Siemens X300 Datasheet

Datasheet
ACUSON X300
Ultrasound
System, Premium Edition (PE)
Release 7.5
TABLE OF CONTENTS
GENERAL INFORMATION 4
TRANSDUCER TECHNOLOGY 6
OPERATING MODES 7
DISPLAY MODES 7
Generic Measurements and Calculations 8 Color Doppler Velocity Imaging 9 Power Doppler Imaging/
Generic Measurements and Calculations 10 M-mode 10 M-mode Image Display 11 M-mode Calipers –
Generic Measurements and Calculations 11 QuickSet User-Programmable
FREEZE, CINE AND CINE POST-PROCESSING FUNCTIONS 11
STUDY TYPES 12
EXAM-SPECIFIC MEASUREMENTS AND REPORTS 12
DIGITAL PATIENT STUDY STORAGE AND ARCHIVING 14
OPTIONS 15
2
TABLE OF CONTENTS
Axius Edge Assisted Ejection Fraction 19 Intracardiac Echocardiography Imaging 19 Live Bi-Plane Endorectal Transducer 20 Cadence Contrast Agent Imaging 20 Barcode Reader 21 Veterinary Imaging 21 Modularis SW Interface 21 DICOM 3.0 Connectivity 21 DICOM Modality Worklist 22 DICOM MPPS – Modality Performed
DOCUMENTATION DEVICES 22
SYSTEM INPUT/OUTPUT 23
SYSTEM DIMENSIONS 23
ELECTRICAL/ENVIRONMENTAL SPECIFICATIONS 23
INTEGRATING THE HEALTHCARE ENTERPRISE (IHE) 24
STANDARDS COMPLIANCE 24
CE DECLARATION 25
EU AUTHORIZED REPRESENTATIVE 25
3
ACUSON X300 Ultrasound System, Premium Edition
The ACUSON X300™ ultrasound system, premium edition (PE) is a portable, compact, shared service imaging solution. The ACUSON X300 PE delivers exceptional clinical performance across a wide variety of applications and streamlines exam workflow with an easy-to-use ErgoDynamic™ imaging system design.
The ACUSON X300 PE combines best-in-class image quality and a robust set of features to meet daily clinical needs.

GENERAL INFORMATION

System Architecture

All-digital signal processing and multi-beam formation technology provide best-in-class imaging in all modes and enable seamless integration of features and options to:
• New generation all-digital beamformer technology enables parallel Quad beam processing of the RF signal data in the time and amplitude domains
- 2D-mode line density: Up to 512 lines
- Processing channels: Up to 22,560 channels
- Total system dynamic range: > 205 dB
• Advance image quality with PLUS Option enhanced imaging and transducers, Native™ tissue harmonic imaging, DTO™ Dynamic Tissue Optimization technology, Dynamic TCE™ tissue contrast enhancement technology, SieScape™ panoramic imaging, SieClear™ multi-view spatial compounding and Clarify™ vascular enhancement (VE) technology for greater diagnostic confidence.
• Enhance productivity through application specific imaging presets, TGO™ tissue grayscale optimization technology, enhanced
measurement and report functionality, knowledge-based workflow tools including syngo® Auto OB measurements, syngo® Mitral Valve Assessment (MVA), syngo® Auto Left Heart (Auto LH), syngo® Velocity Vector Imaging™ (VVI) technology, Axius™ edge assisted Ejection Fraction, QuikStart rapid boot and standardized imaging protocols.
• Streamline connectivity with solutions such as DICOM Print/Store, DICOM Modality Worklist, DICOM MPPS and DICOM structured reporting for OB/GYN, Vascular and Cardiac exams.
• Increase functionality with fourSight™ 4D transducer technology, Advanced fourSight™ technology, integrated stress echo, syngo® fourSight™ TEE View, syngo® Arterial Health Package (AHP), ACUSON AcuNav™ ultrasound catheters, Live Bi-Plane for prostate imaging and Cadence™ contrast agent imaging technology*.

User Interface

• On-screen text, control panel overlay and operating instructions are available in the following languages:
* At the time of publication, the U.S Food and Drug Administration has cleared ultrasound contrast agents only for use in LVO. Check current regulations for the country in which you are using this system for contrast agent clearance.
4
- Chinese
• Wheels
- English
- French
- Italian
- German
- Spanish
• Russian keyboard and operating instructions supported
• Operating instructions are available in 17 additional languages
• Thumbnail menu provides on-screen thumbnail images and dynamic clips during exams
• On-screen acoustic power indicator (AIUM/NEMA output display standard)

