Siemens RF350M02X, RF350M02 User Manual

0 (0)

SIMATIC Ident

RFID systems SIMATIC RF350M

Operating Instructions

11/2015

C79000-G8976-C416-01

Introduction

Safety notes

Description

Commissioning

Operation

"RF350M" software

Advanced functions

Technical data

Ordering data

Appendix

1

2

3

4

5

6

7

8

9

A

Legal information

Warning notice system

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.

DANGER

indicates that death or severe personal injury will result if proper precautions are not taken.

WARNING

indicates that death or severe personal injury may result if proper precautions are not taken.

CAUTION

indicates that minor personal injury can result if proper precautions are not taken.

NOTICE

indicates that property damage can result if proper precautions are not taken.

If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.

Qualified Personnel

The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.

Proper use of Siemens products

Note the following:

WARNING

Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.

Trademarks

All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.

Disclaimer of Liability

We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.

Siemens AG

C79000-G8976-C416-01

Copyright © Siemens AG 2015.

Division Process Industries and Drives

05/2016 Subject to change

All rights reserved

Postfach 48 48

 

 

90026 NÜRNBERG

 

 

GERMANY

 

 

Table of contents

1

Introduction .................................................................................................................................................

5

2

Safety notes.................................................................................................................................................

7

3

Description

..................................................................................................................................................

9

 

3.1

Field of application and features....................................................................................................

9

 

3.2

Keyboard overview...........................................................................................................................

11

 

3.3

Antenna and antenna field.............................................................................................................

12

4

Commissioning.........................................................................................................................................

15

 

4.1

Power supply.....................................................................................................................................

15

 

4.1.1

Inserting the battery ........................................................................................................................

15

 

4.1.2

Connecting the charging/docking station...................................................................................

16

 

4.1.3

Charging the device.........................................................................................................................

17

 

4.1.4

The backup battery..........................................................................................................................

18

 

4.2

Scope of delivery handheld............................................................................................................

18

 

4.3

Components of the charging/docking station............................................................................

19

 

4.4

Switching the device On and Off ..................................................................................................

19

 

4.5

Basic settings in the operating system .......................................................................................

20

 

4.5.1

Control Panel ....................................................................................................................................

20

 

4.5.1.1

Control Panel ....................................................................................................................................

20

 

4.5.1.2

Accessing the Control Panel..........................................................................................................

20

 

4.5.1.3

Opening/closing applets.................................................................................................................

20

 

4.5.1.4

Closing the Control Panel...............................................................................................................

21

 

4.5.1.5

Control Panel applets......................................................................................................................

21

 

4.5.1.6

Power Management (PM)..............................................................................................................

31

5

Operation ..................................................................................................................................................

 

35

 

5.1

The keypad........................................................................................................................................

35

 

5.1.1

Activator key (OK)............................................................................................................................

36

 

5.1.2

Cursor keys........................................................................................................................................

36

 

5.1.3

Tab key...............................................................................................................................................

36

 

5.1.4

Alt key.................................................................................................................................................

36

 

5.1.5

Delete key..........................................................................................................................................

36

 

5.1.6

Cancel / Esc key...............................................................................................................................

36

 

5.1.7

Scan key.............................................................................................................................................

37

 

5.1.8

Alphanumeric keypad / function keys .........................................................................................

37

 

5.1.9

On / Off key.......................................................................................................................................

37

 

5.2

The touchscreen...............................................................................................................................

39

 

5.2.1

Stylus and touchscreen ..................................................................................................................

39

 

5.2.2

Screen keypad ..................................................................................................................................

40

SIMATIC RF350M

3

Operating Instructions, 11/2015, C79000-G8976-C416-01

Table of contents

6

"RF350M" software..................................................................................................................................

41

 

6.1

Starting "RF350M" software ...........................................................................................................

41

 

6.2

Menu overview and functions ........................................................................................................

42

 

6.3

The functions in the "Inventory" menu ........................................................................................

43

 

6.4

The functions in the "Tag Editor" menu .......................................................................................

45

 

6.5

The functions in the "Tag Info" menu ..........................................................................................

