SHARP R21JCA Service Manual

R-21JCA
SUPPLEMENTAL SERVICE MANUAL
S8213R21HCPA/
LIGHT DUTY
COMMERCIAL
MICROWAVE OVEN
1000W/ R-21JCA
TIME GUIDE FOR ONE SERVING
1
5
- 3
0
se
c.
3
0
- 6
0
s
ec
.
B
a
ge
l, R
o
ll
H
o
t D
o
g
M
u
ffin, P
a
s
try
P
iz
z
a S
lice
P
ie
S
lic
e
S
m
a
ll S
a
n
d
w
ic
h
1
- 2
m
in
.
2
- 3
m
in.
B
e
ve
rag
e, S
ou
p
C
a
ss
ero
le
, S
te
w
La
rg
e
S
a
nd
w
ich
C
h
ili, C
h
o
w
de
r
P
op
co
rn
, 1
.5
o
z
.
P
op
c
orn
, 3
.5 o
z.
50
1
40
F
E
1.5
30
G
D
H
C
20
I
B
2
10
J
A
K
0
L
2.5
M
C
O
M
M
E
R
C
I
A
L
M
I
C
R
O
W
A
V
E
O
V
E
N
T
S
Q
R
6
5
INSTRUCTIONS
With the door closed,turn the tim the desired tim
e. Oven will begin
operating im
m
ediately. To shut oven off manually,return tim to "0".
N
O
3
P
4
er to
er
MODEL
R-21JCA
In the interest of user-safety the oven should be restored to its original condition and only parts identical to those specified should be used.
WARNING TO SERVICE PERSONNEL: Microwave ovens con­tain circuitry capable of producing very high voltage and current. Contact with the following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capaci­tor, High Voltage Power Transformer, Magnetron, High Volt­age Rectifier Assembly, High Voltage Harness etc..)
This is a supplemental Service Manual for Model R-21JCA. This model is quite similar to base model R-21HC. Use this supplemental manual together with the Base Model Service Manual (Reference No. is S7813R21HCP//) for complete operation, service information, etc..

TABLE OF CONTENTS

Page PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO
AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY...................INSIDE FRONT COVER
BEFORE SERVICING ......................................................................................................INSIDE FRONT COVER
WARNING TO SERVICE PERSONNEL................................................................................................................1
PRODUCT SPECIFICATIONS ..............................................................................................................................4
OPERATION..........................................................................................................................................................4
SCHEMATIC DIAGRAM ........................................................................................................................................ 5
TEST PROCEDURE..............................................................................................................................................5
CONTROL PANEL ASSEMBLY ............................................................................................................................8
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE................................................................11
CONTROL PANEL CIRCUIT ............................................................................................................................... 14
PRINTED WIRING BOARD ................................................................................................................................. 15
PARTS LIST ........................................................................................................................................................16
PACKING AND ACCESSORIES .........................................................................................................................20
SHARP CORPORATION
This document has been published to be used for after sales service only. The contents are subject to change without notice.
23
R-21JCA
PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
(a) Do not operate or allow the oven to be operated with the door open. (b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and latches, (5) evidence of dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity, and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave
generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.
(e) A microwave leakage check to verify compliance with the Federal Performance Standard should be
performed on each oven prior to release to the owner.

BEFORE SERVICING

Before servicing an operative unit, perform a microwave emission check as per the Microwave Measurement Procedure outlined in this service manual. If microwave emissions level is in excess of the specified limit, contact SHARP ELECTRONICS CORPORATION immediately @1-800-237-4277.
If the unit operates with the door open, service person should 1) tell the user not to operate the oven and 2) contact SHARP ELECTRONICS CORPORATION and The Food and Drug Administration's Center for Devices and Radiological Health immediately.
Service personnel should inform SHARP ELECTRONICS CORPORATION of any certified unit found with emissions in excess of 4mW/cm2. The owner of the unit should be instructed not to use the unit until the oven has been brought into compliance.
24

WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of pro­ducing very high voltage and current, contact with following parts fatal, electrical shock.
(Example) High Voltage Capacitor, High Voltage Power Trans-
former, Magnetron, High Voltage Rectifier Assem­bly, High Voltage Harness etc..
Read the Service Manual carefully and follow all instructions.
may result in a severe, possibly
R-21JCA
Don't Touch ! Danger High Voltage
Before Servicing
1. Disconnect the power supply cord , and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
WARNING:RISK OF ELECTRIC SHOCK.
DISCHARGE THE HIGH-VOLTAGE CAPACITOR BEFORE SERVICING.
The high-voltage capacitor remains charged about 60 seconds after the oven has been switched off. Wait for 60 seconds and then short-circuit the connection of the high­voltage capacitor (that is the connecting lead of the high­voltage rectifier) against the chassis with the use of an insulated screwdriver.
Whenever troubleshooting is performed the power supply must be disconnected. It may in, some cases, be necessary to connect the power supply after the outer case has been removed, in this event,
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that the leads remain isolated from other components and oven chassis by using insulation tape.
6. After that procedure, reconnect the power supply cord.
When the testing is completed,
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Reconnect the leads to the primary of the power transformer.
5. Reinstall the outer case (cabinet).
6. Reconnect the power supply cord after the outer case is installed.
7. Run the oven and check all functions.
After repairing
1. Reconnect all leads removed from components during testing.
2. Reinstall the outer case (cabinet).
3. Reconnect the power supply cord after the outer case is installed.
4. Run the oven and check all functions.
Microwave ovens should not be run empty. To test for the presence of microwave energy within a cavity, place a cup of cold water on the oven turntable, close the door and set the power to HIGH and set the microwave timer for two (2) minutes. When the two minutes has elapsed (timer at zero) carefully check that the water is now hot. If the water remains cold carry out Before Servicing procedure and re­examine the connections to the component being tested.
When all service work is completed and the oven is fully assembled, the microwave power output should be checked and a microwave leakage test should be carried out.
1
R-21JCA

MICROWAVE MEASUREMENT PROCEDURE

A. Requirements:
1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external surface of the oven.
2) Safety interlock switches: Primary interlock relay and door sensing switch shall prevent microwave radiation emission in excess of the requirement as above mentioned, secondary interlock switch shall prevent microwave radiation emission in excess of 5 mW/cm2 at any point 5cm or more from the external surface of the oven.
B. Preparation for testing: Before beginning the actual measurement of leakage, proceed as follows:
1) Make sure that the actual instrument is operating normally as specified in its instruction booklet.
Important: Survey instruments that comply with the requirement for instrumentation as prescribed by the performance standard for microwave ovens, 21 CFR 1030.10(c)(3)(i), must be used for testing.
2) Place the oven tray in the oven cavity.
3) Place the load of 275±15 ml (9.8 oz) of tap water initially at 20±5˚C (68˚F) in the center of the oven cavity. The water container shall be a low form of 600 ml (20 oz) beaker with an inside diameter of approx. 8.5 cm (3-1/2 in.) and made of an electrically nonconductive material such as glass or plastic. The placing of this standard load in the oven is important not only to protect the oven, but also to insure that any leakage is measured accurately.
4) Set the cooking control on Full Power Cooking Mode.
5) Close the door and select a cook cycle of several minutes. If the water begins to boil before the survey is completed, replace it with 275 ml of cool water.
C. Leakage test:
Closed-door leakage test (microwave measurement)
1) Grasp the probe of the survey instrument and hold it perpendicular to the gap between the door and the body of the oven.
2) Move the probe slowly, not faster than 1 in./sec. (2.5 cm/sec.) along the gap, watching for the maximum indication on the meter.
3) Check for leakage at the door screen, sheet metal seams and other accessible positions where the continuity of the metal has been breached (eg., around the switches, indicator, and vents). While testing for leakage around the door pull the door away from the front of the oven as far as is permitted by the closed latch assembly.
4) Measure carefully at the point of highest leakage and make sure that the highest leakage is no greater than 4mW/cm2, and that the secondary interlock switch does turn the oven OFF before any door movement.
NOTE: After servicing, record data on service invoice and microwave leakage report.
2
R-21JCA
SERVICE MANU AL
LIGHT DUTY
COMMERCIAL
MICROWAVE OVEN
R-21JCA
FOREWORD
This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information for the SHARP MICROWAVE OVEN, R-21JCA.
The model R-21JCA is quite similar to base model R-21HC (Refer No. is S7813R21HCP//). It is recommended that service personnel carefully study the entire text of this manual and the base model's manual so
that they will be qualified to render satisfactory customer service. Check the interlock switches and the door seal carefully. Special attention should be given to avoid electrical shock and
microwave radiation hazard.
WARNING
Never operate the oven until the following points are ensured. (A) The door is tightly closed. (B) The door brackets and hinges are not defective. (C) The door packing is not damaged. (D) The door is not deformed or warped. (E) There is no other visible damage with the oven.
Servicing and repair work must be carried out only by trained service personnel.
DANGER
Certain initial parts are intentionally not grounded and present a risk of electrical shock only during servicing. Service personnel - Do not contact the following parts while the appliance is energized; High Voltage Capacitor, Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness; If provided, Vent Hood, Fan assembly, Cooling Fan Motor.
All the parts marked “*” on parts list are used at voltages more than 250V. Removal of the outer wrap gives access to voltage above 250V. All the parts marked “” on parts list may cause undue microwave exposure, by themselves, or when they are
damaged, loosened or removed.
SHARP ELECTRONICS CORPORATION
SHARP PLAZA, MAHWAH,
NEW JERSEY 07430-2135
3
R-21JCA

