The TDS3000B Series of Digital Phosphor Oscilloscopes
Provides Unmatched Performance and Portability
at an Affordable Price
The TDS3000B Series packs the power
of a DPO, digital real-time (DRT) sampling
technology, WaveAlert waveform anomaly
detection, OpenChoice documentation
and analysis solutions and five applicationspecific modules into a lightweight,
battery-capable design.
A DPO Provides a Greater Level
of Insight into Complex Signals
The TDS3000B Series DPO delivers
3,600 wfms/s continuous waveform
capture rate to capture glitches and
infrequent events three times faster than
comparable oscilloscopes. Some oscillo-
scope vendors claim high waveform
capture rates for short bursts of time,
but your oscilloscope needs to deliver
these fast waveform capture rates on a
continuous basis – saving minutes, hours
or even days by quickly revealing the
nature of faults so advanced triggers
can be applied to isolate them.
In addition, the TDS3000B DPO’s
real-time intensity grading highlights the
details about the “history” of a signal’s
activity, making it easier to understand
the characteristics of the waveforms
you’ve captured.
Features & Benefits
100 to 500 MHz Bandwidths
5 GS/s Maximum Real-time
Sample Rate, with sin(x)/x
Interpolation
3,600 wfms/s Continuous
Waveform Capture Rate
2 or 4 Channels
Full VGA Color LCD
25 Automatic Measurements
FFT Standard
Multi-language User Interface
QuickMenu Graphical User
Interface for Easy Operation
WaveAlert®Automatic Waveform
Anomaly Detection
OpenChoice®Solutions
Simplify Instrument Control,
Documentation and Analysis
– e*Scope®Web-based
Remote Control
– Built-in Ethernet Port
– GPIB, RS232, VGA
– TDSPCS1 OpenChoice
Software
– WaveStar™Software
– Integration with Third-party
Testing Module
– Extended Video Module
– 601 Serial Digital Video Module
Optional Internal Battery
Operation Up to 3 Hours
Without Line Power
Plug-in Printer for Portable
Documentation of Results
TekProbe®Interface Supports
Active, Differential and Current
Probes for Automatic Scaling
and Units
Applications
Digital Design and Debug
Video Installation and Service
Power Supply Design
Education and Training
Telecommunications
Mask Testing
Manufacturing Test
General Bench Test
Page 2
Digital Phosphor Oscilloscopes
TDS3000B Series
Higher Speeds Demand
Greater Bandwidth
You face faster clock rates and edge
speeds, increasingly complex signals and
mounting time-to-market pressures. The
higher the bandwidth of your oscilloscope,
the more accurate the reproduction of
your signal. The TDS3000B Series offers a
wide range of bandwidths from 100 MHz
to 500 MHz to best suit the needs of your
most demanding projects, so that you
can complete your tasks on time and
with confidence.
Quickly Debug and Characterize
Signals with DRT Sampling
Technology and sin(x)/x
Interpolation
The TDS3000B Series combines unique
digital real-time (DRT) sampling technology
with sin(x)/x interpolation to allow you to
accurately characterize a wide range of
signal types on all channels simultaneously.
This sampling technology makes it possible
to capture high-frequency information, such
as glitches and edge anomalies, that eludes
other oscilloscopes in its class, while sin(x)/x
interpolation ensures precise reconstruction
of each waveform. The result – a complete
view of your signal to speed debug and
characterization.
The TDS3000B Series DPO provides
unmatched insight into complex signal
behavior,such as metastable events.
The TDS3054B’s 5 GS/s real-time sample
rate and sin(x)/x interpolation ensure accurate reconstruction of a 500 MHz sine wave.
Enhanced Troubleshooting Ability
WaveAlert
®
waveform anomaly detection
speeds your troubleshooting tasks by
helping you find those elusive problems
faster. WaveAlert detection monitors the
incoming signals on all channels and will
detect and highlight any waveform that
deviates from the normal waveform being
Even with 2 GS/s sample rate, which
exceeds the Nyquist requirement of 2X
oversampling, this 500 MHz oscilloscope
with linear interpolation does not provide
accurate reconstruction of the same
500 MHz sine wave.
WaveAlert waveform anomaly detection
alerts you to any waveform that deviates
from the “normal”input, such as the glitch
on channel 2.
acquired. Because the TDS3000B
oscilloscope can stop acquisition, sound
a beep, make a hard copy or save the
waveform when it detects an anomaly, you
can run tests over long time periods – even
unattended – to find those challenging,
very infrequent failures.
Digital Phosphor Oscilloscope • www.tektronix.com/tds3000b
2
Page 3
Digital Phosphor Oscilloscopes
TDS3000B Series
Look for unintentional circuit noise with the
TDS3000B Series’ FFT capability.
