![](/html/af/af22/af22425bd87c92619f1e62ea69554bfab5455c67fd14d165c0ba194741d23498/bg1.png)
O
N
W
E
I
G
H
T
S
A
N
D
M
E
A
S
U
R
E
S
・
safe place, and make sure it is readily
available whenever neccessary.
Please use this product only after
carefully reading this instruction manual
and fully understanding its contents.
GB/USAF
Instruction Manual
à l’étalonnage
Calibration Manual
Mode d’emploi
Manual de instrucciones
E
Instrucciones de calibración
M
AL
1
R
14-2,1-chome,Maeno-cho,Itabashi-ku Tokyo,Japan
Tel:(03)3968-2123 / (03)3968-7048 Fax:(03)3967-3766
http : //www.tanita.co.jp
© 2006 TANITA Corporation of America. All Rights Reserved.
2625 South Clearbrook Drive
Arlington Heights, Illinois 60005 U.S.A.
Tel : 847-640-9241 Fax : 847-640-9261
http : //www.tanita.com
AP1017201
Notice relativ
Please keep this instruction manual in a
![](/html/af/af22/af22425bd87c92619f1e62ea69554bfab5455c67fd14d165c0ba194741d23498/bg2.png)
Contents
■Instruction Manual 01
■Calibration Manual 07
■Mode d’emploi 09
■Notice relative à l’étalonnage 15
■Manual de instrucciones 17
■Instrucciones de calibración 23
GB/USAFE
![](/html/af/af22/af22425bd87c92619f1e62ea69554bfab5455c67fd14d165c0ba194741d23498/bg3.png)
Name of Parts
02
Cover
Instruction manual
AAWeighing tray
B LCD display
C OFF button
D ON/TARE button
EFLevel gauge
Battery compartment
G Adjustable feet
J
Displayed weight is
gross weight
H
"STABILIZED"Mark
I
"Center of Zero"Mark
K
Displayed weight is
NET weight
B
CDE
F GG
GG
H
I
J
K
GB/USA
Attention
The authorities need to have advance notice if the scale is used for " Legal
for Trade " or commercial applications.
Please notify the weights and measurements department in your local city,
county, or state .
For more details, please ask your scale dealer.
01
This scale is a precision instrument and must be used under certain conditions to
ensure accurate measurement. Please observe the following when using this scale.
1. Never disassemble the unit.
2.
Use in a vibration-free location that is not exposed to direct sunlight.
3. The scale will not measure accurately in an environment subject
to large temperature changes. The unit takes approximately two
hours to adjust to such changes.
4. Keep water and chemicals off the scale. Wipe with a damp cloth
from time to time.
5.
Do not use or store near heat sources(ovens, heaters, etc.).
6. When not used for a long time, remove the batteries and store
the unit in a dry, dust-free location.
7. Check and replace batteries before sending the unit for repair. If
repair is necessary, remove the batteries, repack the unit in the
original carton and protect with packing materials before
shipment.
8. Do not leave objects on the weighing tray when the scale is not
in use.
CAUTIONS
GB/USA
![](/html/af/af22/af22425bd87c92619f1e62ea69554bfab5455c67fd14d165c0ba194741d23498/bg4.png)
Remove the battery cover and insert
2 lithium batteries (CR2032)
as shown in Fig.1.
Replace the battery cover.
(Fig.1)
Ta re Function
Automatic Power Off
Changing the Batteries
Push [ON/TARE] button.
Place a container.
Push [ON/TARE] button to subtract the weight
of the container.
Note: [ON/TARE] button operates only when the stability
mark is on.
Place the material to be weighed, only the
weight of the object will be displayed. The
total weight can be calculated by adding the
weight of the container to the weight of the
object.
If the same reading is displayed for more than 2 minutes the scale will
automatically turn off.
If the display indicates " LO ", press the [OFF] button and change both
batteries at same time.
04
GB/USA
Instruction For Use
Level gauge
Adjust the level by rotating
the adjustable feet.
Push [ON/TARE] button.
Note: When you use a container (Gem cup etc.), please
use after turning on a power supply, putting a
container on the weighing tray and carrying out the
tare function.
Approximately 2 seconds later, weighing can
be performed.
Place the object to be weighed.
The display will indicate the weight of the object.
Push [OFF] button to turn off.
03
For accurate measurement, place the unit on as flat a surface as possible and
adjust the level with the adjustable feet so the bubble in the level gauge is in
the center of the frame.
GB/USA
![](/html/af/af22/af22425bd87c92619f1e62ea69554bfab5455c67fd14d165c0ba194741d23498/bg5.png)
GB/USA
Model AP-101
Measurement System
Strain gauge Load cell
Weight
Measurement
Capacity/Graduation 120g / 0.1g
Class Ⅲ
Output Item Display 120g / 0.1g increments
Display
29mm×13mm (1.14×0.51in)
Size
Product
160mm×80mm×24mm (6.30×3.15×0.94in)
Display
4Digits LCD
Height of numerals 10mm (0.39in)
Power source lithium battery
Temperature range of usage
+
5
℃
/+35℃(41°F/95°F)
Weight of equipment 160g (5.644oz) [included battery]
Rated power
DC6.0V [2×CR2032 included]
06
This device features radio interference
suppression in compilance with valid EC
Regulation 89/336/EEC.
Specifications
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules and
Canadian ICES-003. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
●Reorient or relocate the receiving antenna.
●Increase the separation between the equipment and
receiver.
●Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
●Consult the dealer or an experienced radio or television
technician for help.
Federal Communications
Commission and Canadian
ICES Notice
Modifications
The FCC requires the user to be notified that any changes or modifications
made to this device that are not expressly approved by Tanita Corporation
may void the user's authority to operate the equipment.
05
GB/USA