Summit FFAR25L7BI, SCR1006, FF31L7BICSS, SCR114L, FFAR25L7SS User Manual

...
0 (0)

SAFETY DATA SHEET

R600a (ISOBUTANE)

1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Product name

R600a, Isobutane

Synonyms

Isobutane, 2-methylpropane, trimethylmethane.

Chemical Formula

C4H10

CAS No

75-28-5

Use of Substance

Industrial uses as refrigerant.

 

Perform risk assessment prior to use.

Manufacturer

Juhua Group Corporation

 

No. 849 Jiangcheng Rd, Hangzhou, Zhejiang Province, 310009

Contact Number

+86-570-3098687

Emergency Phone Number (24 hr)

+86-570-3097819

SDS Reference Number

SDS-045-R600a

Page 1 of 15

Summit FFAR25L7BI, SCR1006, FF31L7BICSS, SCR114L, FFAR25L7SS User Manual

2. HAZARDS IDENTIFICATION

 

Chemical

 

 

Classification

 

 

 

Labeling

 

 

 

Name

CAS No.

 

Code

 

 

 

 

 

 

 

 

 

 

 

 

 

H-code

Signal Word

 

Hazard Pictogram

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R600

 

 

Press. Gas

 

H 280

Danger

 

 

 

 

75-28-5

 

 

 

 

 

 

 

 

 

Flam. Gas 1

 

H 220

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Classification of the substance

Flam. Gas I

:

Flammable gases category I

 

 

 

 

 

 

Press. Gas

:

Gases under pressure

 

 

 

 

 

 

 

 

 

(Liquefied gas)

 

 

Hazard Statement

H 220

:

Extremely flammable gas

 

 

 

 

 

 

H 280

:

Contains gas under pressure; may explode if heated.

 

 

 

 

OSHA -

:

May displace oxygen and cause rapid suffocation.

 

 

 

 

H01

 

 

 

 

 

 

 

 

 

 

CGA –

:

May cause frostbite.

 

 

 

 

 

 

HG01

 

 

 

 

 

 

 

 

 

 

CGA –

:

May form explosive mixtures with air.

 

 

 

 

HG04

 

 

 

 

 

 

Precautionary Statement

P 202

 

Do not handle until all safety precautions have been read and

 

 

 

 

 

 

 

understood.

 

 

 

 

 

 

P 210

: Keeps away from heat/ sparks/ open flames/ hot surfaces –

 

 

 

 

 

 

 

No smoking.

 

 

 

 

 

 

P 271 + P

: Use only outdoors or in a well-ventilated area. Store in a

 

 

 

 

403

 

 

well-ventilated place.

 

 

 

 

 

 

P 377

: Leaking gas fire: Do not extinguish, unless leak can be

 

 

 

 

 

 

 

stopped safely.

 

 

Page 2 of 15

 

P 381

: Eliminate all ignition sources if safe to do so.

 

P 304, P

:

IF INHALED: Remove victim to fresh air and keep at rest in

 

340, P 313

 

 

a position comfortable for breathing. Get medical advice

 

 

 

 

/attention.

 

P 302, P

:

IF ON SKIN: Thaw frosted parts with lukewarm water. Do

 

336, P 315

 

 

not rub affected area. Get immediate medical

 

 

 

 

advice/attention.

 

CGA-PG02 : Protect from sunlight when ambient temperature exceeds 52

 

 

 

 

oC (125oF).

 

CGA-PG05 : Use a back flow preventive device in the piping.

 

CGA-PG06 : Close valve after each use and when empty.

 

CGA-PG11 :

 

Never put cylinders into unventilated areas of passenger

 

 

 

 

vehicles.

 

CGA-PG12 :

 

Do not open valve until connected to equipment prepared for

 

 

 

 

use.

 

CGA-PG27

: Read and follow the Safety Data Sheet (SDS) before use.

 

OSHA-

: DO NOT REMOVE THIS PRODUCT LABEL (or

 

PG01

 

 

equivalent wording).

Other Hazards

Contact with liquid or cold vapor can cause frostbite.

Classification of the substance

Press. Gas

:

 

Gases under pressure

 

 

 

 

(Liquefied gas)

 

Flam. Gas1

 

:

Flammable gases category 1

Hazard Statement

H 220

:

 

Extremely flammable gas

 

H 280

:

 

Contains gas under pressure; may explode if heated.

Page 3 of 15

Precautionary Statement

P210

: Keeps away from heat/ sparks/ open flames/ hot surfaces

 

 

– No smoking.

 

P377

: Leaking gas fire: Do not extinguish, unless leak can be

 

 

stopped safely.

 

P381

: Eliminate all ignition sources if safe to do so.

 

P403

: Store in a well-ventilated place

 

Contact with liquid or cold vapor can cause frostbite.

 

Forms explosive mixture with air and oxidizing agents.

Other Hazards

3. COMPOSITION/INFORMATION ON INGREDIENTS

Common Name

Ingredient

CAS Number

Specification

OSHA-PEL

TLV-ACGIH

 

 

 

 

 

 

 

R600a

Isobutane

75-28-5

100% (w/w)

None established.

1000 ppm

 

 

 

 

 

 

*Contains no other components or impurities which influence the classification of the product.

4. FIRST AID MEASURES

Eye Contact

Contact with liquid or cold vapor can cause frostbite.

 

Immediately flush with water for at least 15 minutes, opening

 

eyelids to ensure flushing.

 

Get medical attention if symptoms occur.

Page 4 of 15

Inhalation

Victims should be assisted to an uncontaminated area is most

 

important.

 

Move exposed person to fresh air.

 

If not breathing, provide artificial respiration or oxygen by

 

trained personnel.

 

In the event of cardiac arrest apply external cardiac massage.

 

Further treatment should be symptomatic and supportive.

 

Keep victim warm and quiet.

 

PROMPT MEDICAL ATTENTION IS MANDAROTY IN

 

ALL CASES OF OVEREXPOSURE.

 

RESCUE PERSONNEL SHOULD BE EQUIPPED WITH

 

SELF-CONTAINED BREATHING APPARATUS.

Skin Contact

Take off the contaminated clothing / shoes immediately.

 

Flush the affected area with lukewarm water not exceeds 105oF

 

(40oC) immediately.

 

Do not use hot water.

 

If warm water is not available, gently wrap affected parts in

 

blankets.

 

Get medical attention if symptoms occur.

Ingestion

Unlikely route of exposure.

 

Do not include vomiting.

 

Get medical attention if symptoms occur.

Most important symptoms and effects,

High concentrations may cause asphyxiation.

both acute and delayed

Symptoms may include loss of mobility/ consciousness.

 

Victim may not be aware of asphyxiation.

 

As asphyxiation progresses, nausea, vomiting, prostration, and

 

loss of consciousness may result, eventually leading to

 

convulsions, coma, and death.

 

Contact with liquefied gas may cause frostbite.

Page 5 of 15

Loading...
+ 10 hidden pages