Toshiba RAS-22SAV-E, RAS-18SKV-E, RAS-22SKV-E, RAS-18SAV-E Owners Manual

OWNER’S MANUAL
065003.indb
/25/08 0:4:43 AM
ENGLISH
EN
ESPAÑOL
FRANÇAIS
ITALIANO
DEUTSCH
PORTUGUÊS
POLSKI
PУCСКИЙ
HRVATSKI
MAGYAR
TÜRKÇE
NEDERLANDS
ΕΛΛΗΝΙΚΑ
SVENSKA
ES FR IT DE PT PL CZ
ÿESKY
RU
CR HU TR NL
GR
SV
AIR CONDITIONER (SPLIT TYPE)
For general public use
Indoor unit
RAS-18, 22 SKV(R) Series
Outdoor unit
RAS-18, 22 SAV Series
065003.indb
FI
SUOMI
NORSK
ROMÂNĄ
БЪЛГАРСКИ
LATVISKI
SLOVENÿINA
SLOVENŠÿINA
NO DK
DANSK
RO
EE
EESTI
LV SK SI
/25/08 0:4:43 AM
PRECAUTIONS FOR SAFETY
065003.indb 2
/25/08 0:4:49 AM
• Do not install, repair, open or remove the cover. It may expose you to dangerous voltages. Ask the dealership or the specialist to do this.
• Turning off the power supply will not prevent potential electric shock.
• The appliance shall be installed in accordance with national wiring regulation.
• Means for disconnection from the supply having a contact separation of at least 3 mm in all poles must be incorporated in the fi xed wiring.
WARNING
• Do not expose your body directly to cool air for a long time.
• Do not insert your fi nger or any article into the air inlet/outlet.
• When an abnormality (burning smell, etc.) occurs, stop the air conditioner and turn off the circuit breaker.
• Installation must be requested from the supplying retail dealership or professional installation vendors. Installation requires special knowledge and skill. If customers install on their own, it can be a cause of fi re, electric shock, injury or water leakage.
• Do not select a location for installation where fl ammable gas may leak. If there is any gas leakage or accumulation around the unit, it can be a cause of fi re.
• Do not turn ON/OFF the circuit breaker or operate buttons with a wet hand. It may be a cause of electric shock.
• Do not disassemble, modify or relocate the unit by yourself. It may become the cause of fi re, electric shock, or water leakage. For repair or relocation, please request service from the supplying retail dealership or a Toshiba dealership.
• Do not select a location for installation where there may be excessive water or humidity, such as a bathroom. Deterioration of insulation may be a cause of electric shock or fi re.
• When relocating or repairing the unit, please contact the supplying retail dealership. When there is a kink in the wiring, it may be the cause of electric shock or fi re.
• During an error (such as a burning odor, not cooling, or not warming), stop operating the unit and turn off the circuit breaker. Continuous operation may be a cause of fi re, or electric shock. Please request repair or service from the supplying retail dealership or a Toshiba dealership.
• Earth work should be requested from the supplying retail dealership or professional vendors. Insuffi cient grounding work may be the cause of electric shock. Do not connect the earth wire to a gas pipe, water pipe, lightning conductor, or telephone earth wire.
• If the indoor unit piping outlet is exposed due to relocation, close the opening. Touching internal electrical parts may cause injury or electric shock.
• Do not insert any material (metal, paper, or water, etc) into the air outlet or air intake opening. Fan may be rotating at high speed inside or there are high voltage sections, which may cause an injury or electric shock.
• You must use a independent power outlet for the power supply. If a power outlet other than the independent outlet is used, it may cause a fi re.
• When the air-conditioning unit does not cool or warm, there may be a leakage of refrigerant. Please consult the supplying retail dealership. The refrigerant used in the air-conditioning unit is safe. It will not leak under normal operating conditions but if it leaks into the room and contacts a heat source such as a heater, or stove, it may cause a harmful reaction.
• When water or other foreign substances enter the internal parts, stop operating the unit immediately and turn off the circuit breaker. Operating the unit continuously may cause fi re or electric shock. Please contact the supplying retail dealership for repair.
• Do not clean the inside of the air-conditioning unit yourself. Please request internal cleaning of the air-conditioning unit from the supplying retail dealership. Incorrect cleaning may cause breakage of resin parts or insulation defects of electrical parts, causing water leakage, electric shock or fi re.
• Do not damage or modify the power cable. Do not connect the cable midway, or use a multiple outlet extension cord that is shared by other devices. Failure to do so may cause fi re.
• Do not place heavy objects on the power cable, expose it to heat, or pull it. To do so may cause electrical shock or fi re.
DANGER
• Check that the circuit breaker is installed correctly. If the circuit breaker is not
CAUTION
properly installed, it may cause an electric shock. To check the installation method, please contact the supplying retail dealership or the professional vendor who installed the unit.
