Marley / Sigma F Series Cooling Tower / Table of Contents
Engineering Data
Schematic 4
Support 5
Piping 7
Temperature Control 10
Environmental 11
Specifications / Base
Base 12
Thermal Performance 13
Construction 14
Fan Deck and Fan Cylinder 15
Mechanical Equipment 15
Fill, Louvers and Drift Eliminators 16
Hot Water Distribution System 17
Casing 17
Access and Safety 18
Cold Water Basin 18
Scope of Work 19
Specifications / Options
Cold Water Basin Options
Stainless Steel Cold Water Basin 20
Watertight Partition between Tower Cells 20
Basin Heater 20
Convenience and Safety Options
Fiberglass Stairway 21
Wood Stairway 21
Plenum Walkway 22
Ladder Extension 22
Ladder Safety Cage 22
Hot Water Basin Covers 22
Air Inlet Screens 23
Appearance Options
Architectural Casing 23
Cased Guardrail 23
Control Options
Control System 24
Variable Speed Drive 25
Vibration Limit Switch 26
fiberglass-structure cooling tower designed
to serve normal air conditioning and refrigeration
systems as well as medium sized industrial loads.
Evolving from the crossflow concept of cooling tower
pioneered by Marley in 1938, and incorporating over
65 years of design advancements, the Sigma F Series
represents the current state of the art in this cooling
tower category.
This booklet not only relates the language to use
in describing an appropriate Sigma F Series cooling
tower—but also defines why certain items and
features are important enough to specify with the
intention of insisting upon compliance by all bidders.
The left hand column of pages 12 through 27
provides appropriate text for the various specification
paragraphs, whereas the right hand column comments
on the meaning of the subject matter and explains its
value.
Pages 12 through 19 indicate those paragraphs which
will result in the purchase of a cooling tower which
will not only accomplish the specified thermal
performance, but which will include normal operation
and maintenance-enhancing accessories and features.
It will also incorporate those standard materials which
testing and experience has proven to provide best
results in normal operating conditions.
Pages 20 through 27 provide some paragraphs
intended to add those features, components, and
materials that will customize the tower to meet the
user's requirements.
Space does not permit definition and explanation of
all of the possible options that can be applied to the
Sigma F Series. SPX Cooling Technologies realizes
that you, the purchaser, must be happy with the
tower's characteristics, and we are prepared to
provide—or provide for—any reasonable enhancement
that you are willing to define and purchase.
Your needs will become part of the continuing
improvement of this product line.
Marley / Sigma F Series Cooling Tower / Engineering Data : Schematic
H
B
TOP OF
FAN CYLINDER
BASE OF
TOWER COLUMNS
FAN DECK
13'-6"
W OUT-TO-OUT OF TOWER
A BAYS AT 4'-0" = L
C
DIAMETER FAN
3"3"
COLUMNCOLUMN
C
L
C
L
COLUMN
C
L
TOWER PLAN
4
Use this data for preliminary layouts only.
Obtain current drawing from your Marley sales
representative.
The UPDATE web-based selection software
— available at spxcooling.com — provides
Sigma F Series model recommendations based
on customer's specific design requirements.
Tower
Model
F121129'-2"16'-0"19'-6"46'-0"144"
F122131'-2"16'-0"20'-6"47'-0"168"
F123131'-2"20'-0"20'-6"57'-0"168"
F124131'-2"24'-0"20'-6"67'-0"168"
F125135'-2"24'-0"20'-6"67'-0"216"
F126135'-2"28'-0"20'-6"77'-0"216"
WLHABC
NOTE
1 Use this bulletin for preliminary layouts only. Obtain current
drawings from your Marley representative.
2 All table data is per cell.
3 All tower installations require a minimum of 4'-0" from cen-
terline of tower endwall column to any vertical obstruction at
tower ladder location. Ladder can be located at any corner of
the fan deck. Ladder extends 8
3
⁄8" below the base of tower
ENDWALL ELAVATION
Dimensions
columns on applications with a stainless steel cold water basin.
Ladder stops at top of basin curb wall on applications with a
concrete basin.
Tower installations with an elevation 20'-0" or more from the top
of the fan deck to grade or roof level require a safety cage on
the tower ladder in compliance with OSHA standards. Marley
ladder safety cages are available as an option.
Marley / Sigma F Series Cooling Tower / Engineering Data : Support
A
SPACES AT 4'-0" =
L
W
OVERALL OF BASIN
SUMP
OVERFLOW
MAKEUP
VALVE
INTERMEDIATE BEAM
AIR INLET FACE
AIR INLET FACE
CASED ENDWALL FACE
CASED ENDWALL FACE
PRIMARY SUPPORT
BEAM
2 1/4" MAX.
