Siemens MOBYD SLGD12, MOBYD SLGD10, MOBYD SLGD11 Users Manual

Page 1
Read/Write Devices
5
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-1
Page 2
Read/Write Devices
5.1 Introduction
5.1.1 SLG with RS 232 Serial Interface
Application area
Design and functions
In accordance with customer-specific requirements, the following variants are available:
S SLG D10 ANT D5
S SLG D11 ANT D5
S SLG D12
A robust housing and the high degree of protection (IP65) permit deployment in the most severe industrial environments.
The SLG is connected via a serial interface (RS 232) of the PC, which per­mits communication with PCs or external PLCs. Commands and the data to be written or read are converted via a modulator/demodulator circuit.
The amount of data that can be transferred between SLG and MDS depends on the following factors.
S The speed at which the MDS moves through the SLG’s transmission win-
dow (antenna)
S The length of the transmission window
Use of the C++ library permits the SLG to be programmed quickly using ap­plications under Windows 9x/2000 and NT 4.0.
Table 5-1 Table providing an overview of the SLG with an RS 232 serial interface
SLG Type
SLG D10 ANT D5 0 to 380 mm 450 mm –20 to +55 °C 320 x 145 x 100 340 x 325 x 38 IP65 SLG D11 ANT D5 0 to 240 mm 300 mm –20 to +70 °C 160 x 80 x 40 340 x 325 x 38 IP65 SLG D12 0 to 120 mm 150 mm –20 to +70 °C 160 x 80 x 40 IP65
Definition of IP65
– Protection against penetration of dust (i.e. dust-proof) – Full protection against touch – Protection against water jet
Working di-
stance S
(depending
on MDS)
5-2
a
Limit di­stance S
(depen­dent on
the MDS)
Temperature
a
range
(during opera-
SLG
dimensions
(L x W x H)
tion)
MOBY D Configuration, Installation and Service Manual
in mm
Antenna di-
mensions
(L x W x H)
in mm
(4) J31069-D0147-U001-A3-7618
Protec-
tion
rating
Page 3
Configuration SLG – MDS (via RS 232)
C library MDWAPI (The library permits the use of several serial interfaces at the same time)
PC
Read/Write Devices
RS 232 connecting cable 6GT2 691-0BH50 (6GT2 691-0BN20)
6GT2 080-2AA10 (MOBY Software)
Spacing kit 6GT2 690-0AB00 (accessories)
SLG D10 ANT D5 6GT2 601-0AA00
Label / Transponder
Figure 5-1 SLG – MDS configuration via RS 232
SLG D12
6GT2 601-0AB00
MOBY wide-range power pack 6GT2 494-0AA00
24 V connecting cable 6GT2 491-1HH50
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-3
Page 4
Read/Write Devices
Programming of the SLG D 10, SLG D 11, and SLG D 12
Communication at the serial interface between the SLG and the superordinate computer system (host) takes place by means of an asynchronous 8-bit binary protocol. The frames are secured by means of a CRC 16. Can be run on PC models as of the Pentium 2 processor with a serial inter­face and a Windows 9x/2000/NT 4.0 operating system.
The SLG is connected to a serial interface of the computer. Users work with the PC interfaces COM 1 and/or COM 2; 8 interfaces can be run with addi­tional hardware.
A 32-bit library (MDWAPI for Windows 9x/2000 and NT 4.0) and a pro­gramming guide are available to the user for programming (Software MOBY CD).
For computers that do not run under Windows (e.g. UNIX), the commu­nication specification is described in the programming guide (MDWAPI).
Parameter defaults
The configuration parameters are described in the programming guide (MDWAPI).
Table 5-2 Ordering data for the MOBY software
Order No.
MOBY Software 6GT2 080-2AA10
Note
on MOBY software and licensing
When you purchase an ASM or SLG interface module, this does not include software or documentation. The“Software MOBY” CD-ROM, which con­tains all the available FBs/FCs for SIMATIC, C libraries for Windows, demo programs, etc., can be ordered additionally.
The CD-ROM also includes the complete set of MOBY documentation (Ger­man, English, and in some cases French) in PDF format. When you purchase an ASM or SLG interface module, the price for use of the software including documentation on the ”Software MOBY” CD-ROM is included. The pur­chaser obtains the right to make copies (duplication license) as needed for customer applications or system development for the plant.
The enclosed contract also applies to the use of software products for a one-off charge.
5-4
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 5
Read/Write Devices
5.1.2 SLG with RS 422 for SIMATIC S7 and PROFIBUS-DPV1
Application area
Design and func­tions
The SLG D1xS provides inductive communication with the mobile data sto­rage units (MDSs) and the serial link to the interface modules (ASMs). Various SLGs – for short, medium, and long distances to the MDS – are avai­lable to meet customer requirements.
S SLG D10S ANT D5
S SLG D11S ANT D5
S SLG D12S
A robust housing and the high degree of protection (IP65) permit deployment in the most severe industrial environments.
The SLG executes commands received from the interface module. These commands and the data to be read or written are converted via an appropriate modulator/demodulator circuit. Communication between MDS and the SLG takes place via inductive alter­nating fields.
