Trane Performance Climate Changer™ Air Handler
•   Two-inch, R-13 foam-injected panels with 
mid-span, internal thermal breaks and 
standard thermal break access doors. The 
no-through-metal design delivers thermal 
will not form on the casing exterior, even with 
55°F supply air temperature and unit external 
conditions of 81°F dry bulb and 73°F wet 
bulb.
•   Filter technology that exceeds LEED 
requirements and reduces pressure drops  
up to 50 percent versus previous designs. 
Trane has a history of combining customer needs, 
engineering expertise, advanced technology and 
cutting-edge innovation to provide superior 
products that deliver exceptional performance. 
The next generation of Trane air handlers 
continues this tradition.
Superior performance
The Performance air handler has the tightest 
casing in the commercial ARI market, meeting an 
ASHRAE 111 Class 6 leakage level. This leakage 
rate is better than most custom designs. Superior 
performance features include: 
•   Low-leak casing design that achieves less than 
1.0 percent leakage rate and can withstand 
+/- 8 inches w.g. static pressure, with no more 
than 0.0042 inch deflection.
Energy ecient
Trane has designed even the most basic  
features to encourage energy conservation, 
allowing the system to surpass minimum  
ASHRAE Standard 90.1 requirements. 
The Performance air handler delivers:
  •  Superior performance 
  •  Industry-leading energy efficiency 
  •  System optimization 
  •  Highest quality 
  •  Lowest installed cost
2  Trane Peformance Climate Changer™ Air Handler 
Energy ecient components include: 
System optimization
•   Positional service lights with light emitting 
diode (LED) fixtures, which last up to ten 
times longer than fluorescent bulbs and one 
hundred times longer than incandescent bulbs, 
while using only 2–10 watts of electricity.
•   Traq™ dampers, an AMCA 611-certified 
airflow monitoring solution with standard 
and low-flow options, which allow direct 
measurement and control of outdoor and 
return airflow. The low-flow Traq damper is 
a key part of a demand control ventilation 
strategy to help drive down energy costs.
•   High-eciency coil fins deliver superior  
heat-transfer eciency while allowing face 
velocities in excess of 625 fpm without 
moisture carryover.
•   Discharge plenums and plenum fan sections, 
which are available with variable size, type and 
location of openings, to reduce static pressure 
loss and lower energy consumption.
The Trane EarthWise™ design philosophy 
incorporates high-eciency air handlers and 
water chillers with low-flow rates and low 
temperatures on both the waterside and airside. 
Benefits include:
•  Reduced emissions 
•  Lower first cost 
•  Lower operating cost 
•  Improved acoustical performance 
•  Smaller equipment and components 
•  Better comfort with lower space humidity
Low-temperature, low-flow systems can be 
challenging, but the Performance air handler is 
engineered to capitalize on the benefits of an 
EarthWise system: 
•   Low-leak casing design incorporates foam-
injected and mid-span internal thermal break 
panels and standard thermal break access  
doors to minimize condensation from low-
leaving air temperatures.
The Trane EarthWise™
design philosophy
incorporates high
efficiency air handlers
and water chillers with
low flow rates and low
temperatures
on both the waterside
and airside.
3