Texas Instruments LM306P, LM306DR, LM306D Datasheet

LM306
DIFFERENTIAL COMPARATOR WITH STROBES
SLCS008A – OCTOBER 1979 – REVISED OCTOBER 1991
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
D
Fast Response Times
D
D
Fanout to 10 Series 54/74 TTL Loads
D
Strobe Capability
D
Short-Circuit and Surge Protection
D
Designed to Be Interchangeable With National Semiconductor LM306
description
The LM306 is a high-speed voltage comparator with differential inputs, a low-impedance high­sink-current (100 mA) output, and two strobe inputs. This device detects low-level analog or digital signals and can drive digital logic or lamps and relays directly. Short-circuit protection and surge-current limiting is provided.
A low-level input at either strobe causes the output to remain high regardless of the differential input.When both strobe inputs are either open or at a high logic level, the output voltage is controlled by the differential input voltage. The circuit will operate with any negative supply voltage between –3 V and –12 V with little difference in performance.
The LM306 is characterized for operation from 0°C to 70°C.
AVAILABLE OPTIONS
PACKAGE
T
A
VIOmax
°
SMALL OUTLINE PLASTIC DIP
at 25 C
(D) (P)
0°C to 70°C 5 mV LM306D LM306P
Copyright 1991, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters.
1 2 3 4
8 7 6 5
GND
IN+ IN–
V
CC–
V
CC+
OUT STROBE 2 STROBE 1
D OR P PACKAGE
(TOP VIEW)
IN–
IN+
STROBE 2
STROBE 1
OUT
functional block diagram
LM306 DIFFERENTIAL COMPARATOR WITH STROBES
SLCS008A – OCTOBER 1979 – REVISED OCTOBER 1991
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
schematic
V
CC–
IN–
IN+
70
STROBE 2
STROBE 1
V
CC+
OUT
GND
6.3 V
6.3 V
6.3 V
6.3 V
5 k
6.3 V
17 k
300
5 k
300
600
3.5 k
600
3
Resistor values are nominal.
LM306
DIFFERENTIAL COMPARATOR WITH STROBES
SLCS008A – OCTOBER 1979 – REVISED OCTOBER 1991
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC+
(see Note 1) 15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Supply voltage, V
CC–
(see Note 1) –15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Differential input voltage, V
ID
(see Note 2) ±5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage, V
I
(either input, see Notes 1 and 3) ±7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Strobe voltage range (see Note 1) 0 V to V
CC+
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage, V
O
(see Note 1) 24 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage from output to V
CC–
30 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Duration of output short circuit to ground (see Note 4) 10 s. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, TA 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltages and the voltage from the output to V
CC–
, are with respect to the network ground.
2. Differential voltages are at IN+ with respect to IN–.
3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 7 V , whichever is less.
4. The output may be shorted to ground or either power supply.
DISSIPATION RATING TABLE
PACKAGE
TA 25°C
POWER RATING
DERATING
FACTOR
DERATE
ABOVE T
A
TA = 70°C
POWER RATING
D P
600 mW 600 mW
5.8 mW/°C
8.0 mW/°C
46°C 75°C
464 mW 600 mW