SoundOff Signal 400 User Manual

0 (0)
SoundOff Signal 400 User Manual

400 SERIES AMPLIFIER BOX

 

 

 

 

 

 

 

 

 

Internal Relay Board Fuse replacement:

 

 

PSRN4ANR1

 

RED/ BLACK

Right Alley for signle button Alley control

 

 

 

To replace fuses:

 

 

 

PSRN4ANR2

 

Auxiliary Push-Button 7 Normally Open Output *

 

 

 

 

 

 

 

 

 

 

GREEN/ BLACK

 

 

 

1. Remove power connectors CN8 and CN6 or remove power

 

Auxiliary Push-Button 8 Normally Open Output *

 

 

 

 

 

 

 

CONTROL PANEL

 

 

 

 

RED/ WHITE

Auxiliary Push-Button 7 Normally Closed Output *

 

 

to unit.

 

 

 

 

POWERED

 

ORANGE

PSRN4CTRL1

 

2. Remove unit from console or obtain access to full top of unit.

 

Push-Button 4 Output

 

 

OR

 

3. Depress snaps on top cover and lift open.

 

 

OUTPUT WIRING

 

YELLOW

Push-Button 3 Output

RJ45 Cable to Control Panel

 

4. See chart below for output fuse locations and ratings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.

Fuse Ratings: Replace with same rated part.

 

 

 

 

BROWN

Push-Button 2 Output

 

HANDHELD REMOTE

 

 

 

 

 

 

PSRNHHC1

 

6. Close cover, reinstall connectors and reinstall unit in console.

 

 

 

BLUE

 

 

 

 

 

Push-Button 1 Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The button outputs 7 and 8 have the ability to receive power from

 

 

 

 

 

 

 

 

 

CN5

Wire capacity requirements for Relay

an independent external power source or from the internal +V as

 

 

 

 

CN8

 

 

 

incoming power supply for

each wire

supplied to CN8. Both of these outputs use a separate internal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wire Length

Minimum Wire Gauge

10A mini-ATO fuse which rely on position to determine the source

 

 

 

 

 

 

 

 

 

 

selection. Each fuse may be placed in one of 2 locations. See

 

 

 

CN3

5 4

3

2

1

 

 

0-10 Feet

10 AWG

 

 

 

 

 

diagram below.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10-15 Feet

8 AWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15-25 Feet

6 AWG

* If the fuse is placed in the fuse holder near the back edge

 

 

 

 

 

 

 

 

 

 

25+ Feet

Consult Factory

of the PCB that output will be powered from an external source,

 

 

 

 

 

 

 

 

 

 

 

 

 

labeled “relay #(x) input” on CN3.

 

 

 

 

 

 

 

 

 

 

 

YELLOW

 

 

 

 

** If the fuse is placed in the fuse holder away from the back

*Auxiliary Push Button #8

GREEN/WHITE

RED

RED

BLUE

GREEN

 

 

 

 

edge of the PCB that output will be powered from the internal +V

 

 

 

 

source that comes from CN8 pin 5.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normally Closed Output

 

 

 

 

 

 

 

Slide Switch Level 3 Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not used

 

 

 

 

 

 

 

Slide Switch Level 2 Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSE CHART

 

FUSE LOCATIONS ON RELAY PCB

*Relay #8 Input

GREEN

 

 

 

 

 

Slide Switch Level 1 Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

Relay #7 Input

RED

 

 

 

 

50A

+ V

 

LOCATION

RATING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSE

 

 

 

 

 

 

 

 

Relay #9 Output for

 

GREY

 

 

 

 

50A

+ V

 

FB-8

10A

 

 

 

 

 

 

2 wire Arrow Control Interface

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSE

 

 

FB-7

10A

 

 

 

 

 

 

 

 

 

VIOLET

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary Push Button #6 Output

 

 

 

 

 

 

 

FB-4

10A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary Push Button #5 Output

WHITE

 

 

 

 

 

 

 

FB-3

10A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FB-2

10A

**INTERNAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FB-1

10A

*EXTERNAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORMALLY OPEN

 

To Device requiring power

FB-5

10A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTACT RELAY

 

only when Ignition Switch

FB-6

10A

 

 

 

 

 

 

 

+V when Ignition

1 1

 

 

 

 

is on

 

FB-9

10A

 

8 7

4 3 2 1 5 6 9

 

 

 

 

 

 

 

 

 

 

 

1

2

3

 

Switch is ON

1 Amp

 

 

 

3

 

 

 

FS-1

20A

 

AUXILARY PUSH BUTTON

SLIDE SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

2 2

 

 

 

 

 

FS-2

20A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FS-3

20A

 

Slide Switch Level Outputs 1-3 and Button Outputs 1-6 are

 

 

 

 

 

 

 

 

 

NOTICE:

 

 

 

 

active high (vehicle supply level).