The amount of data that can be transferred between SLG and MDS depends on the following factors.
S The speed at which the MDS moves through the transmission window of
the SLG’s antenna
S The length of the transmission window
S The MDS type
Table 5-3 Table providing an overview of the SLG with an RS 422 interface
SLG Type
SLG D10S ANT D5 0 to 380 mm 450 mm –20 to +55 °C 320 x 145 x 100 340 x 325 x 38 IP65 SLG D11S ANT D5 0 to 240 mm 300 mm –20 to +70 °C 160 x 80 x 40 340 x 325 x 38 IP65
SLG D12S
1 Integrated antenna
Definition of IP65
– Protection against penetration of dust (i.e. dust-proof) – Full protection against touch – Protection against water jet
1
Working di-
stance S
(depending
on MDS)
0 to 120 mm 150 mm –20 to +70 °C 160 x 80 x 40 IP65
a
Limit di­stance S
(depen­dent on
the MDS)
Temperature
a
range
(during opera-
tion)
SLG
dimensions
(L x W x H)
in mm
Antenna di-
mensions
(L x W x H)
in mm
Protec-
tion
rating
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-5
Page 6
Read/Write Devices
5.1.3 Troubleshooting
What should you do if nothing works?
1. Check the supply voltage directly on the SLG connector using a measur­ing instrument.
2. Check the cabling to the PC
– Do the SLG and PC have the same physical interface?
– Is the polarity of the connecting cable correct (RS 232)?
– Is the cable shield applied correctly?
(RxD of the SLG must be connected to TxD of the PC and vice versa)
Error messages
SLG range too low
Error messages are described in the programming guide (MDWAPI).
If the SLG range is too low, check:
– The power supply unit/switched-mode power supply unit (see Sec-
tion 3.4 on electrical interference)
– Whether there are monitors or other sources of interference in the vi-
cinity (see Section 3.4)
– Whether there is metal in the immediate vicinity (see Section 3.3)
– To attain optimal read/write distances for the ANT D 5, a metal plate
is required at a distance of 100 mm (see Table 3-8 and 3-9).
5-6
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 7
5.2 SLG D10 ANT D5
Read/Write Devices
Application area
The SLG D10 ANT D5 is a high-performance read/write device with a serial interface and a separate antenna, designed specifically for storage, logistics, and distribution applications. It is designed for a range of up to 600 mm (de­pending on the label). The read/write device has an RS 232 serial interface (RS 422 interface on request), which permits communication with PCs or external PLCs.
For simple and rapid programming there is a C library available to the user that can be used under Windows 9x, 2000, and NT. The SLG D10 ANT D5 is multitag capable.
Figure 5-2 Read/write device SLG D10 ANT D5
Ordering data
Table 5-4 Ordering data for the SLG D10 ANT D5
Read/write device SLG D10 ANT D5
with an RS 232 serial interface for standard PCs, with a separate antenna
Accessories:
Spacer kit for ANT D5
MOBY wide-range power pack
Cables and connectors
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
Order No.
6GT2 601-0AA00
6GT2 690-0AB00
6GT2 494-0AA00
See Section 3.6
5-7
Page 8
Read/Write Devices
Technical data
Table 5-5 Technical data of the SLG D10 ANT D5
Inductive interface to MDS
Transmission frequency
Supported transponders
13.56 MHz
Transponder in accordance with ISO 15693 (e.g. I-Code, Tag-it, my-d)
Serial interface to user
Transmission protocol
Data transmission speed
RS 232 (RS 422 on request)
Asynchronous 8 bit
9600 bps to 115.2 kbps (adjustable)
Data backup
CRC 16
Output power 4 W
SLG - MDS read/write distances Typically 450 mm (see field data)
Software functions
MDS: Read, write, initialize, access rights, multitag
Programming
Windows 9x, 2000, and NT, with available 32-bit DLL
Multitag Ye s
Anti-collision speed Approx. 20 labels/s identifiable in
parallel
Power supply 24 VDC ±5%
Current consumption
Operation
Transient making current
0.9 A
2.8 A/50 ms
Line length, SLG – PC
With RS 232
With RS 422
Antenna line length
30 m
300 m
3.60 m
Digital inputs/outputs None
Housing
Dimensions (in mm)
For antenna [L x W x H]
For electronic components
[L x W x H]
Color Antenna
SLG housing
Material Antenna
340 x 325 x 38
320 x 145 x 100 (without connector)
Black
Anthracite
Plastic ASA
Aluminum
SLG housing
Connector
TNC connector
Antenna (can be connected to the SLG)
Mounting of SLG
Mounting of antenna
4 M6 screws
4 M5 screws
Ambient temperature
in operation in transit and storage
–20 °C to +55 °C –25 °C to +70 °C
1
5-8
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 9
Read/Write Devices
Table 5-5 Technical data of the SLG D10 ANT D5
Protection rating in accordance with EN 60529
SLG and antenna
Shock in accordance with EN 60721-3-7 Class 7M2
Total shock response spectrum type II
Vibration in accordance with EN 60721-3-7 Class 7M2
Weight, approx.
