Technical Data RF210R-IO-Link – Short Form
Remarks: A released RF210R-IO-Link manual does not yet exist. The RF210R-IO-Link
manual, once completed, will contain detailed information about field-data, range for
certain tags and information about how to implement the RF210R in a production site
with communication modules. This detailed information may not be much relevant for
RF210R-IO-Link FCC approval.
Below given are short system overview and technical data which are required in order to
run the RF210R-IO-Link for testing and to check the reader’s function.
RF200 System overview
SIMATIC RF200 is an inductive identification system, based on the standard ISO 15693,
which was specially designed for industrial production for controlling and optimization
material flow.
Contrary to SIMATIC RF300, SIMATIC RF200R-IO-Link is designed for RFID
applications for lower demands on performance (data volume, data transfer speed,
diagnostics). SIMATIC RF200R-IO-Link is a low-price RFID system.
Overview of System Components compatible with RF210R-IO-Link
System
System components
SystemSystem
Communications modules
components Description, Examples
componentscomponents
Description, Examples
Description, ExamplesDescription, Examples
IO-Link readers are designed to
operate along with an IO-Link Master
• IO-Link Master via Profibus,
Profinet or S7-Systembus.
• IO-Link Implementation available
for Profibus, Profinet, Interbus, ASi, EtherCAT, Powerlink.
• IO-Link Master: ET 200eco PN
• IL-Link Master: ET200S
• IO-Link Master: 00S 4SI IO-Link
• IO-Link Master for fieldbus
Tags
(suitable for RF210R-IOLink)
• MDS D124
• MDS D160
• MDS D324
• MDS D421
• MDS D422
• MDS D424
• MDS D425
• MDS D428
• MDS D460
Modes of Operation (IO-Link Modes)
Standard-Input-Output (SIO)-Mode:
Tag presence only. No communication between reader and IO-Link master
IO-Link Mode 1 (Scan UID):
Tag presence, Tag-UID read (no external parametrization required)
IO-Link Mode 2:
Low-level parametrization required, Tag-read only.
IO-Link Mode 3:
Higher level parametrization required, Tag read / Tag write, communication module
required.