NORMAL
GAGE
COL. & ANCH. BOLT
C
L
5
SECTION
Tower
Model
Note 4
NOTE
1 Use this bulletin for preliminary layouts only. Do not use
F1211426'-6"16'-0"5581051510
F1221428'-6"16'-0"5930054920
F1231528'-6"20'-0"7018065760
F1241628'-6"24'-0"8141077020
F1251632'-6"24'-0"9107086450
F1261732'-6"28'-0"10280098090
AWLSingle Fan CellEach Cell Add
for construction. Obtain current drawings from your Marley
representative.
2 Operating weight is total wet weight including stainless steel
collection basin with 6" (recommended operating water level)
of water.
3 Purchaser to design, construct and furnish supporting steel
complete with 13⁄16" diameter holes for anchor bolts to suit the
general dimensions of current Marley drawings.
DimensionsOperating Weight lb
PLAN
ELEVATION
4 Last number of model indicates number of cells. Change as ap-
propriate for your selection. Primary engineering data is per cell.
5 Maintain no less than 2'-0" of clear space at tower endwalls for
construction purposes. Louvered faces must have unobstructed air supply. If obstructions exist nearby, consult your Marley
representative.
Marley / Sigma F Series Cooling Tower / Engineering Data : Support
A
SPACES AT 4'-0" =
L
6" MIN
TYP
SUMP
SEE NOTE 7
OPTIONAL PA RTITION WALL
FOR INDIVIDUAL CELL OPERATION
B
B
P
AIR INLET FACE
AIR INLET FACE
CASED ENDWALL FACE
CASED ENDWALL FACE
W
IN TO IN OF CURB WALLS
1'-6"
1'-0"
TOP OF BASIN CURB
OPERATING WATER
LEVEL RECOMMENDED
1'-6"
TOP OF BASIN CURB
1'-4"
6" MIN
TOP OF PARTITION WALL
6
NOTE
1 Use this bulletin for preliminary layouts only. Do not use
for construction. Obtain current drawings from your Marley
representative.
2 Tower weight is total wet operating weight of tower only ex-
cluding water in the concrete basin.
3 Purchaser to design, construct and furnish concrete basin
complete to suit the general dimensions of current Marley
drawings.
4 Last number of model indicates number of cells. Change as ap-
propriate for your selection. Primary engineering data is per cell.
PLAN
SECTION B
Tower
Model
Note 4
F1211426'-4"16'-0"3922035920
F1221428'-4"16'-0"4146038160
F1231528'-4"20'-0"4820044860
F1241628'-4"24'-0"5530051980
F1251632'-4"24'-0"6126057880
F1261732'-4"28'-0"6828064800
AWLSingle Fan CellEach Cell Add
DimensionsOperating Weight lb
5 All anchor bolts complete with nut and washer will be furnished
by others. Bolts are
3
⁄4" diameter with 11⁄2" all thread projection.
Material should be stainless steel.
6 Maintain no less than 2'-0" of clear space at tower endwalls for
construction purposes. Louvered faces must have unobstructed air supply. If obstructions exist nearby, consult your Marley
representative.
7 Purchaser must design, construct, and furnish sump(s) and
overflow(s) to suit requirements. The sump should be designed
according to the pump manufacturer's recommendations.
SECTION P
Marley / Sigma F Series Cooling Tower / Engineering Data : Piping Plan 2
C
MOTOR
C
F
COLUMN AND
ANCHOR BOLT
TYP. SINGLE CELL
D
TYP. MULTICELL
C
L
COLUMN AND
ANCHOR BOLT
C
L
INLET
C
L
TOWER
AND FAN
C
L
FAN
C
L
FAN
C
L
INLET
C
L
INLET
C
L
F
FAN TOWER
C
L
INLET
C
L
MOTOR
CONCRETE
BASIN OPTION
B
DIAMETER
CROSSOVER PIPE
STAINLESS
STEEL BASIN
OPTION
E
FACE OF A DIA. GALVANIZED FLANGE
PIPING
LOADS SUPPORTED
BY OTHERS
PIPING
LOADS SUPPORTED
BY TOWER
FLANGE IS
3
/
4" THICK. BOLT
CIRCLE CONFORMS TO 125 LB.
ANSI SPECIFICATIONS
BASE OF
TOWER COLUMNS
PLAN
7
NOTE
1 Use this bulletin for preliminary layouts only. Obtain current
drawings from your Marley representative.
2 Pumping head contributed by the tower is static lift E. Actual
pumping head will vary according to tower circulating GPM.
Total pumping head will be furnished at time of proposal.
