Sick SRS50-HFA0-K21 Data Sheet

0 (0)
Sick SRS50-HFA0-K21 Data Sheet
<![if ! IE]>

<![endif]>P r o d u c t d a t a s h e e t

SRS50-HFA0-K21

SRS/SRM50

MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE®

SRS50-HFA0-K21 | SRS/SRM50

MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE®

A B C D E F

H

I

J

K

L

M N O P Q R S T

Ordering information

Type

 

Part no.

 

 

 

SRS50-HFA0-K21

 

1037067

 

 

 

Other models and accessories www.sick.com/SRS_SRM50

Illustration may differ

Detailed technical data

Performance

Sine/cosine periods per revolution

 

1,024

 

 

 

Number of the absolute ascertainable revo-

 

1

lutions

 

 

 

 

 

Total number of steps

 

32,768

 

 

 

Measuring step

 

0.3 ″ For interpolation of the sine/cosine signals with, e. g., 12 bits

 

 

 

Integral non-linearity

 

Typ. ± 45 ″, Error limits for evaluating sine/cosine period, without mechanical tension of the

 

 

stator coupling

 

 

 

Differential non-linearity

 

± 7 ″, Non-linearity within a sine/cosine period

 

 

 

Operating speed

 

≤ 6,000 min ¹, up to which the absolute position can be reliably produced

 

 

 

Available memory area

 

128 Byte

 

 

 

Interfaces

Type of code for the absolute value Code sequence

Communication interface

Electrical data

Connection type

Supply voltage

Recommended supply voltage

Power consumption

Output frequency for sine/cosine signals

1) Without load.

Mechanical data

Shaft version

Flange type / stator coupling

Binary

Increasing, when turning the shaft For clockwise rotation, looking in direction “A” (see dimensional drawing), For clockwise shaft rotation, looking in direction “A” (see dimensional drawing)

HIPERFACE®

Male connector, 8-pin, radial

7 V DC ... 12 V DC

8 V DC

80 mA 1)

≤ 200 kHz

Tapered shaft

Spring mounting plate, Spring mounting plate

2

MOTOR FEEDBACK SYSTEMS | SICK

Product data sheet | 2020-08-21 17:31:21

 

 