FEATURES
SHARP’s Original Air Disinfecting Technology.
Plasmacluster helps to improve the air quality by eliminating of airborne mould*1, viruses*2, allergens*3, and adhering odour*4.
Release Plasmacluster Ions.
1
Pl asmac luste r Ions a re the same positive and negative ion s f o und in na tu r e . T h e ions are surrounded by water molecules, and are released into the air.
Attack Airborne microbes.
2
Th e ions form h ydroxi de radi c a ls th a t ar e high l y oxidizing only when they adh e re to th e s ur f a ce s o f mo u l d an d vir u s e s . Th e y instantly remove the hydrogen from t h e s u r f a ce p r o t eins, breaking them down.
Hydroxide (OH) radical
Hydrogen(H)
Protein
Return to the air as water.
3
The hydroxide (OH) radicals combine with hydrogen (H) to form water (H2O) which returns to the air.
Testing and vencation Organization.
*1 Ishikawa Health Service Association. *2 Retroscreen Virology, Ltd, UK. *3 Hiroshima University. *4 Japan Spinners Inspecting Foundation.
water (H2O)
GLP*5-compliant test facilities have gathered highly reliable safety data on Sharp's Plasmacluster technology.
•Skin irritation/corrosion test
•Eye irritation/corrosion test
Inhalation toxicity test (lung tissue genetic impact assessment)
Tested by: Mitsubishi Chemical Safety Institute *5 GLP(G ood Laborat ory Practic e) is a sys tem of ma na gem en t con tr ols f or test fac il iti es and tes t pr oc ed ure s des ig ned to ens ur e the reliabi li ty of
chemical safety assessment tests.
ENGLISH
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
• WARNING
• CAUTIONS CONCERNING OPERATION
• INSTALLATION GUIDELI
PARTS NAME
• FRONT
• BACK
INSTALLATION POSITION
OPERATION
CLEANING AND MAINTENANCE
• MAIN UNIT
• FILTER
...............................................................
......................................
NES
........................................................
.................................................................................
...................................................................................
...........................................
......................................................................
.............................
...........................................................................
.................................................................................
...............
......................
PLASMACLUSTER ION GENERATING UNIT REPLACEMENT
HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT SPECIFICATIONS TROUBLESHOOTING
............................................................
....................................................
....
....
E-2
E-2 E-2 E-2
E-3
E-3 E-3
E-4
E-4
E-5
E-5
E-5
E-6
E-7
E-8
E-8
ENGLISH
• While IG-A10J can inactivate and eliminate suspended viruses and other contaminants, it cannot create a completely sterile envi­ronment. SHARP does not guarantee its ability to prevent micro­bial infection.
• To enable stable emission of high-density Plasmacluster ions, the Plasmacluster Ion Generating Unit mounted in IG-A10J will need to be replaced periodically*
*Replacement is required approximately every 2 years (17,500 hours) when operated
24 hours a day. IG-A10J will stop operating after about 26 months (19,000 hours) if the Plasmacluster ion generating unit is not replaced.
Thank you for purchasing this SHARP Plasmacluster Ion Generator. Please read this manual carefully before using the Plasmacluster Ion Generator. After reading, keep the manual in a convenient location for future reference.
.
E-1
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
WARNING - To reduce the risk of electrical shock, re, or injury :
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
DO NOT use the unit if the power cord or plug is damaged, or the connection to the wall outlet is loosened.
• Periodically remove dust from the plug.
• DO NOT insert ngers or foreign objects into the air intake or air outlet.
• Always hold the plug and never pull on the cord when removing the power plug.
Electrical shock and/or re from a short circuit may result.
• DO NOT remove the plug when your hands are wet.
• DO NOT use the unit near gas appliances or replaces.
• If the power cord is damaged, it must be replaced by the manufacturer, a Sharp Approved Ser-
vice Centre or a qualied person in order to avoid a hazard.
• Be cautious when cleaning the unit. Strong corrosive cleansers may damage the exterior.
• DO NOT use it in the areas where the unit may get wet.
• DO NOT use spray products near the unit.
DO NOT use in the areas where the unit might be exposed to oil component, incense, cigarettes’ sparks, and chemical fumes.
