Operating Instructions
1. Initial Flush Charge
A. Fill until water reaches slightly above
the charge level (blue line) on indica­tor dial.
B. Add Thetford Aqua-Kem
®
Liquid Holding Tank Deodorant as per instructions on package.
2. To Flush
Depress ush button. (Note: Do not
depress button when unit is empty.)
To Empty RV Model
The Electra Magic is tted with a ter­mination valve on the bottom of the unit. Depending on the installation, follow one of these
procedures:
A. Without holding tank – attach discharge hose to outlet
and open termination valve.
B. With holding tank – open termination valve. This dumps
contents of unit into the holding tank.
To Evacuate Marine Model
See your boat owner’s manual.
Congratulations!
…on your purchase of Thetford’s Electra Magic recirculat
ing
toilet, the most popular recirculating toilet in the world.
This unit is a 100% self-contained sanitation system which requires no pressure water connection or holding tank installation (an optional holding tank may be installed to increase total capacity). The Electra Magic is operated by a simple D.C. hookup, available in a 12-Volt or a 24-Volt model, and may be discharged directly into the sewer or into an optional holding tank.
Unique Filtration
Thetford’s unique ltration system puts an end to unpleasant clogging. The exclusive lter cone assures that only ltered uid is delivered to the recirculating pump.
Any Questions…
about your toilet or this Owner’s Manual?
Simply call Thetford’s
Customer Relations Department at
1-800-521-3032
1-800-543-1219
3
RV Installation Instructions continue on Page 5.
Installation
RV Model
1. Install the two closet bolts in closet ange.
2. While holding bolt up so the head touches underside
of closet ange, install one nut on each bolt and screw
nuts down until they touch top of gauge. If gauge is misplaced, bottom surface of
nuts should be 1.34 in. (3.4 cm) above
oor.
5. Place unit on closet ange and locate position for plastic
locator disc by tracing around one of the front legs. Drill
5/32” dia. hole in oor and fasten disc to oor with at
sides oriented as shown. Use #10 screw provided.
Important: This disc prevents toilet from moving on floor.
6. Lower toilet onto closet ange until nuts on closet bolts
go through rectangular holes in metal brackets, seal rests
on closet ange, and leg locates over locating disc.
4.
Make sure white f o r k - s h a p e d sl ides are in forward posi­tion.
3. Turn the toilet upside-down and install closet ange seal on Slide-EZ Valve with at side against toilet.
Electrical Hookup
RV and Marine Models
Connect your 12-Volt or 24-Volt model Electra Magic directly to the appropriate D.C. source as a separate circuit. Use minimum size #14 gauge wire. (Black wire to positive [hot], white to negative [ground].)
Important – Be sure polarity of power supply has been properly determined and correctly connected to lead wires before operating.
4
MULTIPLE POSITIONS SUMP DISCHARGE
Side Discharge
Rear Discharge
Installation
Marine Model
CAUTION: Toilet is not explosion proof and must not be
located in an area where an explosive atmosphere exists, such as gasoline fumes, etc.
1. Install white fork­shaped slides on brackets. Make one right bracket as­sembly and one left bracket assembly.
(Right bracket assembly shown.)
2. Mount bracket assemblies and sump to bottom of toilet with four screws. Brackets are sandwiched between sump and toilet.
3. Locate toilet position with template and install bolts
in oor drilling 7/32” dia. hole in oor, putting acorn nut on screw, and driving bolts into oor with wrench.
Remove acorn nuts.
4. Also using template, locate position for plastic locator
disc. Drill 5/32” dia. hole in oor and fasten disc to oor with at sides oriented parallel to sides of toilet.
Important: This disc prevents toilet from moving on floor.
5. Install one nut on each bolt and screw nuts down until they
touch top of gauge. If gauge is misplaced, bottom surface of nuts should be 1.34 in. (3.4
cm) above oor.
6. Lower toilet over bolts until nuts go through rectangular holes in metal brackets, and the unit rests on its feet.
Marine Installation Instructions continue on Page 5.