SPECIFICATION

ITEM DESCRIPTION
Power Requirements 120 Volts
14 Amperes 60 Hertz / Single phase, 3 wire grounded
Power Output 1000 watts (IEC 705 Test Procedure)
Operating frequency of 2450MHz
Case Dimensions Width 20-1/2" (520mm)
Height 12-1/8" (309mm) Depth 16" (406mm)
Cooking Cavity Dimensions Width 13-7/8" (353mm) (1.0 Cubic Feet ) Height 8-1/8" (207mm)
Depth 14-5/8" (370mm)
Control Complement Light Up Dial (6 minutes)
No cooking control Oven Cavity Light Yes Safety Standard UL Listed FCC Authorized
DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J, NSF Certified

OPERATION

DESCRIPTION OF OPERATING SEQUENCE
The following is a description of component functions during oven operation.
OFF CONDITION
Closing the door activates door sensing switch and second­ary interlock switch. (In this condition, the monitor switch contacts are opened.) When oven is plugged in, 120 volts A.C. is supplied to the control unit (Figure O-1).
COOKING CONDITION
When the Light Up Dial is turned, the following operations occur:
1. The contacts of relays are closed and components connected to the relays are turned on as follows. (For details, refer to Figure O-2)
RELAY CONNECTED COMPONENTS RY-1 Oven lamp/ Antenna motor/ Fan motor RY-2 Power transformer
2. 120 volts A.C. is supplied to the primary winding of the power transformer and is converted to about 3.2 volts A.C. output on the filament winding, and approximately 2150 volts A.C. on the high voltage winding.
3. The filament winding voltage heats the magnetron filament and the H.V. winding voltage is sent to a voltage doubler circuit.
4. The microwave energy produced by the magnetron is channelled through the waveguide into the cavity feed­box, and then into the cavity where the food is placed to be cooked.
5. Upon completion of the cooking time, the power transformer, oven lamp, etc. are turned off, and the generation of microwave energy is stopped. The oven will revert to the OFF condition.
6. When the door is opened during a cook cycle, monitor switch, door sensing switch, secondary interlock switch, relay (RY2) and primary interlock relay(RY1) are activated with the following results. The circuits to the antenna motor, the cooling fan motor, the oven lamp and the high voltage components are de-energized, and the cooking program will be canceled when the door was opened.
7. The monitor switch electrically monitors the operation of the secondary interlock switch and primary interlock relay(RY1) and is mechanically associated with the door so that it will function in the following sequence.
(1)
When the door opens from the closed position, the primary interlock relay(RY1) and secondary interlock switch open their contacts. Then the monitor switch contacts close.
(2)When the door is closed from the open position, the
monitor switch contacts open first. Then the contacts of the secondary interlock switch and door sensing switch close.
If the secondary interlock switch and primary interlock relay (RY1) fail with the contacts closed when the door is opened, the closing of the monitor switch contacts will form a short circuit through the monitor fuse, secondary interlock switch, and primary interlock relay(RY1), causing the monitor fuse to blow.
4
SCHEMATIC
NOTE: CONDITION OF OVEN
1. LIGHT UP DIAL OFF.
2. DOOR CLOSED.
NOTE:
R-21JCA
Indicates components with potential above 250 V.
AC120V 60 Hz
MONITOR FUSE 20A
THERMAL CUT-OUT 125˚C (OVEN)
A5
A3 A1
THERMAL CUT-OUT 145˚C (MAG.)
CONTROL UNIT
DOOR SENSING SWITCH
SECONDARY INTERLOCK SWITCH
Figure O-1 Oven Schematic-OFF Condition
RY1
PRIMARY
RY2
INTERLOCK
RELAY
COOK
RELAY
OL FM AM
OVEN LAMP
FAN MOTOR
ANTENNA MOTOR
POWER TRANSFORMER
MONITOR SWITCH
CAPACITOR
0.94 µF 2400V
MAGNETRON
RECTIFIER
PROCEDURE
LETTER