• DO NOT operate when using aerosol insecticides or in rooms where there is oily residue, in­cense, sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may get wet, such as a bathroom.
• Only a Sharp Approved Service Centre should service this Plasmacluster Ion Generator.
Contact the nearest Service Centre for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
CAUTIONS CONCERNING OPERATION:
• DO NOT block the air intake and/or air outlet.
• DO NOT use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam.
• Always operate the main unit in an upright position.
• Clean the exterior with a soft cloth only, otherwise the main unit surface may be damaged or cracked.
• Keep the main unit away from water.
INSTALLATION GUIDELINES:
• Place at least 2m away from equipment utilizing electric waves such as televisions or radios to avoid electrical interference when using the unit.
• Avoid using in locations where the unit is exposed to condensation or drastic temperature changes. Appropriate room temperature is between 0-35ºC.
• Avoid locations where grease or oily smoke is generated, otherwise the main unit surface may crack as a result.
NOTE - Radio or TV Interference:
If this Plasmacluster Ion Generator causes interference to radio or television reception, try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the distance between the unit and radio/TV receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
E-2
PARTS NAME
FRONT
DISPLAY
Unit Replacing
(See E-6)
Light
High
(red)
(blue)
Louvres
(See E-4)
Top Cover Cap
Screws
Air outlet
(blue)
Low
Button
Fan Speed Indicators
Filter (Air Intake)
BACK
Operation
Top Cover
Plasmacluster Ion Generating Unit
(See E-6,7)
Filter (Air Intake)
(See E-5)
Use a pointed object, e.g a pen tip, to press this button after replacing Plasmacluster Ion Generating Unit. Do not press it for any other purpose.
(This is to reset the Unit Replacing Light.)
ENGLISH
Power Cord
Plug
E-3
INSTALLATION POSITION
Place the main unit on a smooth,
DO NOT USE the below items near the unit.
sta b le sur f ace in a r oom an d insert the plug into an outlet.
DO NOT carry the unit by holding the louvres.
silicone-containing products*
SPRAY
WAX
PESTICIDES
Installation Guidance.
Leave at least 15cm of clearance behind the Unit. 20cm on both sides, and 1m abore the unit.
ABOVE More than 1m
BEHIND More than 15cm
LEFT/RIGHT SIDE More than 20cm
* Hair care products, cosmetic products,
water proof sprays, polish glass cleaner, and spray on wax.
OPERATION
Press the operation button to directly turn on the power and select the preferred mode.
LOW
Release high-density Plasmacluster ions quietly.
Increase the volume of
HIGH
'OFF'
Plasmacluster ions to increase the purifying capacity.
Power 'OFF'.
Louvres
The air comes from the direction, which is marked with the sigh on the louvres.
•When releasing ions to the entire room, put each louvres in opposite directions.
•When releasing ions to the point to deodorise the adhering odour on clothes, put both louvres in the same direction
E-4
.
CLEANING AND MAINTENANCE
WARNING:
When cleaning the unit, be sure to rst unplug the power cord,
and never handle the plug with wet hands.
Electrical shock and/or bodily injury may occur as a result.
Main Unit
Every month or more often if necessary
Wipe with a dry soft cloth.
<For Stubborn Dirt>
Use water and a mild detergent. Then wipe with a well wrung-out cloth. Make sure to dry out the main unit before use.
rt>
Filter
Every 2 weeks or more often if necessary
Gently remove dust from the fi l t e r s by u s i n g a va c u u m cleaner.
Filter
<For Stubborn Dirt>
Detach the filter and remove dust with using a vacuum cleaner.
ENGLISH
Filter
* The lter is not disposable item. Clean it often.
E-5
PLASMACLUSTER ION GENERATING UNIT REPLACEMEN
T
In order to release Plasmacluster Ions stably, it is necessary to periodically replace the Ion Generating Unit. The Unit Replacing Light will be ON as a reminder for replacement.
