Automated Boom Section Control
Swath
Manager 5
Swath Manager 5 Functions
• Auto control up to five boom sections.
• The CenterLine determines when sections are in or out of an applied region.
• The Rate Controller maintains full control over product application.
• Boom Sections are activated and deactivated based on the percentage of boom
overlap setting (0%, 50%, 100%).
0% 50% 100%
98-01166-R0
Installation
Cable 45-05462 & 45-05463
• Connect between controller and main harness
Cable 45-05467
• Use T-Taps supplied with harness to tap into the signal wire between switchbox or
existing switches and boom shutoff valves.
GPS IN
Not Used
MASTER
BOOM CONTROL
Swath Manager 5
78-08065
ON
P
RO
AUTO MAN
ON
OFF
Rate Controller
Automated Boom Section Control for CenterLine
CenterLine
Cable
SM5 to CenterLine
45-05461
54321
Figure 1: %Overlap Examples
Power
Cable
45-05324
AUTO
BOOM
ENGAGE
Swath Manager 5
Automated Boom
Section Control
DISENGAGE
SPRAYER CONTROL
844-x
SM5 Controller Harness
TeeJet - 45-05462
Raven - 45-05463
Controller Harness
Existing
IGN Sense
Status Detect
(Not used)
Not Used
Valves
CenterLine
GPS IN
SM5 to CenterLine
MASTER
BOOM CONTROL
Swath Manager 5
78-08065
Existing switches or switchbox
45-05461
Cable
Power
Cable
45-05324
AUTO
54321
BOOM
ENGAGE
Swath Manager 5
Automated Boom
Section Control
DISENGAGE
IGN Sense
Status Detect
(Not used)
SM5 Harness,
Exsisting Switches or Switchbox
45-05467
To Accessory Power
or Battery
Valves
Figure 2: Installation System Diagrams
Wire Splice
-
Page 1 of 2
CenterLine Settings
• The Swath Man setting is only available when Swath Manager 5 is detected.
• When Swath Manger 5 is detected the Status setting is deactivated.
• In Guidance Setup the Width setting is used for guidance only.
Swath Man
1. Select the desired %overlap (0%, 50%, 100%)
2. Enter the number of boom sections 1-5
3. Enter the width for each boom section
4. Set a delay in seconds. This will act as a look ahead to turn booms off and on when
entering and exiting an applied zone
SETUP
GUIDANCE
Swath Man
Width
Ahead
Antenna
Alarm
GPS Type
1HZ MSG
NEXT
To Start
% Overlap
Sections
Width 1
Delay
NEXT
To Start
Figure 3: Swath Manager 5 Setup
Swath Manager 5 & Controller Switch Configuration
SWITCH POSITIONS
0%
50%
100%
Swath Manager 5
System
Swath Manager 5 Auto
Boom mode
Swath Manager 5
Manual Boom mode
TeeJet Controller ONLY the controller master switch OFF will
*
force all boom sections OFF.
Controller boom switches ON will force boom sections ON
**
original Master Switch
Controller Boom Switches
or original Boom Switches
Controller Master Switch or
*
ON OFF ON ON Engage
ON OFF ON ON Disengage
**
SM5 Master Switch
Figure 4: Switch Positions
SM5 Boom Switches
Auto Boom Switch
.
Engage / Disengage
For Individual boom section
control use SM5 boom switches