Read/Write Devices
5.6SLG 42
Application area The SLG 42 is a middle-of-the-line read/write device. With its larger antenna, the SLG 42 generates a much larger field than the SLG 41, and a greater range can be achieved with the same data memories. In dynamic operation, larger amounts of data can be read from and written to the MDS. See chapter 3.4.
Ordering data
Technical data
Figure 5-23 SLG 42 read/write device |
|
|
||
Table 5-14 |
Ordering data for SLG 42 |
|
|
|
|
|
|
||
Read/write device SLG 42 |
|
6GT2 001-0BA00 |
||
up to 70 mm (medium power) |
|
|
||
SLG plug connector and stub lines |
|
See chapter 3.10 |
||
|
|
|
|
|
Table 5-15 |
Technical data of SLG 42 |
|
|
|
|
|
|
||
Inductive interface to MDS |
|
|
||
Data transmission speed |
19200 baud |
|||
Read/write distance |
|
|
||
SLG to MDS (max.) |
70 mm (see field data table) |
|||
Transmission frequency |
|
|
||
|
Power |
|
134 kHz |
|
|
Data |
|
1.81 MHz |
|
|
|
|||
Serial interface to ASM |
6-pin SLG plug connector in acc. w. |
|||
|
|
|
DIN 43651 |
|
Transmission speed |
19200 baud, RS 422 |
|||
|
|
|||
Line length, ASM to SLG (max.) |
120 m |
|||
at 24 V DC |
|
|
|
|
|
|
|
||
Supply voltage (via serial interface) |
|
|
||
Nominal value |
|
24 V DC |
||
|
|
|||
Permissible range |
20 to 30 V DC |
|||
Current consumption |
|
|
||
Idle/operation |
|
60 mA/180 mA |
||
|
|
|
||
MTBF |
|
2 x 106 |
MOBY I Configuration, Installation and Service Manual |
5-21 |
(4) J31069-D0033-U001-A8.1-7618 |
Read/Write Devices
|
|
Table 5-15 |
Technical data of SLG 42 |
|
|
|
|
|
|
|
|
|
|
Housing |
|
|
|
|
|
Dimensions in mm (W x H x D) |
75 x 40 x 75 |
||
|
|
Color |
|
Gray |
|
|
|
|
|||
|
|
Material |
|
Polyamide 12 |
|
|
|
|
|
|
|
|
|
Plug connection |
DIN 43651 |
||
|
|
Protection rating |
IP65 |
||
|
|
Shock |
|
50 g |
|
|
|
Vibration |
|
20 g |
|
|
|
|
|
|
|
|
|
Mounting of SLG |
4 M5 screws |
||
|
|
Turning moment (at room temperature) |
v 2 Nm |
||
|
|
Ambient temperature |
|
|
|
|
|
During operation |
±25° to +70° C |
||
|
|
During transportation and storage |
±40° to +85° C |
||
|
|
|
|
|
|
|
|
Weight (approx.) |
250 g |
||
|
|
|
|
|
|
|
|
Silicon free |
|
Yes |
|
Field data |
|
|
|
||
The exact field data depend on the type of MDS used. |
|||||
|
|
Table 5-16 |
Field data of SLG 42 |
|
|
|
|
|
|
|
|
|
|
Operating distance (Sa) |
0 to 55 mm |
||
|
|
Limit distance (Sg) |
70 mm |
||
|
|
Median deviation (L) |
Depends on MDS |
||
|
|
Minimum distance from SLG to SLG (D) |
> 800 mm |
||
FCC information |
|
|
|
|
|
|
|
|
|
|
|
|
Made in Germany |
|
|
||
|
|
|
|
SIEMENS MOBY I SLG 42
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO
THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
UNDESIRED OPERATION.
Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
5-22 |
MOBY I Configuration, Installation and Service Manual |
(4) J31069-D0033-U001-A8.1-7618 |