SPX Cooling Technologies FSIG-TS-08A User Manual

Marley Sigma F Series Cooling Tower
/
/
Engineering Data & Specifications
Marley / Sigma F Series Cooling Tower / Table of Contents
Engineering Data
Schematic 4 Support 5 Piping 7 Temperature Control 10 Environmental 11
Specifications / Base
Base 12 Thermal Performance 13 Construction 14 Fan Deck and Fan Cylinder 15 Mechanical Equipment 15 Fill, Louvers and Drift Eliminators 16 Hot Water Distribution System 17 Casing 17 Access and Safety 18 Cold Water Basin 18 Scope of Work 19
Specifications / Options
Cold Water Basin Options
Stainless Steel Cold Water Basin 20 Watertight Partition between Tower Cells 20 Basin Heater 20
Convenience and Safety Options
Fiberglass Stairway 21 Wood Stairway 21 Plenum Walkway 22 Ladder Extension 22 Ladder Safety Cage 22 Hot Water Basin Covers 22 Air Inlet Screens 23
Appearance Options
Architectural Casing 23 Cased Guardrail 23
Control Options
Control System 24 Variable Speed Drive 25 Vibration Limit Switch 26
Miscellaneous Options
Galvanized Steel Ladder 26 Fiberglass Ladder 26 Low Noise Tower 27 Fire-Retardant Fiberglass 27 Fan Cylinder Extension 27 Increased Wind and/or Earthquake Load 27 Premium Hardware 27
Marley / Sigma F Series Cooling Tower
/
3
he Sigma F Series is a field-erected, crossflow,
T
fiberglass-structure cooling tower designed to serve normal air conditioning and refrigeration systems as well as medium sized industrial loads. Evolving from the crossflow concept of cooling tower pioneered by Marley in 1938, and incorporating over 65 years of design advancements, the Sigma F Series represents the current state of the art in this cooling tower category.
This booklet not only relates the language to use in describing an appropriate Sigma F Series cooling tower—but also defines why certain items and features are important enough to specify with the intention of insisting upon compliance by all bidders. The left hand column of pages 12 through 27 provides appropriate text for the various specification paragraphs, whereas the right hand column comments on the meaning of the subject matter and explains its value.
Pages 12 through 19 indicate those paragraphs which will result in the purchase of a cooling tower which will not only accomplish the specified thermal performance, but which will include normal operation and maintenance-enhancing accessories and features. It will also incorporate those standard materials which testing and experience has proven to provide best results in normal operating conditions.
Pages 20 through 27 provide some paragraphs intended to add those features, components, and materials that will customize the tower to meet the user's requirements.
Space does not permit definition and explanation of all of the possible options that can be applied to the Sigma F Series. SPX Cooling Technologies realizes that you, the purchaser, must be happy with the tower's characteristics, and we are prepared to provide—or provide for—any reasonable enhancement that you are willing to define and purchase.
Your needs will become part of the continuing improvement of this product line.
Marley / Sigma F Series Cooling Tower / Engineering Data : Schematic
H
B
TOP OF FAN CYLINDER
BASE OF TOWER COLUMNS
FAN DECK
13'-6"
W OUT-TO-OUT OF TOWER
A BAYS AT 4'-0" = L
C
DIAMETER FAN
3"3"
COLUMNCOLUMN
C
L
C
L
COLUMN
C
L
TOWER PLAN
4
Use this data for preliminary layouts only. Obtain current drawing from your Marley sales representative.
The UPDATE web-based selection software — available at spxcooling.com — provides Sigma F Series model recommendations based on customer's specific design requirements.
Tower Model
F1211 29'-2" 16'-0" 19'-6" 4 6'-0" 144"
F1221 31'-2" 16'-0" 20'-6" 4 7'-0" 168"
F1231 31'-2" 20'-0" 20'-6" 5 7'-0" 168"
F1241 31'-2" 24'-0" 20'-6" 6 7'-0" 168"
F1251 35'-2" 24'-0" 20'-6" 6 7'-0" 216"
F1261 35'-2" 28'-0" 20'-6" 7 7'-0" 216"
W L H A B C
NOTE
1 Use this bulletin for preliminary layouts only. Obtain current
drawings from your Marley representative. 2 All table data is per cell. 3 All tower installations require a minimum of 4'-0" from cen-
terline of tower endwall column to any vertical obstruction at
tower ladder location. Ladder can be located at any corner of
the fan deck. Ladder extends 8
3
8" below the base of tower
ENDWALL ELAVATION
Dimensions
columns on applications with a stainless steel cold water basin. Ladder stops at top of basin curb wall on applications with a concrete basin. Tower installations with an elevation 20'-0" or more from the top of the fan deck to grade or roof level require a safety cage on the tower ladder in compliance with OSHA standards. Marley ladder safety cages are available as an option.