Simple, Speedy Documentation
and Analysis
OpenChoice
®
solutions deliver simple,
seamless integration between the oscilloscope and the PC. Using a standard
built-in Ethernet port, e*Scope web-based
remote control allows you to control your
TDS3000B oscilloscope from anywhere,
using the Internet and your PC. With the
TDS3GV optional communication
module, floppy disk, TDSPCS1
OpenChoice software and integration
with third-party software, the TDS3000B
Series provides you with multiple choices
to easily capture, transfer, document and
analyze your measurement results. This
seamless integration extends the power
and value of these brilliantly engineered,
affordable oscilloscopes.
Optional application modules enable you
to transform your oscilloscope into a
specialized tool for limit testing, telecommunications mask testing, and video
troubleshooting.
And, with its lightweight, compact size
and battery pack, the TDS3000B Series
oscilloscope can go wherever it is needed.
It weighs only 4.5 kg (9.8 lbs.), with battery
installed. Use the optional plug-in thermal
printer to instantly document your work,
even in the field.
TDS3AAM Advanced Analysis
Module – Adds extended math capability,
arbitrary math expressions, measurement
statistics and additional automated
measurements.
The TDS3000B DPO with the TDS3LIM limit
testing module is ideal for manufacturing
test applications where fast Go/No-Go
decisions are required.
TDS3LIM Limit Testing Module – Offers
fast, accurate Go/No-Go verification that
tested circuits are operating within
intended parameters.
Each Channel
Maximum Record10 K points on all models
Length
Vertical 9-Bits on all models
Resolution
Vertical 1 mV to 10V on all models
Sensitivity (/div)
Vertical Accuracy±2% on all models
Max Input150 V
Voltage (1 MΩ)
Position Range± 5 div on all models
BW Limit20 MHz20 MHz20, 150 MHz20, 150 MHz20, 150 MHz20, 150 MHz20, 150 MHz20, 150 MHz
Input CouplingAC, DC, GND on all models
Input Impedance1 MΩ in parallel with 13 pF or 50 Ω on all models
Selections
Time Base 4 ns to4 ns to2 ns to2 ns to2 ns to1 ns to1 ns to1 ns to
Range10 s/div10 s/div10 s/div10 s/div10s/div10 s/div10 s/div10 s/div
Time Base20 ppm on all models
Accuracy
Display (VGA)Color active matrix LCD on all models
CAT I on all models (300V CAT II with standard 10X probe)
RMS
4
Digital Phosphor Oscilloscope • www.tektronix.com/tds3000b
Page 5
Digital Phosphor Oscilloscopes
TDS3000B Series
TDS3000B DPO provides breakthrough test
speeds for telecommunications line card
testing.The telecom QUICKMENU puts
all the commonly used telecom testing
functions on a single menu.
Acquisition Modes
DPO – Captures and displays complex waveforms,
random events and subtle patterns in actual signal
behavior.DPOs are able to provide 3 dimensions of
signal information in real time:Amplitude, time and
the distribution of amplitude over time.
Peak Detect – High frequency and random glitch
capture. Captures glitches as narrow as 1 ns.
WaveAlert
®
– Monitors the incoming signals on all
channels and alerts the user to any waveform that
deviates from the normal waveform being acquired.
Sample – Sample data only.
Envelope – Max/Min values acquired over one
or more acquisitions.
Average – Waveform data from 2 to 512 (selectable)
acquisitions is averaged.
Single Sequence – Use the Single Sequence
button to capture a single triggered acquisition
sequence at a time.
Custom video trigger allows the TDS3000B
to trigger on standards such as RS343
(26.2 kHz scan rate).
Trigger System
Main Trigger Modes – Auto (supports Roll Mode
for 40 ms/div and slower),Normal.
B Trigger– Trigger after time or events.
Trigger After T ime Range – 13.2 ns to 50 s.
Trigger After Events Range –
1 to 9,999,999 events.
External Trigger Input – >1 MΩ in parallel with
17 pF; Max input voltage is 150V
Trigger Types
RMS
.
Edge – Conventional level-driven trigger. Positive or
negative slope on any channel. Coupling selections:
DC, noise reject, HF reject,LF reject.
Video – Trigger on all lines, odd, even or all fields.
With TDS3VID or TDS3SDI,trigger on individual
lines and on analog HDTV formats (1080i, 1080p,
720p, 480p).
Logic –
PATTERN: Specifies AND, OR, NAND, NOR when true
or false for a specific time.
STATE:Any logic state.Triggerable on rising or falling
edge of a clock. Logic triggers can be used on
combinations of 2 inputs (not 4).
Trace and identify ITU-R BT.601 video
signals with the TDS3SDI 601 Serial
Digital Video Module.
Pulse –
WIDTH (or GLITCH):Trigger on pulse width less than,
greater than, equal to or not equal to a selectable
time limit ranging from 39.6 ns to 50s.