SLG
Antenna
Certifications Radio EN 300 330
1 To ensure optimal field data in a metallic environment, the ANT D5 is calibrated at the
factory at a distance of 100 mm from metal.
IP65
30 g
1 g (9 to 200 Hz)/
1.5 g (200 to 500 Hz)
3500 g
1000 g
CE
Safe for pacemakers
Caution
The antenna cable is prepared in advance. If the cable is changed, the war­ranty and CE marking become invalid.
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-9
Page 10
Read/Write Devices
Field data
Transmission window
Table 5-6 Field data of the SLG D10 ANT D5
Limit distance (S
) Max. 450 mm
g
(dependent on transponder)
Working distance (Sa) 0 to 380 mm
(dependent on transponder)
Length of the transmission window (Ld) 320 mm
Width of the transmission window (W) 128 mm Minimum distance from ANT D5 to ANT D5 2 m
L
d
1
Sa,
Sa,
min.
max.
S
Top view
g
1 At Sa,
Transmission window
ANT D5
Spacing kit
the transmission window increases
min
S
a
Figure 5-3 Transmission window with the SLG D10 ANT D5
S
100
g
Side view
Metal plate
5-10
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 11
Metal-free space
Read/Write Devices
Metal-free space with flush mounting
a = 150 mm
Metal
FCC information
a
a
h = 100 mm (non-metallic spacers)
a
Figure 5-4 Metal-free space for the SLG D10 ANT D5
Made in Germany
SIEMENS MOBY D SLG D10
FCC ID NXW-MOBYD-SLGD10
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO
FOLLOWING TWO CONDITIONS:
THE
THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
(1)
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
ACCEPT
UNDESIRED
OPERATION.
a
Caution
Any changes or modifications not expressly approved by the party responsi­ble for compliance could void the user’s authority to operate the equipment.
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-11
Page 12
Read/Write Devices
Definition of the distance D
D
D
Distance D 2 m
Figure 5-5 Distance D: SLG D10 ANT D5
5-12
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 13
Dimensions (in mm)
10
Read/Write Devices
Cable length 3.5 m
Minimal bending
320
radius: 20 mm
4 x 5.5
Anti-kink protection bendable in all directions
A
1
290
7
125
145
View A
100
25
25
52,5
31
60
7
Note:
The SLG must be grounded using the grounding screw provided.
Figure 5-6 Dimensioned drawing of the SLG D10 ANT D5
340
300
325
1
Note
In order to ensure optimal field data in surroundings where there is metal as well, the ANT D5 is calibrated at the factory at a distance of 100 mm from metal.
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-13
Page 14
Read/Write Devices
Spacing kit for the MOBY D ANT D5
Table 5-7 Ordering data for the spacing kit MOBY D ANT D5
Order No.
Spacing kit for the ANT D5 made of aluminum with plastic
6GT2 690-0AB00
spacers including fixing screws
Individual parts Quantity
Aluminum plate 380 x 380 x 2 1
Plastic bolts 100 x 20 4
Countersunk head screws M5 x 12 4
Cylinder head screws M5 x 15 4
Washer for M5 4
Spring lock washer for M5 4
Aluminum plate:
Plastic bolts:
10 R
300
280
100
6
T = 2
9
20
340
380
M5 x 20
Figure 5-7 Dimensioned drawing for the spacing kit for the MOBY D ANT D5
5-14
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 15
Read/Write Devices
4
5 6
2
Figure 5-8 Mounting diagram for spacer kit
1
3
Holes for ANT D5
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-15
Page 16
Read/Write Devices
5.3 SLG D11 ANT D5
Application area
The SLG D11 ANT D5 is a medium-performance read/write device with a serial interface and a separate antenna, designed specifically for storage, logi­stics, and distribution applications. It is designed for a range of up to 300 mm (depending on the label). The read/write device has an RS 232 serial interface (RS 422 interface on request), which permits communication with PCs or external PLCs.
For simple and rapid programming there is a C library available to the user that can be used under Windows 9x, 2000, and NT. The SLG D11 ANT D5 is multitag capable.
Ordering data
5-16
Figure 5-9 Read/write device SLG D11 ANT D5
Table 5-8 Ordering data for the SLG D11 ANT D5
Read/write device SLG D11 ANT D5
with an RS 232 serial interface for standard PCs, with a separate antenna
Accessories:
ANT D5 spacer kit
MOBY wide-range power pack
Cable and connector
MOBY D Configuration, Installation and Service Manual
Order No.