• When using the unit in a closed room, or operating with other combustion appliances, make sure to open a window occasionally for ventilation. Insuffi cient ventilation may cause suffocation due to a lack of oxygen.
• Avoid operating for long periods in a high humidity environment (over 80%) such as with the windows or doors open. There may be condensation on the indoor unit and droplets may fall onto the furniture.
• When the unit won’t be used for a long time, turn off the main switch or the circuit breaker.
• It is recommended that maintenance be performed by a specialist when the unit has been operated for a long time.
• At least once a year check if the mounting table of the outdoor unit is damaged or not. If a damaged state is ignored, the unit may fall or over-turn, causing an injury.
• Stand on a sturdy ladder when attaching/detaching the front panel/air fi lter/air cleaning fi lter. Failure to do so may cause a fall or injury.
• Do not stand on the outdoor unit or place anything on the unit. It may be the cause of injury due to falling or over-turning. Any damage to the unit may cause an electric shock or fi re.
• Do not use combustion appliances in the direct fl ow of the air from the air­conditioning unit. Poor combustion of a combustion appliance may cause suffocation.
• Do not place anything around the outdoor unit or allow fallen leaves to accumulate around it. If there are fallen leaves, small animals could enter and contact internal electrical parts, causing a failure or fi re.
• Do not place animals and plants in places where wind from the air-conditioning unit fl ows directly. It may have a negative infl uence on the animal or plant.
• Ensure that drained water is discharged. When the discharging water process is not suffi cient, water may leak, causing water damage to furniture. To check that the installation method used is correct, please contact the supplying retail dealership or the professional vendor who installed the unit.
• Do not place any containers such as a vase containing fl uid on the unit. It might cause water to enter the unit and deteriorate the electrical insulation, causing an electric shock.
• Do not use for special applications such as storage of food or animals, or to display plants, precision devices, or art objects. Do not use on ships or in other vehicles. It may cause a failure in the air-conditioning unit. In addition, it may damage these items.
• Do not place other electrical appliances or furniture under the unit. Water droplets might fall, causing damage or failure.
• When cleaning, you must stop operating the unit and turn off the circuit breaker. Since the fan inside may be rotating at high speed, it may cause an injury.
• Do not wash the main air-conditioning unit with water. It may cause an electric shock.
• After the front panel/air fi lter is cleaned, wipe away any water and allow to dry. If water remains, it may cause an electric shock.
• Once the front panel is removed, do not touch the metal parts of the unit. It may cause an injury.
• Do not touch the air intake section or the aluminum fi ns of the unit. It may cause injury.
• When you hear thunder and there might be a lightning strike, stop operating the unit and disconnect the circuit breaker. If lightning strikes, it may cause a failure.
• Batteries for remote control unit:
- Should be inserted with correct polarity (+) and (-).
- Should not be recharged.
- Do not use batteries for which the “Recommended usage period” has expired.
- Do not keep used batteries inside the remote control unit.
- Do not mix different types of batteries, or mix new batteries with old ones.
- Do not directly solder the batteries.
- Do not short-circuit, disassemble, heat, or throw batteries into a fi re. If batteries
are not disposed of correctly, they may burst or be the cause of fl uid leakage, resulting in burns or injuries. If touching the fl uid, wash thoroughly with water. If it touches devices, wipe off to avoid direct contact.
- Do not place within reach of small children. If a battery is swallowed, consult a
doctor immediately.
1
Hi POWER FILTER PURE TIMER OPERATION
12
065003.indb 2
INDOOR UNIT DISPLAY
45
3
1 Hi POWER (Green) 2 FILTER (Orange) 3 PURE (Blue) (8, 22SKVR series) 3 PRE. DEF (Preheat/Defrost) (Orange) (8, 22SKV series) 4 TIMER (Yellow)
RESET
5 OPERATION (Green)
6
6 RESET button
/25/08 0:4:49 AM
2
065003.indb 3
/25/08 0:4:57 AM
PREPARATION BEFORE USE
Preparing Filters
. Open the air inlet grille and remove the air fi lters.
2. Attach the fi lters. (see detail in the accessory sheet).
Loading Batteries
. Remove the battery cover.
2. Insert 2 new batteries (AAA type) following the (+) and (–) positions.
Clock Setup
. Push CLOCK
If timer indication is fl ashing, go to the next step 2.
2. Press
3. Press
Remote Control Reset
. Remove the batteries.
2. Press
3. Insert the batteries.
3
AIR FLOW DIRECTION
1
2
3
Note:
• Do not move the louver manually by others.
• The louver may automation positioning by some operation mode.
