Taylor 337 Installation Manual

To the Installer
This machine is designed for indoor use only.
DO NOT install the machine in an area where a
water jet could be used to clean orrinse the machine.Failure to follow this instructionmay result in serious electricalshock.
WATER CONNECTIONS
An adequate cold water supply must be provided with a hand shut-off valve. On the underside rear of the base pan, two 3/8” I.P.S. water connections for inlet and outlet have been provided for easy hook-up. 1/2” inside diameter water lines should be connected to the machine. (Flexible lines are recommended, if local codes permit.) Depending on local water conditions, it may be advisable to install a water strainer to prevent foreign substances from clogging the automatic water valve. There will be only one water “in” and one water “out” connection. DO NOT install a hand shut-off valve on the water “out” line! Water should always flow in this order: first, through the automatic water valve; s econd, through the c ondenser; and third, through the outlet fitting to an opentrapdrain.
In the United States, this equipment is intended to be installed in accordance with the National Electrical Code (NEC), ANSI/NFPA 70--1987. The purpose of the NEC code is the practical safeguarding of persons and property from hazards arising from the use of electricity. This code contains provisions considered necessary for safety. Compliance therewith and proper maintenance willresult in an installation essentially free from hazard!
In all other areas of the world, equipment should be installed in accordance with the existing local codes. Please contact your local authorities.
Stationary appliances which are not equipped with a power cord and a plug or other device to disconnect the appliance from the power source must have an all--pole disconnecting device with a contact gap of at least 3 mm installed in the external installation.
CAUTION: THIS EQUIPMENT MUST BE PROPERLY GROUNDED! FAILURE TO DO SO CAN RESULT IN SEVERE PERSONAL INJURY FROM ELECTRICAL SHOCK!
AIR COOLED UNITS
Air cooled units require a minimum of 6” (152 mm) of clearance around all sides of the freezer to allow for adequate air flow across the condenser(s). Failure to allow adequate clearance can reduce the refrigeration capacity of the freezer and possibly cause permanent damage to the compressor.
ELECTRICAL CONNECTIONS
Each freezer requires one power supply for each data label. Check the data label on the freezer for fuse, circuit ampacity and electrical specifications. Refer to the wiring diagram provided inside of the electrical box, for proper power connections.
050817
Beater rotation must be clockwise as viewed looking into the freezing cylinder.
Note: The following procedures should be performed by a trained service technician.
To correct the rotation on a three-phase unit, interchange any two incoming power supply lines at freezer main terminal block only.
To correct rotation on a single-phase unit, change the leads inside the beater motor. (Follow the diagram printed on the motor.)
Electrical connections are made directly to the terminal block. The terminal block is provided in the main control box located behind the lower front trim.
2
To the Operator
The freezer you have purchased has been carefully engineered and manufactured to give you dependable operation. The Taylor Model 337, when properly operated and cared for, will produce a consistent quality product. Like all mechanical products, this machine will require cleaning and maintenance. A minimum amount of care and attention is necessary if the operating procedures outlined in this manual are followed closely.
This Operator’s Manual should be read before operating or performing any maintenance on your equipment.
Your Model 337 will NOT eventually compensate for and correct any errors during the set-up or filling operations. Thus, the initial assembly and priming procedures are of extreme importance. It is strongly recommended that all personnel responsible for the equipment’s operation study these procedures together in order to be properly trainedand to make sure that no misunderstandings exist.
If you require technical assistance, please contact your local authorized Taylor Distributor.
If the crossed out wheeled bin symbol is affixed to this product, it signifies that this product is compliant with the EU Directive as well as other similar legislation in effect after August 13, 2005. Therefore, it must be collected separately after its use is completed, and cannot be disposed as unsorted municipal waste.
The user is responsible for returning the product to the appropriate collection facility,as specified by your local code.
For additional information regarding applicable local laws, please contact the municipal facility and/or local distributor.
COMPRESSOR WARRANTY
DISCLAIMER
The refrigeration compressor(s) on this machine are warranted for the term indicated on the warranty card accompanying this machine. However, due to the Montreal Protocol and the U.S. Clean Air Act Amendments of 1990, many new refrigerants are being tested and developed, thus seeking their way into the service industry. Some of these new refrigerants are being advertised as drop-in replacements for numerous applications. It should be noted that, in the event of ordinary service to this machine’s refrigeration system, only the refrigerant specified on the affixed data label should be used. The unauthorized use of alternate refrigerants will void your compressor warranty. It will be the owner’s responsibility to make this fact known to any technician he employs.
It should also be noted that Taylor does not warrant the refrigerant used in its equipment. For example, if the refrigerant is lost during the course of ordinary service to this machine, Taylor has no obligation to either supply or provide its replacement either at billable or unbillable terms. Taylor does have the obligation to recommend a suitable replacement if the original refrigerant is banned, obsoleted, or no longer available during the five year warranty of the compressor.
The TaylorCompany willcontinue to monitor the industryand test new alternates as they are being developed. Should a new alternate prove, through our testing, that it would be accepted as a drop-in replacement, then the above disclaimer would become null and void. To find out the current status of an alternate refrigerant as it relates to your compressor warranty, call the local Taylor Distributor or the Taylor Factory. Be prepared to provide the Model/Serial Number of the unit in question.
050817
3
Safety
We at Taylor Company are concerned about the safety of the operator when he or she comes in contact with the freezer and its parts. Taylorhas gone to extreme efforts to design and manufacture built-in safety features to protect both y ou and the service technician. As an example, warning labels have been attached to the freezer to further point out safety precautions to the operator.
IMPORTANT -- Failure to adhere to the following
safety precautions may result in severe personal injury.
Failure to comply with these warnings may also damage the machine and its components. Component damage will result in part replacement expense and service repair expense.
To Operate Safely:
S DO NOT allow untrained personnel to operate
this machine.
S DO NOT operate the freezer unless all service
panels and access doors are restrained with screws.
S DO NOT remove the door, beater and blades, or
drive shaft unless all control switches are in the OFF position.
S DO NOT put objects or fingers in door spout.
Failure to follow these instructions may result in contaminated product or severe personal injury to fingers or hands from hazardous moving parts.
DO NOT operate the freezer without reading this
operator’s manual. Failure to follow this instruction may result in equipment damage, poor freezer performance, health hazards, or personal injury.
S DO NOT operate the freezer unless it is properly
grounded.
S DO NOT attempt any repairs unless the main
power supply to the freezer has been disconnected.
S DO NOT operate the freezer with larger fuses
than specified on the freezer data label.
Failureto follow these instructions may result in electrocution or damage to the machine. Contact your local authorized Taylor Distributor for service.
DO NOT use a water jet to clean or rinse the freezer.
Failure to follow this instruction may result in serious electrical shock.
USE EXTREME CAUTION when removing the
beater assembly. The scraper blades are very sharp and may cause injury.
This freezer must be placed on a level surface. Failure to comply may result in personal injury or equipment damage.
DO NOT obstruct air intake and discharge openings:
A minimumof 6” (152 mm) air space is required on both sides and rear, and 4-- 1/4” (108 mm) on bottom. Failure to follow this instruction may cause poor freezer performance and damage to the machine.
This freezer is designed to operate indoors, under normal ambient temperatures of 70 freezer has successfully performed in high ambient temperatures of 104
NOISE LEVEL: Airborne noise emission does not exceed 78 dB(A) when measured at a distance of 1.0 meter from the surface of the machine and at a height of 1.6 meters from the floor.
_F(40_C) at reduced capacities.
_-- 7 5 _F(21_-- 2 4 _C). The
050817
5