6GT2 601-0AC00
6GT2 690-0AB00
6GT2 494-0AA00
See Section 3.6
(4) J31069-D0147-U001-A3-7618
Page 17
Read/Write Devices
Technical data
Table 5-9 Technical data of the SLG D11 ANT D5
Inductive interface to MDS
Transmission frequency
Supported transponders
13.56 MHz
Transponder in accordance with ISO 15693 (e.g. I-Code, Tag-it, my-d)
Serial interface to user
Transmission protocol
Data transmission speed
RS 232 (RS 422 on request)
Asynchronous 8 bit
9600 bps to 38.4 kbps (adjustable)
Data backup
CRC 16
Output power 1 W
SLG - MDS read/write distances Typically 300 mm (see field data)
Software functions
MDS: Read, write, initialize, access rights, multitag
Programming
Windows 9x, 2000, and NT, with available 32-bit DLL
Multitag Ye s
Anti-collision speed Approx. 20 labels/s identifiable in
parallel
Power supply
Nominal value
Permissible range
24 VDC
20 to 30 VDC
Current consumption
Operation
Transient making current
150 mA
600 mA
Line length, SLG – PC
With RS 232
Antenna line length
30 m
3.60 m
Digital inputs/outputs None
Housing
Dimensions (in mm)
For antenna [L x W x H]
For electronic components
[L x W x H]
Color Antenna
SLG housing
Material Antenna
340 x 325 x 38
160 x 80 x 40 (without connector)
Black
Anthracite
Plastic ASA
Plastic (PA 12)
SLG housing
Connector
TNC connector
Antenna (can be connected to the SLG)
Mounting of SLG
Mounting of antenna
2 M5 screws
4 M5 screws
1
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-17
Page 18
Read/Write Devices
Table 5-9 Technical data of the SLG D11 ANT D5
Ambient temperature
in operation in transit and storage
Protection rating in accordance with EN 60529
SLG and antenna
–25 °C to +70 °C –25 °C to +70 °C
IP65
Shock in accordance with EN 60721-3-7 Class 7M2 Total shock reply spectrum type II
Vibration in accordance with EN 60721-3-7 Class 7M2
Weight, approx.
SLG
Antenna
Certifications Radio EN 300 330
1 To ensure optimal field data in a metallic environment, the ANT D5 is calibrated at
the factory at a distance of 100 mm from metal.
30 g
1 g (9 to 200 Hz)/
1.5 g (200 to 500 Hz)
600 g
1000 g
CE
Safe for pacemakers
Caution
The antenna cable is prepared in advance. If the cable is changed, the war­ranty and CE marking become invalid.
5-18
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 19
Read/Write Devices
Field data
Transmission window
Table 5-10 Field data of the SLG D11 ANT D5
Limit distance (S
) Max. 300 mm
g
(dependent on transponder)
Working distance (Sa) 0 to 240 mm
(dependent on transponder)
Length of the transmission window (Ld) 300 mm
Width of the transmission window (W) 120 mm Minimum distance from ANT D5 to ANT D5 2 m
L
d
1
S
a, min.
S
a, max.
S
Top view
g
1 At S
Transmission window
ANT D5
Spacing kit
the transmission window increases
a, min
S
a
Figure 5-10 Transmission window with the SLG D11 ANT D5
S
100
g
Side view
Metal plate
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-19
Page 20
Read/Write Devices
Metal-free space
Metal-free space with flush mounting
a = 150 mm
Metal
FCC information
a
a
h = 100 mm (non-metallic spacers)
a
Figure 5-11 Metal-free space for the SLG D11 ANT D5
Made in Germany
SIEMENS MOBY D SLG D11
FCC ID NXW-MOBYD-SLGD11
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO
FOLLOWING TWO CONDITIONS:
THE
THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
(1)
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
ACCEPT
UNDESIRED
OPERATION.
a
5-20
Caution
Any changes or modifications not expressly approved by the party responsi­ble for compliance could void the user’s authority to operate the equipment.
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 21
Definition of the distance D
Read/Write Devices
D
D
Distance D 2 m
Figure 5-12 Distance D: SLG D11 ANT D5
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-21
Page 22
Read/Write Devices
Dimensions (in mm)
160
40
5
26
A
12 33
View A
80
100
5.5
Ferrite
Minimal bending
5
Cable length 3.5 m
radius: 20 mm
Anti-kink protection bendable in all directions
4 x 5,5
340
300
325
731
Figure 5-13 Dimensioned drawing of the SLG D11 ANT D5
Note
In order to ensure optimal field data in surroundings where there is metal as well, the ANT D5 is calibrated at the factory at a distance of 100 mm from metal.
MOBY D ANT D5
see Chapter 5.2
spacer kit
5-22
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 23
5.4 SLG D12
Read/Write Devices
Application area
Ordering data
The SLG D12 is a medium-performance read/write device with a serial inter­face and an integrated antenna, designed for a range of up to 150 mm. The read/write device has an RS 232 serial interface (RS 422 interface on re­quest), which permits communication with PCs or external PLCs.
For simple and rapid programming there is a C library available to the user that can be used under Windows 9x, 2000, and NT. The SLG D12 is multitag capable.
Figure 5-14 Read/write device SLG D12
Table 5-11 Ordering data for the SLG D12
Read/write device SLG D12
With an RS 232 serial interface for standard PCs, with an integrated antenna
Accessories:
MOBY wide-range power pack
Cables and connectors
Order No.
