Performance
Climate Changer
Next generation air handler from Trane
™
Trane Performance Climate
Changer™ Air Handler
• Two-inch, R-13 foam-injected panels with
mid-span, internal thermal breaks and
standard thermal break access doors. The
no-through-metal design delivers thermal
performance that helps ensure condensation
will not form on the casing exterior, even with
55°F supply air temperature and unit external
conditions of 81°F dry bulb and 73°F wet
bulb.
• Filter technology that exceeds LEED
requirements and reduces pressure drops
up to 50 percent versus previous designs.
Trane has a history of combining customer needs,
engineering expertise, advanced technology and
cutting-edge innovation to provide superior
products that deliver exceptional performance.
The next generation of Trane air handlers
continues this tradition.
Superior performance
The Performance air handler has the tightest
casing in the commercial ARI market, meeting an
ASHRAE 111 Class 6 leakage level. This leakage
rate is better than most custom designs. Superior
performance features include:
• Low-leak casing design that achieves less than
1.0 percent leakage rate and can withstand
+/- 8 inches w.g. static pressure, with no more
than 0.0042 inch deflection.
Energy ecient
Trane has designed even the most basic
features to encourage energy conservation,
allowing the system to surpass minimum
ASHRAE Standard 90.1 requirements.
The Performance air handler delivers:
• Superior performance
• Industry-leading energy efficiency
• System optimization
• Highest quality
• Lowest installed cost
2 Trane Peformance Climate Changer™ Air Handler
Energy ecient components include:
System optimization
• Positional service lights with light emitting
diode (LED) fixtures, which last up to ten
times longer than fluorescent bulbs and one
hundred times longer than incandescent bulbs,
while using only 2–10 watts of electricity.
• Traq™ dampers, an AMCA 611-certified
airflow monitoring solution with standard
and low-flow options, which allow direct
measurement and control of outdoor and
return airflow. The low-flow Traq damper is
a key part of a demand control ventilation
strategy to help drive down energy costs.
• High-eciency coil fins deliver superior
heat-transfer eciency while allowing face
velocities in excess of 625 fpm without
moisture carryover.
• Discharge plenums and plenum fan sections,
which are available with variable size, type and
location of openings, to reduce static pressure
loss and lower energy consumption.
The Trane EarthWise™ design philosophy
incorporates high-eciency air handlers and
water chillers with low-flow rates and low
temperatures on both the waterside and airside.
Benefits include:
• Reduced emissions
• Lower first cost
• Lower operating cost
• Improved acoustical performance
• Smaller equipment and components
• Better comfort with lower space humidity
Low-temperature, low-flow systems can be
challenging, but the Performance air handler is
engineered to capitalize on the benefits of an
EarthWise system:
• Low-leak casing design incorporates foam-
injected and mid-span internal thermal break
panels and standard thermal break access
doors to minimize condensation from low-
leaving air temperatures.
The Trane EarthWise™
design philosophy
incorporates high
efficiency air handlers
and water chillers with
low flow rates and low
temperatures
on both the waterside
and airside.
3