Technical Data RF260R – Short Form
Remarks: The RF260R manual does not yet exist, even in German language. The RF260R manual, once completed, will contain detailed information about field-data, range for certain tags, information about how to implement the RF260R in a production site with communication modules. This detailed information may not be much relevant for RF260R FCC approval. Below given are short system overview and technical data which are required in order to run the RF260R for testing and to check the reader’s function.
RF200 System overview
SIMATIC RF200 is an inductive identification system, based on the standard ISO 15693, which was specially designed for industrial production for controlling and optimization material flow. Contrary to SIMATIC RF300, SIMATIC RF200 is designed for RFID applications for lower demands on performance (data volume, data transfer speed, diagnostics). SIMATIC RF200 is a low-price RFID system.
Component Description
Communications Modules Integration of an RFID Identification system is achieved by a
communications module.
Reader The reader achieves the communication with the tag and provides the tag
with energy by the reader’s magnetic field. The reader also interfaces to various modules (i.e. SIMATIC S7 via ASM 475).
Tag The RFID-tag stores all data relevant for production and is used as a
substitute for optical barcode-tags.
Overview of System Components compatible with RF260R
System components
Communications modules
Tags
ASM 456
ASM 475 (S7 300/ ET 200M)
RF160C
RF170C
RF180C
RF182C
MDS D100
MDS D200
MDS D124
MDS D139
MDS D160
MDS D324
MDS D421
MDS D424
MDS D428
MDS D460
Technical Data RF260R (short form)
Inductive interface (magnetic field) to transponder (tag). Carrier frequency for energy / data
Antenna Integrated loop
Interface to communications module RS422
Baud rate 19200, 57600, 115200 Baud
Functions Initialize tag, read tag, write on tag, get status data,
DC-Voltage (nominal) 24 V DC
Display elements 2-color-LED
Connector M12 (8-pin.)
Housing
Dimensions (in mm)
Color
Material
13,56 MHz
antenna on/off, read tag serial number
(operating voltage, presence, error)
75 x 75 x 41 (without M12 device connector)
anthracite
PA6.6-GF35 (Ultramid A3WG7)
Fixing 2 Screws, M5 type
Degree of protection to EN 60529
Weight 200 g
Current consumption 40mA
IP67