 

 

 

 

 

 

 

 

 

 

 

 

When an output is connected to a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

device which is required to function

 

 

 

 

 

 

 

 

 

 

 

From Siren

 

 

only when ignition switch is ON, a

 

 

 

 

 

 

 

 

 

 

 

 

 

relay needs to be installed in-line with

 

 

 

 

 

 

 

 

 

 

 

Switch Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the siren switch output to ensure an

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

operator can’t activate the device

 

 

 

 

 

 

1.800.338.7337 / www.soundoffsignal.com

 

 

 

 

 

*= Not used on Hand Held Version

 

 

 

 

 

 

 

 

without the ignition switch ON.

 

ETSA46(x)HPP 3.4.13

5

 

 

 

 

 

 

 

 

See wiring diagram details:

 

 

 

 

 

 

 

HANDHELD REMOTE

PSRNHHC1

PROGRAMMING MANUAL

LEGEND:

ON = NOTE:

For All programming modes: Momentarily depress Radio Rebroadcast push-button to save and exit.

To hear samples of all the tones available go to

www.sousoundoffsignal.com website.

Denotes Factory Default Setting

Programming Modes

Auxiliary Button Programming:

1.Press and Hold Auxiliary Button #1 and #6 until Level 1 LED Flashes.

2.Press the auxiliary button which setting is going to be viewed/ changed.

3.Monitor the Arrow/Alley LED’s to determine setting for Auxiliary Button

Toggle ON/OFF

Momentary ON

8 Second Delay

Left Arrow

Right Arrow

Center Out - Arrow

Alley Left

Alley Right

Single Button Arrow

Single Button Alley

4.Press and release Auxiliary Button until desired mode is selected.

5.Continue steps 2-4 for any other Auxiliary Buttons needing to be programmed.

Slide Switch Mode:

1.Press and Hold Auxiliary Button #1 and #4 until Level 2 LED flashes.

2.Press Auxiliary switch 1, 2, or 3 depending on required mode of operation.

Aux 1: Progressive 1,2,3

Level 1 selected: Active Outputs: 1

Level 2 selected: Active Outputs: 1,2

Level 3 selected: Active Outputs: 1,2,3

Aux: 2 Progressive 1,2,3 with option to turn off lower levels Level 1 selected: Active Outputs: 1

Level 2 selected: Active Outputs: 1,2 (Level 1 may be turned OFF) Level 3 selected: Active Outputs: 1,2,3 (Level 1 and 2 may be

turned OFF)

Aux 3: Individual 1,2,3

Level 1 selected: Active Outputs: 1 Level 2 selected: Active Outputs: 2 Level 3 selected: Active Outputs: 3

1.800.338.7337 / www.soundoffsignal.com

Input Settings:

1. Press and Hold Auxiliary Button #1 and #3 until LEVEL #3 LED flashes.

1. Park Kill Polarity Mode: Determines what voltage level will activate park kill functions. Disables AUX Input

ON=ActivatedwhenGroundisappliedtoPark Kill input wire.

OFF = Activate when +V is applied to Park Kill

input wire

2. Horn Ring Polarity Mode: Determines what voltage level will activate Horn Ring functions.

ON = Activated when Ground is applied to Horn

Ring input wire.

OFF = Activated when +V is applied to Horn

Ring input wire.

3. PA Volume Control (see Setting PA Volume)

ON = RR Button Adjustable

OFF = Programmed

4. Level 3 Tone Activation: Determines when the siren tone push-buttons on control panel are enabled.

ON = Tone push buttons always enabled

OFF = Tone push button only enabled with slide switch is in position #3.

5. 8 Second Buzzer alert: Provides audible beep when ever any auxiliary switches are ON or level 1, 2 or 3 is active.

ON = Enabled

OFF = Disabled

6. Air Horn Button Output Channels

ON = In standby mode, Air Horn tone is output on Spkr A & B. When Warning Tone is Active, Warning Tone continues on Spkr A & Air Horn Button Tone is output on Spkr B

OFF = Air Horn Button Tone always produced on Spkr A & B.

ETSA46(x)HPP 3.4.13