Elapsed Time
Beginning to use
approx. 17,500 hours (approx. 2 years if used 24/7)
approx.19,000 hours (approx. 2 years and 2 months if used 24/7)
Plasmacluster Ions are not released.
lighting (blue)
lighting (blue)
Display
ashing(red)
ashing faster
(red)
All lights are
ashing
Message
Suggest replacing
• Stop working
• Replace the Plasmacluster Ion Generating Unit.
Error*
*Usage environment affects the lifetime of the Plasmacluster Ion Generator.
The Plasmacluster Ion Generator may stop working before estimated lifetime. In this case, press Operation button again and restart. If this does not help, replace with a new Plasmacluster Ion Generating Unit.
Plasmacluster Ion Generating Unit for replacement
Plasmacluster Ion Generating Unit
Model Number
IZ-CA10E
<For Disposal>
Please dispose of the used Plasmacluster Ion Generating Unit according to any local laws and regulations.
-materials-
• Case : Polystyrene
Unit : Polystyrene Terephthalate, Electric parts
E-6
HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT
*When replacing the Plasmacluster Ion Generating Unit, be sure to turn off the main unit, unplug the power cord, and never handle the plug with wet hands.
Remove the
1
LOUVRES.
Remove the TOP
2
COVER CAP.
Turn the 2 SCREWS
3
Lift up the TOP
4
COVER.
Replace the
5
Plasmacluster Ion Generating Unit.
ENGLISH
SCREWS
*See the manual of Plasmacluster Ion Generating Unit for replacement.
E-7
SPECIFICATIONS
Model
Power supply
Power consumption (W)
Operating noise level (dBA)
Airow volume(m3/hour)
Applicable oor surface area (m2)*
Power cord (m)
Outer dimensions (mm)
Weight (kg)
*The target oor surface area for which an emitted airborne ion density of about 25,000 ions/cm be measured at a point near the center of the room (at a height of about 1.2 m from the oor), during
operation at the HIGH mode when the main unit is placed near a wall.
• The number of ions will vary according to the room conditions and the the main unit operation mode.
(High)
(High) 44
(High) 102
140 160 345 (W D H)
IG-A10J
220-240V 50Hz
14.0
(Low) 6.5
(Low) 34
(Low) 72
10
1.8
2.5
3
can
TROUBLESHOOTING
Before calling for service, please review the TROUBLESHOOTING chart below,since the problem may not be a Plasmacluster Ion Generator malfunctions.
Problem
The Plasmacluster Ion Generator does not work.
ashing faster
(red)
ashing (red)
ashing (blue)
ashing (blue)
Make sure to put in the plug.
Approx. 2 years and 2 months (approx. 19,000 hours) has been passed. Replace with a new Plasmacluster Ion Generating Unit. See page E-6,7.
Plasmacluster Ions are not released. Press the Operation button and restart.
If all lights keep ashing, replace with new
Plasmacluster Ion Generating Unit. See page E-6,7.
Dust may block the lter, clean the lter.
Failure Unplug and contact the store you purchased the unit from, or a Sharp Approved Service Centre.
WHAT TO DO
ashing (blue)
The discharged air has odour. The Plasmacluster Ion Generator releases a
A clicking or ticking sound comes from t he unit while operating th e Plasmacluster Ion Generator.
small trace of ozone which may produce odour. The level of ozone emitted by the unit is within the safety standards and does not create health risks.
Loudness can be c hanged dep ending on room humidity, but the effectiveness is the same. Relocate the Plasmacluster Ion Generator if necessary.
E-8
If you still require service, contact your SHARP Approved Service Centre. SHARP Approved Service Centre locations can be found in the support area of our website:
Australia : http://www.sharp.net.au New Zealand : http://www.sharp.net.nz
ENGLISH
E-9
1CN
SHARP CORPORATION OF AUSTRALIA PTY.LTD.
A. B. N. 40 003 039 405
1 HUNTINGWOOD DRIVE, HUNTINGWOOD, N.S.W. 2148
P.O.BOX 6827, BLACKTOWN. N.S.W. 2148
www.sharp.net.au
SHARP CORPORATION OF NEW ZEALAND LIMITED
59 HUGO JOHNSTON DRIVE, PENROSE, AUCKLAND
www.sharp.net.nz
Printed in China
TINS-A359KKRZ 09K-
Loading...