Control Panel

• Home base layout
• User-centric control panel
• Backlit key illumination
• Variable key brightness indicates active functions
• Multi-level task light: ON, 1, 2, 3, OFF
- Castor size: 125 mm
- Front castor (2 ea): Bi-brake system (direction lock and total lock)
- Rear castor (2 ea): Total lock

Monitor

1
• Flat Panel Display (LCD), 18-inch color, high resolution, and progressive scan (non-interlaced) with In Plane Switching (IPS) technology
• Resolution: 1024 x 768 pixels
• Total screen area: 1400 x 900 pixels
• Recordable image area clips: 800 x 600 pixels
• Total screen capture: 1200 x 900 pixels
• Monitor tilt: 10° up, 70° down and swivel of ±90°
• Digital on-screen display of brightness and contrast controls
• Energy saving display power management
• (4) illumination controls including menu, increase, decrease and light
• Integrated high performance audio speakers
• Customizable soft keys for easy and immediate viewing of on-screen menus
• Full-size QWERTY keyboard supports text entry, function keys and system programming
• Wrist support to help reduce operator repetitive stress injuries

System

• Height adjustment of control panel: 100 mm
• Up/down with lock lever
• Multi-directional articulating monitor arm to help improve ergonomics
- Arm rotation: -90° to +90°
- FPD rotation: -80° to +80°
- Tilt: -10 to +65°
- Up: 125 mm
- Pull: 250 mm
1
Shipments to Brazil are delivered with
• Flat Panel Display (LCD), 17-inch color, high resolution, and progressive scan (non-interlaced) with In Plane Switching (IPS) technology
• Resolution: 1024 x 768 pixels
• Total screen area: 1280 x 1024 pixels
• Recordable image area clips: 800 x 600 pixels
• Total screen capture: 1280 x 960 pixels
• Monitor tilt: 10° up, 65° down and swivel of ±80°
• Digital on-screen display of brightness and contrast controls
• Energy saving display power management
• (4) illumination controls including menu, increase, decrease and light
• Integrated high performance audio speakers
5

TRANSDUCER TECHNOLOGY

Ultra-sensitive, wideband transducers, matched with user-selectable MultiHertz™ multiple frequency imaging, improve resolution and penetration. Up to seven 2D and THI frequencies and up to two color Doppler and spectral Doppler frequencies expand the clinical versatility of a single transducer, thereby maximizing transducer investment.
• Innovative ultra low-loss lens materials and microelectronic technologies for efficient performance and increased signal bandwidth
• microCase™ transducer miniaturization technology and SuppleFlex cables
• SuppleFlex™ transducer cables and integrated cable management provide protection during exams and transport
• Independent 2D and color frequencies for optimal resolution and penetration
• Frequency range: 1.2 – 13 MHz
• Hanafy lens acoustic technology
• Single crystal piezoelectric design
• Universal, stainless steel and disposable biopsy guides for specified linear and curved array transducers
• Speciality stainless steel and disposable needle guide attachments for the BP9-4 transducer with Live Bi-Plane

Specialty Transducers

The ACUSON X300 PE supports a range of transducers and capabilities, including intra­operative, TEE and Intracardiac Echocardiography transducers. For more detailed transducer information, please consult the Transducer Flyer.

Intracardiac Echocardiography Transducers

• ACUSON AcuNav 10F ultrasound catheter – Adult intracardiac echocardiography
• ACUSON AcuNav 8F ultrasound catheter – Adult intracardiac echocardiography
• CartoSound™ Communication – Adult intracardiac echocardiography with SoundStar™ 3D catheter
+
For purchase or inquires, contact Biosense Webster: USA
(1-909-839-8500 and 1-800-729-9010), Belgium (+32-2-352-
1411)
Note: See dedicated transducer flyer for more information.
+

Transducer Ports

• (3) active transducer ports that support high density phased array, curved array and linear array transducers
• Electronic transducer selection (instantaneous switching between transducers)
• Leftmost transducer port supports specialty transducers including the TEE transducer using micro-pinless (MP) adapter, mechanical 3D/4D transducer and Live Bi-Plane transducer
• Industrial design provides easy access to the transducer ports

Transducer Storage

• (6) configurable transducer holders support all transducer designs and provide gel bottle storage
• Special transducer holder provides secure storage and easy access to endocavity transducer
• Transducer holders can be removed for cleaning
• Optional side pocket storage for (1) transducer connector and (1) standard gel bottle

Hard Drive

• Internal 160 GB hard drive
• Allows storage of patient studies that include images, clips, reports and measurements
• Image storage capacity up to 150,000 images with compression (B/W and color)
• For more detailed information, please consult the Digital Patient Study Storage and Archiving section on page 14
6

