown.)
Cascade Option
The management module cascade option allows the network administrator to
connect up to eight (8) PointSystem™ chassis into one manageable stack,
providing a single management source for up to 143 conversion devices.
To create the cascade option, the CPSMM-200 dual-slot master management
module is installed in the first chassis in the series. The CPSMM-210 singleslot expansion management module is installed in each subsequent chassis.
Pwr
RESET
12C
12C-1
TERM
INIT
Pwr
RESET
12C
12C-1
TERM
INIT
10BASE-T
INPORT
MCCM10
MGMT MASTER
RX
TX
LNK
PWR
OUTPORT
RESET
12C
12C-1TERM
INIT
DB-9
The CPSMM-200
management module is
installed in the first
chassis in the series
The CPSMM-210
management module is
installed in each
subsequent chassis
Installation -- Continued
Redundant Management Option
An alternative setup involves installing two CPSMC-200 dual-slot master
management modules into two adjacent chassis for redundant management.
Redundant management can also be set up with the two CPSMM-200
modules installed in the same chassis.
In this set-up, the two modules auto-negotiate; where one is the primary
module while the other is in stand-by mode. If the primary module fails, the
stand-by module automatically takes over and manages the network.
Replacing the CPSMM-200
The CPSMM-200 can be hot-swapped, that is, it can be replaced while the
PointSystem™ chassis is powered. However, please note that:
• If there are two management modules installed in the same network, the
stand-by module will continue to manage the network while the primary
module is replaced. Also, the stand-by module will retain all network
settings.
• If there is only one management module installed, all SNMP management
operations will cease once the module is removed. The newly installed
management module must be reconfigured to resume network
management.
Replacing the CPSMM-210
The CPSMM-210 can also be hot-swapped. However, unlike the CPSMM200, the network’s management settings do not need to be reconfigured if the
CPSMM-210 is replaced.
For more information on installing or replacing the management modules, see
the user’s guide for the chassis in which the module will be installed. The
chassis manuals can be found on the Web at: www.transition.com.
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
5
10BASE-T
INPORT
MCCM10
MGMT MASTER
RX
TX
LNK
PWR
OUTPORT
RESET
12C
12C-1TERM
INIT
DB-9
The CPSMM-200
management module is
installed in the first
chassis in the series
Another CPSMM-200
managment module is
installed in the next
chassis as a backup
10BASE-T
INPORT
MCCM10
MGMT MASTER
RX
TX
LNK
PWR
OUTPORT
RESET
12C
12C-1TERM
INIT
DB-9