6GT2 601-0AB00
6GT2 494-0AA00
See Section 3.6
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-23
Page 24
Read/Write Devices
Technical data
Table 5-12 Technical data of the SLG D12
Inductive interface to MDS
Transmission frequency
Supported transponders
Serial interface to user
Transmission protocol Data transmission speed
Data backup
SLG - MDS read/write distances Typically 150 mm (see field data)
Software functions
Programming
Multitag Ye s
Anti-collision speed Approx. 20 labels/s identifiable in pa-
Power supply
Nominal value
Permissible range
Current consumption
Operation
Transient making current
Line length, SLG – PC
With RS 232
Digital inputs/outputs None
Housing
Dimensions (L x B x H) in mm, without connector
Color
Material
Mounting 2 M5 screws
Ambient temperature
in operation in transit and storage
Protection rating in accordance with EN 60529
Shock in accordance with EN 60721-3-7 Class 7 M2 Total shock reply spectrum type II
Vibration in accordance with EN 60721-3-7 Class 7M2
13.56 MHz
Transponder in accordance with ISO 15693 (e.g. I-Code, Tag-it, my-d)
RS 232 (RS 422 on request)
Asynchronous 8 bit
9600 bps to 38.4 kbps (adjustable)
CRC 16
MDS: Read, write, initialize, access rights, multitag
Windows 9x, 2000, and NT, with avai­lable 32-bit DLL
rallel
24 VDC
20 to 30 VDC
150 mA
600 mA
30 m
160 x 80 x 40
Anthracite
Plastic (PA 12)
–25 °C to +70 °C –25 °C to +70 °C
IP65
30 g
1 g (9 to 200 Hz)/
1.5 g (200 to 500 Hz)
5-24
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 25
Table 5-12 Technical data of the SLG D12
Weight, approx. 500 g
Certifications Radio EN 300 330
CE
Safe for pacemakers
Read/Write Devices
Field data
Transmission window
Table 5-13 Field data SLG D12
Limit distance (S
) Max. 150 mm
g
(dependent on transponder)
Working distance (Sa) 0 to 120 mm
(dependent on transponder)
Length of the transmission window (Ld) 120 mm
Width of the transmission window (W) 48 mm Minimum distance from SLG D12 to SLG D12 500 mm
Transmission window Transponder
SLG D12
Standard Configuration: lengthwise x-axis (Lx)
Side view
Top view
1
1 At S
to the standard configuration
the transmission window can be enlarged in comparison
a, min
Figure 5-15 Transmission window of the SLG D12
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-25
Page 26
Read/Write Devices
Metal-free space
Metal
h
h = Physical height of the SLG = 40 mm
b
b
a
a
FCC information
Metal
a, b = Metal-free distances = 50 mm
Figure 5-16 Metal-free space of SLG D12
Made in Germany
SIEMENS MOBY D SLG D12
FCC ID NXW-MOBYD-SLGD12
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO
FOLLOWING TWO CONDITIONS:
THE
THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
(1)
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
ACCEPT
UNDESIRED
OPERATION.
Caution
Any changes or modifications not expressly approved by the party responsi­ble for compliance could void the user’s authority to operate the equipment.
5-26
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 27
Definition of distance D
Read/Write Devices
D
Distance D 0.5 m
D
Figure 5-17 Distance D: SLG D12
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-27
Page 28
Read/Write Devices
Dimensions (in mm)
80
5
X
70
Y
160
90
5.5
5
40
A
26
12 33
Figure 5-18 Dimensioned drawing of the SLG D12
View A
5-28
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 29
5.5 SLG D10S ANT D5
Read/Write Devices
Application area
The SLG D10S ANT D5 is a high-performance read/write device with a se­rial interface and a separate antenna, designed specifically for storage, logi­stics, and distribution applications. It is designed for a range of up to 600 mm (depending on the label). The read/write device has an RS 422 serial inter­face, which permits communication via interface modules (ASM 452, ASM 473 und ASM 475) to the SIMATIC S7 or PROFIBUS-DPV1.
FC 45 is available to the user for simple and rapid programming. Due to the high degree of protection (IP65) and the use of high-quality mate­rials, the SLG D10S ANT D5 ensures trouble-free use even under the most extreme industrial conditions.
Figure 5-19 Read/write device SLG D10S ANT D5
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-29
Page 30
Read/Write Devices
Ordering data
Table 5-14 Ordering data for the SLG D10S ANT D5
Read/write device SLG D10S ANT D5
With an RS 422 serial interface for connecting to an ASM 452, ASM 473, and ASM 475, with separate antenna
Accessories:
ANT D5 spacer kit
MOBY wide-range power pack
Cables and connectors
Order No.
