Sta-Rite IntelliComm II Installation Manual

Page 1
IntelliComm
24 VDC
9 -
®
II
Interface Adapter
(For use with IntelliFlo® and IntelliPro® pumps)
Installation and User’s Guide
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL
INSTRUCTIONS
SAVE THESE INSTRUCTIONS
IntelliComm II Interface Adapter Installation and Users Guide
Page 2
i
IMPORTANT SAFETY PRECAUTIONS
Important Notice: Attention Installer: This manual contains important
information about the installation, operation and safe use of this product. This information should be given to the owner and/or operator of this product. READ AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL
.
Before installing the IntelliComm® II Interface adapter , read
and follow all warning notices and instructions which are included. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call (800) 831-7133 for additional free copies of these instructions.
Risk of electrical shock or electrocution:
The IntelliComm II Interface adapter must be installed by a qualified electrician, according to the National Electrical Code (including article 680-22) or Canadian Electrical Code (including section 68) and local codes and ordinances. The electrician should also consult the local building department regarding local codes.
Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property.
Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death or serious injury to
serviceman, pool users or others due to electric shock.
IntelliComm® II Interface Adapter Overview ...................................................... 1
IntelliComm II Interface Adapter Connections .................................................. 2
Connecting to IntelliComm II Input Program Terminals .................................... 2
Connecting Power to IntelliComm II ................................................................. 2
Connecting IntelliComm II to IntelliFlo .............................................................. 3
Connecting to a Compool® Control System ...................................................... 4
RYA-LX Harness (P/N RYALX) Accessory ..................................................7
Connecting to a Jandy® AquaLink RS Control System .................................. 10
Connecting to a Hayward® Control System ....................................................12
Connecting to a Polaris® EOS Control System ............................................... 14
Setting up an IntelliFlo® VF Pump with IntelliComm II ..................................... 16
Mounting the IntelliComm II Interface Adapter ............................................... 20
Technical Support: (800) 831-7133
© 2009 Pentair Water Pool and Spa, Inc. All rights reserved.
1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 553-5000 • (800) 831-7133 IntelliComm®, IntelliFlo®, IntelliPro®, IntelliTouch®, EasyTouch®, SunTouch®, Compool®, and Pentair Water Pool and Spa® are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/or other countries. Hayward® and ProLogic® are registered trademarks of Hayward Industries Inc. Jandy® and AquaLink® are registered trademarks of Jandy Industries Inc. Polaris® is a registered trademark of Zodiac Pool Systems, Inc. Unless noted, names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those parties or others.
P/N 521033 - Rev C - 10/16/09
IntelliComm II Interface Adapter Installation and User’s Guide
Contents
Page 3
IntelliComm® II interface adapter kit contents
IntelliComm II Interface Adapter
Two mounting screws
Mounting tape
One Terminal Connector (RS-485 and IntelliComm II power connection)
Compool RJ12 Adapter
Four AUX cables (22 AWG)
Installation and User’s Guide (this manual)
IntelliComm II interface adapter overview
The IntelliComm II interface adapter provides automatic control of IntelliFlo® VF , IntelliFlo VS and IntelliPro® pumps. IntelliComm II is compatible with IntelliTouch®, EasyTouch®, SunTouch®, Compool®, Hayward®, Jandy® and Polaris® EOS control systems. The IntelliComm II Interface adapter provides:
Four input (9-24V DC/AC) program terminals (GPM/RPM 1, 2, 3, and 4) for connection to any available auxiliary relay, valve actuator or controlled output circuit on the automation control system circuit board. Typically, GPM/RPM 1 connects to the output Filter Pump relay terminal plug. You can also connect to the spa, pool electric heater, solar or 2-speed pump output circuit. Each of the four inputs can be used to control the IntelliFlo pump's speed or flow.
than one terminal input is active, the highest input number (GPM/RPM 4) will take priority regardless of the pump setting.
A four screw terminal connector for connection to the RS-485 IntelliFlo communication cable and power source (9-24V DC) from the automation control system circuit board.
Note: The IntelliComm II Interface adapter will always use ADDRESS 1 to communicate with the IntelliFlo pump.
Note: The IntelliComm II Interface adapter can be used with IntelliTouch EasyTouch® and SunTouch® systems, when additional pumps are required beyond the normal system capacity.
Safety Devices: All required safety devices, such as the IntelliFlo VS+ SVRS (Safety Vacuum Release System) pump, are unaffected when using the IntelliComm II.
