MAINTENANCE
If installed on a forced warm air or cooling system where filters are properly installed and maintained no cleaning of the DUCT BOOSTER® blower wheel should be required.
If installed on a gravity warm air heating system which does not include filters, the DUCT BOOSTER® should be removed from the duct and cleaned at the start of each heating season. The motor is permanently lubricated so no oiling is necessary. The DUCT BOOSTER® motor normally runs hot to the touch.
Tjernlund Products, Inc. warrants the components of its products for one year from date of installation. This warranty covers defects in material and workmanship. This warranty does not cover normal maintenance, transportation or installation charges for replace­ment parts or any other service calls or repairs. Products that are tampered with, dam­aged, installed improperly, wired incorrectly or defective due to malfunctioning appliances are not covered under this warranty. This warranty DOES NOT cover the complete DUCT BOOSTER® if it is operable, except for the defective part.
DB-2 REPLACEMENT PARTS LIST
MOTOR KIT 950-7025 WHEEL KIT 950-7010 HOUSING KIT 950-7000
COPYRIGHT © 2000 TJERNLUND PRODUCTS, INC. P/N 8504030 REV. B 09/00
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547 Visit our web site • www.tjernlund.com
TJERNLUND LIMITED ONE YEAR WARRANTY
Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1) year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address list­ed below, postage prepaid. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDI­TIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY. IMPLIED WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY. Some states do not allow limitation on how long an implied war­ranty lasts, so that limitation may not apply to you. In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from State to State. Send all inquiries regarding warranty work to Tjernlund Products, Inc. 1601 9th Street, White Bear Lake, MN 55110-6794. Phone (651) 426-2993 • (800) 255-4208 • Fax (651) 426-9547 or email us at fanmail@tjfans.com.
DUCT BOOSTER
®
MODEL DB-2
DESCRIPTION
The DB-2 DUCT BOOSTER® is designed to increase the flow of heated air in warm air heating systems, or cooled air in central air conditioning systems.
Its size and design limits its use to branch ducts serving individual rooms, not the main supply or “truck line” duct. The DUCT BOOSTER® can be mounted on round or flat ducts. It is frequently installed on a warm air duct of a gravity warm air furnace to provide heating for a basement area.
SPECIFICATIONS
Motor: 120/1/60, 1550 RPM, 40 watts, .52 FLA
GENERAL INFORMATION
NOTE: Under normal operating conditions the motor casing of the DUCTBOOSTER®
will feel hot to the touch. The motor has been designed to run at this temperature and is Recognized by Underwriters Laboratories (UL), This normal operating temperature will not harm the motor provided the operation and maintenance instructions enclosed with each unit are followed.
These units have been factory tested and rated in accordance with AMCA standard 210, test code for air moving devices.
Each DB-2 is electrically factory line tested before shipment. After opening carton, inspect thoroughly for hidden damage. Fan wheel should rotate
freely. If any damage is found, notify freight carrier and your distributor immediately and file a concealed damage claim.
OWNERS INSTRUCTIONS
THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT.
DO NOT DESTROY.
INSTALLATION (Tools Required)
DRILL 1/4” NUT RUNNER 5/16” DRILL BIT 1/4” WRENCH SCREW DRIVER TIN SNIPS
NOTE: If installing the DUCT BOOSTER® on a flat duct, the housing flanges will have to be bent at a 90Oangle before inserting DUCT BOOSTER® into duct. This will allow screws to better align with the speed clips provided.
1.
Opening should be cut in the bottom or top of a horizontal duct or any side of
a vertical duct. The motor shaft will then be in the horizontal position. Apply the mounting template provided to the duct, cut opening and drill four 5/16” holes noted on template.
WIRING DUCT BOOSTER®IN PARALLEL WITH HEAT CYCLE
OR COOLING/BLOWER “ON” CYCLE