6GT2 602-0AA00
6GT2 690-0AB00
6GT2 494-0AA00
See Section 3.6
Technical data
Table 5-15 Technical data of the SLG D10S ANT D5
Inductive interface to MDS
Transmission frequency
Supported transponders
13.56 MHz
S I-Code1
(e. g. MDS D139, MDS D160)
S Transponder in accordance with ISO
15693 (e. g. I-Code SLI, Tag-it HFI, my-d SRF 55V10P)
Serial interface to user
Transmission protocol
Data transmission speed
Data backup
Output power 4 W
SLG-MDS read/write distances Typically 450 mm (see field data)
Software functions Read, write, initialize MDS
Programming
Transmission protocol
Multitag in preparation
Power supply 24 VDC + 5%
RS 422
Asynchronous 8 bit
19.2 bps to 115.2 kbps (ASM-dependent)
CRC 16
The command Repeat is not permissible.
The user has a maximum buffer of 256 bytes in the SLG for pipelining. Hence, a command string can only con­tain as many individual commands as such that the sum of the header and user data fields lengths of the individual mes­sages does not exceed this value. The FC 45 limits the length of the user data fields to 233 bytes per individual mes­sage.
FC 45
3964 R
1
5-30
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 31
Table 5-15 Technical data of the SLG D10S ANT D5
Current consumption
Operation
Transient making current
Line length (SLG – SIMATIC S7)
With RS 422
Antenna line length
Digital inputs/outputs None
Housing
Dimensions (in mm)
For antenna [L x W x H]
For electronic components [L x W x H]
Color Antenna
SLG housing
Material Antenna
SLG housing
Connector
Antenna (can be connected to the SLG)
Mounting of SLG
Mounting of antenna
Ambient temperature
in operation in transit and storage
0.9 A
2.8 A/50 ms
300 m
3.60 m
340 x 325 x 38
320 x 145 x 100 (without connector)
Black
Anthracite
Plastic ASA
Aluminum
TNC connector
4 M6 screws
4 M5 screws
–20 °C to +55 °C –25 °C to +70 °C
Read/Write Devices
Protection rating in accordance with EN 60529
SLG and antenna
Shock in accordance with EN 60721-3-7 Class 7M2
Total shock response spectrum type II
Vibration in accordance with EN 60721-3-7 Class 7M2
Weight, approx.
SLG
Antenna
Certifications Radio EN 300 330
1 To ensure optimal field data in a metallic environment, the ANT D5 is calibrated at
the factory at a distance of 100 mm from metal.
IP65
30 g
1 g (9 to 200 Hz)/
1.5 g (200 to 500 Hz)
3500 g
1000 g
CE
Safe for pacemakers
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-31
Page 32
Read/Write Devices
Caution
The antenna cable is prepared in advance. If the cable is changed, the war­ranty and CE marking become invalid.
Note
After the ANT D5 antenna is removed from the SLG and connected again (screwed on), an init_run must be executed.
5-32
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 33
Read/Write Devices
Field data
Transmission window
Table 5-16 Field data of the SLG D10S ANT D5
Limit distance (S
) Max. 450 mm
g
(dependent on transponder)
Working distance (Sa) 0 to 380 mm
(dependent on transponder)
Length of the transmission window (Ld) 320 mm
Width of the transmission window (W) 128 mm Minimum distance from ANT D5 to ANT D5 2 m
L
d
1
S
a, min.
S
a, max.
S
Top view
g
1 At S
Transmission window
ANT D5
Spacing kit
the transmission window increases
a, min
S
S
a
100
Figure 5-20 Transmission window with the SLG D10S ANT D5
Side view
g
Metal plate
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-33
Page 34
Read/Write Devices
Metal-free space
Metal-free space with flush mounting
a = 150 mm
Metal
FCC information
a
a
h = 100 mm (non-metallic spacers)
a
Figure 5-21 Metal-free space for the SLG D10S ANT D5
Made in Germany
SIEMENS MOBY D SLG D10S
FCC ID NXW-MOBYD-SLGD10
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO
FOLLOWING TWO CONDITIONS:
THE
THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
(1)
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
ACCEPT
UNDESIRED
OPERATION.
a
5-34
Caution
Any changes or modifications not expressly approved by the party responsi­ble for compliance could void the user’s authority to operate the equipment.
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 35
Definition of the distance D
Read/Write Devices
D
D
Distance D 2 m
Figure 5-22 Distance D: SLG D10S ANT D5
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-35
Page 36
Read/Write Devices
Dimensions (in mm)
10
Cable length 3.5 m
Minimal bending
290
radius: 20 mm
4 x 5.5
320
Anti-kink protection bendable in all directions
A
1
7
125
145
View A
100
25
25
52,5
31
60
7
Note:
The SLG must be grounded using the grounding screw provided.
Figure 5-23 Dimensioned drawing of the SLG D10S ANT D5
Note
340
300
325
1
MOBY D ANT D5 spacer kit
5-36
In order to ensure optimal field data in surroundings where there is metal as well, the ANT D5 is calibrated at the factory at a distance of 100 mm from metal.
see Chapter 5.2
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 37
5.6 SLG D11S ANT D5
Read/Write Devices
Application area
The SLG D11 ANT D5 is a medium-performance read/write device with a serial interface and a separate antenna, designed specifically for storage, logi­stics, and distribution applications. It is designed for a range of up to 300 mm (depending on the label). The read/write device has an RS 422, serial interface, which permits commu­nication via interface modules (ASM 452, ASM 473 und ASM 475) to the SIMATIC S7 or PROFIBUS-DPV1.