I CONTROL PANEL ASSEMBLY TEST

WARNING : To prevent an electric shock do not touch the electrical parts and the printed wiring
board. Because the control unit is "TRANSLESS CIRCUIT" and many electrical parts are used at A.C. line voltage.
The control panel consists of circuits including semiconductors such as LSI, ICs, etc. Therefore, unlike conventional microwave ovens, proper maintenance cannot be performed with only a voltmeter and ohmmeter. In this service manual troubleshooting by unit replacement is described according to the symptoms indicated.
Before testing,
1) Disconnect the power supply cord and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Disconnect the leads to the primary of the power transformer.
5) Ensure that these leads remain isolated from other components and oven chassis by using insulation tape.
6) After that procedure, re-connect the power supply cord.
1. Control Panel The following symptoms indicate a defective control unit.
1-1 In connection with LEDs
a) At a certain LED, all or some LEDs do not light up. b) At a certain LED, brightness is low. c) Only one LED does not light up. d) All or some LEDs continue to light up. e) A certain group of LEDs do not light up.
f) The LEDs flicker.

TEST PROCEDURES

COMPONENT TEST
5
R-21JCA
TEST PROCEDURES
PROCEDURE
LETTER

J RELAY TEST

COMPONENT TEST
1-2 Other possible troubles caused by defective control unit.
a) Buzzer does not sound or continues to sound. b) Clock is not possible. c) Cooking time can not be set.
When testing is completed,
1) Disconnect the power supply cord and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Reconnect all leads removed from components during testing.
5) Re-install the outer case (cabinet).
6) Reconnect the power supply cord after the outer case is installed.
7) Run the oven and check all functions.
1. Disconnect the power supply cord and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Ensure that these leads remain isolated from other components and oven chassis by using insulation tape.
6. After that procedure, re-connect the power supply cord.
7. Remove the outer case and check voltage between Pin No. 5 of the 3 pin connector (A) and the common terminal of the relay RY1 on the control unit with an A.C. voltmeter. The meter should indicate 120 volts, if not check oven circuit.
RY1 AND RY2 Relay Test
These relays are operated by D.C. voltage Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operation.
DC. voltage indicated................. Defective relay.
DC. voltage not indicated........... Check diode which is connected to the relay coil. If diode is
good, control unit is defective.
RELAY SYMBOL OPERATIONAL VOLTAGE CONNECTED COMPONENTS
RY1 RY2
Approx. 19.2V D.C. Oven lamp / Antenna motor / Cooling fan motor Approx. 19.9V D.C. Power transformer
The voltage under the condition when all LEDs light up.
8. Disconnect the power supply cord and then remove outer case.
9. Open the door and block it open.
10.Discharge high voltage capacitor.
11.Reconnect all leads removed from components during testing.
12.Re-install the outer case (cabinet).
13.Reconnect the power supply cord after the outer case is installed.
14.Run the oven and check all functions.

K FOIL PATTERN ON THE PRINTED WIRING BOARD TEST

To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on the PWB, this foil pattern acts as a fuse.
1. Foil pattern check and repairs.
1) Disconnect the power supply cord and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Follow the troubleshooting guide given below for repair.
6