CY74FCT2827T
2
Maximum Ratings
[2, 3]
(Above which the useful life may be impaired. For user guidelines, not tested.)
Storage Temperature .................................–65°C to +150°C
Ambient Temperature with
Power Applied.............................................–65°C to +135°C
Supply Voltage to Ground Potential............... –0.5V to +7.0V
DC Input Voltage............................................–0.5V to +7.0V
DC Output Voltage......................................... –0.5V to +7.0V
DC Output Current (Maximum Sink Current/Pin) ......120 mA
Power Dissipation..........................................................0.5W
Static Discharge Voltage............................................>2001V
(per MIL-STD-883, Method 3015)
Operating Range
Range
Ambient
Temperature V
CC
Commercial –40°C to +85°C 5V ± 5%
Electrical Characteristics Over the Operating Range
Parameter Description Test Conditions Min. Typ.
[4]
Max. Unit
V
OH
Output HIGH Voltage VCC= Min., IOH= –15 mA 2.4 3.3 V
V
OL
Output LOW Voltage VCC= Min., IOL= 12 mA 0.3 0.55 V
R
OUT
Output Resistance VCC= Min., IOL= 12 mA 20 25 40 Ω
V
IH
Input HIGH Voltage 2.0 V
V
IL
Input LOW Voltage 0.8 V
V
H
Hysteresis
[5]
All inputs 0.2 V
V
IK
Input Clamp Diode Voltage VCC= Min., IIN= –18 mA –0.7 –1.2 V
I
I
Input HIGH Current VCC= Max., VIN= V
CC
5 µA
I
IH
Input HIGH Current VCC= Max., VIN= 2.7V ±1 µA
I
IL
Input LOW Current VCC= Max., VIN= 0.5V ±1 µA
I
OZH
Off State HIGH-Level Output
Current
VCC= Max., V
OUT
= 2.7V 10 µA
I
OZL
Off State LOW-Level
Output Current
VCC = Max., V
OUT
= 0.5V –10 µA
I
OS
Output Short Circuit Current
[6]
VCC= Max., V
OUT
= 0.0V –60 –120 –225 mA
I
OFF
Power-Off Disable VCC= 0V, V
OUT
= 4.5V ±1 µA
Capacitance
[5]
Parameter Description Typ.
[4]
Max. Unit
C
IN
Input Capacitance 5 10 pF
C
OUT
Output Capacitance 9 12 pF
Notes:
2. Unless otherwise noted, these limits are over the operating free-air temperature range.
3. Unused inputs must always be connected to an appropriate logic voltage level, preferably either V
CC
or ground.
4. Typical values are at V
CC
=5.0V, TA=+25˚C ambient.
5. This parameter is specified but not tested.
6. Not more than one output should be shorted at a time. Duration of short should not exceed one second. The use of high-speed test apparatus and/or sample
and hold techniques are preferable in order to minimize internal chip heating and more accurately reflect operational values. Otherwise prolonged shorting of
a high output may raise the chip temperature well above normal and thereby cause invalid readings in other parametric tests. In any sequence of parameter
tests, I
OS
tests should be performed last.