4
REMOTE CONTROL
1 Infrared signal emitter 2 Start/Stop button 3 Mode select button (MODE) 4 Temperature button (TEMP) 5 Fan speed button (FAN) 6 Swing louver button (SWING) 7 Set louver button (FIX) 8 On timer button (ON) 9 Off timer button (OFF) ! Sleep timer button (SLEEP) " Setup button (SET) # Clear button (CLR) $ Memory and Preset button (PRESET) % One-Touch button (ONE-TOUCH) & High power button (Hi-POWER) ( Economy button (ECO) ) Quiet button (QUIET) ~ Comfort sleep button (COMFORT SLEEP) + Plasma Air Purifi er button (PURE)
(RAS-8, 22SKVR-E Only)
, Filter reset button (FILTER)
- Clock Reset button (CLOCK) . Check button (CHK)
5
ONE-TOUCH
Press the “ONE-TOUCH” button for fully automated operation that is customized to the typical consumer preferences in your region of the world. The customized settings control temperature air fl ow strength, air fl ow direction and other settings to provide you alternate contact with “ONE-TOUCH” of the button. If you prefer other settings you can select from the many other operating functions of your Toshiba unit.
Press
6
AUTOMATIC OPERATION
To automatically select cooling, heating, or fan only operation . Press
2. Press
O
by tip of the pencil.
ON
OFF
or
: adjust the time.
SET
: Set the time.
.
FIX
Press desired vertical direction.
Press automatically and press again to stop.
For horizontal direction, adjust manually.
: Move the louver in the
SWING
: Swing the air
ONE-TOUCH
: Start the operation.
MODE
: Select A.
TEMP
: Set the desired temperature.
PRESET
$
ONE-TOUCH
% 2
QUIET
)
SWING
+ 6 7
TIMER
8
SLEEP
! .
,
1
TEMP
PURE
FIX Hi-POWER ECO
ON
FILTER
CHK
A CL
FAN
MODE
COMFORT
SLEEP
CLR
OFF
SET
CLOCK
7
COOLING / HEATING / FAN ONLY OPERATION
. Press
2. Press Cooling: Min. 7
3. Press HIGH .
8
For dehumidifi cation, a moderate cooling performance is controlled automatically.
2. Press
9
Press The plasma air purifi er and air ionizer can be activated or deactivated by pressing
the PURE button. The air ionizer starts in conjunction with plasma air purifi er operation.
Note: The FILTER indicator (orange) turns on after PURE operation is performed
10
To automatically control room temperature and airfl ow for faster cooling or heating operation (except in DRY and FAN ONLY mode)
Press
11
To automatically control room to save energy (except in DRY and FAN ONLY mode)
Press
Note: Cooling operation; the set temperature will increase automatically degree/
12
In case of the misplaced or discharged remote control
5 4 3 ~
& (
# 9
13
"
-
Set the timer when the air conditioner is operating.
Daily timer allows the user to set both the ON & OFF timers and will be activated on a daily basis.
• During the every day timer is activating, both arrows ( , ) are indicated.
Note:
• The setting will be saved for the next same operation.
MODE
: Select Cool , Heat , or Fan only .
TEMP
: Set the desired temperature.
o
C, Heating: Max. 30oC, Fan Only: No temperature indication
FAN
: Select AUTO, LOW , LOW+ , MED , MED+ , or
DRY OPERATION
. Press
MODE
: Select Dry .
TEMP
: Set the desired temperature.
AIR PURIFYING OPERATION
PURE
to start and stop plasma air purifi er and air ionizer operation.
for about 000 hours.
(RAS-18, 22SKVR-E Only)
Hi-POWER OPERATION
Hi-POWER
: Start and stop the operation.
ECO OPERATION
ECO
: Start and stop the operation.
hour for 2 hours (maximum 2 degrees increase). For heating operation the set temperature will decrease.
TEMPORARY OPERATION
Pressing the RESET button, the unit can start or stop
without using the remote control.
Operation mode is set on AUTOMATIC operation, preset temperature is 25°C and fan operation is automatic speed.
TIMER OPERATION
Setting the ON Timer Setting the OFF Timer
1
PressON : Set the desired ON timer.
2
3
Setting Everyday Timer
1
2
• Keep the remote control in accessible transmission to the indoor unit;
SET
Press
: Set the timer. Press
CLR
Press
: Cancel the timer. Press
PressON: Set the ON timer.
OFF
Press
otherwise, the time lag of up to 5 minutes will occur.
: Set the OFF timer.
Press
3
Press
Press
4
mark fl ashing.
OFF
: Set the desired OFF timer.
SET
: Set the timer.
CLR
: Cancel the timer.
SET
.
SET
button during the ( or )
EN ES FR IT DE PT PL CZ
RU
CR HU TR NL
GR
SV FI NO DK RO
EE LV SK SI
065003.indb 3
/25/08 0:4:57 AM
Loading...
+ 6 hidden pages