Selecting Flow Rates (GPM) for IntelliFlo VF
The IntelliFlo VF pump can be selected to run at a specific US gallons per minute (GPM), for each external control input:
IntelliFlo VF: 15 - 130 GPM
Selecting Pump Speeds (RPM) for IntelliFlo VS+ SVRS and IntelliPro VS3050
The IntelliFlo VS+ SVRS, IntelliFlo VS 3050 and IntelliPro VS 3050 pump can be selected to run at a specific speed (RPM), for each external control input:
IntelliFlo VS+ SVRS: 1100 - 3450 RPM IntelliFlo VS 3050: 400 - 3450 RPM IntelliPro VS 3050: 400 - 3450 RPM
Note: If more
®
,
1
IntelliComm II Interface Adapter Installation and User’s Guide
Page 4
2
IntelliComm II Interface Adapter Connections
Screw terminal: Connects to the pump via a two pin 50 ft.
communication cable (P/N 350122) provided with the pump. Also connects to a 9-24VDC, 200mA power source (automa­tion control system circuit board)
Four (9 - 24V DC/AC) input
1
IntelliComm II Interface Adapter
2
3
4
Power LED on when power is applied.
Connecting to IntelliComm II Input Program Terminals
There are four (two-wire) cables provided in kit for interface connections from the automation control system circuit board, to the four IntelliComm II program (GPM / RPM) input terminal (see page 3). The input terminal cable wires are not polarized. Plugs/wires can be connected in any order.
Connecting IntelliComm II to a Valve Actuator
A Valve Actuator can be connected from the automation control system circuit board to any one of the IntelliComm II input terminals (1-4) by splicing into the valve actuator cable using the provided two-wire input terminal cable (see page 3).
Connecting Power (9-24 VDC) to IntelliComm II
Power to the IntelliComm II requires a 9-24VDC, 200mA power source, which can be supplied from the automation control system circuit board or an AC to DC power adapter. For VDC power connection on Compool, Jandy and Hayward control systems, see pages 4 - 13.
IntelliFlo pump AC connection
If multiple pump speeds are required, the IntelliFlo pump must be wired to a circuit breaker not to a relay.
Note: If the IntelliFlo pump is used in a commercial application or connected to an Emergency Shut-Off switch, the pump must be connected to a relay for proper Emergency Shut-Off operation.
Salt Chlorine System Connections
All Salt Chlorine Generator (SCG) units must be connected to the Filter Pump relay output. If the Filter Pump relay output is being used for the IntelliComm II, then a RYALX can be used if a SCG is present in the system. For more information about using the RYALX see page 7.
terminals (GPM / RPM 1, 2, 3, 4):
Each input terminal connects to an output relay or valve terminal on the automation control system circuit board via a two-pin AUX cable.
LED on when power (9-24V DC) is received from automation system.
IntelliComm II Interface Adapter Installation and User’s Guide
Page 5
Connecting IntelliComm II to IntelliFlo
TO OPERATE THE INTELLIBRITE COLOR LIGHT SHOWS
Connection from IntelliComm II to an IntelliFlo VF or IntelliFlo VS pump is via a 50 ft. RS-485 communication cable (P/N 350122), which is provided with the pump.
Connecting the IntelliFlo Pump to IntelliComm II RS-485 Terminal
Connect the YELLOW and GREEN wire from the IntelliFlo communication cable to the YELLOW and GREEN RS-485 screw terminals on the IntelliComm II interface adapter as shown below.
Note: Connect GPM/RPM 1, 2, 3, and 4 to any
control output or auxiliary relay circuit (RELAY 1-4) on the automation circuit board. Typically, GPM/RPM 1 connects to Filter Pump.
If more than one terminal input is active, the highest input number (GPM/RPM 4) will take priority regardless of the pump setting.
RS-485 COMMUNICATION CABLE (22 AWG)
9 - 24 VDC
RED
PWR
YLW GRN
BLK
GND
3
Note: The black wire must be used. Choosing either the Red or White wire will depend on the direction that the actuator needs to rotate to the spa.
YLW
RED
PWR
GPM/RPM 1
(PROGRAM 1)
GPM/RPM 2
(PROGRAM 2)
GPM/RPM 3
(PROGRAM 3)
GPM/RPM 4
(PROGRAM 4)
9 - 24V DC/AC
RED
BLK
GRN
GND
Pentair Water Pool and Spa
Automation Control Board
(used with SunTouch, EasyTouch
RELAY 1 RELAY 2 RELAY 3 RELAY 4
VLV A
VLV B
WHITE
or
VLV A
Automation Circuit Board
IntelliComm II
IntelliComm II to IntelliFlo Pump and Pentair Water Pool and Spa
Automation Control Circuit Board Connection Diagram
IntelliComm II Interface Adapter Installation and User’s Guide
BLK
INTAKE
RTRN
and IntelliTouch)
9 - 24V DC/AC
Page 6
4
Connecting to a Compool® Control System
Connection from IntelliComm II to a Compool control system utilizes the RJ12 adapter (provided in the kit), and the IntelliFlo RS-485 communication cable (provided with the pump).