FC 45 is available to the user for simple and rapid programming. A robust housing and the high degree of protection (IP65) permit deployment in the most severe industrial environments.
Figure 5-24 Read/write device SLG D11S ANT D5
Ordering information
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
Table 5-17 SLG D11S ANT D5 ordering information
Read/write device SLG D11S ANT D5
With an RS 422 serial interface for connecting to an ASM 452, ASM 473 and ASM 475, with separate antenna
Accessories:
Spacer kit for ANT D5
MOBY DC 24 V wide-range power pack
Cables and connectors
Order No.
6GT2 602-0AC00
6GT2 690-0AB00
6GT2 494-0AA00
See Section 3.6
5-37
Page 38
Read/Write Devices
Technical data
Table 5-18 SLG D11S ANT D5 technical data
Inductive interface to MDS
Transmission frequency
Supported transponders
13.56 MHz
S I-Code1
(e. g. MDS D139, MDS D160)
S Transponder in accordance with
ISO 15693 (e. g. I-Code SLI, Tag-it HFI, my-d SRF 55V10P)
Serial interface to user
Transmission protocol
Data transmission speed
Data backup
Output power 1 W
SLG – MDS read/write distances Typically 300 mm (see field data)
Software functions MDS read, write, initialize
Programming
Transmission protocol
Multitag No
Power supply
Operation
Permissible range
Current consumption
Operation
Transient making current
Line length (SLG – SIMATIC S 7)
With RS 422
Antenna line length
Digital inputs/outputs None
RS 422
Asynchronous 8 bit
19.2 kBaud
CRC 16
Command strings are not permitted. The Repeat command has not been implemented. The greatest possible length of the user data field in a command is 233 bytes.
FC 45
3964 R
24 VDC
20 V to 30 VDC
150 mA
600 mA
300 m
3.60 m
1
5-38
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 39
Table 5-18 SLG D11S ANT D5 technical data
Housing
Dimensions (in mm)
For antenna [L x W x H]
for the electronics [L x B x H]
Color Antenna
SLG housing
Material Antenna
SLG housing
Connector
Antenna (can be connected to the SLG)
Mounting of SLG
Mounting of antenna
Ambient temperature
in operation in transport and storage
Protection rating in accordance with EN 60529
SLG and antenna
Read/Write Devices
340 x 325 x 38
160 x 80 x 40 (without connector)
Black
Anthracite
Plastic ASA
Plastic (PA 12)
TNC connector
2 M5 screws
4 M5 screws
–25 °C to +70 °C –25 °C to +70 °C
IP65
Field data
Shock in accordance with
30 g EN 60721-3-7 Class 7M2 Total shock reply spectrum type II
Vibration in accordance with EN 60721-3-7 Class 7M2
1 g (9 to 200 Hz)/
1.5 g (200 to 500 Hz)
Weight, approx.
SLG
Antenna
Approx. 600 g
Approx. 1000 g
Certifications Radio EN 300 330
CE
Safe for pacemakers
1 To ensure optimal field data in a metallic environment, the ANT D5 is calibrated at
the factory at a distance of 100 mm from metal.
Table 5-19 SLG D11S ANT D5 field data
Limit distance (S
) Max. 300 mm
g
(dependent on transponder)
Working distance (Sa) 0 to 240 mm
(dependent on transponder)
Length of the transmission window (Ld) 300 mm
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-39
Page 40
Read/Write Devices
Table 5-19 SLG D11S ANT D5 field data
Width of the transmission window (W) 120 mm Minimum distance from ANT D5 to ANT D5 2 m
Transmission window
S
a, min.
S
a, max.
1 At S
Transmission window
ANT D5
Spacing kit
L
d
Top view
1
the transmission window increases
a, min
S
g
Side view
S
g
S
a
100
Metal plate
5-40
Figure 5-25 SLG D11S ANT D5 transmission window
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 41
Metal-free space
Read/Write Devices
Metal-free space with flush mounting
a = 150 mm
Metal
FCC information
a
a
h = 100 mm (non-metallic spacers)
a
Figure 5-26 SLG D11S ANT D5 metal-free space
Made in Germany
SIEMENS MOBY D SLG D11S
FCC ID NXW-MOBYD-SLGD11
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO
FOLLOWING TWO CONDITIONS:
THE
THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
(1)
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
ACCEPT
UNDESIRED
OPERATION.
a
Caution
Any changes or modifications not expressly approved by the party responsi­ble for compliance could void the user’s authority to operate the equipment.
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-41
Page 42
Read/Write Devices
Definition of the distance D
D
D
Distance D 2 m
Figure 5-27 Distance D: SLG D11S ANT D5
5-42
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 43
Dimensions (in mm)
Read/Write Devices
160
40
5
26
A
12 33
View A
80
100
5.5
Ferrite
Minimal bending
5
Cable length 3.5 m
radius: 20 mm
Anti-kink protection bendable in all directions
4 x 5.5
340
300
325
731
Figure 5-28 SLG D11S ANT D5 dimensioned drawing
Note
In order to ensure optimal field data in surroundings where there is metal as well, the ANT D5 is calibrated at the factory at a distance of 100 mm from metal.
