TASCAM CC-222 Technical Information

Important Information for Service Stations and Customers
TECHNICAL INFORMATION
Page 1 of 2
TASCAM CC-222, Click Noise
Symptom:
1. When tape play is stopped by Stop or Pause key, click noise is heard there. The click noise is recorded on CD-R/RW disc if the Stop or the Pause key is pressed while manual dubbing from tape to the CD-R/RW.
2. In case "DUB 1 (TPE --> CD-RW)" mode is cancelled by Stop key of Tape or CD-RW, the click noise is recorded on CD-R/RW disc same as 1).
Solution: Following hardware change is needed. It has been made on the products of S/N 0100001 and up.
* Parts Required 2 pcs. Ceramic Capacitor, 1000 pF P/N 3C013672 1 pce. Transistor, DTA124ES P/N 3S000301 1 pce. Wire, 50 mm P/N 3V000050
1. On In/Out PCB Assy Replace C727 0.1 uF Ceramic Capacitor with 1000 pF one.
In/Out PCB (Solder Side)
No. 0302 DATE 16th January 2003
C727
1. Replace with 1000 pF Ceramic Capacitor.
N-2523
2. On Main PCB Assy
a) Replace C353 0.1 uF Ceramic Capacitor with 1000 pF one.
a) Replace with 1000 pF Ceramic Capacitor.
b) Connect Emitter of an additional DTA124ES Transistor to Emitter of Q314. c) Connect Base of the additional DTA124ES to Test Pad "P-E". d) Fit an additional 50 mm Wire between Collector of the additional DTA124ES and Test Pad "N-EQ". e) Cut foil pattern between U314-Pin 4 and Test Pad "N-EQ".
b) Connect Emitter of the additional DTA124ES.
Q314
U314
e) Cut foil pattern.
C353
Additional DTA124ES
Page 2 of 2 03xx
Main PCB
(Solder Side)
c) Connect Base of the additional DTA124ES.
Test Pad "P-E"
Fix the wire by bond.
d) Fit the 50 mm Wire.
Test Pad "N-EQ"