Package Contents
AV200 Nano Powerline Adapter
Quick Installation Guide
AV200 Nano Powerline Adapter
MODEL NO.
TL-PA2010
pair
Powerline Adapter
*
Resource CD
* The provided power plug may dier from the picture due to dierent
regional power specications. Here we take the EU version as an example.
QIG
Ethernet Cable
Warning on Final Location
200Mbps
pair
NOTE:
It's strongly recommended that you plug the adapter directly into the
wall socket, for some power strips have surge protector which can lter data.
7106503975
pair
TL-PA2010
LED and Button Descriptions
1
200Mbps
Power LED
Powerline LED
Ethernet LED
pair
Pair Button
Item Status Description
Solid
The adapter is on.
Power LED
Powerline LED
Ethernet LED
*
Five minutes after the device connected to the adapter is turned o, the adapter will
automatically switch to power-saving mode.
Item
Pair Button
The adapter is in power-saving mode or in pairing
Blinking
procedure.
O
The adapter is o.
Solid
The adapter is connected to a powerline network.
Blinking
The adapter is transferring data.
The adapter isn’t connected to any powerline network
O
or is in power-saving mode. *
The Ethernet port is connected, but there is no data
Solid
being transferred.
Blinking
The Ethernet port is transferring data.
O
The Ethernet port isn’t connected.
Description
Pair button is used to secure a powerline network. To secure
your network, please refer to Appendix: Using the Pair Button.
Network Installation
2
Wall Socket
pair
.
After taking the steps above, y
Wall Socket
pair
ou can surf the Internet
To add another adapter
Plug an additional adapter into the wall socket, and the connection will be
established automatically within 60 seconds.
NOTE:
1.
To surf the Internet, please make sure that your network is properly
connected to the Internet.
2.
If the adapters fail to automatically link to each other, you can
establish a private group by using the pair button. To set up a private
group, please go to Appendix Using the Pair Button for detailed
instructions.
Appendix: Using the Pair Button (Setting up a private group)
To set up a private group :
1.
Press the pair button on adapter A for 1 second and the Power
LED will begin ashing.
2.
Within 2 minutes, press the pair button on adapter B for 1
second and the Power LED will begin ashing as well.
3.
In about 60 seconds you’ll see the Powerline LED on both
adapters light up, indicating the two adapters have
intercommunicated with each other successfully.
* It is highly recommended to rst set up the two adapters as close as
possible and then place them in a suitable location.
To join an existing private group:
If you want to add adapter C to the existing private group, please
follow the steps.
Press the pair button on the adapter A or B for 1 second (do not
1.
press both), and the Power LED will begin ashing.
Within 2 minutes press the pair button on adapter C for 1 second,
2.
the Powerline LED on the adapter C will light up in about 60
seconds.
* You can follow the steps above to add more adapters to the private
group one by one.
A B
pair
Router
C
pair
Set-Top Box&TV
pair
Desktop
NOTE:
More advanced conguration, such as reset, rmware upgrade and rename device can be accessed through the utility, so install the Powerline
Utility if necessary. (Only for Windows).
For detailed instructions, please refer to the User Guide on the Resource CD.
Technical Support
Troubleshooting
Q1. I have followed the above instructions, but my adapters
are still not working. What can I do?
Make sure all the adapters are under the same electric meter.
1.
2.
If the Power LED does not light up at all, there may be a
hardware problem.
3.
The PLC devices might not communicate with each other if they
are in dierent phrases of a four-wire three-phase circuit.
4.
As some power strips have surge protector, please make sure
the adapters are not separated by the power strips.
Q2. The adapters were working ne but no longer work
now that they've been moved. How do I make them
work again?
Plug the adapters into the same power strip and follow Appendix
Using the Pair Button to pair them . If they still don’t work, please
check for possible interference causes:
Air-conditioners, washing machines, and other similar household
1.
appliances are working too close to the adapters.
Air switch may lead to failed communication among PLC devices;
2.
check whether there are air switches hindering communication.
For more troubleshooting help, go to:
http://www.tp-link.com/en/support/faq
To download the latest Firmware, Driver, Utility and User Guide, go to:
http://www.tp-link.com/en/support/download
For all other technical support, please contact us by using the following details:
Global
Tel: +86 755 26504400
E-mail: support@tp-link.com
Service time: 24hrs, 7 days a week
UK
Tel: +44 (0) 845 147 0017
E-mail: support.uk@tp-link.com
Service time: 24hrs, 7 days a week
Turkey
Tel: 444 19 25 (Turkish Service)
E-mail: support.tr@tp-link.com
Service time: 9:00 AM to 9:00 PM
7 days a week
Ukraine
Tel: 0-800-505-508
E-mail: support.ua@tp-link.com
Service time: Monday to Friday
14:00 PM to 22:00 PM
Brazil
Toll Free: 0800-770-4337 (Portuguese
Service)
E-mail: suporte.br@tp-link.com
Service time: Monday to Saturday
08:00 AM to 08:00 PM
France
Tel: +33 (0) 820 800 860 (French service)
Email: support.fr@tp-link.com
Fee: 0.118 EUR/min from France
Service time: Monday to Friday 9:00 AM to
6:00 PM (Except French Bank holidays)
Russian Federation
Tel: 8 (499) 754-55-60
8 (800) 250-55-60 (toll-free call from
any RF region)
E-mail: support.ru@tp-link.com
Service time: From 10:00 to 18:00
(Moscow time)
*Except weekends and holidays in Russian
Federation
Switzerland
Tel: +41 (0) 848 800998 (German Service)
E-mail: support.ch@tp-link.com
Fee: 4-8 Rp/min, depending on rate of
dierent time
Service time: Monday to Friday 9:00 AM to
6:00 PM. GMT+ 1 or GMT+ 2
(Daylight Saving Time)
TP-LINK TECHNOLOGIES CO., LTD.
Singapore
Tel: +65 62840493
E-mail: support.sg@tp-link.com
Service time: 24hrs, 7 days a week
USA/Canada
Toll Free: +1 866 225 8139
E-mail: support.usa@tp-link.com
Service time: 24hrs, 7 days a week
Australia/New Zealand
Tel: AU 1300 87 5465
NZ 0800 87 5465
E-mail: support.au@tp-link.com
support.nz@tp-link.com
Service time: 24hrs, 7 days a week
Italy
Tel: +39 0230519020
E-mail: support.it@tp-link.com
Service time: Monday to Friday
9:00 AM to1:00 PM, 2:00 PM to 6:00 PM
Indonesia
Tel: (+62) 021 6259 135
E-mail : support.id@tp-link.com
Service time : Monday to Friday
9:00 -12:00; 13:00 -18:00
*Except public holidays
Malaysia
Tel: 1300 88 875465 (1300 88TPLINK)
Email: support.my@tp-link.com
Service time: 24hrs, 7 days a week
Poland
Tel: +48 (0) 801 080 618 / +48 22 7217563
(if calls from mobile phone)
E-mail: support.pl@tp-link.com
Service time: Monday to Friday
9:00 AM to 5:00 PM. GMT+1 or GMT+2
(Daylight Saving Time)
Germany/Austria
Tel: +49 1805 875465 (German Service)
+49 1805 TPLINK
E-mail: support.de@tp-link.com
Fee: 0.14 EUR/min from the German xed
phone network and up to 0.42 EUR/min
from mobile phone
Service time: Monday to Friday 9:00 AM to
6:00 PM. GMT+ 1 or GMT+ 2
(Daylight Saving Time in Germany)
*Except bank holidays in Hesse