49

 

6.6

The functions in the "Settings" menu ..........................................................................................

50

 

6.7

The "Help" menu ...............................................................................................................................

54

7

Advanced functions.................................................................................................................................

55

 

7.1

Saving identified transponders ......................................................................................................

55

 

7.2

Data transfer between the PC and mobile reader .....................................................................

56

 

7.2.1

Prerequisites ......................................................................................................................................

56

 

7.2.2

Windows Mobile Device Center .....................................................................................................

56

8

Technical data..........................................................................................................................................

57

9

Ordering data............................................................................................................................................

59

A

Appendix

...................................................................................................................................................

61

 

A.1

Certificates and approvals ..............................................................................................................

61

 

A.2 .............................................................................................................................

Service & Support

64

4

SIMATIC RF350M

Operating Instructions, 11/2015, C79000-G8976-C416-01

Introduction

1

Purpose of this document

These operating instructions contain information required for commissioning and using the SIMATIC RF350M device.

The documentation is intended for commissioning engineers and machine operators who start up the application themselves and it describes the functions of the software.

Scope of validity of this document

This documentation is valid for the SIMATIC RF350M mobile reader and describes the delivery status as of 11/2015.

Registered trademarks

SIMATIC ®, SIMATIC NET®, SIMATIC RF ® and MOBY ® are registered trademarks of Siemens AG.

Naming conventions

The following terms/abbreviations are used synonymously in this document:

Mobile reader

Reader, read/write device (SLG), hand terminal,

 

handheld

Transponder

Tag, mobile data storage (MDS), data carrier

History

Previous editions of these operating instructions:

Edition

Note

11/2015

First edition

SIMATIC RF350M

5

Operating Instructions, 11/2015, C79000-G8976-C416-01

Safety notes

2

SIMATIC RFID products comply with the salient safety specifications to VDE/DIN, IEC, EN, UL and CSA. If you have questions about the validity of the installation in the planned environment, please contact your service representative.

NOTICE

Forfeiture of approvals and guarantees

Alterations to the devices are not permitted.

Failure to observe this requirement shall constitute a revocation of the radio equipment approval, CE approval and manufacturer's warranty.

Repairs

WARNING

Repairs only by authorized qualified personnel

Unauthorized opening of and improper repairs to the device may result in substantial damage to equipment or danger. Repairs may only be carried out by authorized qualified personnel.

SIMATIC RF350M

7

Operating Instructions, 11/2015, C79000-G8976-C416-01

Description

3

SIMATIC RF350M expands the RF200 and RF600 identification systems with a powerful mobile reader for applications in the areas of production and service. In addition, it is an indispensable aid for startup and testing.

3.1Field of application and features

Device variants for different frequency ranges

The SIMATIC RF350M device is available in the following variants:

with internal antenna

with connector for external antennas

Implementation environment, field of application and features

Field of application

The SIMATIC RF350M mobile reader can be used in a harsh environment. The device is extremely rugged and protected against spray water. The backlit display is easy to read even under unfavorable lighting conditions.

RFID system

The SIMATIC RF350M mobile reader is intended specifically for the SIMATIC RF200 and RF300 RFID systems. The device can be used to process all RF300 transponders and ISO transponders compatible with it.

Transponder standards

The device supports the following transponder standards

RF300

ISO 15693

Software

The "RF350M" software is stored in non-volatile memory on an integrated flash disk and permits user-friendly, distributed reading and writing of all transponders named above.

SIMATIC RF350M

9

Operating Instructions, 11/2015, C79000-G8976-C416-01

Description

3.1 Field of application and features

Functions of the RF550M

You can perform the following functions with the SIMATIC RF350M mobile reader:

Read tag ID (UID)

Read data from the transponder

Write data to the transponder

Represent and edit the data in hexadecimal and ASCII format

Save and load transponder data to and from a file

Inventory log file for UID

Menu prompting in English and German (switchable)

Password protection for writing transponders and ending the program (parameters can be assigned)

For more information, refer to the section "The functions in the "Tag Editor" menu (Page 45)".