RUNT:Trigger on a pulse that crosses one threshold
but fails to cross a second threshold before crossing
the first again.
SLEW RATE:Trigger on pulse edge rates that are
either faster or slower than a set rate. Edges can
be rising, falling or either.
Comm (requires TDS3TMT)– Provides isolated
pulse triggering required to perform DS1/DS3
telecommunications mask testing per
ANSI T1.102 standard.
Alternate – Sequentially uses each active channel
as a trigger source.
Display any four measurements from any combination of waveforms. Or display all measurements with
measurement snapshot feature. Measurement
*1
statistics.
Thresholds – Settable in percentage or voltage.
Gating – Measurements can be gated using the
screen or vertical cursors.
*1
Requires TDS3AAM module.
Digital Phosphor Oscilloscope • www.tektronix.com/tds3000b
5
Page 6
Digital Phosphor Oscilloscopes
TDS3000B Series
Waveform Processing
Deskew – Channel-to-channel deskew ±10 ns may
be manually entered for better timing measurements
and more accurate math waveforms.
Arithmetic Operators – Add,subtract, multiply,
divide, arbitrary math expressions.
*1
Autoset – Single-button,automatic setup on
selected input signal for vertical, horizontal and
trigger systems.
Display Characteristics
Waveform Style –
Dots, vectors and variable persistence.
Graticules – Full,grid, cross-hair and frame.NTSC,
PAL,SECAM and vectorscope (100% and 75% color
bars) with optional TDS3VID and TDS3SDI video
application modules.
Format – YT, XY and Gated XYZ (XY with Z-axis
blanking available on TDS30X4B only).
I/O Interface
Hard Copy Port (Standard) –
Centronics-type parallel.
Ethernet Port (Standard) –
10Base-T LAN, RJ-45 female.
TDS3GV Communications Module – GPIB
(IEEE 488.2) programmability: Full talk/listen modes;
control of all modes, settings and measurements.
VGA: Monitor output for direct display on large
VGA-equipped monitors. DB-15 female connector,
31.6 kHz sync rate,EIA RS-343A compliant.
RS-232-C interface programmability: Full talk/listen
modes; control of all modes, settings and measurements. Baud Rate up to 38,400. DB-9 male
connector.Programmer manual: 071-0381-02.
Temper ature– +5 ºC to +50 ºC (operating),
–20 ºC to +60ºC (nonoperating).
Humidity – 20% to 80% RH below 32 ºC, derate to
30% RH at 45ºC (operating), 5% to 90% RH below
41 ºC,derate to 30% RH at 60 ºC (nonoperating).
Altitude –
To 3,000m (operating), 15,000 m (nonoperating).
Electromagnetic Compatibility – Meets or
exceeds EN55011 Class A radiated and conducted
emissions; EN50082-1; FCC 47 CFR,Part 15,
Subpart B,Class A; Australian EMC framework;
Russian GOST EMC regulations.
Safety –
UL3111-1, CSA1010.1, EN61010-1,IEC61010-1.
Physical Characteristics
Instrument
Dimensionsmmin.
Width375.014.8
Height176.06.9
Depth149.05.9
Weightkglbs.
Instrument only3.27.0
with battery installed4.59.8
TDS3AAM – Advanced analysis module.
TDS3LIM – Limit test module.
TDS3VID – Extended video application module.
TDS3SDI – 601 serial digital video module.
Requires a 4-channel TDS3000B Series
oscilloscope.
TDS3GV – GPIB,VGA, RS-232 interfaces and
TDSPCS1 OpenChoice
Software.
TDSPCS1 OpenChoice PC Communication
Software – A collection of programs that enable
fast and easy transfer communication between MS
Windows PCs and Tektronix oscilloscopes.Available
in single-license packages and included in TDS3GV
communication module. Minimum system requirements: MS Windows 98 SE/XP Professional/ME/
2000. MS Office 2000 or XP (for TDS toolbars
only) – Excel 2000 or 2002; Word 2000 or 2002.
User manual, quick reference
Has holder for user manual
tiiffiiccaatteeooffCCaalliibbrraattiioonn..
®
PC Communication
6
Digital Phosphor Oscilloscope • www.tektronix.com/tds3000b
Page 7
Digital Phosphor Oscilloscopes
TDS3000B Series
TDS3BATB – Lithium Ion battery pack delivers
up to 3 hours continuous operation without
line power.
WaveStar™Software for Oscilloscopes –
Microsoft Windows 98/ME/2000/NT 4.0 Application.
TDS3BATB –Lithium Ion battery pack for up to 3
hours continuous operation without line power.
TDS3CHG – Fast charger for battery pack.
TDS3PRT – Plug-in printer adds easy, portable
documentation capability to your TDS3000B
oscilloscope.
016-1907-00 – 5-roll pack of paper for TDS3PRT
plug-in thermal printer.
