TeeJet CenterLine with Swath Manager 5 User Manual

Automated Boom Section Control
Swath
Manager 5
Swath Manager 5 Functions
Auto control up to five boom sections.
The Rate Controller maintains full control over product application.
Boom Sections are activated and deactivated based on the percentage of boom
overlap setting (0%, 50%, 100%).
0% 50% 100%
98-01166-R0
Installation
Cable 45-05462 & 45-05463
Connect between controller and main harness
Cable 45-05467
Use T-Taps supplied with harness to tap into the signal wire between switchbox or
existing switches and boom shutoff valves.
GPS IN
Not Used
MASTER
BOOM CONTROL
Swath Manager 5
78-08065
ON
P
RO
AUTO MAN
ON
OFF
Rate Controller
Automated Boom Section Control for CenterLine
CenterLine
Cable
SM5 to CenterLine
45-05461
54321
Figure 1: %Overlap Examples
Power Cable
45-05324
AUTO BOOM
ENGAGE
Swath Manager 5
Automated Boom Section Control
DISENGAGE
SPRAYER CONTROL
844-x
SM5 Controller Harness
TeeJet - 45-05462 Raven - 45-05463
Controller Harness
Existing
IGN Sense
Status Detect
(Not used)
Not Used
Valves
CenterLine
GPS IN
SM5 to CenterLine
MASTER
BOOM CONTROL
Swath Manager 5
78-08065
Existing switches or switchbox
45-05461
Cable
Power Cable
45-05324
AUTO
54321
BOOM
ENGAGE
Swath Manager 5
Automated Boom Section Control
DISENGAGE
IGN Sense
Status Detect
(Not used)
SM5 Harness,
Exsisting Switches or Switchbox
45-05467
To Accessory Power
or Battery
Valves
Figure 2: Installation System Diagrams
Wire Splice
-
Page 1 of 2
CenterLine Settings
The Swath Man setting is only available when Swath Manager 5 is detected.
When Swath Manger 5 is detected the Status setting is deactivated.
In Guidance Setup the Width setting is used for guidance only.
Swath Man
1. Select the desired %overlap (0%, 50%, 100%)
2. Enter the number of boom sections 1-5
3. Enter the width for each boom section
4. Set a delay in seconds. This will act as a look ahead to turn booms off and on when entering and exiting an applied zone
SETUP
GUIDANCE
Swath Man
Width
Ahead
Antenna
Alarm
GPS Type
1HZ MSG
NEXT
To Start
% Overlap
Sections
Width 1
Delay
NEXT
To Start
Figure 3: Swath Manager 5 Setup
Swath Manager 5 & Controller Switch Configuration
SWITCH POSITIONS
0%
50%
100%
Swath Manager 5
System
Swath Manager 5 Auto
Boom mode
Swath Manager 5
Manual Boom mode
TeeJet Controller ONLY the controller master switch OFF will
*
force all boom sections OFF.
Controller boom switches ON will force boom sections ON
**
original Master Switch
Controller Boom Switches
or original Boom Switches
Controller Master Switch or
*
ON OFF ON ON Engage
ON OFF ON ON Disengage
**
SM5 Master Switch
Figure 4: Switch Positions
SM5 Boom Switches
Auto Boom Switch
.
Engage / Disengage
For Individual boom section
control use SM5 boom switches
Page 2 of 2
Loading...