Compool Models Compatible with IntelliComm II (see page 6 and 7)
Compool CP-3xxx series, CP-2000 and Time Master, CP-1000, CP-2020, Swim Master LX-20, LX-42, CP-2020, LX-100, LX-80 Commercial and CP-100 control systems. Note: IntelliComm II does not support the LX-820 Commercial system.
Compool Models Compatible with IntelliComm II (Using an External 9 VDC 200mA AC Power Adapter)
The following Compool models are compatible with IntelliComm II using an external 9 VDC, 200mA AC power adapter: Compool CP-30, LX-220, LX-40.
Always disconnect AC POWER to the LOAD CENTER at the circuit breaker. Also, disconnect AC power to the PUMP before installing the
IntelliComm II interface adapter. Failure to do so could result in death or serious injury to the service person, pool users or others due to electric shock. Read all SAFETY PRECAUTIONS on page i before starting.
Accessing the Compool Circuit Board
The Compool control system circuit board is located in the power center. Refer to the Compool control system owner’s manual for access information.
Connecting power to the IntelliComm II from a Compool CP3xxx circuit board (see page 5 and 7)
1. Connect RJ12 adapter power wires (9-24V DC/AC): From the RJ12 adapter, connect the BLACK wire and RED wire to the RS-485 GND (BLACK) and PWR (RED) terminal respectively. NOTE: For LX-100:
Connect the YELLOW wire from RJ12 to IntelliComm II Red (PWR) screw terminal. Note: To avoid circuit board damage, DO NOT connect the RED and YELLOW wires together to Red (PWR) terminal, leave RED UNCONNECTED (see page 6).
2. Connect RJ12 adapter cable plug to the Compool COM PORT: Disconnect the Compool control panel RJ12 plug from the Compool circuit board COM Port and connect it to the RJ12 adapter (provided). Connect the RJ12 adapter plug into the COM Port (use black plug for LX-100) on the Compool circuit board (see page 5).
3. Connecting AUX cables: Choose the functions you wish to control on the Compool system. Connect the auxiliary cables (provided in kit) from the IntelliComm II input terminals (GPM/RPM 1, 2, 3, 4) to the auxiliary connector on the Compool circuit board. Typically, GPM/RPM 1 input terminal, connects to Compool FILTER PUMP output terminal. Choose the other functions on the Compool board and connect them to GPM/RPM 2, 3, and 4 input terminals.
4. Connecting IntelliComm II to IntelliFlo: For IntelliComm II to IntelliFlo wiring information, see page 3.
6. Mounting the IntelliComm II (see page 20).
7. Setting up IntelliFlo speeds and flow rates (see page 16).
IntelliComm II Interface Adapter Installation and User’s Guide
Page 7
Note: Using a RYALX Harness (for Compool CP-38xx Systems): For the Compool SOLAR system, connect the
RYALX harness cable plug to the SOLAR socket, then connect the IntelliComm II pump speed plug and the VALVE cable plug to the RYALX board. The RYALX can be used for any output.
Note: The Spa output plug on the Compool circuit board can be used for direct IntelliComm II connection, instead of splicing into the valve output cable.
1810 24
SPA FLTR
AUX VLV
POOL FLTR
AUX1
AUX2
AUX3
AUX4
AUX5
AUX6
B/W
DIM3DIM4
SPA EHTR
SPA
SPA 2SPD
SOL POOL
FLR CLN
EHTR POOL
POOL
SOL
2SPD
CHOOSE FUNCTION
(for connection to IntelliComm II)
PART# PC-LX3830COMPOOL 11010B
AUX VLV CNTRL
CAUTION: DO NOT SHORT PINS OF RELAY SOCKETS
5
GND
RED
BLK
HLMP
HBST
ON
12345
SPA
YLW
ON
12345
67
8
SFLT
PFLT
AUX1
AUX2
AUX3
AUX4
AUX5
AUX6
FDEL
FREEZE I/L SYST
POOL
REM1
REM2
REM3
REM4
REM5
TO COM PORT
RJ12 Adapter Wiring Diagram
CLNR
MANHT
REM6
SSOL
67
SHPMP
ON
12345
8
PSOL
PHPMP
FLRCL
DIM3
SPC FNCT
PHONE CONTROLS
SPA
PHONE
GAS HEATERS
POOL SPA
GRN
RED
SPA SOL
GRN
RED
SPA WTRPOOL WTR
GRN
RED
POOL SOL
TEMPERATURE SENSORS
GRN
RED
67
8
GRN
DIM4
B/W
SHEAT
SAUX2
PHEAT
PAUX1
HI SPD
FREEZE
SENSOR
HEAT
POOL
COM PORT
RED
COM PORT
BLK
BLK GRN YLW
RED
RS485
GND
PWR
PRGM 3
PRGM 2
PRGM 1
9 - 24V DC/AC
PRGM 4
RED
RS-485
RJ12
ADAPTER
PIN 3 (GRN)
PIN 2 (YLW)
TO PUMP
TO CONTROL
PANEL
IntelliFlo pump
CP3xxx
IntelliComm II Interface Adapter Installation and User’s Guide
Page 8
6
Connecting power to the IntelliComm II from a Compool LX100 circuit board
Note: Use a RYALX Harness (P/N RYALX) If
the circuit board relay output is in use and the IntelliComm II AUX cable needs to share the socket output.
