Sick DFS60B-TEPK10000 Data Sheet

5 (1)
Sick DFS60B-TEPK10000 Data Sheet
<![if ! IE]>

<![endif]>P r o d u c t d a t a s h e e t

DFS60B-TEPK10000

DFS60

INCREMENTAL ENCODERS

DFS60B-TEPK10000 | DFS60

INCREMENTAL ENCODERS

A B C D E F

H

I

J

K

L

M N O P Q R S T

Ordering information

Type

 

Part no.

 

 

 

DFS60B-TEPK10000

 

1036924

 

 

 

Other models and accessories www.sick.com/DFS60

 

 

Illustration may differ

Detailed technical data

Performance

Pulses per revolution

Measuring step

Measuring step deviation at non binary number of lines

Error limits

1) See maximum revolution range.

10,000 1)

90° electronically/ppr

±0.01°

±0.05°

Interfaces

Communication interface Communication Interface detail

Factory setting

Number of signal channels

Programmable/configurable Initialization time

Output frequency

Load current

Power consumption

1) With mechanical zero pulse width.

Incremental

TTL / HTL

Factory setting: output level TTL

6-channel

32 ms 1)

30 ms

600 kHz

30 mA

0.7 W (without load)

Electrical data

Connection type

 

Cable, 8-wire, universal, 1.5 m 1)

Supply voltage

 

4.5 ... 32 V

 

 

 

Reference signal, number

 

1

 

 

 

1) The universal cable connection is positioned so that it is possible to lay it without bends in a radial or axial direction.

2)Programming TTL with ≥ 5.5 V: short-circuit opposite to another channel or GND permissable for maximum 30 s.

3)This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no.

8015532.

2

ENCODERS | SICK

Product data sheet | 2020-08-08 10:34:51

 

 

Subject to change without notice

DFS60B-TEPK10000 | DFS60

INCREMENTAL ENCODERS

Reference signal, position

 

90°, electric, logically gated with A and B

 

 

 

Reverse polarity protection

 

 

 

 

 

Short-circuit protection of the outputs

 

2)

MTTFd: mean time to dangerous failure

 

300 years (EN ISO 13849-1) 3)

1)The universal cable connection is positioned so that it is possible to lay it without bends in a radial or axial direction.

2)Programming TTL with ≥ 5.5 V: short-circuit opposite to another channel or GND permissable for maximum 30 s.

3)This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.

Mechanical data

Mechanical design

 

Through hollow shaft

 

 

 

Shaft diameter

 

12 mm

 

 

 

Weight

 

+ 0.2 kg

 

 

 

Shaft material

 

Stainless steel

 

 

 

Flange material

 

Aluminum

 

 

 

Housing material

 

Aluminum die cast

 

 

 

Start up torque

 

0.8 Ncm (+20 °C)

 

 

 

Operating torque

 

0.6 Ncm (+20 °C)

 

 

 

Permissible shaft movement, axial stat-

 

± 0.5 mm / ± 0.2 mm

ic/dynamic

 

 

 

 

 

Permissible shaft movement, radial stat-

 

± 0.3 mm / ± 0.1 mm

ic/dynamic

 

 

 

 

 

Operating speed

 

≤ 6,000 min ¹ 1)

Moment of inertia of the rotor

 

40 gcm²

 

 

 

Bearing lifetime

 

3.6 x 10^10 revolutions

 

 

 

Angular acceleration

 

≤ 500,000 rad/s²

 

 

 

1) Allow for self-heating of 3.3 K per 1,000 rpm when designing the operating temperature range.

Ambient data

EMC

Enclosure rating

Permissible relative humidity Operating temperature range

Storage temperature range Resistance to shocks Resistance to vibration

1)Stationary position of the cable.

2)Flexible position of the cable.

According to EN 61000-6-2 and EN 61000-6-3

IP65, housing side, cable connection (according to IEC 60529) IP65, shaft side (according to IEC 60529)

90 % (condensation of the optical scanning not permitted)

–40 °C ... +100 °C 1) –30 °C ... +100 °C 2)

–40 °C ... +100 °C, without package

70 g, 6 ms (according to EN 60068-2-27)

30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)

Classifications

ECl@ss 5.0

 

27270501

 

 

 

 

 

ECl@ss 5.1.4

 

27270501

 

 

 

 

 

ECl@ss 6.0

 

27270590

 

 

 

 

 

2020-08-08 10:34:51 | Product data sheet

 

ENCODERS | SICK

3

Subject

to change without notice

 

 

 

Loading...