Instructions
READ BEFORE USE
IMPORTANT INSTRUCTIONS
Only for South Africa
EN
Additional installation information for
SMEG gas hobs and stoves supplied to
South Africa
All Smeg appliances comply with SANS
1539 and have been issued with Permit
numbers by the Liquefied Petroleum Gas
Safety Association of Southern Africa.
Gas Type: LPG (Note: This appliance may
have been supplied ex factory with setting
and jets for Natural Gas. Your installer must
make the necessary changes and
adjustments before handing over the
installed appliances for use).
Operating Pressure: 2.8 kPa. Note that this
appliance may only be used with a LPG
regulator of 2.8 kPa outlet pressure and that
complies with requirements of SABS 1237.
• This appliance may only be installed by
a registered LPGas Practitioner/Installer.
All registered Gas fitters are provided
with an identity card, which also carries
their registration number. Make a note of
this. The LPGas Practitioner/Installer
should also provide you with a written
certificate after completing the work.
Before the installer hands over the
installed appliance ensure that you are
informed of the location of the isolation
or shut off valve in the gas supply line to
the appliance and how to operate it.
• Do not modify the appliance in any way
as this may make it unsafe.
• Note carefully the ventilation
requirements indicated in the specific
model instruction booklet. This
information is vital for the safety of the
occupants of the area in which the
appliance is installed and used.
• Never check for gas leaks with a naked
flame. Always use a soapy water
solution applied with a brush to the areas
where you suspect there may be a gas
leak. Do not use the appliance if you
suspect a gas leak.
• There are no preset service intervals for
this appliance. Refer to the section on
maintenance and cleaning in the
instruction booklet for details on how to
care for your SMEG appliance.
• After removing burner caps or burner
heads to clean them or the hob surface
around the burners, always take care
that the burner heads are properly
located in position and that the igniter
post and flame failure thermocouple are
not damaged in any way. It is important
that these devices fit correctly into the
location holes provided in the burner
heads. They will not function correctly if
not properly located. The burner caps
locate by means of the ridge on the
underside. Note that burners will not
work efficiently if the burner caps are not
properly located. There are drawings of
a typical burner assembly in your
instruction booklet.
Instructions
FOR YOUR SAFETY
IF YOU SMELL GAS:
• Turn off gas supply at bottle
• Extinguish all naked flames
• Do not operate any electrical
appliances
• Ventilate the area
• Check for leaks as detailed in this
manual
If odour persists, contact your dealer or gas
supplier immediately.
Do not tamper with the appliance.
BURN-BACK (FIRE IN BURNER TUBE OR
CHAMBER)
In the event of a burn-back, where the flame
burns back to the jet, immediately turn off
the gas supply at the control valve on the
panel. After ensuring the flame is
extinguished, wait for 1 minute and re-light
the appliance in the normal manner. Should
the appliance burn back again, close the
control valve and call a service technician.
Do not use the appliance again until the
service technician has declared that it is
safe to do so.
GAS-PRESSURE REGULATOR
This appliance requires an operating
pressure of 2,8 kPa at the appliance. A
suitable LPG regulator that complies with
the requirements of the current edition of
SANS 1237 must be installed.
IMPORTANT INFORMATION FOR THE
USER
This appliance may only be installed by a
registered LP Gas installer. All registered
installers are provided with a card carrying
their registration number. Ask to be shown
the card before allowing the installation
work to commence and make a note of the
Installer QCC number. Upon completion of
the installation, the installer is required to
explain the operational details of the
appliance together with the safety
instructions. You will be asked to sign
acceptance of the installation and be
provided with a Certificate of Compliance
(CoC). You should only sign for
acceptance of the installation when the
installation is completed to your satisfaction.
Note that your invoice is required in the
event that you wish make a guarantee
claim. Keep the CoC in a safe place as it
may be required in the future (e.g. when
selling your property).
IMPORTANT INFORMATION FOR THE
INSTALLER.
This appliance may only be installed by a
LP gas installer registered with the South
African Qualification and Certification
Committee for Gas (SAQCC Gas). The
appliance must be installed in accordance
with the requirements of the current edition
and any fire department regulations and/or
local by laws applicable to the area. If in
doubt check with the relevant authority
before undertaking the installation. Upon
completion of the installation you are
required to fully explain and demonstrate to
the user the operational details and safety
practices applicable to the appliance and
the installation, and issue a fully completed
Certificate of Conformity.
913531461/C