FLTR TIMER
CLNR TIMER
24
AUX VLV
CONTROLLED BY
YES
NO
SILVER
12
+15
18 0
YRG
INT VLV
RET VLV
AUX VLV
SPA
FLTR
CLNR
AUX1
AUX2
CLNR
AUX3
AUX 3
EHTR
COM PORT
RJ12
ADAPTER
CHOOSE FUNCTION
RELAY CONNECTIONS
DO NOT SHORT THESE PINS
(for connection to IntelliComm II)
BLK
RED NOT CONNECTED
LX-100 ONLY (YLW)
Only connect YELLOW wire for LX-100. Do not connect red and yellow wires together.
BLK GRN YLW
RED
RS485
GND
PWR
RS-485
PIN 3 (GRN) PIN 2 (YLW)
TO PUMP
PRGM 2
PRGM 1
9 - 24 VDC
PRGM 4
PRGM 3
IntelliFlo pump
MOTOR SWITCH
MOTOR SWITCH
REMOTE SWITCHES
GND
GAS HTR
C
S
AUX1
SPA
AUX3
AUX2
SLMP
(LX100 use black plug)
RED
BLK
YLW
WTRFL
ON
12
AUX1
DELAY
JP16 JP17
TEMP
SENSOR
GRN RED
P
TO COM PORT
RJ12 Adapter Wiring Diagram
LX100 Motherboard
IntelliComm II Interface Adapter Installation and User’s Guide
Page 9
RYALX Harness (P/N RYALX) Accessory (For use with Compool CP-38xx Systems)
The RYALX harness (y-adapter) allows any one output circuit to operate two relay circuits. For example, to free up an additional connection on the Compool SOLAR system, connect the RYALX harness cable plug to the SOLAR socket, then connect the IntelliComm II pump speed plug and the VALVE cable plug to the RYALX board. The RYALX can be used for any output.
The example connection diagram below shows how to share the Aux Valve Control using solar. The signal to tell solar to turn on, comes from the solar socket located below the HTR socket. Then the AUX VLV control and the speed of the pump now responds to that signal.
7
RYALX Circuit board
AUX VLV CNTRL
RYA-LX
COMPOOL
PART# PC-LX3830COMPOOL 11010B
CAUTION: DO NOT SHORT PINS OF RELAY SOCKETS
ON
ON
12345
67
REM3
8
8
AUX5
AUX6
FDEL
CLNR
MANHT
SSOL
SHPMP
PSOL
PHPMP
FLRCL
PHONE CONTROLS
SPA
REM4
REM5
REM6
PHONE
AUX3
REM2
67
AUX4
TO COM PORT
GND
HLMP
12345
SFLT
PFLT
AUX1
AUX2
FREEZE I/L SYST
HBST
SPA
POOL
REM1
1810 24
SPA 2SPD
POOL 2SPD
ON
12345
67
DIM3
DIM4
B/W
SHEAT
SAUX2
SPC FNCT
HI SPD
HEAT
POOL
COM PORT
RJ12
ADAPTER
AUX VLV
DIM3DIM4
FLR CLN
GAS HEATERS
POOL SPA
GRN
RED
SPA SOL
GRN
RED
SPA WTRPOOL WTR
GRN
RED
POOL SOL
TEMPERATURE SENSORS
GRN
RED
8
GRN
PHEAT
PAUX1
FREEZE
SENSOR
RED
COM PORT
SPA FLTR
POOL FLTR
AUX1
AUX2
AUX3
AUX4
AUX5
AUX6
B/W
SPA EHTR SPA SOL POOL EHTR POOL SOL
BLK
AUX VLV
CHOOSE FUNCTION
(for connection to IntelliComm II)
SOLAR PUMP
RS485
GND
BLK GRN YLW
PWR
RED
RED
RS-485
PIN 3 (GRN) PIN 2 (YLW)
TO PUMP
TO CONTROL
PANEL
This output is used for both the 3-way valve and a solar booster pump if required.
PRGM 4
PRGM 3
PRGM 2
PRGM 1
9 - 24V DC/AC
IntelliFlo pump
CP-38xx Motherboard
IntelliComm II Interface Adapter Installation and User’s Guide
Page 10
8
Connecting Power to IntelliComm II from Compool Circuit Board
To power the IntelliComm II requires a two wire connection from the Compool circuit board to the IntelliComm II circuit board (as shown below). For Compool to IntelliComm II auxiliary cable connection information, see Connecting AUX
cables, on page 4.
