Siemens MOBYI-SLG42N Users Manual

Read/Write Devices

5.6SLG 42

Application area The SLG 42 is a middle-of-the-line read/write device. With its larger antenna, the SLG 42 generates a much larger field than the SLG 41, and a greater range can be achieved with the same data memories. In dynamic operation, larger amounts of data can be read from and written to the MDS. See chapter 3.4.

Ordering data

Technical data

Figure 5-23 SLG 42 read/write device

 

 

Table 5-14

Ordering data for SLG 42

 

 

 

 

 

Read/write device SLG 42

 

6GT2 001-0BA00

up to 70 mm (medium power)

 

 

SLG plug connector and stub lines

 

See chapter 3.10

 

 

 

 

Table 5-15

Technical data of SLG 42

 

 

 

 

 

Inductive interface to MDS

 

 

Data transmission speed

19200 baud

Read/write distance

 

 

SLG to MDS (max.)

70 mm (see field data table)

Transmission frequency

 

 

 

Power

 

134 kHz

 

Data

 

1.81 MHz

 

 

Serial interface to ASM

6-pin SLG plug connector in acc. w.

 

 

 

DIN 43651

Transmission speed

19200 baud, RS 422

 

 

Line length, ASM to SLG (max.)

120 m

at 24 V DC

 

 

 

 

 

 

Supply voltage (via serial interface)

 

 

Nominal value

 

24 V DC

 

 

Permissible range

20 to 30 V DC

Current consumption

 

 

Idle/operation

 

60 mA/180 mA

 

 

 

MTBF

 

2 x 106

MOBY I Configuration, Installation and Service Manual

5-21

(4) J31069-D0033-U001-A8.1-7618

Siemens MOBYI-SLG42N Users Manual

Read/Write Devices

 

 

Table 5-15

Technical data of SLG 42

 

 

 

 

 

 

 

 

 

 

Housing

 

 

 

 

 

Dimensions in mm (W x H x D)

75 x 40 x 75

 

 

Color

 

Gray

 

 

 

 

 

Material

 

Polyamide 12

 

 

 

 

 

 

 

Plug connection

DIN 43651

 

 

Protection rating

IP65

 

 

Shock

 

50 g

 

 

Vibration

 

20 g

 

 

 

 

 

 

 

Mounting of SLG

4 M5 screws

 

 

Turning moment (at room temperature)

v 2 Nm

 

 

Ambient temperature

 

 

 

 

During operation

±25° to +70° C

 

 

During transportation and storage

±40° to +85° C

 

 

 

 

 

 

 

Weight (approx.)

250 g

 

 

 

 

 

 

 

 

Silicon free

 

Yes

Field data

 

 

 

The exact field data depend on the type of MDS used.

 

 

Table 5-16

Field data of SLG 42

 

 

 

 

 

 

 

 

 

Operating distance (Sa)

0 to 55 mm

 

 

Limit distance (Sg)

70 mm

 

 

Median deviation (L)

Depends on MDS

 

 

Minimum distance from SLG to SLG (D)

> 800 mm

FCC information

 

 

 

 

 

 

 

 

 

 

 

Made in Germany

 

 

 

 

 

 

SIEMENS MOBY I SLG 42

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO

THE FOLLOWING TWO CONDITIONS:

(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST

ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE

UNDESIRED OPERATION.

Caution

Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

5-22

MOBY I Configuration, Installation and Service Manual

(4) J31069-D0033-U001-A8.1-7618

Loading...