Marley / Sigma F Series Cooling Tower / Engineering Data : Support
A
SPACES AT 4'-0" =
L
W
OVERALL OF BASIN
SUMP
OVERFLOW
MAKEUP VALVE
INTERMEDIATE BEAM
AIR INLET FACE
AIR INLET FACE
CASED ENDWALL FACE
CASED ENDWALL FACE
PRIMARY SUPPORT BEAM
2 1/4" MAX.
NORMAL GAGE
COL. & ANCH. BOLT
C
L
5
SECTION
Tower Model
Note 4
NOTE
1 Use this bulletin for preliminary layouts only. Do not use
F1211 4 26'-6" 16'-0" 55810 51510
F1221 4 28'-6" 16'-0" 59300 54920
F1231 5 28'-6" 20'-0" 70180 65760
F1241 6 28'-6" 24'-0" 81410 77020
F1251 6 32'-6" 24'-0" 91070 86450
F1261 7 32'-6" 28'-0" 102800 98090
A W L Single Fan Cell Each Cell Add
for construction. Obtain current drawings from your Marley
representative. 2 Operating weight is total wet weight including stainless steel
collection basin with 6" (recommended operating water level)
of water. 3 Purchaser to design, construct and furnish supporting steel
complete with 13⁄16" diameter holes for anchor bolts to suit the
general dimensions of current Marley drawings.
Dimensions Operating Weight lb
PLAN
ELEVATION
4 Last number of model indicates number of cells. Change as ap-
propriate for your selection. Primary engineering data is per cell.
5 Maintain no less than 2'-0" of clear space at tower endwalls for
construction purposes. Louvered faces must have unobstruct­ed air supply. If obstructions exist nearby, consult your Marley representative.
Marley / Sigma F Series Cooling Tower / Engineering Data : Support
A
SPACES AT 4'-0" =
L
6" MIN
TYP
SUMP
SEE NOTE 7
OPTIONAL PA RTITION WALL FOR INDIVIDUAL CELL OPERATION
B
B
P
AIR INLET FACE
AIR INLET FACE
CASED ENDWALL FACE
CASED ENDWALL FACE
W
IN TO IN OF CURB WALLS
1'-6"
1'-0"
TOP OF BASIN CURB
OPERATING WATER LEVEL RECOMMENDED
1'-6"
TOP OF BASIN CURB
1'-4"
6" MIN
TOP OF PARTITION WALL
6
NOTE
1 Use this bulletin for preliminary layouts only. Do not use
for construction. Obtain current drawings from your Marley representative.
2 Tower weight is total wet operating weight of tower only ex-
cluding water in the concrete basin.
3 Purchaser to design, construct and furnish concrete basin
complete to suit the general dimensions of current Marley drawings.
4 Last number of model indicates number of cells. Change as ap-
propriate for your selection. Primary engineering data is per cell.
PLAN
SECTION B
Tower Model
Note 4
F1211 4 26'-4" 16'-0" 39220 35920
F1221 4 28'-4" 16'-0" 41460 38160
F1231 5 28'-4" 20'-0" 48200 44860
F1241 6 28'-4" 24'-0" 55300 51980
F1251 6 32'-4" 24'-0" 61260 57880
F1261 7 32'-4" 28'-0" 68280 64800
A W L Single Fan Cell Each Cell Add
Dimensions Operating Weight lb
5 All anchor bolts complete with nut and washer will be furnished
by others. Bolts are
3
4" diameter with 11⁄2" all thread projection.
Material should be stainless steel.
6 Maintain no less than 2'-0" of clear space at tower endwalls for
construction purposes. Louvered faces must have unobstruct­ed air supply. If obstructions exist nearby, consult your Marley representative.
7 Purchaser must design, construct, and furnish sump(s) and
overflow(s) to suit requirements. The sump should be designed according to the pump manufacturer's recommendations.
SECTION P
Marley / Sigma F Series Cooling Tower / Engineering Data : Piping Plan 2
C
MOTOR
C
F
COLUMN AND ANCHOR BOLT
TYP. SINGLE CELL
D
TYP. MULTICELL
C
L
COLUMN AND ANCHOR BOLT
C
L
INLET
C
L
TOWER
AND FAN
C
L
FAN
C
L
FAN
C
L
INLET
C
L
INLET
C
L
F
FAN TOWER
C
L
INLET
C
L
MOTOR
CONCRETE BASIN OPTION
B
DIAMETER
CROSSOVER PIPE
STAINLESS STEEL BASIN OPTION
E
FACE OF A DIA. GALVANIZED FLANGE
PIPING LOADS SUPPORTED BY OTHERS
PIPING
LOADS SUPPORTED
BY TOWER
FLANGE IS
3
/
4" THICK. BOLT
CIRCLE CONFORMS TO 125 LB. ANSI SPECIFICATIONS
BASE OF TOWER COLUMNS
PLAN
7
NOTE
1 Use this bulletin for preliminary layouts only. Obtain current
drawings from your Marley representative.