9 - 24V DC/AC
PRGM 4
PRGM 3
PRGM 2
Connect to Compool circuit board (see page 4)
PWR
PRGM 1
GND
Choose the function on the Compool circuit board
Always disconnect AC power to the LOAD CENTER at the circuit breaker. Also, disconnect AC power to the PUMP before installing the
IntelliComm II interface adapter. Failure to do so could result in death or serious injury to the service person, pool users or others due to electric shock. Read all SAFETY PRECAUTIONS on page i before starting.
BLACK (GND)
RED (9-24V DC) YLW
GRN
BLK (GND)
To IntelliFlo pump
From Compool circuit board
From Compool circuit board
RED (24 VDC)
LX-42
IntelliComm II Interface Adapter Installation and User’s Guide
Page 11
CP1000
RED (24 VDC) BLACK (GND)
RED (24 VDC)
BLACK (GND)
9
BLACK
(GND)
RED (24 VDC)
Swim Master (LX20)
CP2020
RED (24 VDC)
CP2000 and Time Master (LX10)
IntelliComm II Interface Adapter Installation and User’s Guide
BLACK (GND)
BLACK (GND)
RED (24 VDC)
SP100 (LX36)
Page 12
10
Connecting to a Jandy® AquaLink® RS Control System
Always disconnect AC power to the LOAD CENTER at the circuit breaker. Also, disconnect AC power to the PUMP before installing the
IntelliComm II interface adapter. Failure to do so could result in death or serious injury to the service person, pool users or others due to electric shock. Read all SAFETY PRECAUTIONS on page i before starting.
Access Jandy control system circuit board
The Jandy control system circuit board is located in the load center. Refer to the Jandy control system owner’s manual for access information.
Connect power to the IntelliComm II (9-24 VDC) from Jandy circuit board
1. Connect the GREEN (-) wire and the RED (+) wire from the Jandy RS-485 screw terminal, to the GND and PWR terminal respectively, on the IntelliComm II RS-485 screw terminal (see page 8).
Connect AUX cables
2. Connect the auxiliary cables (provided in kit) from the IntelliComm II input terminals GPM/RPM 1, 2, 3, and 4 to any control output or auxiliary relay circuit on the Jandy circuit board. Typically, GPM/RPM 1 connects to the output Filter Pump relay terminal plug. However, Jandy auxiliary relay circuits can be connected to any of the four input terminals for custom pump speed control.
terminal input is active, the highest input number (GPM/RPM 4) will take priority regardless of the pump setting.
NOTE: If more than one
3. Connect IntelliComm II to IntelliFlo For IntelliComm II to IntelliFlo wiring information, see page 3.
4. Mounting the IntelliComm II (see page 20).
5. Setting up IntelliFlo speeds and flow rates (see page 16).
IntelliComm II Interface Adapter Installation and User’s Guide
Page 13
t
Note: The Spa output plug on the Jandy circuit board can be used for direct IntelliComm II connection, instead of splicing into the valve output cable.
230 VAC power
to pump
11
PRGM 2
PRGM 1
PWR
RED
YLW
9 - 24V DC/AC
PRGM 4
PRGM 3
GRN
GND
BLK
CHOOSE FUNCTION
(for connection to IntelliComm II)
9-24V DC/AC
RELAY 1
RELAY 2
RELAY 3
RELAY 4
JANDY RS circuit board auxiliary connections
Note: Connect GPM/RPM 1,
2, 3, and 4 to any control output or auxiliary relay circuit (RELAY 1-4) on the Jandy circuit board. Typically, GPM/RPM 1 connects to Filter Pump.
If more than one terminal input is active, the highest input number (GPM/RPM 4) will take priority regardless of the pump setting.
RS485
YLW GRN
9 - 24 VDC
GND
BLK
YEL
GRN
4321
Jandy RS Power Center
RS-485 COMMUNICATION CABLE (22 AWG)
IntelliComm II (mounted inside low voltage compartmen of Power Center)
RED
Red Terminal Bar
654321
10987654321
4321
4321
RS6 & RS8 ONLY
RS8 ONLY
RESET
S1
P
AUTO
UX 1
ER PUM
AU
A
T
FIL
SERVICE
TIME OUT
S2
POOL MODE
7
4
2
SPA MODE
X
X
X 5
UX 6
UX 3
UX
U
A
A
A
AU
A
SPA DRAIN
SOLAR
HEATER
SPA FILL
IntelliComm II to Jandy AquaLink Control System Connection Diagram
IntelliComm II Interface Adapter Installation and User’s Guide
Page 14
12
Connecting to a Hayward® Pro Logic® Control System
The following describes how to connect IntelliComm II to a Hayward Pro Logic series control system (see page 13 for connection diagram).
Always disconnect AC power to the LOAD CENTER at the circuit breaker and disconnect AC power to the PUMP before installing the
IntelliComm II interface adapter. Failure to do so could result in death or serious injury to the service person, pool users or others due to electric shock. Read all SAFETY PRECAUTIONS on page i before starting.
Access the Hayward Pro Logic Circuit Board
The Hayward control system circuit board is located in the load center. Refer to the Hayward control system owner’s manual for access information.
Connect power to the IntelliComm II (9-24V DC) from Hayward Circuit Board
1. Connect the GREEN (-) wire and the RED (+) wire from the Hayward screw terminal (RS-485), to the GND and PWR terminal respectively, on the IntelliComm II RS-485 screw terminal (see page 13).
Connect AUX cables (Disconnect AC power to the PUMP and Controller)
2. Cut one plug off each of the provided four auxiliary cables. Strip back the ends of the wires.
3. Remove the relay bracket(s) to access relays: In the Hayward load center, remove the two screws securing the upper and lower relay bracket and remove the brackets.
4. Attach wires to the FILTER PUMP relay screws terminals: Loosen the two top relay terminal screws with attached wires. Using the provided auxiliary cable (see step 1), carefully wrap the ends of each wire under the screw terminals. Tighten the screws to secure the wires in place. Wires are not polarized; connect wires to either relay terminal.
5. Repeat Step 3: Splice the cable wires into any control output or auxiliary circuit relay terminals on the Hayward circuit board.
6. Reinstall the relay bracket(s) in the load center and secure with the retaining screws.
®
7. Connect IntelliComm II to IntelliFlo For IntelliComm II to IntelliFlo wiring information, see page 3.
8. Mounting the IntelliComm II (see page 20).
9. Setting up IntelliFlo speeds and flow rates (see page 16).
IntelliComm II Interface Adapter Installation and User’s Guide
Page 15
9 - 24V DC/AC
13
9 - 24 VDC
IntelliComm II to Hayward Pro Logic Control System Connection Diagram
IntelliComm II Interface Adapter Installation and User’s Guide
Page 16
14
Connecting to a Polaris® EOS Control System
The following describes how to connect IntelliComm II to a Polaris® EOS control system (see page 15 for connection diagram).
Connecting Power to IntelliComm II from Polaris Circuit Board
To power the IntelliComm II requires a two wire connection from the Polaris circuit board to the IntelliComm II circuit board (as shown on page 15).
Always disconnect AC power to the LOAD CENTER at the circuit breaker and disconnect AC power to the PUMP before installing the
IntelliComm II interface adapter. Failure to do so could result in death or serious injury to the service person, pool users or others due to electric shock. Read all SAFETY PRECAUTIONS on page i before starting.
Access the Polaris Circuit Board
The Polaris control system circuit board is located in the load center. Refer to the Polaris EOS control system owner’s manual for access information.
Connect power to the IntelliComm II (9-24 VDC) from Polaris circuit board
1. Connect the GREEN (-) wire and the RED (+) wire from the Polaris 24 VDC output screw terminal, to the GND and PWR terminal respectively, on the IntelliComm II RS-485 screw terminal (see page
15).
Connecting AUX cables
2. Connect the auxiliary cables (provided in kit) from the IntelliComm II input terminals GPM/RPM 1, 2, 3, and 4 to any control output or auxiliary relay circuit on the Polaris circuit board. Typically, GPM/RPM 1 connects to the output Filter Pump relay terminal plug (HP4). However, Polaris auxiliary relay circuits (HP1 - HP6) can be connected to any of the four input terminals for custom pump speed control.
than one terminal input is active, the highest input number (GPM/ RPM 4) will take priority regardless of the pump setting.
NOTE: If more
3. Connect IntelliComm II to IntelliFlo For IntelliComm II to IntelliFlo wiring information, see page 3.
4. Mounting the IntelliComm II (see page 20).
5. Setting up IntelliFlo speeds and flow rates (see page 16).
IntelliComm II Interface Adapter Installation and User’s Guide
Page 17
24 VDC (To power IntelliComm II)
15
From 24 VDC to RED (PWR) and BLK (GND) on IntelliComm II board
9 - 24V DC/AC
RELAY4
RELAY3
RELAY2
Connect to Polaris circuit board
Choose the function on the Polaris circuit board (HP1-HP8, VLV1 -VLV 6)
PWR
RELAY1
GND
RED (9-24 VDC) YLW
GRN
BLK (GND)
To IntelliFlo pump
From Polaris circuit board
From Polaris circuit board
Polaris EOS Control System Load Center
IntelliComm II Interface Adapter Installation and User’s Guide
Page 18
16
Setting up an IntelliFlo VF Pump with IntelliComm II
The IntelliFlo VF pump can operate with all of its stand alone features if desired. For example the pump can run filter cycles, egg timer features 1 and 2 and time of day scheduling of features 3-9. If IntelliComm II sends the pump a command when the pump is running the filter cycle or features 3-9, the IntelliComm II command takes priority regardless of flow rate. IntelliComm II will not interrupt
nor take priority over Features 1 or 2.