Accessories

The charging station for recharging the batteries and the connection to PCs via a USB interface or Ethernet must be ordered separately. This station has a charging bay for an additional spare battery. You will find more information on this subject in the section "Ordering data (Page 59)".

10

SIMATIC RF350M

Operating Instructions, 11/2015, C79000-G8976-C416-01

Siemens RF350M02X, RF350M02 User Manual

Description 3.2 Keyboard overview

3.2

Keyboard overview

 

 

Table 3- 1 Keypad overview of the SIMATIC RF350M

 

 

SIMATIC RF350M

Pos.

Key label

 

 

 

LED charge indicator

 

 

 

Activator key (OK)

 

 

 

Tab key

 

 

 

Circle key

 

 

 

123 key

 

 

 

Shift key

 

 

 

Alt key

 

 

 

Scan key

 

 

 

Delete key

 

 

 

Cancel / Esc key

 

 

 

Cursor keys

 

 

 

Screen key

 

 

 

F key

 

 

 

Abc key

 

 

 

Alphanumeric keypad / function keys

 

 

 

On / Off key

SIMATIC RF350M

11

Operating Instructions, 11/2015, C79000-G8976-C416-01

Description

3.3 Antenna and antenna field

3.3Antenna and antenna field

Read head with integrated antenna (6GT2803-1BA00)

The antenna is housed in the read head under a cover.

Figure 3-1 Read head with integrated antenna

Direction of propagation of the radio frequency field

The read/write area for transponders is above and below the front part of the housing. Transponders cannot be processed from the front end.

The figure below shows the direction of propagation of the RF field of the antenna.

Figure 3-2 Propagation of the RF field

12

SIMATIC RF350M

Operating Instructions, 11/2015, C79000-G8976-C416-01

Description 3.3 Antenna and antenna field

Read head with the option of connecting an external antenna (6GT2803-1BA10)

The external antenna is connected via the antenna connector on the read head .

Figure 3-3 Read head with the option of connecting an external antenna

The following antennas can be connected to the RF350M reader with integrated RFID write/read unit and external antenna connector using an antenna connecting cable:

ANT 3

ANT 8

ANT 12

ANT 18

ANT 30

You will find detailed information on the antennas and the write/read ranges of the antennas in the RF300 system manual.

SIMATIC RF350M

13

Operating Instructions, 11/2015, C79000-G8976-C416-01

Commissioning

4

4.1Power supply

4.1.1Inserting the battery

The battery of the SIMATIC RF350M is located on the rear of the device. The following instructions describe inserting the battery in the device

Table 4- 1 Inserting the battery

 

Step Picture

Description

1.

Release the hook and loop fastener on the battery

 

cover on the rear of the device and open the screw

 

below.

2.

Raise the battery cover on the screw side and remove

 

the cover.

3.

Insert the battery. Make sure that you insert the bat-

 

tery at an angle so that the contact side of the bat-

 

tery is inserted into the battery compartment first.

4.

Hook the battery cover and close it. Secure the the

 

battery cover with the screw and close the hook and

 

loop fastener.

SIMATIC RF350M

15

Operating Instructions, 11/2015, C79000-G8976-C416-01

Commissioning 4.1 Power supply

4.1.2Connecting the charging/docking station

Close the charging/docking station as shown in the following figure.

Power supply (5 VDC) Ethernet

Mini-USB

Figure 4-1 Connecting the charging station of the RF350M

You can use charging/docking station to:

charge the SIMATIC RF350M mobile reader,

charge a spare battery and

connect the reader to the PC.

16

SIMATIC RF350M

Operating Instructions, 11/2015, C79000-G8976-C416-01

Commissioning 4.1 Power supply

4.1.3Charging the device

Complete charging of an empty battery takes approximately 5 hours.

Starting the charging operation

The charging operation is started as soon as you insert the mobile reader into the charging station.

WARNING

Explosion hazard when using a different charging station

Use only the original charging station. Use of another charging station can result in explosions and serious personal injury.