3 If your application requires a bypass system, recommended
location is through the tower endwall into the plenum area.
Review of the system by SPX engineering is required.
END ELEVATION
Tower
Model
Flow/Cell
GPM
F12101050-575012"10"8'-0"16'-0"15'-10
F12201050-575014"12"8'-0"16'-0"15'-11
F12301320-720014"12"10'-0"20'-0"15'-11
F12401500-865014"12"12'-0"24'-0"15'-11
F12501500-865016"14"12'-0"24'-0"16'-0
ABCDEF
F12601850-1010016"14"14'-0"28'-0"16'-0
4 All header and riser piping to be furnished by others.
A corrosion-resistant material or coating for piping is
recommended. All inlet piping loads, including thrust and
seismic, outside of tower plan area must be supported by
others.
Dimensions
7
⁄8"7'-6"
7
⁄8"8'-6"
7
⁄8"8'-6"
7
⁄8"8'-6"
7
⁄8"10'-6"
7
⁄8"10'-6"
Marley / Sigma F Series Cooling Tower / Engineering Data : Piping Plan 3
C
H
MOTOR
C
F
COLUMN AND
ANCHOR BOLT
TYP. SINGLE CELL
D
TYP. MULTICELL
C
L
COLUMN AND
ANCHOR BOLT
C
L
RISER
C
L
TOWER
AND FAN
C
L
FA N
C
L
FA N
C
L
RISER
C
L
F
FA NTOWER
C
L
INLET RISER
C
L
MOTOR
CONCRETE
BASIN OPTION
B
DIAMETER
CROSSOVER PIPE
26" x 26" INTERNAL
RISER SLEEVE / AIR
SEAL (SS BASIN)
STAINLESS
STEEL BASIN
OPTION
H
E
G
FAN
10
1
/
8
"
BASE OF
TOWER COLUMNS
RISER
CLC
L
C
L
FACE OF A DIA. GALVANIZED FLANGE
FLANGE IS
3
/
4
" THICK. BOLT
CIRCLE CONFORMS TO 125 LB.
ANSI SPECIFICATIONS
8
PLAN
Tower
Model
F12101050-575012"10"8'-0"16'-0"15'-0
F12201050-575014"12"8'-0"16'-0"15'-1
F12301320-720014"12"10'-0"20'-0"15'-1
F12401500-865014"12"12'-0"24'-0"15'-1
F12501500-865016"14"12'-0"24'-0"15'-2
F12601850-1010016"14"14'-0"28'-0"15'2
END ELEVATION
Flow/Cell
GPM
ABCDEFGH
Dimensions
SIDE ELEVATION
3
⁄4"3'-3"1'-77⁄8"2'-6"
3
⁄4"3'-6"1'-77⁄8"2'-6"
3
⁄4"3'-6"2'-77⁄8"3'-6"
3
⁄4"3'-6"1'-77⁄8"2'-6"
3
⁄4"3'-9"1'-77⁄8"2'-6"
3
⁄4"3'-9"3'-17⁄8"3'-9"
Marley / Sigma F Series Cooling Tower / Engineering Data : Piping Plan 4
C
H
MOTOR
C
F
COLUMN AND
ANCHOR BOLT
TYP. SINGLE CELL
D
TYP. MULTICELL
C
L
COLUMN AND
ANCHOR BOLT
C
L
RISER AND
HEADER
C
L
TOWER
AND FAN
C
L
FA N
C
L
FA N
C
L
RISER
C
L
H
E
G
FAN
FLANGE IS
3
/
4
" THICK. BOLT
CIRCLE CONFORMS TO 125 LB.
ANSI SPECIFICATIONS
10
1
/
8
"
1'-7"
BASE OF
TOWER COLUMNS
RISER
CLC
L
C
L
FACE OF A DIA. GALVANIZED FLANGE
F
FA NTOWER
C
L
INLET RISER
C
L
MOTOR
CONCRETE
BASIN OPTION
B
DIAMETER
CROSSOVER PIPE
STAINLESS
STEEL BASIN
OPTION
9
PLAN
NOTE
1 Use this bulletin for preliminary layouts only. Obtain current
drawings from your Marley representative.
2 Pumping head contributed by the tower is static lift E. Actual
pumping head will vary according to tower circulating GPM. Total
pumping head will be furnished at time of proposal.
3 If your application requires a bypass system, recommended location
is through the tower endwall into the plenum area. Review of the
system by SPX engineering is required.
END ELEVATION
SIDE ELEVATION
4 All header and riser piping to be furnished by others. A corrosion-
resistant material or coating for piping is recommended. Do not
support riser dead load or operating load from inlet connection or
tower structure.