Physiological Interface

DISPLAY MODES

• Standard 3-lead ECG interface
• Auxillary Input for ECG and other physiology signals from third party devices
• Continuous display in all real-time modes
• R-Wave single and dual trigger function
• Respiratory trace
• Heart rate display
• Adjustable gain and trace position on-screen
• Recovery Time: Less than 2 seconds

OPERATING MODES

2D
• Fundamental 2D
• Phased THI
• Filtered THI

Color

• Velocity-based color Doppler
• Power Doppler
• Directional power Doppler
• Color M-mode
• Color Doppler tissue imaging

Spectral Doppler

• Pulsed wave
• Steerable continous wave (SCW)
• Continuous wave – pencil probe
• Spectral Doppler tissue imaging
• Duplex and Triplex modes

M-mode

• Color M-mode
• Anatomical M-mode
• ECG trace in all modes
• Selectable split screen display formats in 2D or 2D/color with M-mode and/or spectral Doppler mode: top-bottom or side-by-side in real-time and digital cine replay
• 4B-mode allowing simultaneous display of 4 static B-mode images
• Virtual Format
• Dual from freeze
• Split/Zoom
• Live Bi-Plane
Flexible combination of imaging modes in side-by­side Dual and Dual Select in real-time, and digital cine replay.

2D-mode Image Processing

• All-digital parallel signal processing with frame rates up to 1172 fps (transducer dependent)
• MultiHertz imaging: Up to 7 user-selectable transmit frequencies
• Res/Speed selection: 6 levels
• Persistence: 5 levels
• Edge enhancement: 4 levels
• Dynamic range selection: 30 – 90 dB in 5 dB increments
• Gain: 0 – 60 dB in 1 dB increments
• DTO technology: 3 levels
• Dynamic TCE technology: 3 levels
• Depth/Gain Compensation: 8 controls
• User-selectable gain balance: 9 maps
• User-selectable 2D colorization: 16 maps
• Maximum Display Depth: 30 cm
• Minimum Display Depth: 2 cm
7

MultiHertz Multiple Frequency Imaging

• Higher image resolution at depth
Siemens’ unique MultiHertz multiple frequency imaging is designed to combine the resolution and penetration of several transducers into one. At the push of a button, the user can independently change frequencies for 2D, THI, color and spectral Doppler to select the optimal combination for image resolution, penetration and sensitivity.
• Transmit frequencies: Up to 7 user-selectable frequencies
- 2D and M-mode: Up to 4 frequencies
- THI: Up to 5 frequencies
- Color, power, or pulsed wave Doppler modes: Up to 2 frequencies
- SCW Doppler mode: 1 frequency

Tissue Harmonic Imaging (THI)

Selectable harmonic frequencies increase success with difficult-to-image patients, improving diagnostic confidence, and dramatically improving contrast and spatial resolution by reducing noise and clutter in the image.
• MultiHertz multiple frequency imaging capability in THI
• User can turn SynAps technology On and Off

2D Image Display

• Full screen, Split, Quad and Dual Select screen formats as well as Dual, Dual seamless, Dual select and Dual from Freeze
• Curved Vector format
• L/R flip and U/D flip for all formats in real-time and digital cine replay
• Split/Zoom
• Image depth: 2 – 30 cm in 1.0 cm increments (transducer dependent)
• Virtual Format Imaging (transducer dependent)
- Left/right steer
- Trapezoid Imaging
• Digital read/write Zoom with image pan
- Available on live and cine replay images
- At least 2.5x and up to 10x zoom (transducer dependent)
• 4B-mode
• Live Bi-Plane: Displays both longitudinal and transverse views simultaneously in real-time 2D imaging (transducer dependent)
• Available on the BP9-4, CH5-2, C6-2, C7F2, C8-5, P8-4, P4-2, P5-1, EC9-4, EV9-4, EV9F4, P9-4, VF8-3, VF10-5, VF13-5SP, VF13-5 and V5M transducers

Focusing

• Transmit focal zones: Up to 4 zones
• Digital dynamic receive focusing with dynamic apodization
• Multi-position, user-selectable position
• Can use multiple focal zones simultaneously

SynAps Synthetic Aperture Technology

• SynAps™ synthetic aperture technology is available on the CH5-2, C6-2, C7F2, C8-5, VF8-3 and VF10-5 transducers
8
• 90° image rotation (all linear transducers)

2D Calipers – Generic Measurements and Calculations

• Multiple cursor sets on frozen, live, dual screen and cine playback images
• Distance measurements: Up to 8 measurements per screen
- Distance measurement
- Depth measurement from skin line
- Angle measurement
- Area and circumference: ellipse, trace
• Compound Measurements
- Volume: user-selectable preset by 1 distance, 2 distance, 3 distance, or 1 ellipse and 1 distance
Loading...
+ 18 hidden pages