P/N783101Junction Box - All Brass -1/2 in. ports (3)
783102Junction Box - All Brass -3/4 in. ports (3)
783103Junction Box - All Brass 3/4 in. x 1 in. x 3/4 in. ports
783105Junction Box - Polycarbonate Cover Brass Base 1/2 in. ports
783106Junction Box - Polycarbonate Cover Brass Base 3/4 in. ports
783107Junction Box - Polycarbonate Cover Brass Base 3/4 in. x 1 in. x 3/4 in. ports
Instructions For:SectionMinimum Qualifications
Installing a Junction Box during new pool constructionILicensed or Certified Electrician
Listed
388J
Certified
LR38715
DANGER
Risk of Electrical Shock or Electrocution.
This fixture must be installed by a licensed or certified electrician in accordance with the National
Electrical Code and all applicable local codes and ordinances. Improper installation will create an
electrical hazard which could result in death or serious injury to pool users, installer, or others due to
electrical shock, and may also cause damage to property. Read and follow the specific instructions below.
WARNING
Before installing this product, read and follow all warning notices and instructions accompanying this Junction
Box. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage.
Call (800) 831-7133, for additional free copies of these instructions.
Important Notice
Attention Installer.
This manual contains important information about the installation, operation and safe use of this
product. This information should be given to the owner/operator of this equipment.
Pentair Water Pool and Spa, Inc.
1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000
Visit us on the Internet at: www.pentairpool.com or www.staritepool.com
Rev. D • Rev. D • Rév. D 6-26-061P/N • Núm/Pte. • Réf. 98743900
Section I.Installing a Junction Box during new pool construction.
.
.
.
.
A. THE FOLLOWING PREPARATORY STEPS MUST BE COMPLETED BY THE ELECTRICIAN BEFORE LIGHT IS INSTALLED;
SEE FIGURE 1.
1.Ensure that the electrical system of your pool conforms with all requirements of the National Electrical Code (NEC), and all
local codes and ordinances. A licensed or certified electrician must install the electrical system to meet or exceed those
requirements before the Junction Box is installed. Some of the NEC requirements are listed below.
a.The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI), and has an appropriately rated circuit breaker.
b.The Junction Box must be located at least 8 inches above water level and 4 inches above ground level. The Junction Box
should also be located at least 48 inches from the edge of the pool; see Figure 1.
c.The light fixture and all metal items within five (5) feet of the pool must be properly electrically bonded.
d.The Junction Box must be properly electrically bonded and grounded.
NOTE
The pool or spa electrical system can be verified with a Pool and Spa Electrical Qualification Test Kit. The test kit is available
from Pentair Water Pool and Spa. The electrical system inspection using the above kit must be performed by trained and certified
personnel.
2.To be certain that the pool’s electrical system meets all applicable requirements, the electrician should also consult the local
building department.
3.Position Junction Box to meet National Electrical Code requirements and to prevent hazard to personnel.
4.The center conduit hub is provided with a strain relief for a cord size up to a 10/3 AWG cord. Use underwater lights with water
resistant cord only.
5.Three equipment grounding terminals are provided for internal grounding suitable for #16 AWG to #10 AWG wire.
One pressure wire grounding terminal is provided for a #8 AWG insulated copper bonding wire.
6.Install the Junction Box gasket between the Junction Box base and cover. Replace gasket if worn or damaged (P/N 79300600).
7.Plug any unused conduit hubs with the conduit plugs provided.
48" min.
To GFCI, Circuit
Breaker and
Power Source.
Rigid
Conduit
#8 AWG Ground
Connector bonded
to rebar.
4" min.
8" min. from bottom of
Junction Box or low Voltage
Transformer to Water Line.
18" min. from Water Line
to top of Lens.
Pilot Screw at Top.
Coil 4 (four) feet of light
Figure 1.
cable around fixture.
SAVE THESE INSTRUCTIONS.
P/N • Núm/Pte. • Réf. 987439002Rev. D • Rev. D • Rév. D 6-26-06
Procedimientos operatives para la caja de empalmes JB 750
INSTRUCTIVOS IMPORTANTES DE SEGURIDAD
LEA Y SIGA TODAS LOS INSTRUCTIVOS
PROTEJA ESTOS INSTRUCTIVOS
Núm./Pte783101Caja de empalmes - totalmente de latón de 13 mm (1/2 pulg)
783102Caja de empalmes - totalmente de latón de 19 mm (3/4 pulg)
783103Caja de empalmes - totalmente de latón de 19 x 25 x 19 mm (3/4 x I x 3/4 pulg)
783105Caja de empalmes - Tapa de Polycarbonate y base de latón de 13 mm (1/2 pulg)
783106Caja de empalmes - Tapa de Polycarbonate y base de latón de 19 mm (3/4 pulg)
783107Caja de empalmes - Tapa de Polycarbonate y base de latón de 19 x 25 x 19 mm (3/4 x 1 x 3/4 pulg)
Instructivos para: SecciónRequisitos mínimos
Instalación de una caja de empalmes durante1.Electricista con licencia
la construcción de una piscina nueva.o certificación
PELIGRO
RIESGO DE CHOQUE ELÉCTRICO O ELECTROCUCIÓN
Esta caja de empalmes tiene que instalarse por un electricista con licencia o certificación y de acuerdo
con el Código Eléctrico Nacional (EE. UU.) y todos los códigos y reglamentos locales respectivos. La
instalación inadecuada creará un riesgo eléctrico que podría resultar en la muerte o en lesiones graves
a los usuarios de la piscina, a los instaladores o a otras personas debido a un choque eléctrico, y también
podría causar daños a la propiedad. Lea y siga los instructivos específicos abajo.
Sección I. Instalación de una caja de empalmes durante la construcción de una piscina nueva.
A. LOS SIGUIENTES PASOS DE PREPARACIÓN TIENE QUE HABERSE COMPLETADO POR EL ELECTRICISTA ANTES
DE INSTALAR LAS LUCES, VEA LA FIGURA 1.
1.Cerciórese de que el sistema eléctrico de su piscina cumpla con todos los requisites del Código Eléctrico Nacional
(NEC), y todos los códigos y reglamentos locales. Un electricista con licencia o certificación tiene que ser la persona
que instale el sistema eléctrico el cual deberd cumplir o exceder dichos requisites antes de instalar la caja de
empalmes. Algunos de los requisites del NEC aparecen en la lista de abajo.
ADVERTENCIA
Antes de instalar este caja de empalmes de Pentair Water Pool and Spa, lea y siga todos los avisos de advertencia y los
instructivos que acompañan al filtro. El no apegarse a los avisos de seguridad y a los instructivos podría dar por
resultado una lesión grave, la muerte o daños a la propiedad. Comuníquese con su proveedor local para obtener
ejemplares gratuitos de estos instructivos, o llame a Pentair Water Pool and Spa al (805) 553-5000.
Aviso importante
A la atención del instalador(a):
Este manual contiene información importante sobre la instalación, operacion y uso en forma segura
de este producto. Esta información debe dársele al dueño(a)/operador(a) de este equipo.
Rev. D • Rev. D • Rév. D 6-26-063P/N • Núm/Pte. • Réf. 98743900
Loading...
+ 5 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.