Detecting the level of charge

When the mobile reader is in the charging station, the charging status of the device is indicated by the LED charging display of the reader:

LED charge indicator

Figure 4-2 LED display of the reader

Table 4- 2 LED charge indicator

LED color

Meaning

red

Charge level ≤ 90%; charging active

Orange

Charge level ≥ 90%; charging active

Green

Charge level = 100%

With the charging station, you can also charge a spare battery.

SIMATIC RF350M

17

Operating Instructions, 11/2015, C79000-G8976-C416-01

Commissioning

4.2 Scope of delivery handheld

The LED charging display of the charging station indicates the charge status of the spare battery.

LED charge indicator

Figure 4-3 LED display of the charging station

4.1.4The backup battery

The backup battery in the SIMATIC RF350M is used to retain the application data when the main battery is empty. It is a rechargeable battery that is charged along with the main battery.

Please note that the backup battery (in the case of an empty or removed main battery) can only retain the data for a few minutes. It cannot be replaced because it is permanently connected to the device.

4.2Scope of delivery handheld

When supplied, the SIMATIC RF350M comprises the following components:

SIMATIC RF350M mobile reader

Battery

Hand strap

Input stylus as an aid to navigation on the touchscreen

18

SIMATIC RF350M

Operating Instructions, 11/2015, C79000-G8976-C416-01

Commissioning 4.3 Components of the charging/docking station

4.3Components of the charging/docking station

The charging and docking station is made up of the following components:

Charging and docking station

Power supply unit including various connecting cables for EU / UK / US

USB cable

4.4Switching the device On and Off

Requirements for startup

The battery of the reader is charged and inserted as described in the section "Power supply (Page 15)".

Note

Keep to the minimum charging time

Before switching the device on for the first time, you must insert the reader into the charging unit and charge it for approximately five hours.

Switching the device on/off

To switch the reader on or off, press the On/Off button . After switching on, the power-up takes a few seconds.

Automatic shutdown of the device

The RF350M mobile reader has an automatic suspend mode to save energy. With this, the reader is changed to the following power statuses step-by-step:

Table 4- 3 Factory settings: Power statuses of the reader

 

Power status

Mains power operation:

Battery operation

User Idle

1 minute

1 minute

System Idle

5 minutes

2 minutes

Suspend

--

5 minutes

After being switched on again, the reader starts in the last active menu entry.

You can manage the energy statuses with "Start > Settings > Control Panel > Power". For a detailed description of the power statuses, refer to the section "Power Management (PM) (Page 31)".

SIMATIC RF350M

19

Operating Instructions, 11/2015, C79000-G8976-C416-01

Commissioning

4.5 Basic settings in the operating system

4.5Basic settings in the operating system

As the operating system the RF350M mobile reader uses "Microsoft Windows CE V6.0". The following sections describe the setting options of the operating system.

4.5.1Control Panel

4.5.1.1Control Panel

The Control Panel contains a collection of applets to be able to access the settings of various system properties, to configure these properties, to change their performance characteristics and to enable or disable them.

4.5.1.2Accessing the Control Panel

You can access the Control Panel either via the keyboard or using the touchscreen. The following instructions relate to access via the keyboard. Before you begin close all application windows on the screen.

To open the Control Panel, follow the steps below:

1.Press the Tab key so that the input focus is set on the start menu symbol to the left in the taskbar in the lower left area of the screen.

2.Press the Activator button to open the start menu.

3.Select the menu command "Settings" with the cursor keys.

4.Press the right arrow of the cursor keys ring to open the "Settings" submenu.

5.Select the menu command "Control Panel" with the cursor keys.

6.Press the Activator key to open the Control Panel.

4.5.1.3Opening/closing applets

Opening applets

To open applets, follow the steps below:

1.Select the required applet using the cursor keys.

2.Press the activator button to open the applet.

Closing applets

To close the applet and its window, you have two options:

If you want to discard changes made to the configuration, press the Cancel/Esc key.

If you want to adopt changes you have made, press the activator key.

20

SIMATIC RF350M

Operating Instructions, 11/2015, C79000-G8976-C416-01

Loading...