AC3000 – Soft case for carrying instrument.
HCTEK4321 – Hard plastic case for carrying
instrument (requires AC3000).
RM3000 – Rackmount kit.
Service Manual (TDS3000B Series) – English
only (071-0972-00).
TNGTDS01 – Self-paced self-study operator
training kit.
For customer training on this product outside the
U.S. call 1-503-627-7510, inside the U.S. call
1-800-833-9200 ext. 77510.
Recommended Probes
ADA400A – 100X,10X, 1X,0.1X high gain
differential amplifier.
P6243 – 1 GHz, ≤1 pF input C 10X active probe.
TDS3PRT – Plug-in printer provides instant,
portable documentation of your work.
P5205 – 1.3 kV, 100 MHz high voltage differential
probe.
P5210 – 5.6 kV, 50 MHz high voltage differential
probe.
P5100 – 2.5 kV, 100X high-voltage passive probe.
TCP202 – 50 MHz, 15 A AC/DC current probe.
Opt. A0 – North America power.
Opt. A1 – Universal EURO power.
Opt. A2 – United Kingdom power.
Opt. A3 – Australia power.
Opt. A5 – Switzerland power.
Opt. A6 – Japan power.
Opt. A10 – China power.
Opt. A99 – No power cord.
*1
Requires TCPA300 probe amplifier.
*2
Requires TCPA400 probe amplifier.
Tektronix probes are expressly designed
for your oscilloscope, with identical quality
standards and built-in compatibility for
optimum performance.
Opt. C3 – Calibration Service 3 years.
Opt. C5 – Calibration Service 5 years.
Opt. D1 – Calibration Data Report.
Opt. D3 – Calibration Data Report 3 years
(with Opt. C3).
Opt. D5 – Calibration Data Report 5 years
(with Opt. C5).
Opt. R5 – Repair Service 5 years.
Warranty
Three year warranty covering all labor and parts,
excluding probes.
Digital Phosphor Oscilloscope • www.tektronix.com/tds3000b
MMeeaassuurreemmeennttSSoolluuttiioonn..
Series arbitrary function generator pairs
with the TDS3000B,TPS2000,TDS2000
and TDS1000 Series digital oscilloscopes
to deliver the two elements of a complete
measurement solution – stimulus and
acquisition.When combined with the
TDS3000B Series oscilloscopes, it
provides you with a common look and feel
between both instruments to increase
your productivity; high pe r formance in a
small footprint; and stackability,saving
valuable workbench space – all at a
price you can afford.
. We know you depend on
Tektronix instrumentsolutions when you
make and meet critical commitments. So
we make and meet a support commitment you can depend on.Anytime you
need support, anywhere in the world,
The AFG3000
Tektronix Support gives you the lowest
possible exposure to inconvenience,
delay or disruption of operations.
Unsurpassed technical expertise and
experience with 24-hour response to
technical questions
Interactive, online support to request
assistance, check ser vice status or
arrange for training
Industry-leading service turn-around
time
Credible, reliable support with demonstrated on-time delivery
90-day unconditional service warranty
No fine print, no exclusions, no surprises
Global support in more than 50 countries
Depend on Tektronix.
Visit www.tektronix.com/support
Contact Tektronix:
ASEAN / Australasia (65) 6356 3900
Austria +41 52 675 3777
Balkan, Israel, South Africa and other ISE Countries +41 52 675 3777
Belgium 07 81 60166
Brazil & South America 55 (11) 3741-8360
Canada 1 (800) 661-5625
Central East Europe, Ukraine and the Baltics +41 52 675 3777
Central Europe & Greece +41 52 675 3777
Denmark +45 80 88 1401
Finland +41 52 675 3777
France & North Africa +33 (0) 1 69 86 81 81
Germany +49 (221) 94 77 400
Hong Kong (852) 2585-6688
India (91) 80-22275577
Italy +39 (02) 25086 1
Japan 81 (3) 6714-3010
Luxembourg +44 (0) 1344 392400
Mexico, Central America & Caribbean 52 (55) 56666-333
Middle East, Asia and North Africa +41 52 675 3777
The Netherlands 090 02 021797
Norway 800 16098
People’s Republic of China 86 (10) 6235 1230
Poland +41 52 675 3777
Portugal 80 08 12370
Republic of Korea 82 (2) 528-5299
Russia & CIS 7 095 775 1064
South Africa +27 11 254 8360
Spain (+34) 901 988 054
Sweden 020 08 80371
Switzerland +41 52 675 3777
T aiwan 886 (2) 2722-9622
United Kingdom & Eire +44 (0) 1344 392400
USA 1 (800) 426-2200
For other areas contact Tektronix, Inc. at: 1 (503) 627-7111
Updated 5 January 2006
Our most up-to-date product information is available at: