SPECIFICATIONS
AUDIO POWER SPECIFICATIONS
POWER OUTPUT AND TOTAL HARMONIC DISTORTION:
With 8 ohm loads, both channels driven, from 20 - 20,000 Hz; rated
110 watts per channel minimum RMS power, with no more than
0.09% total harmonic distortion from 250 milliwatts to rated output
(USA model only).
Amplifier section
POWER OUTPUT
Stereo mode
Surround mode
a)Depending on the sound field settings and the source, there may be no
sound output.
Dynamic power output
Harmonic distortion at rated output
Frequency response
(8 ohms 20 Hz - 20 kHz, THD 0.09%)
110 W + 110 W
(8 ohms at 1 kHz, THD 0.8%)
Front: 110 W/ch
Centera): 110 W
Reara): 110 W/ch
165 W + 165 W, 8 ohms
230 W + 230 W, 4 ohms
Less than 0.09% (with sound field, tone, and bass
booster bypassed)
PHONO: RIAA
equalization curve
±0.5 dB
CD, TAPE, MD/DAT, TAPE/MD, DVD/LD, TV/DBS,
VIDEO 1, 2, and VIDEO 3 :
10 Hz - 50 kHz +0.5/-2 dB (with sound field, tone,
and bass booster bypassed)
Inputs (Analog)
b)78’ IHF
c)Weighted network, input level
Inputs (Digital)
Outputs
US Model
Canadian Model
E Model
PX Model
STR-DE925
Chinese Model
STR-V919
PHONO:
Sensitivity: 2.5 mV
Impedance: 50 kilohms
S/Nb): 75 dB (A, 2.5 mVc))
CD, DVD/LD, TAPE, MD/DAT, TAPE/MD, TV/DBS,
VIDEO 1, 2, and VIDEO 3 :
Home Audio Company
Published by Sony Engineering Corporation
BASS BOOST
+6 dB at 70 Hz
Sampling Frequency
48 kHz
EQ
BASS:
100 Hz ~ 1.0 kHz (21 steps)
MID:
500 Hz ~ 5.0 kHz (21 steps)
TREBLE:
1.0 kHz ~ 10 kHz (21 steps)
Gain levels:
±10 dB, 1 dB step
FM tuner section
Tuning range
87.5 - 108.0 MHz
Antenna terminals
75 ohms, unbalanced
Sensitivity
Mono: 18.3 dBf, 4.5 µV
Stereo: 38.3 dBf, 45 µV
Usable sensitivity
11.2 dBf, 2 µV (IHF)
S/N
Mono: 76 dB
Stereo: 70 dB
Harmonic distortion at 1 kHz
Mono: 0.3 %
Stereo: 0.5 %
Separation
45 dB at 1 kHz
Frequency response
30 Hz - 15 kHz +0.5/-2 dB
Selectivity
60 dB at 400 kHz
AM tuner section
Tuning range
With 10-kHz tuning scale:
530 - 1710 kHz
530 - 1610 kHz
With 9-kHz tuning scale:
531 - 1710 kHz
531 - 1602 kHz
Antenna
Loop antenna
Usable sensitivity
50 dB/m (at 1,000 kHz or 999 kHz)
S/N
54 dB (at 50 mV/m)
Harmonic distortion
0.5% (50 mV/m, 400 kHz)
d)
(US, Canadian)
d)
(Except US, Canadian)
d)
(US, Canadian)
d)
(Except US, Canadian)
Selectivity
At 9 kHz: 35 dB
At 10 kHz: 40 dB
d)You can change the AM tuning scale to 9 kHz. After tuning in any AM
station, turn off the receiver. Hold down the TUNING + button and
press the 1/u button. All preset stations will be erased when you
change the tuning scale. To reset the scale to 10 kHz, repeat the
procedure.
Video section
Input
Outputs
1 Vp-p 75 ohms
1 Vp-p 75 ohms
General
System
Tuner section:
PLL quartz-locked digital synthesizer system
Preamplifier section:
Low- noise NF type equalizer
Power amplifier section:
Pure-complementary SEPP
Power requirements
US and Canadian models:
120 V AC, 60 Hz
E, PX, Saudi Arabia models :
120/220/240 V AC selectable, 50/60 Hz
Singapore, Chinese, Malaysia models :
220 - 230 V AC, 50/60 Hz
Power consumption
US, Singapore, Chinese, Malaysia: 290 W
Canadian: 480 VA
E, PX, Saudi Arabia: 310W
AC outlets
Dimensions
2 switched, total 100 W
430 × 370 × 157.5 mm
(17 × 145/8× 61/4 in.)
including projecting parts and controls
Mass (Approx.)
10.5 kg (23 lb 3 oz)
Supplied accessories
• FM wire antenna (1)
• AM loop antenna (1)
• Remote commander RM-LJ301 (remote) (1)
• LR6 (size-AA) alkaline batteries (3)
• Audio/video/control S connecting cord (1)
• Control S connecting cord (1)
Design and specifications are subject to change without notice.
— 2 —
SAFETY CHECK-OUT
TABLE OF CONTENTS
After correcting the original service problem, perform the
following safety checks before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microampers).
Leakage current can be measured by any one of three methods.
1.A commercial leakage tester , such as the Simpson 229 or RCA
WT -540A. Follow the manufacturers’ instructions to use these
instruments.
2.A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3.Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter . The “limit” indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples of
a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2V AC range are suitable. (See
Fig. A)
4-1. Front Panel Section ·························································· 64
4-2. Chassis Section································································· 65
5.ELECTRICAL PARTS LIST ··································· 66
Earth Ground
Fig. A. Using an AC v oltmeter to check A C leakage.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK ! OR DOTTED LINE WITH
MARK ! ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS
LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE
COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS
APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS
PUBLISHED BY SONY .
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!
LES COMPOSANTS IDENTIFÉS P AR UNE MARQUE ! SUR LES
DIAGRAMMES SCHÉMA TIQUES ET LA LISTE DES PIÈCES SONT
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE
REMPLACER CES COMPOSANTS QUE PAR DES PIÈSES SONY
DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU
DANS LES SUPPÉMENTS PUBLIÉS PAR SONY.
— 3 —
LOCATION AND FUNCTION OF CONTROLS
[FRONT PANEL]
SECTION 1
GENERAL
#ª
#•
#¶
#§
#∞
#¢
1
#£
#™
2
#¡
@ª¿
#º
4567890
3
11/u (POWER) button
2MULTI CURSOR CONTROL
3SURROUND, EQUALIZER, INDEX indicators
4DIRECT TUNING button
5VIDEO 1 button
6MULTI CHANNEL DECODING indicator
7TV/DBS button (DE925)
7TV/LD button (V919)
8SOUND FIELD GENRE button
9SOUND FIELD MODE button
0SOUND FIELD, EQ, BASS BOOST indicators
!¡MASTER VOLUME control
!™BALANCE control
!£VIDEO 3 INPUT
!¢MUTING button
!∞SOUND FIELD ON/OFF button
!§BASS BOOST button
!¶EQ ON/OFF button
!•INPUT MODE button
!ªPHONO button
@ºDVD/LD
* All fluorescent segments are tested. When this test is activated,
all segments turn on at the same time, then each segment turns on
one after another.
* Procedure:
While depressing the SET UP and the SOUND FIELD MODE
buttons simultaneously, press the power [1/u] button to turn on
the main power. All segments turn on at the same time, then each
segment turns on one after another.
FACTORY SET MODE
* All preset contents are reset to the default setting.
* Procedure:
While depressing the SET UP and the SOUND FIELD ON/OFF
buttons simultaneously, press the power [1/u] button to turn on
the main power. The message FACTORY SET appears and the
present contents are reset to the default values.
ALL CLEAR MODE
* All preset contents are cleared when this mode is activated. Use
this mode before returning the product to clients upon completion
of repair.
* Procedure:
While depressing the DISPLAY and the SOUND FIELD ON/
OFF buttons simultaneously, press the power [ 1/u] button to turn
on the main power. The machine enters the DEMO mode.DEMO
mode: Wait a while, then the demonstration starts. If the power
[1/u] button is pressed often the demonstration has started, the
power is turned off, and the demonstration resumes if the power
[1/u] button is pressed again.
ALL CLEAR mode; If the power [1/u] button is pressed often
the machine enters the DEMO mode, but before the demonstration
starts, the display is turned off. Press [1/u] again. No response is
returned. The press [1/u] again. The preset data is cleared and
the machine enters the normal power-on state.
SOUND FIELD CLEAR MODE
* The preset sound field is cleared when this mode is activated.
Use this mode before returning the product to clients upon
completion of repair.
* Procedure:
While depressing the SOUND FIELD ON/OFF button, press the
power [1/u] button to turn on the main power. The message
SURR CLEAR! appears and initialization is performed.
AM CHANNEL STEP 9 kHz/10 kHz
SELECTION MODE
* Either the 9 kHz step or 10 kHz step can be selected for the AM
channel step.
* Procedure:
Set the FUNCTION to AM. Turn off the main power.
While depressing the TUNING+ button or the PRESET TUNING
+ button, press the power [1/u] button to turn on the main power.
Either the message AM 9kHz STEP or AM 10kHz STEP appears.
Select the desired step.
DSP TEST MODE
* Procedure:
While depressing the SET UP and the SOUND FIELD GENRE
buttons simultaneously, press the power [1/u] button to turn on
the main power. The message DSP NO ERROR or DSP ERROR.
DTS MODE
* Procedure:
While depressing the MUL TI CURSOR CONTROL UP [>] and
DOWN [.] buttons simultaneously , press the power [1/u] button
to turn on the main power. The message ATTENUATE OFF or
ATTENUATE ON.
3-13. SCHEMATIC DIAGRAM — DISPLAY SECTION — • See page 8 for Waveform. • See page 51 for IC Pin Function Description. • See page 61 for IC Block Diagrams.