For the IntelliFlo VF to accept a command from the IntelliComm II the pump must be in the “Running” mode. To place the IntelliFlo VF in “Running” mode, press the Filter mode button, then press the Start/Stop button. The led above the Start/Stop button must be lit for the IntelliFlo VF to accept commands from the IntelliComm II.
The default “Filter” cycle time in the IntelliFlo VF is from 9 AM to 9 PM. Since the IntelliFlo VF must be in the “Filter” mode, running Schedules, (LED above Start/ Stop button lit) to accept commands from IntelliComm II, it will run its default filtration schedule first. If you want the pump to only run when it receives commands from IntelliComm II, program its “Filter” mode with the same start and stop times. For example program Cycle 1 in the “Filter” menu to “Start” cycle one at 9 AM and “Stop” cycle one at 9 AM. This will cause the pump to not run its filter cycle. This is done on the IntelliFlo keypad under Menu, Filter. Address 1, is the default address for the IntelliFlo VF. The IntelliComm II will only communicate with address 1. The pump’s “Address” setting is the first menu item under “Pool Data”.
Programming Flows into the IntelliFlo VF
1. Press the Menu button.
2. Press the down arrow until Ext. Ctrl. (External Control is displayed).
3. Press the Select button to go Ext. Ctrl. (Program 1 is displayed).
4. Press the Select Button (Enabled, Activation is displayed).
5. Press the down arrow. (Program 1, 30 GPM, Set Flow, is displayed. The Program 1 flow rate will run when PRGM 1 is activated on the IntelliComm II control board.
6. To change this flow rate press the “Select” button. The flow rate can be adjusted from 15 gpm to 130 gpm.
7. The cursor will highlight the one's digit column. Press the left and right arrows to move the cursor and the up and down arrows to change the number.
8. Press the Enter Button to save.
9. Press the down arrow until “Time Delay Stop” is displayed. Time Delay Stop is used to control the pump to run the Program speed for an additional amount of time after the IntelliComm II turns off its run command. This is often used for a heater cool down.
10. Press Select to highlight the cursor, use the left and right arrows to move the cursor and the up and down arrows to change the number.
11. Press Enter to save.
12. Press Escape to Exit. The display shows Program 1. Press the down arrow to get to Program 2 and follow the same instructions to program. For more information about programming the pump, refer to the IntelliFlo VF Installation and User’s Guide (P/N 353850).
IntelliComm II Interface Adapter Installation and User’s Guide
Page 19
Setting up an IntelliFlo VS or IntelliPro VS
The IntelliFlo VS pump Speeds 1, 2, 3 and 4 correspond to Prgm (Program) 1, 2, 3 and 4 on the IntelliComm II circuit board. To program speed one on the IntelliFlo VS. Press the “Speed 1” button. Press the Start button. To increase the speed of “Speed 1” press the up arrow button. Each press of the up arrow will increase the RPM by 10 RPM increments. Pressing the down arrow will decrease the RPM by 10 RPM. When the desired speed is found, press and hold down the “Speed 1” button and the new speed will be locked in. This new speed will be the speed that the pump will run when “Prgm 1” is activated on the IntelliComm II. The speed can be adjusted from 400 RPM to 3450 RPM.
Note: If the IntelliFlo VS pump is turned on manually by pressing a Speed button and the Start button, it will run the speed that was pressed and the LED above this button will be illuminated. If it then gets a command to run a speed from the IntelliComm II, it will run the new commanded speed and the LED above the new speed will be illuminated. When the command from the IntelliComm II has stopped, the pump will go back to running the manually pressed speed.
Note: If the IntelliComm II has switched on the IntelliFlo VS and it is running a speed and you manually adjust the pump speed using the speed buttons on the pump, you must then manually switch the pump OFF, this turns off the manually manipulated speed and allows the IntelliComm II to take command and switch the pump back on to run at the commanded speed. If, after manipulating the keypad, the pump is not manually turned off by pressing the Stop button the pump will continue to run after the IntelliComm II command is stopped.
17
Unlike the VF, the IntelliFlo VS does not have to be in the “Running” mode to accept commands from an IntelliComm II. The power must be on (Green LED lit) on the IntelliComm II to accept commands.
Setting up an IntelliFlo VS+SVRS
The IntelliFlo VS+ SVRS is programmed in a similar way to the IntelliFlo VF. Speeds for each program number are set up under the menu item “Ext. Ctrl.” (External Control).
