L293D
QUADRUPLE HALF-H DRIVER
SLRS008A – SEPTEMBER 1986 – REVISED MAY 1990
• 600-mA Output Current Capability Per
Driver
• Pulsed Current 1.2-A Per Driver
• Output Clamp Diodes for Inductive
Transient Suppression
• Wide Supply Voltage Range
4.5 V to 36 V
• Separate Input-Logic Supply
• Thermal Shutdown
• Internal ESD Protection
• High-Noise-Immunity Inputs
• Functional Replacement for SGS L293D
description
The L293D is a quadruple high-current half-H
driver designed to provide bidirectional drive
currents of up to 600-mA at voltages from 4.5 V to
36 V . It is designed to drive inductive loads such as
relays, solenoids, dc and bipolar stepping motors,
as well as other high-current/high-voltage loads in
positive-supply applications.
All inputs are TTL-compatible. Each output is a
complete totem-pole drive circuit with a Darlington
transistor sink and a pseudo-Darlington source.
Drivers are enabled in pairs with drivers 1 and 2
enabled by 1,2EN and drivers 3 and 4 enabled by
3,4EN. When an enable input is high, the
associated drivers are enabled, and their outputs
are active and in phase with their inputs. External
high-speed output clamp diodes should be used
for inductive transient suppression. When the
enable input is low, those drivers are disabled, and
their outputs are off and in a high-impedance
state. With the proper data inputs, each pair of
drivers form a full-H (or bridge) reversible drive
suitable for solenoid or motor applications.
A V
for the logic inputs to minimize device power
dissipation.
The L293D is designed for operation from 0°C
to 70°C.
terminal, separate from V
CC1
CC2
, is provided
NE PACKAGE
(TOP VIEW)
1,2EN
HEAT SINK AND
GROUND
V
1A
2A
3A
4A
†
2
1
7
10
9
15
logic symbol
1,2EN
3,4EN
†
This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
1A
1Y
2Y
2A
CC2
1
2
3
4
5
6
7
8
EN
EN
EN
EN
16
15
14
13
12
11
10
9
V
CC1
4A
4Y
HEAT SINK AND
GROUND
3Y
3A
3,4EN
3
6
11
14
logic diagram
2
1A
1,2EN
3,4EN
H = high-level, L = low level,
X = irrelevant, Z = high-impedance (off)
‡
In the thermal shutdown mode, the
output is in the high-impedance state
regardless of the input levels.
1
7
2A
10
3A
9
15
4A
FUNCTION TABLE
(each driver)
‡
INPUTS
AEN
H
L
X
H
H
L
3
6
11
14
OUTPUT
Y
H
L
Z
1Y
2Y
3Y
4Y
1Y
2Y
3Y
4Y
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
Copyright 1990, Texas Instruments Incorporated
3–1
L293D
High-level input voltage, V
QUADRUPLE HALF-H DRIVER
SLRS008A – SEPTEMBER 1986 – REVISED MAY 1990
schematics of inputs and outputs
EQUIVALENT OF EACH INPUT
V
CC1
Current
Source
Input
GND
TYPICAL OF ALL OUTPUTS
V
CC2
Output
GND
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Logic supply voltage range, V
Output supply voltage range, V
Input voltage range, VI 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, V
–3 V to V
O
Peak output current (nonrepetitive, t ≤ 100 µs) ±1.2 A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, IO ±600 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total dissipation at (or below) 25°C free-air temperature (see Notes 2 and 3) 2075 mW. . . . . . .
Continuous total dissipation at 80°C case temperature (see Note 3) 5000 mW. . . . . . . . . . . . . . . . . . . . . . . . .
Operating case or virtual junction temperature range, T
Storage temperature range, T
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NOTES: 1. All voltage values are with respect to the network ground terminal.
2. For operation above 25°C free-air temperature, derate linearly at the rate of 16.6 mW/°C.
3. For operation above 25°C case temperature, derate linearly at the rate of 71.4 mW/°C. Due to variations in individual device electrical
characteristics and thermal resistance, the built-in thermal overload protection may be activated at power levels slightly above or
below the rated dissipation.
(see Note 1) 36 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CC1
36 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CC2
–40°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
stg
J
CC2
+ 3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
recommended operating conditions
Logic supply voltage, V
Output supply voltage, V
Low-level input voltage, V
Operating free-air temperature, T
†
The algebraic convention, in which the least positive (most negative) value is designated minimum, is used in this data sheet for logic voltage
levels.
3–2
MIN MAX UNIT
CC1
CC2
V
≤ 7 V 2.3 V
p
IH
IL
A
CC1
V
≥ 7 V 2.3 7
CC1
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
4.5 7 V
V
CC1
–0.3
36 V
CC1
†
1.5 V
0 70 °C