MOBY D ANT D5
See Chapter 5.2
spacer kit
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-43
Page 44
Read/Write Devices
5.7 SLG D12S
Application area
Ordering information
The SLG D12 is a medium-performance read/write device with a serial inter­face and an integrated antenna, designed for a range of up to 150 mm (depen­ding upon the label). The read/write device has an RS 422 serial interface, which permits communication via interface modules (ASM 452, ASM 473 und ASM 475) to the SIMATIC S7 or PROFIBUS-DP-V1.
FC 45 is available to the user for simple and rapid programming. A robust housing and the high degree of protection (IP65) permit deployment in the most severe industrial environments.
Figure 5-29 SLG D12S read/write device
Table 5-20 SLG D12S ordering information
SLG D12S read/write device
With an RS 422 serial interface for connecting to an ASM 452, ASM 473 und ASM 475, with integrated antenna
Accessories:
MOBY DC 24 V wide-range power pack
Cables and Connectors
Order No.
6GT2 602-0AB00
6GT2 494-0AA00
See Section 3.6
5-44
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 45
Read/Write Devices
Technical data
Table 5-21 SLG D12S technical data
Inductive interface to MDS
Transmission frequency
Supported transponders
13.56 MHz
S I-Code1
(e. g. MDS D139, MDS D160)
S Transponder in accordance with
ISO 15693 (e. g. I-Code SLI, Tag-it HFI, my-d SRF 55V10P)
Serial interface to user
Transmission protocol
Data transmission speed
Data backup
Output power 1 W
SLG – MDS read/write distances Typically 150 mm (see field data)
Software functions MDS read, write, initialize
Programming
Transmission protocol
Multitag No
Power supply
Operation
Permissible range
Current consumption
Operation
Transient making current
Line length (SLG – SIMATIC S 7)
With RS 422
Digital inputs/outputs None
Housing
Dimensions (L x B x H) in mm, without connectors
Color
Material
Mounting 2 M5 screws
Ambient temperature
in operation in transit and storage
RS 422
Asynchronous 8 bit
19.2 kBaud
CRC 16
Command strings are not permitted. The Repeat command has not been im­plemented. The greatest possible length of the user data field in a command is 233 bytes.
FC 45
3964 R
24 VDC
20 V to 30 VDC
150 mA
600 mA
300 m
160 x 80 x 40
Anthracite
Plastic (PA 12)
–25 °C to +70 °C –25 °C to +70 °C
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-45
Page 46
Read/Write Devices
Table 5-21 SLG D12S technical data
Field data
Protection rating in accordance with
IP65
EN 60529
Shock in accordance with EN 60721-3-7
30 g Class 7 M2 Total shock response spectrum Type II
Vibration in accordance with EN 60721-3-7 Class 7M2
1 g (9 to 200 Hz)/
1.5 g (200 to 500 Hz)
Weight, approx. 600 g
Certifications Radio EN 300 330
CE
Safe for pacemakers
Table 5-22 SLG D12S field data
Limit distance (S
) Max. 150 mm
g
(dependent on transponder)
Working distance (Sa) 0 to 120 mm
(dependent on transponder)
Length of the transmission window (Ld) 120 mm
Width of the transmission window (W) 48 mm Minimal distance from SLG D12S to SLG D12S 500 mm
5-46
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 47
Read/Write Devices
Transmission window
Transmission window Transponder
SLG D12S
Standard Configuration: lengthwise x-axis (Lx)
1 At S
to the standard configuration
the transmission window can be enlarged in comparison
a, min
Figure 5-30 Transmission window of the SLG D12S
Side view
Top view
1
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-47
Page 48
Read/Write Devices
Metal-free space
Metal
h
h = Physical height of the SLG = 40 mm
b
b
a
a
FCC information
Metal
a, b = Metal-free distances = 50 mm
Figure 5-31 SLG D12S metal-free space
Made in Germany
SIEMENS MOBY D SLG D12S
FCC ID NXW-MOBYD-SLGD12
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO
FOLLOWING TWO CONDITIONS:
THE
THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
(1)
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
ACCEPT
UNDESIRED
OPERATION.
Caution
Any changes or modifications not expressly approved by the party responsi­ble for compliance could void the user’s authority to operate the equipment.
5-48
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618
Page 49
Definition of the Distance D
Read/Write Devices
D
Distance D 0.5 m
D
Figure 5-32 Distance D: SLG D12S
MOBY D Configuration, Installation and Service Manual (4) J31069-D0147-U001-A3-7618
5-49
Page 50
Read/Write Devices
Dimensions (in mm)
5
80 40
X
70
Y
160
90
5.5
A
26
12 33
Figure 5-33 Dimensioned drawing SLG D12S
5
View A
5-50
MOBY D Configuration, Installation and Service Manual
(4) J31069-D0147-U001-A3-7618