IntelliComm II Interface Adapter Installation and User’s Guide
Page 20
18
Programming IntelliFlo VS+ SVRS Speeds
Press the menu button. Press the down arrow until “Ext Ctrl.” is displayed. Follow the instructions as described on page 10 for the IntelliFlo VF (steps 1 through 12). However there is one difference. The IntelliFlo VS+SVRS does not have any default “Schedules” so it is not necessary to deactivate any schedules so it will only run commands from the IntelliComm II. But, just like the IntelliFlo VF it can be programmed to run scheduled flows and when it gets a command from IntelliComm II to run a program the IntelliComm II program will take priority.
Note: If more than one terminal input is activated on the IntelliComm II the highest number input will take priority, regardless of the pump setting. For example: If program 1 and program 3 are activated on the IntelliComm II The pump will run program 3, regardless of speed, flow or order of activa­tion.
When a command to run is sent from the IntelliComm II to the VS+SVRS the pump’s display will show “Running Prog. 1” and the countdown timer on the IntelliFlo VF display will show 00:01.
CAUTION: When performing maintenance on the system or the pump switch the power to the pump off at the circuit breaker. This will ensure that the pump does not switch on from remote operation or run a schedule.
IntelliFlo Pump Warnings and Alarm Conditions
The IntelliFlo VS-3050 alarms and warnings are indicated by flashing LEDs on the control panel. For example, if a “Drive Temperature” warning occurs, the LED will blink two times, then Off, then blink two times. This sequence is repeated until the condition is cleared.
Warning condition: If a warning condition occurs the pump will be continue to run but at a reduced speed. The Green LED executes a sequence of blinks to indicate which alarm or warning has occurred.
Alarm condition: If an alarm condition occurs the pump will drive stop running. The red LED flashes continuously to indicate the presence of an alarm. The alarm LEDs will reset when the
condition clears.
IntelliComm II Interface Adapter Installation and User’s Guide
Page 21
19
.noitalitnevrofaeraetauqeda
otdeepsrehgihatarotomnuR.3
.looco
.wolfriagniloocevorpmi
twolladnarotompotS.2
eserotrewopelcyC.1
.evirdecalpeR.2
otdeepsrehgihatarotomnuR.2
.n oitalitnevrofaeraetauqeda
egatlovylppusreporperusnE
.wolfriagniloocevorpmi
.yleerfsnipsrotomfienimreted
.daolrevofoecruo
dnarotomezigrene-eD.2
.evirdecalpeR.3
srofmetsys
.egatlovylppu
segatlovevissecxeesuacnac
.ssubCDs'evirdehtno
sreporperusnE.2
egatlovevissecxEsdeepsneewtebgnihctiwsdipaR.1
mralAnoitpircseDnoitcA
ehtemitforebmuN
knilblliwDEL
2gninraWerutarepmeTevirDerutarepmetevirdevissecxEsahnafrotomehterusnE.1
6mralAerutarepmeTevirDerutarepmetevirdevissecxEsahnafrotomehterusnE.1
5mralanwonknUeruliafcinortcelE.pmupt
8mralAtnerrucrevOtnerrucevirdevissecxElacinahcem/diulfenimaxE.1
7mralAtuOrewoPwolegatlovylppuS.
9mralAegatlovrevO ssubevirdno
Alarm (RED) and Warning (GREEN) LED sequence
IntelliComm II Interface Adapter Installation and User’s Guide
Page 22
20
Mounting the IntelliComm II Interface Adapter
The IntelliComm II Interface Adapter cover (3 in. x 2 ¾ in.) can be mounted as follows:
On the inside back wall of the low voltage compartment in a load center, using the provided adhesive mounting tape.
On a flat surface using the two mounting screws. Choose a dry covered a location within ten (10) feet from the system load center.
Mounting the IntelliComm II Interface Adapter on a flat surface
1. Remove the two cover retaining screws.
2. Carefully separate the front (label) and back cover (two screw holes) with the back support from the circuit board. Be careful not to touch the circuit board components. Hold the circuit board by the edges. Place the circuit board aside.
Drill two mounting screws holes for the back cover
3. Cut out the template on the following page.
4. Position the template on a flat surface. Mark the two screw locations for the mounting holes. Remove the template.
5. Using a ¼ in. drill bit, drill the two mounting holes.
6. Position the back cover over the two mounting screw holes. Secure the back cover with the two mounting screws.
Install the circuit board and front cover
7. Place the circuit board on the back cover standoffs.
8. While holding the circuit board, place front cover (with the back support) over the back cover. Secure the front cover with two retaining screws.
9. The installation is complete.
3.2 in.
2 ¾ in.
Front cover
retaining
screw holes
IntelliComm II (Front Cover)
IntelliComm II Interface Adapter Installation and User’s Guide
Page 23
Cut-Out
Cut-Out
IntelliComm II (Back Cover) Template
IntelliComm II Interface Adapter Installation and User’s Guide
Page 24
*521033*
P/N 521033 - Rev C
IntelliComm II Interface Adapter Installation and Users Guide
Loading...