2 Pumping head contributed by the tower is static lift E. Actual
pumping head will vary according to tower circulating GPM. Total pumping head will be furnished at time of proposal.
3 If your application requires a bypass system, recommended
location is through the tower endwall into the plenum area. Review of the system by SPX engineering is required.
END ELEVATION
Tower
Model
Flow/Cell
GPM
F1210 1050-5750 12" 10" 8'-0" 16'-0" 15'-10
F1220 1050-5750 14" 12" 8'-0" 16'-0" 15'-11
F1230 1320-7200 14" 12" 10'-0" 20'-0" 15'-11
F1240 1500-8650 14" 12" 12'-0" 24'-0" 15'-11
F1250 1500-8650 16" 14" 12'-0" 24'-0" 16'-0
A B C D E F
F1260 1850-10100 16" 14" 14'-0" 28'-0" 16'-0
4 All header and riser piping to be furnished by others.
A corrosion-resistant material or coating for piping is recommended. All inlet piping loads, including thrust and seismic, outside of tower plan area must be supported by others.
Dimensions
7
8" 7'-6"
7
8" 8'-6"
7
8" 8'-6"
7
8" 8'-6"
7
8" 10'-6"
7
8" 10'-6"
Marley / Sigma F Series Cooling Tower / Engineering Data : Piping Plan 3
C
H
MOTOR
C
F
COLUMN AND ANCHOR BOLT
TYP. SINGLE CELL
D
TYP. MULTICELL
C
L
COLUMN AND ANCHOR BOLT
C
L
RISER
C
L
TOWER
AND FAN
C
L
FA N
C
L
FA N
C
L
RISER
C
L
F
FA NTOWER
C
L
INLET RISER
C
L
MOTOR
CONCRETE BASIN OPTION
B
DIAMETER
CROSSOVER PIPE
26" x 26" INTERNAL RISER SLEEVE / AIR SEAL (SS BASIN)
STAINLESS STEEL BASIN OPTION
H
E
G
FAN
10
1
/
8
"
BASE OF TOWER COLUMNS
RISER
CLC
L
C
L
FACE OF A DIA. GALVANIZED FLANGE
FLANGE IS
3
/
4
" THICK. BOLT CIRCLE CONFORMS TO 125 LB. ANSI SPECIFICATIONS
8
PLAN
Tower
Model
F1210 1050-5750 12" 10" 8'-0" 16'-0" 15'-0
F1220 1050-5750 14" 12" 8'-0" 16'-0" 15'-1
F1230 1320-7200 14" 12" 10'-0" 20'-0" 15'-1
F1240 1500-8650 14" 12" 12'-0" 24'-0" 15'-1
F1250 1500-8650 16" 14" 12'-0" 24'-0" 15'-2
F1260 1850-10100 16" 14" 14'-0" 28'-0" 15'2
END ELEVATION
Flow/Cell
GPM
A B C D E F G H
Dimensions
SIDE ELEVATION
3
4" 3'-3" 1'-77⁄8" 2'-6"
3
4" 3'-6" 1'-77⁄8" 2'-6"
3
4" 3'-6" 2'-77⁄8" 3'-6"
3
4" 3'-6" 1'-77⁄8" 2'-6"
3
4" 3'-9" 1'-77⁄8" 2'-6"
3
4" 3'-9" 3'-17⁄8" 3'-9"
Marley / Sigma F Series Cooling Tower / Engineering Data : Piping Plan 4
C
H
MOTOR
C
F
COLUMN AND ANCHOR BOLT
TYP. SINGLE CELL
D
TYP. MULTICELL
C
L
COLUMN AND ANCHOR BOLT
C
L
RISER AND
HEADER
C
L
TOWER
AND FAN
C
L
FA N
C
L
FA N
C
L
RISER
C
L
H
E
G
FAN
FLANGE IS
3
/
4
" THICK. BOLT CIRCLE CONFORMS TO 125 LB. ANSI SPECIFICATIONS
10
1
/
8
"
1'-7"
BASE OF TOWER COLUMNS
RISER
CLC
L
C
L
FACE OF A DIA. GALVANIZED FLANGE
F
FA NTOWER
C
L
INLET RISER
C
L
MOTOR
CONCRETE BASIN OPTION
B
DIAMETER
CROSSOVER PIPE
STAINLESS STEEL BASIN OPTION
9
PLAN
NOTE
1 Use this bulletin for preliminary layouts only. Obtain current
drawings from your Marley representative.
2 Pumping head contributed by the tower is static lift E. Actual
pumping head will vary according to tower circulating GPM. Total pumping head will be furnished at time of proposal.
3 If your application requires a bypass system, recommended location
is through the tower endwall into the plenum area. Review of the system by SPX engineering is required.
END ELEVATION
SIDE ELEVATION
4 All header and riser piping to be furnished by others. A corrosion-
resistant material or coating for piping is recommended. Do not support riser dead load or operating load from inlet connection or tower structure.